Search NASA⌕ Search

SEARCH · Search NASA

Results for “power systems control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Time-frequency based cyber security defense of wide-area control system for fast frequency reserve

Global power systems are transiting from conventional fossil fuel energy to renewable energies due to their environmental benefits. The increasing penetration of renewable energies presents challenges for power system operation. The efficiency and sufficiency of responsive reserves have become increasingly important for power systems with a high proportion of renewable energies. The Fast Frequency Reserve (FFR), especially the Wide-area Monitoring System (WAMS)-based FFR, is a promising and effective solution to secure and enhance the stability of power systems. However, cyber security has become a new challenge for the WAMS-based FFR system. Cyber attacks on the FFR control system may threaten the safety of power system operation due to the rapid power controllability requirement of FFR. Therefore, to address this problem, a time-frequency based cyber security defense framework is proposed to detect the cyber spoofing of synchrophasor data in WAMS-based FFR control systems. This paper first introduces the Continuous Wavelet Transforms (CWTs) to decompose spoofing signals. Then, the Dual-frequency Scale Convolutional Neural Networks (DSCNN) is proposed to identify the time-frequency domains matrix from two frequency scales. Integrating CWTs and DSCNN, an identification framework called CWTs-DSCNN is further proposed to detect the spoofing attacks in the WAMS-based FFR system. Multiple experiments using the actual data from FNET/GridEye are performed to verify the effectiveness of the framework in securing WAMS-based FFR systems.

25 ENERGY STORAGE↗

Controlling a power output of a nuclear reaction without control rods

A nuclear power system includes a reactor vessel that includes a reactor core that includes nuclear fuel assemblies configured to generate a nuclear fission reaction. A representative nuclear power system further includes a riser positioned above the reactor core and a primary coolant flow path that extends from a bottom portion of the reactor vessel, through the reactor core, and through an annulus between the riser and the reactor vessel. A primary coolant circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the heat to a power generation system configured to generate electric power. The nuclear power system further includes a control rod assembly system positioned in the reactor vessel and configured to position control rods in only two discrete positions.

Callaway, Allyson↗

Controlling a power output of a nuclear reactor without using control rods

A nuclear power system includes a reactor vessel that includes a reactor core that includes nuclear fuel assemblies configured to generate a nuclear fission reaction. A representative nuclear power system further includes a riser positioned above there actor core and a primary coolant flow path that extends from a bottom portion of the reactor vessel, through the reactor core, and through an annulus between the riser and the reactor vessel. A primary coolant circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the heat to a power generation system configured to generate electric power. The nuclear power system further includes a control rod assembly system positioned in the reactor vessel and configured to position control rods in only two discrete positions.

Callaway, Allyson↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active Damping With Energy Storage to Improve Power System Frequency Stability

As renewable resources displace traditional generation, there may be times when there is relatively less rotational inertia (H, MW-s) to stabilize power system frequency following a power system disturbance. This article outlines a method for the control of Battery Energy Storage System (BESS) to mitigate power system frequency disturbances. The control scheme discussed in the article leverages latest ‘smart grid’ technologies including PMU’s and advanced grid-supportive inverters. The authors’ screening-level analysis of this novel BESS control concept indicates the potential to increase the speed of recovery of disturbed power systems, i.e. return power system frequency to nominal value (60 Hz in N. America), following a system disturbance. Increasing power system stability by adding inertial-support from appropriately controlled BESS will help power systems accommodate more renewable generation before hitting stability limits.

Energy Storage↗

Distributed Optimization Approaches with Discrete Variables in the Power Distribution Systems

Traditionally, centralized approaches have predominantly been used for the power system operation and control. With increasing penetration of small-scale distributed energy resources (DERs) in the distribution network, especially independently owned renewable resources, distributed algorithms can serve as a potential alternative for improving scalability, resiliency and addressing privacy concerns. However, the complexity of distributed algorithms significantly increases with the integration of the legacy devices, the operation of which depend on discrete control variables. This paper aims to provide a review of the distributed optimization algorithms incorporating discrete control variables for the power distribution system. While the research in this domain is still at its nascence, an extensive comparison of the approaches in the literature for applying quadratic penalty, branch and bound,ordinal optimization and proximal operator to handle discrete variables in the framework of ADMM and dual decomposition have been addressed. Future research direction in this field have been also provided.

Adan, Jannatul↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗

Dynamic Distribution System Restoration Strategy for Resilience Enhancement: Preprint

In electric power distribution systems, distributed energy re-sources (DERs) can act as controllable power sources and support utility operators to minimize power outages after ex-treme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influ-ences of extreme events and the capabilities of DERs are dy-namic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availabil-ity of DERs. In this paper, we propose a new dynamic distribu-tion system restoration strategy to enhance system resilience against potential hazards. An efficient reconfiguration algo-rithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER opera-tion setpoints based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-Based Randomized Encoding for Sensor Authentication in Power Grid SCADA Systems

Supervisory Control and Data Acquisition (SCADA) systems are utilized extensively in critical power grid infrastructures. Modern SCADA systems have been proven to be susceptible to cyber-security attacks and require improved security primitives in order to prevent unwanted influence from an adversarial party. One section of weakness in the SCADA system is the integrity of field level sensors providing essential data for control decisions at a master station. In this paper we propose a lightweight hardware scheme providing inferred authentication for SCADA sensors by combining an analog to digital converter and a permutation generator as a single integrated circuit. Through this method we encode critical sensor data at the time of sensing, so that unencoded data is never stored in memory, increasing the difficulty of software attacks. We show through experimentation how our design stops both software and hardware false data injection attacks occurring at the field level of SCADA systems.

42 ENGINEERING↗

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to the Special Section on Control and Management of Electric Power Systems With High Shares of Inverter-Based Resources

The growing interest in the integration of variable renewable energy (VRE) and distributed energy resources (DER) on both policy and economic grounds is driving the transformation of electric power systems. The significant deployment of VRE and DER can effectively displace the conventional synchronous generator-based power plants that for decades have been the foundation for power system generation and stability in electric power systems. Inverter-based resources (IBRs) introduce a high-level of uncertainty, variability, and complexity into the operation of electric power networks, and the transformation to IBRs raises a wide range of technical questions and operational challenges. The optimal coordination and control of these resources requires greater interoperability and necessitates significant upgrades of grid automation, including real-time monitoring.

distributed power generation↗

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency↗

Turbine-based Power System Tool

Advanced research tools are essential to illustrate the effects of turbine-based power system operations on the electric grid network. This paper presents the development of an open-source tool to visualize the operation of turbine-based electricity generation. The tool exposes power system models, control parameters, and corresponding values of the turbine model and its electrical system, allowing them to customize the simulation according to their needs. The developed tool enables users to simulate power profiles for different turbinebased energy generation such as wind, tidal, and gas turbines. It allows users to investigate the details of the generated profiles of various types of turbine systems at various scales. It can provide valuable insights into model development and facilitate the analysis of integrated power systems. By enabling access to turbine-based operations visualization, the tool aims to bridge the gap between advanced research tools and users, facilitating broader adoption of renewable energy technologies and aiding in developing sustainable power systems.

Kini, Roshan L.↗

Report for 2.2.1 Task 5: Develop and Document a State-Based Alarm System for a Nuclear Power Plant Control Room Using Machine Learning

Idaho National Laboratory (INL) has contracted IFE to support human factors research and the development of leading-edge technology to support control room operators as the U.S. fleet undergoes modernization and digitalization in legacy plants and control rooms. As the nuclear industry starts to shift to more digital controls and systems, these upgrades provide more information to the main control room in the form of digital signals and values. Also, an increase in the number of alarms points is provided by the vendors. New digital control rooms shift from main control boards to soft controls, and alarm panels to a single display. This change to a single display has created a problem of alarm waterfall, a situation in which the addition of new alarm points causes an overload of information to the operator during either a plant disturbance or other than normal full power operations. IFE’s goal is to find a workable solution to assist operators in both handling and understanding incoming alarms during emergency situations under these waterfall conditions.

99 GENERAL AND MISCELLANEOUS↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗