Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

L-asparagine crystals with wide gap semiconductor features: Optical absorption measurements and density functional theory computations

Results of optical absorption measurements are presented together with calculated structural, electronic, and optical properties for the anhydrous monoclinic L-asparagine crystal. Density functional theory (DFT) within the generalized gradient approximation (GGA) including dispersion effects (TS, Grimme) was employed to perform the calculations. The optical absorption measurements revealed that the anhydrous monoclinic L-asparagine crystal is a wide band gap material with 4.95 eV main gap energy. DFT-GGA+TS simulations, on the other hand, produced structural parameters in very good agreement with X-ray data. The lattice parameter differences Δa, Δb, Δc between theory and experiment were as small as 0.020, 0.051, and 0.022 Å, respectively. The calculated band gap energy is smaller than the experimental data by about 15%, with a 4.23 eV indirect band gap corresponding to Z → Γ and Z → β transitions. Three other indirect band gaps of 4.30 eV, 4.32 eV, and 4.36 eV are assigned to α3 → Γ, α1 → Γ, and α2 → Γ transitions, respectively. Δ-sol computations, on the other hand, predict a main band gap of 5.00 eV, just 50 meV above the experimental value. Electronic wavefunctions mainly originating from O 2p–carboxyl, C 2p–side chain, and C 2p–carboxyl orbitals contribute most significantly to the highest valence and lowest conduction energy bands, respectively. By varying the lattice parameters from their converged equilibrium values, we show that the unit cell is less stiff along the b direction than for the a and c directions. Effective mass calculations suggest that hole transport behavior is more anisotropic than electron transport, but the mass values allow for some charge mobility except along a direction perpendicular to the molecular layers of L-asparagine which form the crystal, so anhydrous monoclinic L-asparagine crystals could behave as wide gap semiconductors. Finally, the calculations point to a high degree of optical anisotropy for the absorption and complex dielectric function, with more structured curves for incident light polarized along the 100 and 101 directions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomalies in the polariton dynamics of a one-dimensional magnetic photonic crystal with antiferromagnetic interlayer ordering in an external DC electric field

The effect of an external dc electric field on the electrodynamic properties of a one-dimensional magnetic photonic crystal (MPC) with antiferromagnetic interlayer ordering is analyzed within the effective-medium method with regard to the quadratic magneto-optical interaction. The magnetizations of adjacent tangentially magnetized ferromagnetic layers are antiparallel. In particular, the effect of a magnetic compensation point on the character of polariton dynamics in this type of MPCs is revealed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solubility of oxygen in CdS single crystals and their physicochemical properties

The specific features of oxygen dissolution in CdS using the example of single crystals grown by the gas-transport method with deviations from stoichiometry at 1100°C are considered. The effect of various types of intrinsic point defects in crystals of different composition on the form in the presence of oxygen is analyzed. It is shown that the most stable composition thermodynamically is that corresponding to nonstoichiometric “self-activated cadmium sulphide” stabilized with oxygen.

36 MATERIALS SCIENCE↗

Initial Neutronics Analyses for HEU to LEU Fuel Conversion of the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory

The purpose of the TREAT reactor is to generate large transient neutron pulses in test samples without over-heating the core to simulate fuel assembly accident conditions. The power transients in the present HEU core are inherently self-limiting such that the core prevents itself from overheating even in the event of a reactivity insertion accident. The objective of this study was to support the assessment of the feasibility of the TREAT core conversion based on the present reactor performance metrics and the technical specifications of the HEU core. The LEU fuel assembly studied had the same overall design, materials (UO 2 particles finely dispersed in graphite) and impurities content as the HEU fuel assembly. The Monte Carlo N–Particle code (MCNP) and the point kinetics code TREKIN were used in the analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast method for reactor and feature scale coupling in ALD and CVD

Transport and surface chemistry of certain deposition techniques is modeled. Methods provide a model of the transport inside nanostructures as a single-particle discrete Markov chain process. This approach decouples the complexity of the surface chemistry from the transport model, thus allowing its application under general surface chemistry conditions, including atomic layer deposition (ALD) and chemical vapor deposition (CVD). Methods provide for determination of determine statistical information of the trajectory of individual molecules, such as the average interaction time or the number of wall collisions for molecules entering the nanostructures as well as to track the relative contributions to thin-film growth of different independent reaction pathways at each point of the feature.

36 MATERIALS SCIENCE↗

Beneficial effect of Se substitution on thermoelectric properties of Co{sub 4}Sb{sub 11.9-x}Te{sub x}Se{sub 0.1} skutterudites

Skutterudite-based compounds, Co{sub 4}Sb{sub 12-x-y}Te{sub x}Se{sub y} (x=0.4, 0.5, 0.6 and y=0.0, 0.1), are synthesized by the solid state reaction and the spark plasma sintering methods, and their structure and the thermoelectric properties have been investigated systematically. It is found that Se doping results in decrease of the lattice parameter and refinement of the particle size compared with those of Se-free samples. The Se-doped samples do not yield a certain increase in the power factor, but show a significant depression in the lattice thermal conductivity. The highest dimensionless figure of merit ZT=1.09 is achieved at 800 K for the Co{sub 4}Sb{sub 11.3}Te{sub 0.6}Se{sub 0.1} compound, which is improved by 15% compared with that of Te alone doped Co{sub 4}Sb{sub 11.4}Te{sub 0.6} compound at the corresponding temperature. - Graphical abstract: The Te and Se co-doped Co{sub 4}Sb{sub 11.9-x}Te{sub x}Se{sub 0.1} skutterudites show amazingly lower thermal conductivity ({kappa}) and lattice thermal conductivity ({kappa}{sub L}) compared with those of Co{sub 4}Sb{sub 12-x}Te{sub x} skutterudites. Highlights: Black-Right-Pointing-Pointer Te and Se co-doped Co{sub 4}Sb{sub 12-x-y}Te{sub x}Se{sub y} compounds have been synthesized by the solid state reaction method. Black-Right-Pointing-Pointer Doping of Se resulted in decrease of the lattice parameter and refinement of the particle size. Black-Right-Pointing-Pointer The co-doped skutterudites show amazingly lower lattice thermal conductivity. Black-Right-Pointing-Pointer Co-doping with Te and Se is an attractive approach to enhance the TE performance of skutterudites.

36 MATERIALS SCIENCE↗

Proton Minibeam Radiation Therapy Reduces Side Effects in an In Vivo Mouse Ear Model

Purpose: Proton minibeam radiation therapy is a novel approach to minimize normal tissue damage in the entrance channel by spatial fractionation while keeping tumor control through a homogeneous tumor dose using beam widening with an increasing track length. In the present study, the dose distributions for homogeneous broad beam and minibeam irradiation sessions were simulated. Also, in an animal study, acute normal tissue side effects of proton minibeam irradiation were compared with homogeneous irradiation in a tumor-free mouse ear model to account for the complex effects on the immune system and vasculature in an in vivo normal tissue model. Methods and Materials: At the ion microprobe SNAKE, 20-MeV protons were administered to the central part (7.2 × 7.2 mm{sup 2}) of the ear of BALB/c mice, using either a homogeneous field with a dose of 60 Gy or 16 minibeams with a nominal 6000 Gy (4 × 4 minibeams, size 0.18 × 0.18 mm{sup 2}, with a distance of 1.8 mm). The same average dose was used over the irradiated area. Results: No ear swelling or other skin reactions were observed at any point after minibeam irradiation. In contrast, significant ear swelling (up to fourfold), erythema, and desquamation developed in homogeneously irradiated ears 3 to 4 weeks after irradiation. Hair loss and the disappearance of sebaceous glands were only detected in the homogeneously irradiated fields. Conclusions: These results show that proton minibeam radiation therapy results in reduced adverse effects compared with conventional homogeneous broad-beam irradiation and, therefore, might have the potential to decrease the incidence of side effects resulting from clinical proton and/or heavy ion therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elucidation of perovskite film micro-orientations using two-photon total internal reflectance fluorescence microscopy

The emergence of efficient hybrid organic-inorganic perovskite photovoltaic materials has caused the rapid development of a variety of preparation and processing techniques designed to maximize their performance. As processing methods continue to emerge, it is important to understand how the optical properties of these materials are affected on a microscopic scale. Here polarization resolved two-photon total internal reflectance microscopy (TIRFM) was used to probe changes in transition dipole moment orientation as a function of thermal annealing time in hybrid organic-inorganic lead iodide based perovskite (CH 3 NH 3 PbI 3 ) thin films on glass. These results show that as thermal annealing time is increased the distribution of transition moments pointing out-of-plane decreases in favor of forming areas with increased in-plane orientations. As a result, it was also shown through the axial sensitivity of TIRFM that the surface topography is manifested in the signal intensity and can be used to survey aspects of morphology in coincidence with the optical properties of these films.

36 MATERIALS SCIENCE↗

Dynamics, Radiation, and Overall Energy Budget of Earthquake Rupture With Coseismic Off-Fault Damage

Earthquake ruptures dynamically activate coseismic off–fault damage around fault cores. Systematic field observation efforts have shown the distribution of off–fault damage around main faults, while numerical modeling using elastic–plastic off–fault material models have demonstrated the evolution of coseismic off–fault damage during earthquake ruptures. Laboratory–scale microearthquake experiments have pointed out the enhanced high–frequency radiation due to the coseismic off–fault damage. However, the detailed off–fault fracturing mechanisms, subsequent radiation, and its contribution to the overall energy budget remain to be fully understood because of limitations of current observational techniques and model formulations. Here, we constructed a new physics–based dynamic earthquake rupture modeling framework, based on the combined finite–discrete element method, to investigate the fundamental mechanisms of coseismic off–fault damage, and its effect on the rupture dynamics, the radiation and the overall energy budget. We conducted a 2–D systematic case study with depth and showed the mechanisms of dynamic activation of the coseismic off–fault damage. We found the decrease in rupture velocity and the enhanced high–frequency radiation in near field due to the coseismic off–fault damage. We then evaluated the overall energy budget, which shows a significant contribution of the coseismic off–fault damage to the overall energy budget even at depth, where the damage zone width becomes narrower. Here, the present numerical framework for the dynamic earthquake rupture modeling thus provides new insights into earthquake rupture dynamics with the coseismic off–fault damage.

58 GEOSCIENCES↗

Multilayered Al/CuO thermite formation by reactive magnetron sputtering: Nano versus micro

Multilayered Al/CuO thermite was deposited by a dc reactive magnetron sputtering method. Pure Al and Cu targets were used in argon-oxygen gas mixture plasma and with an oxygen partial pressure of 0.13 Pa. The process was designed to produce low stress (<50 MPa) multilayered nanoenergetic material, each layer being in the range of tens nanometer to one micron. The reaction temperature and heat of reaction were measured using differential scanning calorimetry and thermal analysis to compare nanostructured layered materials to microstructured materials. For the nanostructured multilayers, all the energy is released before the Al melting point. In the case of the microstructured samples at least 2/3 of the energy is released at higher temperatures, between 1036 and 1356 K.

36 MATERIALS SCIENCE↗

A study in three-dimensional chaotic dynamics: Granular flow and transport in a bi-axial spherical tumbler

We study three-dimensional (3D) chaotic dynamics through an analysis of transport in a granular flow in a half-full spherical tumbler rotated sequentially about two orthogonal axes (a bi-axial “blinking” tumbler). The flow is essentially quasi-two-dimensional in any vertical slice of the sphere during rotation about a single axis, and we provide an explicit exact solution to the model in this case. Hence, the cross-sectional flow can be represented by a twist map, allowing us to express the 3D flow as a linked twist map (LTM). We prove that if the rates of rotation about each axis are equal, then (in the absence of stochasticity) particle trajectories are restricted to two-dimensional (2D) surfaces consisting of a portion of a hemispherical shell closed by a “cap''; if the rotation rates are unequal, then particles can leave the surface they start on and traverse a volume of the tumbler. The period-one structures of the governing LTM are examined in detail: analytical expressions are provided for the location of period-one curves, their extent into the bulk of the granular material, and their dependence on the protocol parameters (rates and durations of rotations). Exploiting the restriction of trajectories to 2D surfaces in the case of equal rotation rates about the axes, a method is proposed for identifying and constructing 3D Kolmogorov--Arnold--Moser (KAM) tubes around the normally elliptic period-one curves. The invariant manifold structure arising from the normally hyperbolic period-one curves is also examined. When the motion is restricted to 2D surfaces, the structure of manifolds of the hyperbolic points in the bulk differs from that corresponding to hyperbolic points in the flowing layer. Each is reminiscent of a template provided by a non-integrable perturbation to a Hamiltonian system, though the governing LTM is not. This highlights the novel 3D chaotic behaviors observed in this model dynamical system.

42 ENGINEERING↗

Design Optimization of Liquid Fueled High Velocity Oxy- Fuel Thermal Spraying Technique for Durable Coating for Fossil Power Systems

High-velocity oxy–fuel (HVOF) thermal spraying was developed in 1930 and has been commercially available for twenty-five years. HVOF thermal spraying has several benefits over the more conventional plasma spray technique including a faster deposition rate which leads to quicker turn-around, with more durable coatings and higher bond strength, hardness and wear resistance due to a homogeneous distribution of the sprayed particles. HVOF thermal spraying is frequently used in engineering to deposit cermets, metallic alloys, composites and polymers, to enhance product life and performance. HVOF thermal spraying system is a highly promising technique for applying durable coatings on structural materials for corrosive and high temperature environments in advanced ultra-supercritical coal- fired (AUSC) boilers, steam turbines and gas turbines. HVOF thermal spraying is the preferred method for producing coatings with low porosity and high adhesion. HVOF thermal spray process has been shown to be one of the most efficient techniques to deposit high performance coatings at moderate cost. Variables affecting the deposit formation and coating properties include hardware characteristics such as nozzle geometry and spraying distance and process parameters such as equivalence ratio, gas flow density, and powder feedstock. In the spray process, the powder particles experience very high speeds combined with fast heating to the powder material melting point or above. This high temperature causes evaporation of the powder, dissolution, and phase transformations. Due to the complex nature of the HVOF technique, the control and optimization of the process is difficult. In general, good coating quality with suitable properties and required performance for specific applications is the goal in producing thermal spray coatings. In order to reach this goal, a deeper understanding of the spray process as a whole is needed. Although many researchers studied commercial HVOF thermal spray systems, there exists a lack of fundamental understanding of the effect of hardware characteristics and operating parameters on HVOF thermally sprayed coatings. Motivated by these issues, this study is devoted to investigate the effect of hardware characteristics (e.g. spraying distance) and operating parameters (e.g. combustion chamber pressure, equivalence ratio, and total gas flow rate) on HVOF sprayed coatings using Inconel 718 alloy. The current study provides extensive understanding of several key operating and process parameters to optimize the next generation of HVOF thermally sprayed coatings for high temperature and harsh environment applications. A facility was developed to support this endeavor in a safe and efficient way, including a HVOF thermal spray system with a Data Acquisition and Remote Controls system (DARCS). The coatings microstructure and morphology were examined using X-Ray Diffraction (XRD), Scanning Electron Microscope (SEM) and Nanoindentation.

20 FOSSIL-FUELED POWER PLANTS↗

Up-and-coming IMCs

While the good oxidation and environmental resistance, high melting points, and comparatively low densities of such ordered intermetallics as Ti3Al, NiAl, FeAl, and NbAl3 render them good candidates for advanced aerospace structures, their poor toughness at low temperatures and low strength at elevated temperatures have prompted the development of fiber-reinforced intermetallic-matrix composites (IMCs) with more balanced characteristics. Fabrication methods for continuous-fiber IMCs under development include the P/M 'powder cloth' method, the foil/fiber method, and thermal spraying. The ultimate success of IMCs depends on fibers truly compatible with the matrix materials.

Bowman, Randy↗

Optimization Shield Materials Trade Study for Lunar/Gateway Mission

The great cost of added radiation shielding is a potential limiting factor in many deep space missions. For this enabling technology, we are developing tools for optimized shield design over multi-segmented missions involving multiple work and living areas in the transport and duty phase of various space missions. The total shield mass over all pieces of equipment and habitats is optimized subject to career dose and dose rate constraints. Preliminary studies of deep space missions indicate that for long duration space missions, improved shield materials will be required. The details of this new method and its impact on space missions and other technologies will be discussed. This study will provide a vital tool for evaluating Gateway designs in their usage context. Providing protection against the hazards of space radiation is one of the challenges to the Gateway infrastructure designs. We will use the mission optimization software to scope the impact of Gateway operations on human exposures and the effectiveness of alternate shielding materials on Gateway infrastructure designs. It is being proposed to use Moon and the Lagrange points as the hub for deep space missions. This study will provide a guide to the effectiveness of multifunctional materials in preparation to more detailed geometry studies in progress.

Tripathi, R. K.↗

Chain Dynamics in Magnetorheological Suspensions

Magnetorheological (MR) suspensions are composed of colloidal particles which acquire dipole moments when subjected to an external magnetic field. At sufficient field strengths and concentrations, the dipolar particles rapidly aggregate to form long chains. Subsequent lateral cross-linking of the dipolar chains is responsible for a rapid liquid-to-solid-like rheological transition. The unique, magnetically-activated rheological properties of MR suspensions make them ideal for interfacing mechanical systems to electronic controls. Additionally, the ability to experimentally probe colloidal suspensions interacting through tunable anisotropic potentials is of fundamental interest. Our current experimental work has focused on understanding the fluctuations of dipolar chains. It has been proposed by Halsey and Toor (HT) that the strong Landau-Peierls thermal fluctuations of dipolar chains could be responsible for long-range attractions between chains. Such interactions will govern the long-time relaxation of MR suspensions. We have synthesized monodisperse neutrally buoyant MR suspensions by density matching stabilized ferrofluid emulsion droplets with D2O. This allows us to probe the dynamics of the dipolar chains using light scattering without gravitational, interfacial, and polydispersity effects to resolve the short-wavelength dynamics of the dipolar chains. We used diffusing wave spectroscopy to measure these dynamics. The particle displacements at short times that show an independence to the field strength, but at long times exhibit a constrained, sub-diffusive motion that slows as the dipole strength is increased. The experiments are in good qualitative agreement with Brownian dynamics simulations of dipolar chains. Although there have been several important and detailed studies of the structure and interactions in MR suspensions, there has not been conclusive evidence that supports or contradicts the HT model prediction that long-range interactions exist between fluctuating chains of dipolar particles. Resolving this issue would contribute greatly to the understanding of these interesting and important materials. We have begun to test the predictions of the HT model by both examining the dynamics of individual chains and by measuring the forces between dipolar chains directly to accurately and quantitatively assess the interactions that they experience. To do so, we employ optical trapping techniques and video-microscopy to manipulate and observe our samples on the microscopic level. With these techniques, it is possible to observe chains that are fluctuating freely in three-dimensions, independent of interfacial effects. More importantly, we are able to controllably observe the interactions of two chains at various separations to measure the force-distance profile. The techniques also allow us to study the mechanical properties of individual chains and chain clusters. Our work to this point has focused on reversibly-formed dipolar chains due to field induced dipoles where the combination of this chaining, the dipolar forces, and the hydrodynamic interactions that dictate the rheology of the suspensions. One can envision, however, many situations where optical, electronic, or rheological behavior may be optimized with magneto-responsive anisotropic particles. Chains of polarizable particles may have the best properties as they can coil and flex in the absence of a field and stiffen and orient when a field is applied. We have recently demonstrated a synthesis of stable, permanent paramagnetic chains by both covalently and physically linking paramagnetic colloidal particles. The method employed allows us to create monodisperse chains of controlled length. We observed the stability, field-alignment, and rigidity of this new class of materials. The chains may exhibit unique rheological properties in an applied magnetic field over isotropic suspensions of paramagnetic particles. They are also useful rheological models as bead-spring systems. These chains form the basis for our current experiments with optical traps.

Gast, A. P.↗

Thermal Hall effect in a van der Waals triangular magnet FeCL 2

Thermal transport is a pivotal probe for studying low-energy, charge-neutral quasiparticles in insulating magnets. In this Letter, we report an observation of large magnetothermal conductivity and thermal Hall effect (THE) in a van der Waals antiferromagnet FeCl 2 . The magnetothermal conductivity reaches over ~700%, indicating strong magnon-phonon coupling. Furthermore, we find an appreciable thermal Hall signal which changes sign concurrently with the spin-flip transition from the antiferromagnetic state to the polarized ferromagnetic state. Our theoretical calculations suggest that, in addition to the Berry curvature induced at the anticrossing points of the hybridized magnon and acoustic phonon modes of FeCl 2 , other mechanisms are needed to account for the magnitude of the observed THE.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the nonequilibrium concentration of vacancies in silicon crystals by measuring the concentration of nickel atoms at lattice sites

A method is proposed for determining the nonequilibrium concentration of vacancies and vacancy complexes in silicon crystals by measuring the concentration of electrically active nickel atoms at the sites of the silicon lattice, [Ni{sub s}], after the diffusion of nickel at temperatures from 550 to 650{sup o}C. It is shown experimentally that, after the diffusion of nickel from the surface into silicon samples with different initial nonequilibrium concentrations of vacancy complexes, [V]{sub init}, formed during crystal growth, the concentration [Ni{sub s}] in the bulk of a sample to a good degree of accuracy corresponds to the vacancy concentration [V]{sub init} determined by a standard method based on the analysis of the concentration profiles of [Au{sub s}] after the diffusion of gold from the surface. This method for determining the concentration of vacancies is much simpler than the standard method and allows one to use lower temperatures and a lower thermal budget.

36 MATERIALS SCIENCE↗

Can MRI be used to diagnose histologic grade in T1a (< 4 cm) clear cell renal cell carcinomas?

Objective: To assess whether MRI can differentiate low-grade from high-grade T1a cc-RCC. Materials and methods: With IRB approval, 49 consecutive solid < 4 cm cc-RCC (low grade [Grade 1 or 2] N = 38, high grade [Grade 3] N = 11) with pre-operative MRI before nephrectomy were identified between 2013 and 2018. Tumor size, apparent diffusion coefficient (ADC) histogram analysis, enhancement wash-in and wash-out rates, and chemical shift signal intensity index (SI index) were assessed by a blinded radiologist. Subjectively, two blinded Radiologists also assessed for (1) microscopic fat, (2) homogeneity (5-point Likert scale), and (3) ADC signal (relative to renal cortex); discrepancies were resolved by consensus. Outcomes were studied using Chi square, multivariate analysis, logistic regression modeling, and ROC. Inter-observer agreement was assessed using Cohen’s kappa. Results: Tumor size was 24 ± 7 (13–39) mm with no association to grade (p = 0.45). Among quantitative features studied, corticomedullary phase wash-in index (p = 0.015), SI index (p = 0.137), and tenth-centile ADC (p = 0.049) were higher in low-grade tumors. 36.8% (14/38) low-grade tumors versus zero high-grade tumors demonstrated microscopic fat (p = 0.015; Kappa = 0.67). Microscopic fat was specific for low-grade disease (100.0% [71.5–100.0]) with low sensitivity (36.8% [21.8–54.6]). Other subjective features did not differ between groups (p > 0.05). A logistic regression model combining microscopic fat + wash-in index + tenth-centile-ADC yielded area under ROC curve 0.98 (Confidence Intervals 0.94–1.0) with sensitivity/specificity 87.5%/100%. Conclusion: The combination of microscopic fat, higher corticomedullary phase wash-in and higher tenth-centile ADC is highly accurate for diagnosis of low-grade disease among T1a clear cell RCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refine your search to explore more results.