Search NASA⌕ Search

SEARCH · Search NASA

Results for “FATIGUE TESTING MACHINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

184 records · Page 11

An Eddy Current Case Study using NASA’s Transfer Function and Limited-Sample Probability of Detection Guidebooks

Probability of detection (POD) requirements for NASA fracture-critical human-rated systems can be met by (1) claiming ‘similarity’ to NASA Standard Nondestructive Evaluation (NDE) flaw sizes or (2) by inspector-specific POD demonstration, known as NASA Special NDE. Standard NDE flaw sizes are intended to represent the detection capability of most qualified inspectors, and were primarily based on POD studies in the development of the Space Shuttle Program Orbiter fracture control plan. However, these Standard NDE flaw sizes were based on fatigue cracks in flat panels of one material alloy over a limited range of panel thicknesses. While the POD study was comprehensive, the inspection conditions are relatively narrow. An evaluation of similarity between the Standard NDE POD study and flight component conditions is required to apply Standard NDE to specific flight component inspections. A similarity evaluation may include differences in materials, surface finish, component geometry (e.g., curvature, corners, welds), and inspection access. Similarity is typically based on a qualitative engineering evaluation. Recently, NASA published a quantitative methodology to assess similarity. If similarity is not supported by test and analysis, then the methodology provides a transfer function of flaw size for Special NDE POD demonstration. NASA recommends that Special POD demonstrations use flaws that are flight-like or more difficult to detect than flight component flaws, which are commonly induced fatigue cracks. Often, it is not feasible to induce fatigue cracks in flight component geometry, and therefore, a simpler representative geometry is used, commonly a flat panel, for POD demonstration. Inducing cracks in simple geometry specimens can be time-consuming and expensive, and thus, minimizing the number of flawed specimens is desired. Traditionally, NASA Special NDE demonstration was limited to MIL-HDBK-1823A methods or the binomial point-estimate method (PEM), commonly known as 29/29. Recently, NASA published a limited-sample POD (LS-POD) methodology for signal-response NDE techniques (e.g., eddy current) that provides POD demonstration with fewer specimens than previous approaches. LS-POD suggests a minimum of 10 flawed specimens, compared to 29 in the PEM and the suggested minimum of 40 from MIL-HDBK-1823A. The methodology also includes new guidance on evaluating the probability of false calls. In this presentation, these new transfer function and LS-POD methodologies are described and illustrated through an eddy current detection capability of far-side flaws on thin welded panels. A geometry-based transfer function is developed using electro-discharge machined (EDM) notches in flight component and simple geometry to estimate the Special NDE flaw size that is representative of the critical initial flaw size required by the fracture analysis. Then, fatigue cracks are induced in simple flat panels of the transferred flaw size, and the LS-POD methodology is used for Special NDE demonstration.

P. A. Parker↗

Failure Investigation of WB-57 Aircraft Engine Cowling

The NASA Johnson Space Center (JSC) in Houston, Texas is the home of the NASA WB-57 High Altitude Research Program. Three fully operational WB-57 aircraft are based near JSC at Ellington Field. The aircraft have been flying research missions since the early 1960's, and continue to be an asset to the scientific community with professional, reliable, customer-oriented service designed to meet all scientific objectives. The NASA WB-57 Program provides unique, high-altitude airborne platforms to US Government agencies, academic institutions, and commercial customers in order to support scientific research and advanced technology development and testing at locations around the world. Mission examples include atmospheric and earth science, ground mapping, cosmic dust collection, rocket launch support, and test bed operations for future airborne or spaceborne systems. During the return from a 6 hour flight, at 30,000 feet, in the clean configuration, traveling at 175 knots indicated airspeed, in un-accelerated flight with the auto pilot engaged, in calm air, the 2-man crew heard a mechanical bang and felt a slight shudder followed by a few seconds of high frequency vibration. The crew did not notice any other abnormalities leading up to, or for the remaining 1 hour of flight and made an uneventful landing. Upon taxi into the chocks, the recovery ground crew noticed the high frequency long wire antenna had become disconnected from the vertical stabilizer and was trailing over the left inboard wing, and that the left engine upper center removable cowling panel was missing, with noticeable damage to the left engine inboard cowling fixed structure. The missing cowling panel was never recovered. Each engine cowling panel is attached to the engine nacelle using six bushings made of 17-4 PH steel. The cylinder portions of four of the six bushings were found still attached to the aircraft (Fig 1). The other two bushings were lost with the panel. The other four bushings exhibited ratchet marks (multiple fatigue origins) which initiated in the sharp radius of the flange/cylinder fillet and were observed 300 degrees around the flange perimeter (Fig 2-3). Low stress, high cycle fatigue (HCF) was observed on the fracture surfaces of all four bushings (Fig 4). To improve the cowling panel joint design and enable return to flight, new cowling bushings with thicker flanges and a larger machined flange/cylinder fillet radius were installed on all cowling panels. In addition, a spacer was added to the joint to achieve the proper stack tolerance. Finally, a time change requirement for all cowling bushings was instituted.

Martinez, J. E.↗

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

CLINICAL DECISION SUPPORT: PATH TO FUNCTIONAL REQUIREMENTS

Long-duration, deep-space exploration missions present significant challenges to crew health and performance. These challenges include the individual and combined effects of microgravity, radiation exposure, isolation, limited resources (mass, volume, power, data and crew time), limited options for evacuation and those associated with delayed or constrained communications, all of which demand greater crew autonomy. Specifically, as the communication delays intensify the further we explore space, the unqualified need for Earth-independent medical operations focused on autonomous diagnosis, treatment and prevention will be key to mission continuation and success. To augment the requisite knowledge, skills and abilities (KSAs) of a time-constrained crew operating under stressful conditions, combatting fatigue, and facing a potential medical crisis, a robust clinical decision support system (CDSS) is a probable solution that would facilitate, guide and inform Earth-independent medical operations, while assisting crewmembers through various clinical presentations. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) is expanding the boundaries of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit. ExMC is actively identifying and testing next-generation medical care and crew health maintenance technologies. The Clinical Decision Support (CDS) project addresses gap Medical-701 within the Inflight Medical Conditions risk: “Enhance medical capabilities within an exploration medical system.” Though mass, volume, and power will face increasing constraints, the projected computational capabilities of spacecraft systems will increase exponentially as information technology continues to advance this decade and beyond. Hence, data, software and computational resources will play an essential and synergistic role in maintaining crew health, wellness and performance in deep space missions. The focus of the CDS project is to develop recommended requirements for an in-vehicle CDSS that acts as a ‘virtual assistant’ for delivering optimal health, performance and medical care during exploration missions. The CDSS is envisioned as an integrated, software-based tool deployed on a laptop computer or handheld device. The CDSS will assist the crew and ground support when interacting with knowledge/databases (e.g. records, pharmacy, schedule), instrumentation (e.g. imaging, physiological monitoring devices), and habitat (e.g. wellness system, task performance system) and vehicle systems (e.g. environmental system, communication system). In addition, the human interface will employ a context-based approach that accounts for the crew’s situation. Thus, extraneous and clinically/operationally non-relevant information are reduced to avoid an increase in cognitive load. The framework of an ideal spaceflight CDSS is to include core and advanced analytical features that incorporate work from collaborators yet maintain a flexible platform for integrating new technology in the future. In fiscal year 2021 (FY21), the CDS project identified requirements through two primary mechanisms: (i) the development of software implementation prototypes and (ii) the application of systems engineering processes. The CDS project developed and tested a series of increasingly complex system prototypes that were based on use cases derived from the CDSS concept of operations (ConOps). These software implementations yielded insights on CDSS functionality as well as lessons learned that provided the initial requirements for CDSS capability. By applying a systems engineering (SE) approach, medical scenarios provided in the ConOps and the use cases for software implementation underwent functional decomposition to identify CDSS functionality. Also, systems-based modeling language (SysML) tools such as activity diagrams were developed from the same ConOps and use cases to identify CDSS functionality. The lessons learned from software implementation defined both specific requirements and broad areas of requirements. Within these defined broad requirement areas, further analysis of the SE products identified specific capability that resulted in the final functional requirements. In summary, the software prototypes, functional decomposition of the ConOps and use cases, and SysML diagrams provided the basis for the CDSS requirements developed in FY21. In the upcoming year, these requirements will be refined for their final ExMC baseline review in latter FY22.

clinical decision support↗