Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Image statistics decoding for convolutional codes

It is a fact that adjacent pixels in a Voyager image are very similar in grey level. This fact can be used in conjunction with the Maximum-Likelihood Convolutional Decoder (MCD) to decrease the error rate when decoding a picture from Voyager. Implementing this idea would require no changes in the Voyager spacecraft and could be used as a backup to the current system without too much expenditure, so the feasibility of it and the possible gains for Voyager were investigated. Simulations have shown that the gain could be as much as 2 dB at certain error rates, and experiments with real data inspired new ideas on ways to get the most information possible out of the received symbol stream.

Pitt, G. H., III↗

Standard Lexicons, Coding Systems and Ontologies for Interoperability and Semantic Computation in Imaging

Standard clinical terms, codes, and ontologies promote clarity and interoperability. Within radiology, there is a variety of relevant content resources, tools and technologies. These provide the basis for fundamental imaging workflows such as reporting and billing, and also facilitate a range of applications in quality improvement and research. This article reviews the key characteristics of lexicons, coding systems, and ontologies. A number of standards are described, including International Classification of Diseases-10-Clinical Modification (ICD-10-CM), Current Procedural Terminology (CPT), Systematized Nomenclature of Medicine—Clinical Terms (SNOMED CT), Logical Observation Identifiers Names and Codes (LOINC), and RadLex. Tools for accessing this material are reviewed, such as the National Center for Biomedical Ontology BioPortal system. Web services are discussed as a mechanism for semantic application development. Several example systems, workflows, and research applications using semantic technology are also surveyed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge coupled device integration-time coding for detection of images moving with unknown velocities

Existing techniques for the detection of a moving low light level image by a CCD array have required velocity synchronism between the image and the photogenerated charges. This was necessary to prevent blurring during the long duration of charge integration. A new detection scheme is described which causes the image to be convolved with a clock modulation signal as the photocharges are collected. The charge accumulating from each image point will now be spread over many photoelements due to the absence of velocity synchronism, but the output is not blurred in the usual sense. Instead the charge is distributed through the array in a controlled way so that the image can be reconstructed.

White, J. M.↗

Cost savings through multimission code reuse for Mars image products

An overview of the library's design will be presented, along with mission adaptation experiences and lessons learned, and the kinds of additional functionality that have been added while still retaining its multimission character. The application programs using the library will also be briefly described.

cost savings ground system image processing Mars i↗

Time-Encoded Gamma-Ray Imaging Using a 3-D Position-Sensitive CdZnTe Detector Array

The gamma-ray response of thick pixelated CdZnTe detectors varies spatially but is relatively constant as a function of time. Detector irregularities arise from flaws in the material, electrode fabrication, and gaps between the detectors in an array. These nonuniformities generate artifacts in coded aperture images that can obscure a source of interest. This article presents the theory, design, and demonstration of a 3-D CdZnTe-based time-encoded imager. Experimental results show the gamma-ray images of point-like and extended 57 Co and HEU-metal sources formed using a spatially nonuniform 3-D CdZnTe detector array and moving coded aperture mask. Image signal-to-noise ratio (SNR) for a point source was within 10% of its statistical limit at 250k counts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

Physics of Galaxy Clusters and How it Affects Cosmological Tests

The main activities in 2004 were focused on completion of the new 400 square degrees ROSAT PSPC survey for distant galaxy clusters. We observed and reduced optical spectra for all X-ray candidates and now we have complete identification for a statistically complete sample of distant 283 clusters. The papers describing the cluster catalog and first science results are in preparation and will be submitted in early 2005. We also completed a project to measure temperature and density profiles at large radii using Chandra observations of a 11 well exposed low-redshift clusters. We were able to demonstrate that the density, temperature, and total mass profiles are self-similar at large radii. This analysis has led to significant improvements in determination of the cluster baryon fraction as well as cosmologically important scaling relations, such as Mtot-T. The paper describing these results is submitted to ApJ in November, 2004. We continued to study evolution of the cluster scaling relations at high redshifts using Chandra and XMM data. We developed code for image and spectral deconvolution of the XMM observations. This code was used to reconstruct the distribution of baryons and total mass from observations of distant clusters which suffer from the finite size of the XMM PSF. This study allowed us to derive a high-redshift relation between cluster temperature and mass and compare it with the local relation obtained. The paper describing the first results is submitted to the ApJ. However, the project is still on-going as more distant cluster observations enter XMh4 and Chandra public data archives. We continued our work on improving techniques for accurate measurements of the cluster mass function and obtaining cosmological constraints from such observations. We published (ApJ, 601, 610) a study in which we derived the baryon mass function for a complete sample of low-redshift clusters. These papers argued that it was an excellent proxy for the total mass function. The baryon mass function can be used to constrain the amplitude and slope of the density fluctuation power spectrum on cluster scales. This method does not use observational determinations of the total mass and thus bypasses major uncertainties in the traditional analyses based on the X-ray temperature function. We derived the measurements for the amplitude of density perturbations, sigma8 = 0.72 +/- 0.04 and the shape parameter Omega*h = 0.l3 +/- 0.07, in good agreement with a number of independent methods.

Oliversen, Ronald J.↗

Exploiting fission chain reaction dynamics to image fissile materials

Radiation imaging is one potential method to verify nuclear weapons dismantlement. In this work, we present a method to discriminate between non-multiplying and multiplying neutron sources using a neutron coded aperture imaging system. This method applies time-correlated pulse-height (TCPH) analysis to identify neutrons in fission chain reactions and recreate images using only these events. This analysis was applied to measurements of weapons-grade plutonium (WGPu) metal and 252 Cf performed at the Nevada National Security Site (NNSS) Device Assembly Facility in July 2015. The results demonstrate it is possible to eliminate the non-fissile 252 Cf source from the image while preserving the fissile WGPu source. TCPH analysis was also applied to additional scenes in which the WGPu and 252 Cf sources were measured individually. The results of these separate measurements further demonstrate the ability to remove the non-fissile 252 Cf source and retain the fissile WGPu source. Simulations performed using MCNPX-PoliMi indicate that in a one hour measurement, hollow WGPu spheres are retained at a 1σ level for neutron multiplications M ≃ 2:7 and above. This work has potential application to dismantlement verification where it may be valuable to verify that all neutron sources in an image are multiplying.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WISE PHOTOMETRY FOR 400 MILLION SDSS SOURCES

We present photometry of images from the Wide-Field Infrared Survey Explorer (WISE) of over 400 million sources detected by the Sloan Digital Sky Survey (SDSS). We use a “forced photometry” technique, using measured SDSS source positions, star–galaxy classification, and galaxy profiles to define the sources whose fluxes are to be measured in the WISE images. We perform photometry with The Tractor image modeling code, working on our “unWISE” coaddds and taking account of the WISE point-spread function and a noise model. The result is a measurement of the flux of each SDSS source in each WISE band. Many sources have little flux in the WISE bands, so often the measurements we report are consistent with zero given our uncertainties. However, for many sources we get 3σ or 4σ measurements; these sources would not be reported by the “official” WISE pipeline and will not appear in the WISE catalog, yet they can be highly informative for some scientific questions. In addition, these small-signal measurements can be used in stacking analyses at the catalog level. The forced photometry approach has the advantage that we measure a consistent set of sources between SDSS and WISE, taking advantage of the resolution and depth of the SDSS images to interpret the WISE images; objects that are resolved in SDSS but blended together in WISE still have accurate measurements in our photometry. Our results, and the code used to produce them, are publicly available at http://unwise.me.

79 ASTRONOMY AND ASTROPHYSICS↗

Compressing subbanded image data with Lempel-Ziv-based coders

A method of improving the compression of image data using Lempel-Ziv-based coding is presented. Image data is first processed with a simple transform, such as the Walsh Hadamard Transform, to produce subbands. The subbanded data can be rounded to eight bits or it can be quantized for higher compression at the cost of some reduction in the quality of the reconstructed image. The data is then run-length coded to take advantage of the large runs of zeros produced by quantization. Compression results are presented and contrasted with a subband compression method using quantization followed by run-length coding and Huffman coding. The Lempel-Ziv-based coding in conjunction with run-length coding produces the best compression results at the same reconstruction quality (compared with the Huffman-based coding) on the image data used.

Glover, Daniel↗

HopBox: An image analysis pipeline to characterize hop cone morphology

Abstract Hop cone morphology can influence picking and drying ability, and color can impact consumer preference and may be indicative of quality. However, these characteristics are not generally evaluated in hop breeding programs due to the tedious nature of trait quantification and the extensive variation among cones within a genotype. We developed the HopBox, which is a simply constructed light box with a camera mount, and a publicly available image processing pipeline that identifies hop cones within color‐corrected images, reads a QR code within the image, and outputs data on hop cone length, width, area, perimeter, openness, weight, color, and density. The trained model was applied to images of 500 cones each from 15 replicated advanced hop genotypes from the USDA‐ARS breeding program in Prosser, Washington. Analysis of variance revealed significant ( p < 0.001) differences between genotypes for all traits measured, enabling breeders to discriminate between genotypes for selection purposes. Broad sense heritability for all traits ranged from 0.23 to 0.59. A random sampling of hop cones from the complete dataset revealed that imaging only 5–10 cones adequately captured genotypic variation and provided acceptable rank correlations ( r s > 0.75); however, increasing the sample size to 30 provided optimal precision. Instructions for constructing a HopBox and the code for the analysis pipeline are publicly available online and have wide applicability for hop breeding and research.

Altendorf, Kayla R.↗

Perceptually-Based Adaptive JPEG Coding

An extension to the JPEG standard (ISO/IEC DIS 10918-3) allows spatial adaptive coding of still images. As with baseline JPEG coding, one quantization matrix applies to an entire image channel, but in addition the user may specify a multiplier for each 8 x 8 block, which multiplies the quantization matrix, yielding the new matrix for the block. MPEG 1 and 2 use much the same scheme, except there the multiplier changes only on macroblock boundaries. We propose a method for perceptual optimization of the set of multipliers. We compute the perceptual error for each block based upon DCT quantization error adjusted according to contrast sensitivity, light adaptation, and contrast masking, and pick the set of multipliers which yield maximally flat perceptual error over the blocks of the image. We investigate the bitrate savings due to this adaptive coding scheme and the relative importance of the different sorts of masking on adaptive coding.

Watson, Andrew B.↗

Reduction of blocking effects for the JPEG baseline image compression standard

Transform coding has been chosen for still image compression in the Joint Photographic Experts Group (JPEG) standard. Although transform coding performs superior to many other image compression methods and has fast algorithms for implementation, it is limited by a blocking effect at low bit rates. The blocking effect is inherent in all nonoverlapping transforms. This paper presents a technique for reducing blocking while remaining compatible with the JPEG standard. Simulations show that the system results in subjective performance improvements, sacrificing only a marginal increase in bit rate.

Zweigle, Gregary C.↗