At least 1,801 records · Page 100

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

The Linear Point Standard Ruler with DESI DR1 and DR2 Data

The linear point, a purely geometric feature in the monopole of the two-point correlation function, has been proposed as an alternative standard ruler. Compared to the peak in the correlation function, it is more robust to late-time nonlinear effects at the percent level. In light of improved simulations and high quality data, we revisit the robustness of the linear point and use it as an alternative to template-based fitting approaches typically used in BAO analyses. We present the linear point measurements on galaxy samples from the first and second data releases (DR1 and DR2) of the DESI survey. We convert the linear point into a dimensionless parameter $α_{iso,LP}$, defined as the ratio of the linear point in the fiducial cosmology and the observed value, analogous to the isotropic BAO scaling parameter $α_{iso}$ used in previous BAO measurements. Using the 2nd generation of AbacusSummit mock catalogs, we find that linear point measurements are more precise when calculated in the post-reconstruction regime with 15-60% smaller uncertainties than those pre-reconstruction. We find a systematic shift in the linear point measurements compared against the isotropic BAO measurements in mocks; we attribute this to the isotropic damping parameter responsible for smearing the linear point in the nonlinear regime. We propose a sample-dependent correction that mitigates the impact of late-time nonlinear effects. While this introduces a cosmology dependence in an otherwise model-independent measurement, this is necessary given the sub-percent precision dictated by current cosmological surveys. Comparing $α_{iso,LP}$ with isotropic BAO measurements made on the DESI DR1 and DR2 galaxy samples, we find excellent agreement after applying this correction, particularly post-reconstruction. We discuss future scope regarding cosmological inference with linear point measurements.

Uberoi, N. [Yale U.] (ORCID:0000000275179629)↗

Influence of anomalous perpendicular transport on linear tearing mode dynamics in tokamak plasmas

The analysis of a previous paper [A. Cole and R. Fitzpatrick, Phys. Plasmas 13, 032503 (2006)] that maps out all of the two-fluid response regimes of a linear tearing layer interacting with an externally generated resonant magnetic perturbation, in a large aspect-ratio tokamak plasma, is generalized to take into account realistic levels of perpendicular particle transport. A new response-regime map is obtained that differs substantially, in many respects, from the old one. The improved analysis is first employed to find all of the two-fluid growth-rate regimes of a non-interacting low-mode-number tearing mode in a large aspect-ratio tokamak plasma. The analysis is then used to determine the scaling of the error-field penetration threshold with machine parameters in large aspect-ratio tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Forcing function effects on unsteady aerodynamic gust response. II - Low solidity airfoil row response

The paper investigates the fundamental gust modeling assumption on the basis of a series of experiments performed in the Purdue Annular Cascade Research Facility. The unsteady period flow field is generated by rotating flows of perforated plates and airfoil cascades, with the resulting unsteady periodic chordwise pressure response of a downstream low solidity stator row determined by miniature pressure transducers embedded within selected airfoils. When the forcing function exhibited the characteristics of a linear-theory gust, the resulting response on the downstream stator airfoils was in excellent agreement with the linear-theory models. When the forcing function did not exhibit linear-theory gust characteristics, the resulting unsteady aerodynamic response of the downstream stators was much more complex and correlated poorly with the linear-theory gust predictions. It is shown that the forcing function generator significantly affects the resulting gust response, with the complexity of the response characteristics increasing from the perforated-plate to the airfoil-cascade forcing functions.

Henderson, Gregory H.↗

Optimal sizing of battery energy storage systems for peak shaving and demand response using a degradation-aware Bayesian Optimization-Mixed-Integer Linear Programming framework

The increasing integration of renewable energy and rising electricity demand highlight the importance of battery energy storage systems for peak shaving and demand response. Unlike prior approaches that overlook operational impacts on degradation, this study proposes a Bayesian Optimization–Mixed Integer Linear Programming framework for optimal battery energy storage system sizing. In this framework, Mixed Integer Linear Programming determines short-term scheduling while a calibrated electrochemical model iteratively evaluates degradation. The central hypothesis is that the framework can efficiently identify optimal sizes that yield realistic and economically robust outcomes. The method is tested across three scenarios: peak shaving, peak shaving with energy-reduction demand response, and peak shaving with power-reduction demand response. Results show that the framework converge to the optimum within 20 iterations out of 150 possible sizes. Under baseline conditions, the framework consistently selects the smallest feasible system, minimizing unnecessary degradation costs from oversized storage. Sensitivity analyses reveal that larger systems are favored as demand rates or incentives increase. Comparisons of demand response programs indicate that power-reduction demand response offers greater economic benefits than energy-reduction demand response, although demand savings from peak shaving remain the dominant contributor to overall performance. This study demonstrates that the proposed framework balances computational tractability with degradation fidelity, identifies critical economic thresholds for investment, and offers a practical, flexible tool to guide industrial stakeholders in cost-effective battery energy storage system deployment.

Batteries↗

On the origins of the linear no-threshold (LNT) dogma by means of untruths, artful dodges and blind faith

This paper is an historical assessment of how prominent radiation geneticists in the United States during the 1940s and 1950s successfully worked to build acceptance for the linear no-threshold (LNT) dose–response model in risk assessment, significantly impacting environmental, occupational and medical exposure standards and practices to the present time. Detailed documentation indicates that actions taken in support of this policy revolution were ideologically driven and deliberately and deceptively misleading; that scientific records were artfully misrepresented; and that people and organizations in positions of public trust failed to perform the duties expected of them. Key activities are described and the roles of specific individuals are documented. These actions culminated in a 1956 report by a Genetics Panel of the U.S. National Academy of Sciences (NAS) on Biological Effects of Atomic Radiation (BEAR). In this report the Genetics Panel recommended that a linear dose response model be adopted for the purpose of risk assessment, a recommendation that was rapidly and widely promulgated. The paper argues that current international cancer risk assessment policies are based on fraudulent actions of the U.S. NAS BEAR I Committee, Genetics Panel and on the uncritical, unquestioning and blind-faith acceptance by regulatory agencies and the scientific community. - Highlights: • The 1956 recommendation of the US NAS to use the LNT for risk assessment was adopted worldwide. • This recommendation is based on a falsification of the research record and represents scientific misconduct. • The record misrepresented the magnitude of panelist disagreement of genetic risk from radiation. • These actions enhanced public acceptance of their risk assessment policy recommendations.

54 ENVIRONMENTAL SCIENCES↗

Further modeling of q 95 windows for the suppression of edge localized modes by resonant magnetic perturbations in the DIII-D tokamak

An improved resonant plasma response model that more accurately captures the physics of the interaction between a tokamak plasma and a resonant magnetic perturbation (RMP) is developed. The model interpolates between the linear and the nonlinear response regimes and takes into account the fact that the slip-frequency is non-zero in the nonlinear regime. The improved model is incorporated into the extended perturbed equilibrium code (EPEC) toroidal asymptotic matching code. The modified EPEC code is used to investigate RMP-induced edge-localized-mode (ELM) suppression in DIII-D H-mode discharge #145380. Somewhat surprisingly, allowing for a finite slip-frequency (i.e., relaxing the so-called no-slip constraint) is found to only slightly facilitate the locking of driven magnetic island chains to the RMP, and, hence, to only slightly facilitate RMP-induced ELM suppression. This is true despite the fact that the nature of non-locked island solutions is radically different when the no-slip constraint is imposed compared to when it is relaxed (in the first case, the widths of the island chains driven at the rational surfaces pulsate, and in the second case, they remain steady). The previously obtained conclusion that the response of a typical H-mode tokamak plasma to an RMP cannot be accurately modeled by linear theory is confirmed. Here, the previously obtained conclusion that the best agreement between theory and observations is achieved by assuming that the natural frequencies of tearing modes, in the absence of the RMP, are determined by the local equilibrium E × B velocity is also confirmed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT imaging. These findings may inform future studies of functional lung avoidance using V/Q PET/CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NREL's Improved Linearity Testing of Photovoltaic Reference Cells

Photovoltaic devices are characterized under standard testing conditions that include a defined reference spectrum and total irradiance. International standards for reference cell calibrations require that reported reference cell response (typically Isc) vs. total irradiance must be linear. How can linearity be efficiently determined? In 2006 NREL developed a test bed, based on the "two-lamp method" that provided a low cost, but low accuracy method for determining whether cell response was linear with irradiance. This paper describes very simple changes to NREL's historical method [1] for determining linearity that yield greatly improved results. It also describes a method that can be used to quantify and correct for non-linearity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Step Response Based Mixed-Signal BIST Approach for Continuous-time Linear Circuits

A new Mixed-Signal Built-in self-test approach that is based upon the step response of a reconfigurable (or multifunction) analog block is presented in this paper. The technique requires the overlapping step response of the Circuit Under Test (CUT) for two circuit configurations. Each configuration can be realized by changing the topology of the CUT or by sampling two CUT nodes with differing step responses. The technique can effectively detect both soft and hard faults and does not require an analog-to-digital converter (ADC) and/or digital-to-analog converter(DAC). It also does not require any precision voltage sources or comparators. This approach does not require any additional analog circuits to realize the test signal generator and sample circuits. The paper is concluded with the application of the proposed approach to a circuit found in the work of Epstein et al and two ITC 97 analog benchmark circuits.

Walker, Alvernon↗

SAR impulse response with residual chirps.

A Linear Frequency-Modulated (LFM) chirp is a function with unit amplitude and quadratic phase characteristic. In a focused Synthetic Aperture Radar (SAR) image, a residual chirp is undesired for targets of interest, as it coarsens the manifested resolution. However, for undesired spurious signals, a residual chirp is often advantageous because it spreads the energy and thereby diminishes its peak value. In either case, a good understanding of the effects of a residual LFM chirp on a SAR Impulse Response (IPR) is required to facilitate system analysis and design. This report presents an analysis of the effects of a residual chirp on the IPR. As reference, there is a rich body of publications on various aspects of LFM chirps. A quick search reveals a plethora of articles, going back to the early 1950s. We mention here purely as trivia one of the earlier analysis papers on this waveform by Klauder, et al.

47 OTHER INSTRUMENTATION↗

SU-C-207B-06: Comparison of Registration Methods for Modeling Pathologic Response of Esophageal Cancer to Chemoradiation Therapy

Purpose: To compare linear and deformable registration methods for evaluation of tumor response to Chemoradiation therapy (CRT) in patients with esophageal cancer. Methods: Linear and multi-resolution BSpline deformable registration were performed on Pre-Post-CRT CT/PET images of 20 patients with esophageal cancer. For both registration methods, we registered CT using Mean Square Error (MSE) metric, however to register PET we used transformation obtained using Mutual Information (MI) from the same CT due to being multi-modality. Similarity of Warped-CT/PET was quantitatively evaluated using Normalized Mutual Information and plausibility of DF was assessed using inverse consistency Error. To evaluate tumor response four groups of tumor features were examined: (1) Conventional PET/CT e.g. SUV, diameter (2) Clinical parameters e.g. TNM stage, histology (3)spatial-temporal PET features that describe intensity, texture and geometry of tumor (4)all features combined. Dominant features were identified using 10-fold cross-validation and Support Vector Machine (SVM) was deployed for tumor response prediction while the accuracy was evaluated by ROC Area Under Curve (AUC). Results: Average and standard deviation of Normalized mutual information for deformable registration using MSE was 0.2±0.054 and for linear registration was 0.1±0.026, showing higher NMI for deformable registration. Likewise for MI metric, deformable registration had 0.13±0.035 comparing to linear counterpart with 0.12±0.037. Inverse consistency error for deformable registration for MSE metric was 4.65±2.49 and for linear was 1.32±2.3 showing smaller value for linear registration. The same conclusion was obtained for MI in terms of inverse consistency error. AUC for both linear and deformable registration was 1 showing no absolute difference in terms of response evaluation. Conclusion: Deformable registration showed better NMI comparing to linear registration, however inverse consistency of transformation was lower in linear registration. We do not expect to see significant difference when warping PET images using deformable or linear registration. This work was supported in part by the National Cancer Institute Grants R01CA172638.

60 APPLIED LIFE SCIENCES↗

Cavity molecular dynamics simulations of vibrational polariton-enhanced molecular nonlinear absorption

We report recent experiments have observed that the chemical and photophysical properties of molecules can be modified inside an optical Fabry– Pérot microcavity under collective vibrational strong coupling (VSC) conditions, and such modification is currently not well understood by theory. In an effort to understand the origin of such cavity-induced phenomena, some recent studies have focused on the effect of the cavity environment on the nonlinear optical response of the molecular subsystem. Here, we use a recently proposed protocol for classical cavity molecular dynamics simulations to numerically investigate the linear and the nonlinear response of liquid carbon dioxide under such VSC conditions following an optical pulse excitation. We find that applying a strong pulse of excitation to the lower hybrid light–matter state, i.e., the lower polariton (LP), can lead to an overall molecular nonlinear absorption that is enhanced by up to two orders of magnitude relative to the excitation outside the cavity. This polariton-enhanced multiphoton absorption also causes an ultrashort LP lifetime (0.2 ps) under strong illumination. Unlike usual polariton relaxation processes—whereby polaritonic energy transfers directly to the manifold of singly excited vibrational dark states—under the present mechanism, the LP transfers energy directly to the manifold of higher vibrationally excited dark states; these highly excited dark states subsequently relax to the manifold of singly excited states with a lifetime of tens of ps. Because the present mechanism is generic in nature, we expect these numerical predictions to be experimentally observed in different molecular systems and in cavities with different volumes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE DISSIPATION OF SOLAR WIND TURBULENT FLUCTUATIONS AT ELECTRON SCALES

We present two-dimensional fully kinetic particle-in-cell simulations of decaying electromagnetic fluctuations. The computational box is such that wavelengths ranging from electron to ion gyroradii are resolved. The parameters used are realistic for the solar wind, and the ion-to-electron mass ratio is physical. The dissipation of turbulent fluctuations at small scales is thought to be a crucial mechanism for solar wind acceleration and coronal heating. The computational results suggest that a power-law cascade of magnetic fluctuations could be sustained up to scales of the electron Larmor radius and smaller. We analyze the simulation results in light of the Vlasov linear theory, and we comment on the particle heating. The dispersion curves of lightly damped modes in this regime suggest that a linear mechanism could be responsible for the observed steepening of power spectra at electron scales, but a straightforward identification of turbulent fluctuations as an ensemble of linear modes is not possible.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-C-18A-01: Models of Risk From Low-Dose Radiation Exposures: What Does the Evidence Say?

At dose levels of (approximately) 500 mSv or more, increased cancer incidence and mortality have been clearly demonstrated. However, at the low doses of radiation used in medical imaging, the relationship between dose and cancer risk is not well established. As such, assumptions about the shape of the dose-response curve are made. These assumptions, or risk models, are used to estimate potential long term effects. Common models include 1) the linear non-threshold (LNT) model, 2) threshold models with either a linear or curvilinear dose response above the threshold, and 3) a hormetic model, where the risk is initially decreased below background levels before increasing. The choice of model used when making radiation risk or protection calculations and decisions can have significant implications on public policy and health care decisions. However, the ongoing debate about which risk model best describes the dose-response relationship at low doses of radiation makes informed decision making difficult. This symposium will review the two fundamental approaches to determining the risk associated with low doses of ionizing radiation, namely radiation epidemiology and radiation biology. The strengths and limitations of each approach will be reviewed, the results of recent studies presented, and the appropriateness of different risk models for various real world scenarios discussed. Examples of well-designed and poorly-designed studies will be provided to assist medical physicists in 1) critically evaluating publications in the field and 2) communicating accurate information to medical professionals, patients, and members of the general public. Equipped with the best information that radiation epidemiology and radiation biology can currently provide, and an understanding of the limitations of such information, individuals and organizations will be able to make more informed decisions regarding questions such as 1) how much shielding to install at medical facilities, 2) at what dose level are risk vs. benefit discussions with patients appropriate, 3) at what dose level should we tell a pregnant woman that the baby’s health risk from a prenatal radiation exposure is “significant”, 4) is informed consent needed for patients undergoing medical imaging, and 5) at what dose level is evacuation appropriate after a radiological accident. Examples of the tremendous impact that choosing different risks models can have on the answers to these types of questions will be given.A moderated panel discussion will allow audience members to pose questions to the faculty members, each of whom is an established expert in his respective discipline. Learning Objectives: Understand the fundamental principles, strengths and limitations of radiation epidemiology and radiation biology for determining the risk from exposures to low doses of ionizing radiation Become familiar with common models of risk used to describe the dose-response relationship at low dose levels Learn to identify strengths and weaknesses in studies designed to measure the effect of low doses of ionizing radiation Understand the implications of different risk models on public policy and health care decisions.

60 APPLIED LIFE SCIENCES↗

Motor function in microgravity: movement in weightlessness

Microgravity provides unique, though experimentally challenging, opportunities to study motor control. A traditional research focus has been the effects of linear acceleration on vestibular responses to angular acceleration. Evidence is accumulating that the high-frequency vestibulo-ocular reflex (VOR) is not affected by transitions from a 1 g linear force field to microgravity (<1 g); however, it appears that the three-dimensional organization of the VOR is dependent on gravitoinertial force levels. Some of the observed effects of microgravity on head and arm movement control appear to depend on the previously undetected inputs of cervical and brachial proprioception, which change almost immediately in response to alterations in background force levels. Recent studies of post-flight disturbances of posture and locomotion are revealing sensorimotor mechanisms that adjust over periods ranging from hours to weeks.

NASA Program Flight↗

Refine your search to explore more results.