Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Porosity evolution in proton irradiated microfine-grained POCO graphite

This work investigated the porosity evolution of POCO ZXF-5Q graphite that has been irradiated by 340 kW, 120 GeV protons inside NT02 target system in Fermilab's NuMI beamline. This POCO graphite has undergone direct bulk dimensional swelling at low dose irradiation and its local microstructural change is still not well-understood during this process. In this work, the (sub-) micrometre scale porosity from six locations across proton beam fluence and temperature gradients have been studied using focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Here, a deep learning-based tomographic image segmentation technique has been established and implemented for porosity segmentation and quantification. It has been found that there is a decrease in the total volumetric percentage of the porosity at proton beam centre (~ 8 – 8.4 vol.%), by comparing to un-irradiated POCO (~ 12 – 13vol.%) and to beam 2σ and 5σ radii (~ 12vol.%). This decrease in porosity volume percentage was found to be caused by the reduction in pores with volumes > 0.1 μm 3 induced by material bulk dimensional swelling at proton beam centre area. The porosity reduction in relation to dimensional change and irradiation creep was discussed among with other contributing factors, and further investigations through well-controlled irradiation experiment are still needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R&D toward design for a pion-production target for Mu2e-II

The Mu2e experiment at Fermilab will search for evidence of charged lepton flavor violation by observing the conversion of a negative muon into an electron in the Coulomb field of a nucleus without emission of neutrinos and will probe effective new-physics mass scales in the 103-104 TeV range. One of the main parts of the Mu2e experimental setup is its target station in which negative pions are generated in interactions of the 8 GeV primary proton beam with a tungsten target, which will be capable of producing $2\times10^{17}$ negative muons per year. Mu2e can be extended by a next generation experiment, Mu2e-II, with a sensitivity improved by another factor of 10 or more as enabled by the PIP-II accelerator upgrade project. PIP-II is a 250-meter-long linac capable of accelerating a 2 mA proton beam to a kinetic energy of 800 MeV corresponding to 1.6 MW of power. To achieve another factor of ten improvement in sensitivity, Mu2e-II will require about 100 kW of proton beam on target, and the added power requires a new target design. We will present our progress in RD of a target station conceptual design for Mu2e-II, using the MARS15 and G4beamline Monte-Carlo codes toward a selection between granular, conveyor, and rotating cylindrical target options.

Lynch, Kevin Richard↗

Nonlinear integrable optics beam dynamics experiment and diagnostics

All present circular particle accelerators are built around linear focusing optics. Un-avoidable nonlinear elements appear in accelerators, such as magnetic aberrations and space-charge effects, which are typically corrected using nonlinear magnets. However, these added nonlinearities degrade particle beam stability, and in most cases, the system becomes non-integrable. The Integrable Optics Test Accelerator (IOTA), at Fermi National Accelerator Laboratory (Fermilab), is a test bed to study beam dynamics in integrable lattices for both electron and proton beams, independently. This work presents experimental results of the nonlinear electron beam dynamics behavior in IOTA using an elliptical nonlinear magnet. The elliptical nonlinear magnet allows for a large betatron tune spread, allowing for a stable high-intensity beam. In a future experimental run, minimally invasive beam instrumentation is needed to study time-dependent collective instabilities, and halo formation in space-chargedominated proton beams. Traditional profile monitors are too destructive to the beam or just measure one dimension of the beam. A gas sheet can be injected perpendicular to theproton beam at an angle. By doing so, a two-dimensional, turn-by-turn, transverse profile measurement can be made, which will preserve the integrity of the beam. The developmentand progress of a gas sheet beam profile monitor will also be presented.

43 PARTICLE ACCELERATORS↗

Beams of protons and alpha particles greater than approximately 30 keV/charge from the earth's bow shock

Two beamlike particle events (30 keV/charge to 160 keV/charge) upstream of the earth's bow shock have been investigated with the Max-Planck-Institut/University of Maryland ultralow energy and charge analyzer on ISEE 1. These beams consist of protons as well as of alpha particles, and the spectra are generally steep and are decreasing with increasing energy. During one event the spectra of both protons and alpha particles have a maximum at approximately 65 keV/charge. During these events, the interplanetary magnetic field through the satellite position was almost tangent to the bow shock, and application of the theory of acceleration predicts acceleration of a solar wind particle up to 60 keV/nucleon in a single reflection. The observation of reflected protons as well as alpha particles has implications for the physical reflection process usually not discussed in acceleration theories.

Scholer, M.↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

A simple model of space radiation damage in GaAs solar cells

A simple model is derived for the radiation damage of shallow junction gallium arsenide (GaAs) solar cells. Reasonable agreement is found between the model and specific experimental studies of radiation effects with electron and proton beams. In particular, the extreme sensitivity of the cell to protons stopping near the cell junction is predicted by the model. The equivalent fluence concept is of questionable validity for monoenergetic proton beams. Angular factors are quite important in establishing the cell sensitivity to incident particle types and energies. A fluence of isotropic incidence 1 MeV electrons (assuming infinite backing) is equivalent to four times the fluence of normal incidence 1 MeV electrons. Spectral factors common to the space radiations are considered, and cover glass thickness required to minimize the initial damage for a typical cell configuration is calculated. Rough equivalence between the geosynchronous environment and an equivalent 1 MeV electron fluence (normal incidence) is established.

Wilson, J. W.↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Feasibility of using crystal channeling for the beam loss mitigation in Slow Extraction at 8GeV

The mitigation of the beam losses in slow extraction is becoming more and more demanding in accelerator applications for HEP as the beam power is gradually increasing. The successful demonstration of using the proton beam channeling at 450GeV to deflect the beam away from the extraction septa opens the new levels of improving the slow extraction efficiency. It is yet to be demonstrated that this method is still effective at low and medium proton beam energies. Here we present the promising results of the recent computer simulation studies of the septum shadowing at 8GeV for the Mu2e project slow extraction at Fermilab. Depending on the beam parameters the beam loss reduction is shown to be achievable in the range of 1/3 to factor of 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

In order to prevent emittance growth during long stores of the proton beam at the future Electron-Ion Collider (EIC), we need to have some mechanism to provide fast cooling of the dense proton beams. One promising method is coherent electron cooling (CeC), which uses an electron beam to both ?measure? the positions of protons within the bunch and then apply energy kicks which tend to reduce their longitudinal and transverse actions. In this work, we discuss the under- lying physics of this process. We then discuss simulations which constrain the electrons to move only longitudinally in order to perform fast optimizations and long-term track- ing of the bunch evolution, and benchmark these results against fully 3D codes. Additionally, we discuss practical challenges, including the necessity of a high-quality elec- tron beam and sub-micron alignment of the electrons and protons.

Deitrick, K.↗

A novel, steerable, low-energy proton source for detector characterization

We report on the conversion of the Manitoba II mass spectrometer into a versatile low-energy proton beam facility. This infrastructure is adaptable to any detector-under-test (DUT), and has proven itself effective with the characterization of silicon detectors used in subatomic beyond-the-Standard-Model (BSM) searches, namely the Nab experiment. A pencil beam of mono-energetic protons can be produced in a range from 25 keV to 35 keV, achieving a beam current of ~1 x 10 -18 A. Electrostatic steering plates were constructed to direct the Gaussian-profile proton beam over a 117 mm diameter area-of-interest with full-width at half-maxima (FWHM) ranging from 0.6 mm to 1.26 mm. This work discusses the modifications and subsequent tests to confirm the beam specifications met the demands of the aforementioned detectors.

Fundamental neutron physics↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Beam-Based Target Alignment for Mu2e

The Mu2e Experiment is a precision experiment at Fermi National Accelerator Laboratory, searching for charged lepton flavor violation (CLFV) in the conversion of a muon to an electron in the presence of an atomic nucleus. In order to achieve the expected single-event sensitivity of $3\times 10^{-17}$ , Mu2e will require an intense muon beam, generated via pion decay. These pions are the product of a proton beam striking a radiatively-cooled tungsten target. In order to maximize pion production and prevent target failure, the beam will have to be aligned with the target center to within 0.5 mm. The production target monitor (PTM) will ensure this alignment. The PTM consists of a series of proportional wire chambers (PWC’s) upstream and downstream of the production target. In this dissertation, I explain the requirements of this detector system and derive the decisions about which detector model to use and how they should be arranged from these requirements. After this, I describe my e xperience building the detectors and show an early use for them in the Mu2e proton beam. I also performed a study of the sensitivity and time resolution of this model of PWC and its electronics, and give the results here. I then describe a series of simulation campaigns which shed light on the interactions between the beam and the target, and how these interactions manifest on the downstream detectors. Finally, I give the target scanning procedure to be used to align the beam and target during experiment start up.

43 PARTICLE ACCELERATORS↗

Non-Neutron Transmutation of Used Nuclear Fuel (Final Report)

The primary goal of this study is to develop a national facility concept for transmuting long-lived fission products (LLFP) to substantially reduce the disposal impact by minimizing the need for a geologic-timescale repository. As a charter for this study, the national transmutation facility was required to reduce the radiotoxicity and decay heat of LLFP isotopes by at least 90% relative to their values at discharge from a commercial LWR, while consuming less than 10% of the reactor's energy. The identified LLFP isotopes are Se-79, Zr-93, Tc-99, I-129, Sn-126, and Cs-135, whose radiotoxicity is about 99% of the total radiotoxicity of all fission products at 1,000 years. Approximately ~72 kg of LLFPs is discharged every year from a 1,000 MWe commercial or advanced nuclear reactor. First, LLFP transmutation options with non-neutron beams (photons and protons) were explored. The study concluded that LLFP transmutation is feasible with high-energy, high-intensity photons or protons, but impractical on an engineering scale due to low transmutation rates and the high energy requirements to produce the desired photon or proton beams. As alternatives, LLFP transmutation options with neutrons from fission, fusion, and spallation reactions were additionally explored. The transmutation options using advanced critical reactors are attractive only for selective LLFP isotopes because the production rates of several LLFP isotopes (Zr-93, Sn-126, and Cs-135) from fission reactions are larger than the transmutation rates. The transmutation options with only spallation neutrons are favorable to transmute all LLFP isotopes, but as a tradeoff, the net transmutation rates are reduced. The national transmutation facility concept was developed following an exploration of transmutation options using various incident particles. The proposed national LLFP transmutation comprises a dedicated molten-salt reactor (MSR), a proton accelerator, and a spallation neutron-based transmuter. The MSR power was set at 300 MWt and 120 MWe, with the thermal power approximately 10% of that of a commercial 1,000 MWe PWR. The electricity generated by the MSR powers the accelerator and transmuter. The accelerator produces 1 GeV, 30 mA protons, which are introduced into the spallation neutron-based transmuter. The spallation neutron-based transmuter consists of a central spallation target and LLFP target pins merged in a heavy water tank. The six LLFP isotopes are separated into two groups. Tc-99, I-129, and Se-79, having larger neutron cross sections, belong to group A, while Zr-93, Sn126, and Cs-135, having smaller neutron cross sections, belong to group B. Then, for effective transmutation, LLFPs in groups A and B are transmuted in the dedicated MSR and in a spallation neutron-based transmuter, respectively. The estimated capital cost of the national transmutation facility is approximately $\$$3.1B, and its annual O&M cost is expected to be ~$\$$182M. Radiotoxicity and decay heat of LLFPs were calculated and compared with those of the original LLFPs. It was assumed that the targets were made with elementwise LLFP rather than isotopic LLFP, owing to the potentially high cost of isotopic separation from used nuclear fuels. The decay heat of LLFPs can be reduced by more than 90% using a single national transmutation facility. However, radiotoxicity decreases by 79–84%, which does not meet the transmutation performance requirement, primarily because Cs-135 is produced rather than depleted. Thus, to meet the design requirement, Cs-135 should be separated from other Cs isotopes and irradiated in a spallation neutron-based transmuter. Then, radiotoxicity decreases by ~92%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50 μm, 100 μm, and 150 μm were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR), and energy linearity is an important property for particle ID capabilities.

Particle tracking detectors↗

Warm Unit Stand Assembly and Testing for Proton Improvement Plan - II

The Proton Improvement Project II (PIP II), situated at Fermilab, signifies a critical advancement in the realm of high-energy physics. PIP II, a linear accelerator renovation endeavor, aspires to double the output of the existing proton beam, reinforcing Fermilab’ s position as a vanguard in this field. The proton beam's creation involves a series of high-frequency cryomodules, necessitating environmental temperature arrays of magnets and vacuum pumps henceforth described as ‘Warm Units.’ The Warm Units include design features of : 1. insertion between the cryomodules, 2. multi-stage adjustments in six degrees of freedom to ensure precise beam alignment; 3. Natural frequency modes that avoid specified ranges. In adherence to Fermilab’ s stringent safety standards, comprehensive testing procedures are slated to validate the Warm Units' capacity to simultaneously achieve local alignment adjustments while averting low-frequency oscillation less than 15 Hertz. The testing regimen will scrutinize the Warm Units' alignment adjustment capabilities and their resilience against low-frequency oscillations, with an overarching objective of satisfying the Final Design Review criteria specific to the PIP II initiative. This project works to furnish technicians responsible for the assembly of Warm Units with a comprehensive guide for successful installation, concurrently documenting any requisite design modifications essential for achieving a real-world configuration.

43 PARTICLE ACCELERATORS↗

Automating Anomaly Detection for Target systems at Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, produces the world’s most intense pulse neutrons beams. An accelerated proton beam is directed into a mercury target to generate neutrons via spallation. The target system accounted for over 40% of the overall downtime of the facility in 2022. Thus, early detection in anomalies in the target systems can enable taking corrective actions to avoid failures and reduce downtime. Fault prognostics and anomaly detection in accelerators, both at SNS and outside, has largely focused on the beam side. This paper presents one the first studies exploring leveraging machine learning to automate the detection of anomalies in the target system. The target system consists of over 30 different interconnected subsystems, and the present work focuses on the mercury process system as a use case. Analyzing data from 28 process variables from 2022 and 2023, tree-based and reconstruction-based algorithms are employed to detect anomalies in archived data. The algorithms detected previously unreported anomalies, several of which were deemed alert worthy by human experts, particularly those found by reconstruction-based algorithms. Using data from each production run in the accelerator increased the generalizability of the models in time. Efforts are now underway to implement a workflow for incorporating human feedback to update the models and evaluating performance on unseen data. The models will eventually be integrated into the existing System Tracking and Reliability system with a web interface for automated anomaly detection and reporting along with a pathway for incorporating human feedback for model updates.

Raj, Anant [ORNL] (ORCID:0000000306711244)↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗