Search NASA⌕ Search

SEARCH · Search NASA

Results for “total volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Blood volume reduction counteracts fluid shifts in water immersion

Six healthy men were bled by 15 percent of their total blood volume (TBV) before 7 h of seated water immersion, to test the hypothesis that some of the major physiological responses to an expansion of central blood volume can be counteracted by prior reduction of TBV. Subjects were their own controls under two conditions: seated dry in air and seated immersed to the suprasternal notch in water. Immersion without prior reduction of TBV Wet Control (WC) caused a statistically significant 22-percent increase in cardiac output (CO), 368-percent increase in urine production, and 200-percent increase in sodium excretion relative to dry control (DC) sessions. When TBV was reduced before immersion, CO was the same as during DC sessions; however there were significant increases above DC in urine flow (+73 percent) and sodium excretion (+120 percent), although they were significantly reduced from WC values. Potassium excretion was similar during DC and WC sessions, but was significantly increased (+75 percent) when subjects were immersed after 15-percent reduction of TBV.

Simanonok, Karl E.↗

Alpha-Quartz Plastic Strength Investigation Via Diffraction Experiments on Novaculite Using A D-Dia and Elastic Plastic Self- Consistent Interpretation [Thesis}

X-Ray Tomography. Porosity is commonly measured using mercury injection (MI) or water immersion porosimeter (WIP). Both MI and WIP utilize pressure to fill open voids with mercury or water respectively. A measure of the volume change of the sample is then used to estimate the percentage of open voids. However, for the purpose of rheological study it is important to get an accurate measure of open and closed voids. X-ray tomography has been selected as it offers a three-dimensional view into the sample that can quantify all pores limited only by the voxel size which is in the micron range for this study. Radiographs for tomography were collected at the Material Science and Technology Division at Los Alamos National Lab using the Carl Zeiss Xradio 520 instrument and Scout-and-Scan version 16.1 operating software. Two samples were imaged, the starting material and the deformed sample SiO2_65. 3001 radiographs were taken of the starting material with a 6 second exposure time using a 4x objective lens. The x-ray beam was set to 60 kilovoltage peak (kVp) and 5 watts. 1901 radiographs were taken of SiO2_65 with a 25 second exposure time using a 10x objective lens. The x-ray beam was set to 80 kVp and 7 watts. Radiograph files were analyzed by Brian Patterson using Avizo. Void and inclusion volumes were output by voxel sized (1.03 μm) slices, used to calculate a total percentage volume for the starting material.

36 MATERIALS SCIENCE↗

Interaction of central venous pressure, intramuscular pressure, and carotid baroreflex function

Seven healthy volunteer men participated in an experiment involving lower body positive pressure (LBPP) of 30 Torr and acute volume expansions of 5-6% (VE-I) and 9-10% (VE-II) of their total blood volume (TBV) to differentiate the effect of increased intramuscular pressure and central venous pressure (CVP) on the maximal gain (Gmax) of the carotid baroreflex. During each experimental condition, the heart rate (HR), mean arterial pressure (MAP; intraradial artery or Finapres), and CVP (at the 3rd-4th intercostal space) were monitored continuously. Gmax was derived from the logistic modeling of the HR and MAP responses to ramped changes in carotid sinus transmural pressure using a protocol of pulsatile changes in neck chamber pressure from +40 to -65 Torr. The increase in CVP during +30-Torr LBPP was 1.5 mmHg (P < 0.05) and was similar to that observed during VE-I (1.7 mmHg, P > 0.05). The Gmax of the carotid baroreflex of HR and MAP was significantly decreased during LBPP by -0.145 +/- 0.039 beats x min(-1) x mmHg(-1) (38%) and -0.071 +/- 0.013 mmHg/mmHg (25%), respectively; however, VE-I did not affect Gmax. During VE-II, CVP was significantly greater than that elicited by LBPP, and the Gmax of the carotid baroreflex of the HR and MAP responses was significantly reduced. We conclude that carotid baroreflex responsiveness was selectively inhibited by increasing intramuscular pressure, possibly resulting in an activation of the intramuscular mechanoreceptors during LBPP. Furthermore, it would appear that the inhibition of the carotid baroreflex, via cardiopulmonary baroreceptor loading (increased CVP), occurred when a threshold pressure (CVP) was achieved.

NASA Discipline Cardiopulmonary↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Determining blood and plasma volumes using bioelectrical response spectroscopy

We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.

NASA Discipline Number 00-00↗

Total-dose radiation effects data for semiconductor devices, volume 1

Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. Data are presented by JPL for various NASA space programs on diodes, bipolar transistors, field effect transistors, silicon-controlled rectifiers, and optical devices. A vendor identification code list is included along with semiconductor device electrical parameter symbols and abbreviations.

Price, W. E.↗

Comparison of water immersion and saline infusion as a means of inducing volume expansion in man

The study compares the natriuresis induced by head-out water immersion to that of a standard saline infusion and assesses the relative effectiveness of these two techniques as volume determinants of renal sodium and water handling in humans in a seated posture. The data obtained show that the volume stimulus of immersion is identical to that of standard saline-induced extracellular fluid volume expansion (ECVE) in normal seated subjects. The ability of head-out water immersion to induce a natriuresis without a concomitant increase in total blood volume and with a decrease in body weight suggests that water immersion may be preferred as an investigative tool for assessing the effects of ECVE in man.

Epstein, M.↗

Changes in total plasma content of electrolytes and proteins with maximal exercise.

To determine to what extent the increases in concentration of plasma proteins and electrolytes with short maximal work were a result of hemoconcentration, the changes in plasma volume and total content of the plasma constituents were simultaneously evaluated. The results obtained from six human subjects indicated that in comparison to preexercise values there was a net decrease in total content of plasma protein, sodium, and chloride in the first 2 min of the postexercise period, due primarily to a significant loss (13-15%) of plasma fluid. The total plasma potassium content was increased immediately after exercise but was significantly below the preexercise plasma content after 2 min of recovery.

Van Beaumont, W.↗

Tracer techniques for urine volume determination and urine collection and sampling back-up system

The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

Ramirez, R. V.↗

Estimating forest biomass and volume using airborne laser data

An airborne pulsed laser system was used to obtain canopy height data over a southern pine forest in Georgia in order to predict ground-measured forest biomass and timber volume. Although biomass and volume estimates obtained from the laser data were variable when compared with the corresponding ground measurements site by site, the present models are found to predict mean total tree volume within 2.6 percent of the ground value, and mean biomass within 2.0 percent. The results indicate that species stratification did not consistently improve regression relationships for four southern pine species.

Nelson, Ross↗

Human muscle sympathetic neural and haemodynamic responses to tilt following spaceflight

Orthostatic intolerance is common when astronauts return to Earth: after brief spaceflight, up to two-thirds are unable to remain standing for 10 min. Previous research suggests that susceptible individuals are unable to increase their systemic vascular resistance and plasma noradrenaline concentrations above pre-flight upright levels. In this study, we tested the hypothesis that adaptation to the microgravity of space impairs sympathetic neural responses to upright posture on Earth. We studied six astronauts approximately 72 and 23 days before and on landing day after the 16 day Neurolab space shuttle mission. We measured heart rate, arterial pressure and cardiac output, and calculated stroke volume and total peripheral resistance, during supine rest and 10 min of 60 deg upright tilt. Muscle sympathetic nerve activity was recorded in five subjects, as a direct measure of sympathetic nervous system responses. As in previous studies, mean (+/- S.E.M.) stroke volume was lower (46 +/- 5 vs. 76 +/- 3 ml, P = 0.017) and heart rate was higher (93 +/- 1 vs. 74 +/- 4 beats min(-1), P = 0.002) during tilt after spaceflight than before spaceflight. Total peripheral resistance during tilt post flight was higher in some, but not all astronauts (1674 +/- 256 vs. 1372 +/- 62 dynes s cm(-5), P = 0.32). No crew member exhibited orthostatic hypotension or presyncopal symptoms during the 10 min of postflight tilting. Muscle sympathetic nerve activity was higher post flight in all subjects, in supine (27 +/- 4 vs. 17 +/- 2 bursts min(-1), P = 0.04) and tilted (46 +/- 4 vs. 38 +/- 3 bursts min(-1), P = 0.01) positions. A strong (r(2) = 0.91-1.00) linear correlation between left ventricular stroke volume and muscle sympathetic nerve activity suggested that sympathetic responses were appropriate for the haemodynamic challenge of upright tilt and were unaffected by spaceflight. We conclude that after 16 days of spaceflight, muscle sympathetic nerve responses to upright tilt are normal.

Non-NASA Center↗

Body water compartments during bed rest: Evaluation of analytical methods

Nine healthy young men were studied to determine the reproducibility and interchangeability of the use of radio-iodinated human serum albumin and Evans Blue dye for estimating plasma volume, sodium bromide for extracellular fluid volume, and deuterium oxide for total body water volume. All subjects were tested in a semibasal condition and allowed to rest for at least 30 min. after arriving at the laboratory. The results indicate that there was uniform distribution of I131 and Evans Blue dye 10 min. after injection and of NaBr and D2O 3 hours after oral ingestion; the buildup of residual tracer did not interfere appreciably with the measurement of either or Evans Blue spaces when they are administered at equal intervals, and the buildup of background tracer after ingestion of NaBr and D2O once per week for three consecutive weeks did not affect the accuracy of the measurement. It was found that I131 and Evans Blue may be used interchangeably for estimating plasma volume; for estimating bromide and D2O spaces, one 3-hour equilibrium blood sample gives results similar to the extrapolation of multiple samples.

Young, H. L.↗

Mars: Crustal pore volume, cryospheric depth, and the global occurrence of groundwater

It is argued that most of the Martian hydrosphere resides in a porous outer layer of crust that, based on a lunar analogy, appears to extend to a depth of about 10 km. The total pore volume of this layer is sufficient to store the equivalent of a global ocean of water some 500 to 1500 m deep. Thermal modeling suggests that about 300 to 500 m of water could be stored as ice within the crust. Any excess must exist as groundwater.

Clifford, Stephen M.↗

Chemical Method of Urine Volume Measurement

A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

QUANTITATIVE ANALYSIS↗

Lifetimes of Overshooting Convective Events using High-Frequency Gridded Radar Composites

Deep convection that penetrates the tropopause, referred to here as overshooting convection, is capable of lifting tropospheric air well into the stratosphere. In addition to water, these overshoots also transport various chemical species, affecting chemistry and radiation in the stratosphere. It is not currently known, however, how much transport is a result of this mechanism. To better understand overshooting convection, this study aims to characterize the durations of overshooting events. To achieve this, radar data from the Next Generation Weather Radar (NEXRAD) network is composited onto a three-dimensional grid at 5-min intervals. Overshoots are identified by comparing echo-top heights with tropopause estimates derived from ERA5 reanalysis data. These overshoots are linked in space from one analysis time to the next to form tracks. This process is performed for 12 four-day sample windows in the months May–August of 2017–19. Track characteristics such as duration, overshoot area, tropopause-relative altitude, and column-maximum reflectivity are investigated. Positive correlations are found between track duration and other track characteristics. Integrated track volume is found as a product of the overshoot area, depth, and duration, and provides a measure of the potential stratospheric impact of each track. Short-lived tracks are observed to contribute the most total integrated volume when considering track duration, while tracks that overshoot by 2–3 km show the largest contribution when considering overshoot depth. A diurnal cycle is observed, with peak track initiation around 1600–1700 local time. Track-mean duration peaks a few hours earlier, while track-mean area and tropopause-relative height peak a few hours later.

Atmosphere↗

Blue Carbon Stock Estimation of US Coastal Marshes from New York to Georgia How Much Do We Have to Lose?

Valued for their myriad multifunctional roles in preserving habitat for biodiversity, cycling nutrients, protecting shorelines, improving water quality, and sequestering blue carbon, coastal and riverine marshes continue to disappear not only due to land use change but also sea level rise. Blue carbon’s role in the carbon cycle has been underappreciated until the last few decades, and the carbon stocks for U.S. Atlantic coastal margins have previously been estimated for a depth of 0.5-1 meter. We select several North American East Coast databases that have been utilized to study sea level rise and instead use them to estimate marsh depth from New York to Georgia; in local marshes that lack depth data, we present new depth data and perform several full-depth transects. This alongside marsh area data from the National Wetlands Inventory (NWI) enables us to estimate marsh volume. We then utilize an average carbon density of 27 kg/m 3 by Holmquist et al. 2018 to calculate blue carbon stocks. We present the inventories of peat depth by state, marsh area by state, and total marsh volume by state, followed by the blue carbon stocks. The peat depth inventory of eastern U.S. marshes reveals that riverine marshes are significantly deeper than coastal marshes. While both are important, we highlight the jeopardy of rapidly eroding urban marshes due to the heavy metals these marshes have sequestered for centuries as they contaminate the surrounding estuary. Uncertainties and caveats include carbon density values, loss of marsh since the NWI assessment, and depth averages. The high cost of marsh disappearance underscores the urgent need for their preservation.

Coastal marshes↗

Cytoplasm-to-myonucleus ratios following microgravity

The cytoplasmic volume-to-myonucleus ratio in the tibialis anterior and gastrocnemius muscles of juvenile rats after 5.4 days of microgravity was studied. Three groups of rats (n = 8 each) were used. The experimental group (space rats) was flown aboard the space shuttle Discovery (NASA, STS-48), while two ground-based groups, one hindlimb suspended (suspended rats), one non-suspended (control), served as controls. Single fibre analysis revealed a significant decrease in cross-sectional area (microns2) in the gastrocnemius for both the space and the suspended rats; in the tibialis anterior only the suspended rats showed a significant decrease. Myonuclei counts (myonuclei per mm) in both the tibialis anterior and gastrocnemius were significantly increased in the space rats but not in the suspended rats. The mean myonuclear volume (individual nuclei: microns3) in tibialis anterior fibres from the space rats, and in gastrocnemius fibres from both the space and the suspended rats, was significantly lower than that in the respective control group. Estimation of the total myonuclear volume (microns3 per.mm), however, revealed no significant differences between the three groups in either the tibialis anterior or gastrocnemius. The described changes in the cross-sectional area and myonuclei numbers resulted in significant decreases in the cytoplasmic volume-to-myonucleus ratio (microns3 x 10(3)) in both muscles and for both space and suspended rats (tibialis anterior; 15.6 +/- 0.6 (space), 17.2 +/- 1.0 (suspended), 20.8 +/- 0.9 (control): gastrocnemius; 13.4 +/- 0.4 (space) and 14.9 +/- 1.1 (suspended) versus 18.1 +/- 1.1 (control)). These results indicate that even short periods of unweighting due to microgravity or limb suspension result in changes in skeletal muscle fibres which lead to significant decreases in the cytoplasmic volume-to-myonucleus ratio.

NASA Discipline Cell Biology↗

Determination of the total grain size distribution in a vulcanian eruption column, and its implications to stratospheric aerosol perturbation

The total grain distribution of tephra from the eruption by the Fuego volcano in Guatemala on Oct. 14, 1974 was determined by grain size analysis. The region within each isopach has a grain distribution which was weighted proportionally to its percentage volume; the total distribution had a median grain size of 0.6 mm and a sorting coefficient of 2.3. The ash composed of fine particles did not fall in the volcano area as part of the recognizable tephra blanket; the eruption column reached well into the stratosphere to the height of 10-12 km above sea level, with mass flux rate estimated altitudes of 18-23 km

Murrow, P. J.↗