Search NASA⌕ Search

SEARCH · Search NASA

Results for “ALARM SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target vessel shielded with {sup 6}Li-rich plastic, a hydrogen fill/vent line with a passive recirculation loop to establish and maintain the equilibrium ortho-para ratio, a hydrogen relief system coupled to a vent stack, a gas handling system, and an alarm and interlock system. Low Z, nonmagnetic materials were used for the target vessel and cryostat. Pressure and temperature sensors monitored the thermodynamic state of the target. Relative neutron transmission measurements were used to monitor the parahydrogen fraction of the target. The target was thoroughly tested and successfully operated during the first phase of the NPDGamma experiment conducted at the FP12 beam line at Los Alamos Neutron Science Center (LANSCE). An upgraded version of the target system will be used in the next stage of the experiment, which will be performed at the Fundamental Neutron Physics Beam (FnPB) line of the Spallation Neutron Source at Oak Ridge National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mining Building Energy Management System Data Using Fuzzy Anomaly Detection and Linguistic Descriptions

Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD) based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predictive Modeling of Cardiac Ischemia

The goal of the Contextual Alarms Management System (CALMS) project is to develop sophisticated models to predict the onset of clinical cardiac ischemia before it occurs. The system will continuously monitor cardiac patients and set off an alarm when they appear about to suffer an ischemic episode. The models take as inputs information from patient history and combine it with continuously updated information extracted from blood pressure, oxygen saturation and ECG lines. Expert system, statistical, neural network and rough set methodologies are then used to forecast the onset of clinical ischemia before it transpires, thus allowing early intervention aimed at preventing morbid complications from occurring. The models will differ from previous attempts by including combinations of continuous and discrete inputs. A commercial medical instrumentation and software company has invested funds in the project with a goal of commercialization of the technology. The end product will be a system that analyzes physiologic parameters and produces an alarm when myocardial ischemia is present. If proven feasible, a CALMS-based system will be added to existing heart monitoring hardware.

Anderson, Gary T.↗

A State-Space Approach to Optimal Level-Crossing Prediction for Linear Gaussian Processes

In many complex engineered systems, the ability to give an alarm prior to impending critical events is of great importance. These critical events may have varying degrees of severity, and in fact they may occur during normal system operation. In this article, we investigate approximations to theoretically optimal methods of designing alarm systems for the prediction of level-crossings by a zero-mean stationary linear dynamic system driven by Gaussian noise. An optimal alarm system is designed to elicit the fewest false alarms for a fixed detection probability. This work introduces the use of Kalman filtering in tandem with the optimal level-crossing problem. It is shown that there is a negligible loss in overall accuracy when using approximations to the theoretically optimal predictor, at the advantage of greatly reduced computational complexity. I

Martin, Rodney Alexander↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2003 Hanford Site Annual Illness and Injury Surveillance Report, Revised October 2007

Annual Illness and Injury Surveillance Program report for the Hanford site. The IISP monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers. The prpogram is part of DOE's commitment to assuring the health and safety of its workers and includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers.

54 ENVIRONMENTAL SCIENCES↗

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

Development and Demonstration of a Security Core Component

In recent years, the convergence of a number of trends has resulted in Cyber Security becoming a much greater concern for electric utilities. A short list of these trends includes: · Industrial Control Systems (ICSs) have evolved from depending on proprietary hardware and operating software toward using standard off-the-shelf hardware and operating software. This has meant that these ICSs can no longer depend on “security through obscurity. · Similarly, these same systems have evolved toward using standard communications protocols, further reducing their ability to rely upon obscurity. · The rise of the Internet and the accompanying demand for more data about virtually everything has resulted in formerly isolated ICSs becoming at least partially accessible via Internet-connected networks. · “Cyber crime” has become commonplace, whether it be for industrial espionage, reconnaissance for a possible cyber attack, theft, or because some individual or group “has something to prove.” Electric utility system operators are experts at running the power grid. The reality is, especially at small and mid-sized utilities, these SCADA operators will by default be “on the front line” if and when a cyber attack occurs against their systems. These people are not computer software, networking, or cyber security experts, so they are ill-equipped to deal with a cyber security incident. Cyber Security Manager (CSM) was conceived, designed, and built so that it can be configured to know what a utility’s SCADA/EMS/DMS system looks like under normal conditions. To do this, CSM monitors log messages from any device that uses the syslog standard. It can also monitor a variety of statistics from the computers that make up the SCADA/EMS/DMS: outputs from host-based security tools, intrusion detection systems, SCADA alarms, and real-time SCADA values – even results from a SIEM (Security Information and Event Management) system. When the system deviates from “normal,” CSM can alert the operator in language that they understand that an incident may be occurring, provide actionable intelligence, and informing them what actions to take. These alarms may be viewed on CSM’s built-in user interface, sent to a SCADA alarm list, or communicated via email, phone, pager, or SMS message. In recognition of the fact that “real world” training for cyber security events is impractical, CSM has a built-in Operator Training Simulator capability. This can be used stand alone to create simulated event scenarios for training purposes. It may also be used in conjunction with the recipient’s SCADA/EMS/DMS Operator Training Simulator. In addition to providing cyber security situational awareness for electric utility operators, CSM also provides tools for analysts and support personnel; in fact, the majority of user interface displays are designed for use in analyzing current and past security events. CSM keeps security-related information in long-term storage, as well as writing any decisions it makes to a (syslog) log for use forensic or other post-event analysis.

Turke, Andy↗

Antenna Requirements for GMTI Radar Systems

A principal performance-enabling, or performance-limiting, component of Ground-Moving-Target-Indication (GMTI) radar systems is the antenna. Undesired clutter leakage into antenna sidelobes can be particularly problematic, generating undesired false alarms. GMTI system antennas can be designed with characteristics and features to allow discriminating and depressing/suppressing problematic sidelobe leakage of clutter and other undesired signals. We offer analysis and design guidelines for doing so.

42 ENGINEERING↗

Automatic patient respiration failure detection system with wireless transmission

Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

Dimeff, J.↗

ALARM STRATEGY AND COMPLEXITY: PREDICTIONS OF OPERATOR RESPONSE

Decision support for operators is not new, and much has been written regarding the potential usefulness of digital support systems and alarm filtering strategies. However, determining the appropriate characteristics of decision support tools is difficult, especially when alarms can vary in the manner which diagnostic information is formulated and displayed and when event scenario types are complex and numerous. When first reviewed, the advantages or disadvantages of a particular alarm approach may not be apparent to the designer or analyst. The present research focuses on the review of two particular alarm strategies, binary alarm type (BAT) and likelihood alarm type (LAT), and reviews their influence upon accuracy, bias, and trust for tasks performed at a computer workstation capable of replicating a series of control-room-like alarms. The findings are discussed in terms of the of the performance advantages of likelihood alarm technology and related research as an aid to the alarm design process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tsunamis warning from space :Ionosphere seismology [Slides]

Ionosphere is the layer of the atmosphere from about 85 to 600km containing electrons and electrically charged atoms that are produced by solar radiation. Perturbations - layering affected by day and night, X-rays and high-energy protons from the solar flares, geomagnetic storms, lightning, drivers-from-below. Strategic for radio-wave transmission. This project discusses the inversion of ionosphere signals, tsunami wave amplitude and coupling parameters, which improves tsunami warning systems.

58 GEOSCIENCES↗

Assessing potential impacts associated with contamination events in water distribution systems : a sensitivity analysis.

An understanding of the nature of the adverse effects that could be associated with contamination events in water distribution systems is necessary for carrying out vulnerability analyses and designing contamination warning systems. This study examines the adverse effects of contamination events using models for 12 actual water systems that serve populations ranging from about 104 to over 106 persons. The measure of adverse effects that we use is the number of people who are exposed to a contaminant above some dose level due to ingestion of contaminated tap water. For this study the number of such people defines the impact associated with an event. We consider a wide range of dose levels in order to accommodate a wide range of potential contaminants. For a particular contaminant, dose level can be related to a health effects level. For example, a dose level could correspond to the median lethal dose, i.e., the dose that would be fatal to 50% of the exposed population. Highly toxic contaminants may be associated with a particular response at a very low dose level, whereas contaminants with low toxicity may only be associated with the same response at a much higher dose level. This report focuses on the sensitivity of impacts to five factors that either define the nature of a contamination event or involve assumptions that are used in assessing exposure to the contaminant: (1) duration of contaminant injection, (2) time of contaminant injection, (3) quantity or mass of contaminant injected, (4) population distribution in the water distribution system, and (5) the ingestion pattern of the potentially exposed population. For each of these factors, the sensitivities of impacts to injection location and contaminant toxicity are also examined. For all the factors considered, sensitivity tends to increase with dose level (i.e., decreasing toxicity) of the contaminant, with considerable inter-network variability. With the exception of the population distribution (factor 4 above), sensitivity to the various factors tends to be highest at lower impact levels (e.g., impacts below the 80th percentile). Conversely, for the population distribution factor, sensitivity is lowest at the lower impact levels. For injection duration, impacts generally are higher for longer duration injections. Definite patterns are present in the sensitivity of impacts to injection time, but these vary substantially across the networks. As would be expected, impacts are larger for larger mass injections, but the sensitivity can vary dramatically depending on dose level and the network. Estimated impacts can be sensitive to assumptions about how population is distributed in a network, particularly at high impact levels and high dose levels, again with considerable variability across networks. Finally, impacts can be sensitive to assumptions about ingestion patterns in the potentially exposed population, with sensitivities varying across networks and tending to be highest for high dose levels. When considered in combination with the other factors (but not including the ingestion model used), impacts at low dose levels (levels at which the effects of highly toxic contaminants can be significant) are most sensitive to injection duration. Similarly, when considered in combination, impacts at higher dose levels (levels required for significant effects from contaminants with low toxicity) are most sensitive to injection mass. At low dose levels, for a likely range in injection masses, impacts are not particularly sensitive to injection mass. The influence of the various factors on the location of high percentile injection locations can be as important or more important than their influence on the magnitudes of impacts. In addition, the choice of contaminant has a major influence on which nodes are high impact injection locations. The sharing (overlap) of the same high-percentile injection nodes for different values of a factor can vary substantially by contaminant and impact level (percentile of impact). Overlap tends to decrease with decreasing toxicity of the contaminant and increasing impact level for all the factors considered, with considerable variability among the networks. Our results demonstrate the great variability in the impacts and the sensitivity of impacts to various factors that can occur in different water systems during a contamination event. Although definite patterns exist in the nature and magnitude of impacts and sensitivities for the diverse set of water systems examined, these results also show that substantial inter-network variability limits the ability to predict or extrapolate these results to other systems. Therefore, although water systems do exhibit some similarities in the magnitude and pattern of impacts during contamination events, each individual water system should be treated as unique.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of ASGARD and UFOCapture

The Meteoroid Environment Office is undertaking a comparison between UFOCapture/Analyzer and ASGARD (All Sky and Guided Automatic Realtime Detection). To accomplish this, video output from a Watec video camera on a 17 mm Schneider lens (25 degree field of view) was split and input into the two different meteor detection softwares. The purpose of this study is to compare the sensitivity of the two systems, false alarm rates and trajectory information, among other quantities. The important components of each software will be highlighted and comments made about the detection/rejection algorithms and the amount of user-labor required for each system.

Blaauw, Rhiannon C.↗

Integrating event detection system operation characteristics into sensor placement optimization.

We consider the problem of placing sensors in a municipal water network when we can choose both the location of sensors and the sensitivity and specificity of the contamination warning system. Sensor stations in a municipal water distribution network continuously send sensor output information to a centralized computing facility, and event detection systems at the control center determine when to signal an anomaly worthy of response. Although most sensor placement research has assumed perfect anomaly detection, signal analysis software has parameters that control the tradeoff between false alarms and false negatives. We describe a nonlinear sensor placement formulation, which we heuristically optimize with a linear approximation that can be solved as a mixed-integer linear program. We report the results of initial experiments on a real network and discuss tradeoffs between early detection of contamination incidents, and control of false alarms.

54 ENVIRONMENTAL SCIENCES↗