Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Search for Electromagnetic Alteration of 235m U Decay

Electromagnetic modification of the 235m U isomer has been tested by placing the decaying system in a number of different environments. The isomer decays by internal conversion, which involves the electromagnetic transfer of energy from the nucleus to an atomic electron, and it is expected that this process can be altered by changing the photon density of states available to the nucleus. The two approaches pursued during this work included direct detection of the electron produced by the isomer decay using a micro-channel plate detector, and detection of the scintillation light produced when the electron interacted with various scintillators. With direct electron detection, variations in the isomer population were observed before and after covering the isomer, but this effect is attributed to systematic errors associated with the implantation and covering process. With the scintillator approach, scintillation light from the decay of the isomer was measured for the first time, and the decay half-life was directly identified while the isomer was embedded in a bulk material. No modification was observed, which leads to the conclusion that internal conversion of 235m U does not depend on the index of refraction of the surrounding environment in the way that spontaneous photon emission of an atomic system does. This result excludes many of the interesting applications of electromagnetic alteration of nuclear decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Book Review: Monitoring compliance with the comprehensive Nuclear-Test-Ban Treaty (CTBT). Contributions by the German national data centre edited by Christoph Pilger, Lars Ceranna and Christian Bönnemann

For decades, the nuclear weapons capability of different countries was tracked in part via the interpretation of signals from more than 2000 nuclear test explosions that were conducted in programs of weapons development. The first such explosion took place in July 1945 (in New Mexico, USA, prior to the use of nuclear weapons in World War 2 against Japan). The last nuclear test, prior to the Comprehensive Nuclear-Test-Ban Treaty (CTBT) becoming open for signature in September 1996, was in July 1996 (in China). This treaty, which took nearly forty years to negotiate, has been signed by 184 states as of December 2018, but a few key additional signatures and ratifications are still needed before nuclear tests are banned under international law. The evidence that a nuclear test explosion has occurred can come from electromagnetic, seismic, hydroacoustic, and infrasonic waves; and from unusual radionuclides— which can be present in particulate matter and/or as noble gases. Of course there is a vast infrastructure associated with military programs of nuclear weapons development in a limited number of countries. Less well-known, is the existence of a large infrastructure involving national and international efforts to monitor for the possible occurrence of nuclear test explosions, and thus to support CTBT verification. This book does a very good job of explaining much of that work, as it is conducted in practice by a western nation with sophisticated facilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Wireless Monitoring Study in the Meuse / Haute-Marne Underground Research Laboratory, France - 12046

Two types of wireless transmission systems using ultra low frequency (8.5 kHz) were developed and used in the Callovo-Oxfordian argillites layer in the Meuse / Haute-Marne Underground Research Laboratory (CMHM URL) in France. Short-range and mid-range transmission antennas received data transmitted from 25 m to 50 m away. From the results of two series of tests, it is clear that transmission is practical when the received voltage is larger than the received noise. However, it is also clear that wireless transmission in the CMHM URL gallery is affected by the electromagnetic noise level and steel components, and the maximum transmission distance depends on the S/N ratio. The mid-range transmission antenna achieved a transmission distance of 240 m in the surface test, where the electromagnetic noise level was small and there was no environmental attenuation. The short-range transmission antenna achieved a transmission distance of 25 m in the surface test and in the CMHM URL gallery. As the clay layer of the CMHM URL had little effect on the attenuation of the electromagnetic field, transmission over 200 m might be possible in the CMHM URL when the electromagnetic noise level is small enough and there are no significant factors enhancing attenuation. But in reality, the possible transmission distance was around 50 m. In order to show the transmitter's ability, it is preferable to keep some distance between steel components and the transmitter. The most effective way to use this transmitter is to put it in a borehole drilled from a gallery to outside of a gallery around 10 m length. In this way, it might be possible to avoid almost of all the influence of steel components. For the position of receiver, the recommendation is the same as for the transmitter. That is, place the receiver where the incoming signal from the transmitter suffers little attenuation from steel components. Therefore, the option of implementing a receiving antenna in a borehole is required. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Note: Enhanced production of He{sup +} from the Versatile Ion Source (VIS) in off-resonance configuration

The Versatile Ion Source (VIS) is a microwave discharge ion source installed at INFN-LNS and here used as test-bench for the production of high intensity low emittance proton beams and for studies on plasma physics. A series of measurements have been carried out with VIS in order to test the source with light ions. In particular a He{sup +} beam has been characterized in terms of plasma discharge parameters. The experiment has been triggered by the observation of X-radiation emission from the plasma for some configuration of the magnetic field profile. The plasma electron energy distribution function is in fact modified when in some regions of the plasma chamber under-resonance discharge takes place, fulfilling the condition that allows the electromagnetic wave to electrostatic wave conversion. These tests allowed obtaining more than 50 mA of He{sup +} beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of inductively coupled Eddy current position sensor of diverse safety rod in sodium

Prototype Fast Breeder Reactor (PFBR) is 500 MWe sodium cooled reactor under construction at Kalpakkam (India)). To improve the reliability of shutdown, Diverse Safety Rods (DSRs) are used in-addition to normal Control and Safety rods. During reactor operating condition, the DSR is parked above the active core and held in its top position by an electromagnet. In the event of a scram signal from the safety logic, the electromagnet holding the DSR is de-energised. Hence the DSR is released into the active core and at the end of travel DSR gets deposited in its bottom position. Because of the mechanical constraints, hard wired connectivity is not permitted from the DSR subassembly to the instrumentation outside the reactor. Hence an inductively coupled Eddy Current Position Sensor (ECPS) has been conceptualized to detect that the DSR has reached its bottom most position and to measure the drop time. Results of feasibility study on laboratory model have been reported earlier. Testing of a 1:1 scale engineering model of ECPS is reported in this paper. Results obtained from the high temperature sodium testing of ECPS indicate a clearly measurable change in pick up voltage with sensitivity of 11 % at 675 Hz. The ECPS is in advanced stage of implementation in DSRDM of PFBR. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Massive Gas Injection Valve Development for NSTX-U

NSTX-U research will offer new insight by studying gas assimilation efficiencies for MGI injection from different poloidal locations using identical gas injection systems. In support of this activity, an electromagnetic MGI valve has been built and tested. The valve operates by repelling two conductive disks due to eddy currents induced on them by a rapidly changing magnetic field created by a pancake disk solenoid positioned beneath the circular disk attached to a piston. The current is driven in opposite directions in the two solenoids, which creates a cancelling torque when the valve is operated in an ambient magnetic field, as would be required in a tokamak installation. The valve does not use ferromagnetic materials. Results from the operation of the valve, including tests conducted in 1 T external magnetic fields, are described. The pressure rise in the test chamber is measured directly using a fast time response baratron gauge. At a plenum pressure of just 1.38 MPa (~200 psig), the valve injects 27 Pa.m^3 (~200 Torr.L) of nitrogen with a pressure rise time of 3 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ten Trials at Lower Slobbovia: Searching for Repetitive Electromagnetic and Seismoacoustic Signatures in Explosions

We performed a series of ten explosion tests, each test being a single 10-kg cylinder of Comp-B with a PBXN-9 booster. Eight of the tests were placed 2 m above ground level, one was at ground level, and one was 1 m below ground in a backfilled hole. The explosions were monitored by radio antennas to detect electromagnetic emissions and seismo-acoustic instrumentation. We found that certain aspects of the radiofrequency emission regimes repeated from test to test. Some features showed a systematic variation across tests, which we interpret as the effect of each detonation on the nearby ground. The radio emissions were probably from the high-temperature detonation shock, follow-on combustion, and frictional charging of dirt entrained by the blast. The below-ground test in particular generated an anomalously-high level of RF at both low and high frequencies, presumably due to the large amount of dirt and rock involved. The seismoacoustic observations clearly discriminate the buried shot from the table and surface shots, which appear as a single population. Seismoacoustic waveforms from repeating tests at local distances have highly self-similar waveforms but amplitudes are strongly dependent on atmospheric conditions. We show that we can correct for meteorological effects on amplitude for upward-refracting atmospheres, but that correction for downward-refracting atmospheric profiles requires a coupled correction for topography.

47 OTHER INSTRUMENTATION↗

Test beam results of micro channel plates in 'ionisation mode' for the detection of single charged particle and electromagnetic showers

IMCP is an R and D project aimed at the exploitation of secondary emission of electrons from the surface of microchannel plates (MCP) for fast timing of showers in high rate environments. The usage of MCPs in 'ionisation' mode has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The fast time resolution of MCPs exceeds anything that has been previously used in calorimeters, and, if exploited effectively, could aid in the event reconstruction at high luminosities. Results from tests with electrons with energies up to 150 GeV of MCP devices with different characteristics will be presented, in particular detection efficiency and time resolution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full electromagnetic Vlasov code simulation of the Kelvin-Helmholtz instability

Recent advancement in numerical techniques for Vlasov simulations and their application to cross-scale coupling in the plasma universe are discussed. Magnetohydrodynamic (MHD) simulations are now widely used for numerical modeling of global and macroscopic phenomena. In the framework of the MHD approximation, however, diffusion coefficients such as resistivity and adiabatic index are given from empirical models. Thus there are recent attempts to understand first-principle kinetic processes in macroscopic phenomena, such as magnetic reconnection and the Kelvin-Helmholtz (KH) instability via full kinetic particle-in-cell and Vlasov codes. In the present study, a benchmark test for a new four-dimensional full electromagnetic Vlasov code is performed. First, the computational speed of the Vlasov code is measured and a linear performance scaling is obtained on a massively parallel supercomputer with more than 12 000 cores. Second, a first-principle Vlasov simulation of the KH instability is performed in order to evaluate current status of numerical techniques for Vlasov simulations. The KH instability is usually adopted as a benchmark test problem for guiding-center Vlasov codes, in which a cyclotron motion of charged particles is neglected. There is not any full electromagnetic Vlasov simulation of the KH instability; this is because it is difficult to follow E-vectorxB-vector drift motion accurately without approximations. The present first-principle Vlasov simulation has successfully represented the formation of KH vortices and its secondary instability. These results suggest that Vlasov code simulations would be a powerful approach for studies of cross-scale coupling on future Peta-scale supercomputers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic and gravitational interactions from Lagrangian mechanics

Highlights: • Background Maxwell and Einstein fields are universal features of Lagrangian systems. • The Lagrangian function is promoted to a dynamic field. • The Einstein–Maxwell theory is derived from Lagrangian mechanics. Background fields of electromagnetic and gravitational type emerge in the low kinetic energy limit of any regular Lagrangian system and, in particular, in the corresponding limit of any spacetime theory in which the free motion of test particles is described by an unspecified regular Lagrangian. Electromagnetic and gravitational type interactions are therefore a universal feature of low kinetic energy Lagrangian systems. These background interactions can be consistently turned into dynamic Einstein–Maxwell fields by promoting the Lagrangian function to a dynamic scalar field on the tangent bundle of the configuration space. Accordingly, Einstein–Maxwell theory can be deduced from the assumption that the motion of elementary test particles in spacetime is described by Lagrangian mechanics. For higher kinetic energy-type values, identified with the square of the invariant mass of the particle, the Lagrangian induces higher rank interactions that seem however too weak to have been detected in spacetime physics, but which might prove relevant at the Planck scale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tevatron Resistive Wall Current Monitor

Resistive Wall Current Monitors (RWCM) were designed and built for the Fermilab Tevatron (Tev) project. These devices measure longitudinal beam current from 3 KHz to 6 GHz with 1.34 ohm gap impedance. There are two RWCM's installed a few feet apart in the Tevatron, upstream RWCM is used for general purpose use, downstream RWCM is dedicated for longitudinal parameters of coalesced beam bunches and bunch intensities. The design provides a calibration or test port for injecting test signals. Microwave absorber material is used to reduce interference from spurious electromagnetic waves traveling inside the beam pipe. This paper will do an overview how the RWCM was designed and its test results.

43 PARTICLE ACCELERATORS↗

Charged Wellbore Casing Controlled Source Electromagnetics (CWC-CSEM) for Reservoir Imaging and Monitoring (Final report)

This project addresses the needs of the U.S. Department of Energy (DOE) to develop advanced monitoring technologies and protocols to track the fate of subsurface carbon dioxide (CO2) plumes for carbon storage. Specifically, the project seeks to develop and test a unique and novel system of technologies consisting of electromagnetic data acquisition, coupled multiphysics imaging, and reservoir model enhancement to understand the migration and long-term distribution of CO2 in the subsurface. The overarching objective is to develop an integrated approach for long term monitoring of carbon storage. The two main components of the project include the methodology development and the test of the method at a field site. The methodology component consists of 1) developing the field procedure and protocol for collecting time-lapse controlled-source electromagnetic (CSEM) data with source electric current injected into the subsurface through wellbore casings; 2) building of background 3D electrical conductivity utilizing multiple sources of data such as supplemental surface transient EM (TEM) surveys, well-logs, and seismic structural information, for enhancing CSEM signal from reservoir depths; and 3) coupled multiphysics simulations and inversion of CSEM data constrained by production data and by structural information from seismic imaging of the reservoir and overlying formations. The testing component used the field site of Bell Creek Oil Field, which served both as a field laboratory for the method development as well as a test site to evaluate the CSEM signal strengths and the methodology developed in this research project. We have accomplished all the proposed tasks and developed the methodology as planned. These include the procedure for time-lapse CSEM data acquisition, data processing techniques, integration with 3D conductivity model building, fast reservoir simulation for history matching using machine learning, and interpreting CSEM data with coupling to the reservoir modeling. Collectively, the outcome of these tasks form a coherent workflow that can be applied to monitor dedicated carbon storage in saline reservoirs. The testing component evaluated the applicability and limitations of the method, and concluded that the method would be ideal for monitoring dedicated carbon storage sites utilizing saline reservoirs.

54 ENVIRONMENTAL SCIENCES↗

Propagation of radiation in fluctuating multiscale plasmas. II. Kinetic simulations

A numerical algorithm is developed and tested that implements the kinetic treatment of electromagnetic radiation propagating through plasmas whose properties have small scale fluctuations, which was developed in a companion paper. This method incorporates the effects of refraction, damping, mode structure, and other aspects of large-scale propagation of electromagnetic waves on the distribution function of quanta in position and wave vector, with small-scale effects of nonuniformities, including scattering and mode conversion approximated as causing drift and diffusion in wave vector. Numerical solution of the kinetic equation yields the distribution function of radiation quanta in space, time, and wave vector. Simulations verify the convergence, accuracy, and speed of the methods used to treat each term in the equation. The simulations also illustrate the main physical effects and place the results in a form that can be used in future applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simple scalings for various regimes of electron acceleration in surface plasma waves

Different electron acceleration regimes in the evanescent field of a surface plasma wave are studied by considering the interaction of a test electron with the high-frequency electromagnetic field of a surface wave. The non-relativistic and relativistic limits are investigated. Simple scalings are found demonstrating the possibility to achieve an efficient conversion of the surface wave field energy into electron kinetic energy. This mechanism of electron acceleration can provide a high-frequency pulsed source of relativistic electrons with a well defined energy. In the relativistic limit, the most energetic electrons are obtained in the so-called electromagnetic regime for surface waves. In this regime, the particles are accelerated to velocities larger than the wave phase velocity, mainly in the direction parallel to the plasma-vacuum interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗