Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope Production Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Extraction of the non-spin- and spin-transfer isovector responses via the 12 C ⁡( 10 Be, 10 B + 𝛾)⁢ 12 B reaction

The isovector response in 12 B was investigated via the 12 C ⁡( 10 Be, 10 B + 𝛾)⁢ 12 B* reaction at 100⁢𝐴MeV. By utilizing the 𝛾-decay properties of the 1.74 MeV 0 + and 0.718 MeV 1 + states in 10 B, the separate extraction of the non-spin-transfer (Δ⁢𝑆 = 0) and spin-transfer (Δ⁢𝑆 = 1) isovector responses up to an excitation energy of 50 MeV in 12 B in a single measurement is demonstrated. The experimental setup employed the S800 spectrometer to detect and analyze the 10 B ejectiles and the Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) for obtaining the Doppler-reconstructed spectrum for 𝛾 rays emitted in flight by 10 B. A 12 C foil was placed at the pivot point of the spectrograph. Here, the 12 B reaction product was not detected. Contributions from transitions associated with the transfer of different units of angular momentum in the non-spin- and spin-transfer responses were analyzed using a multipole decomposition analysis. The extracted non-spin-dipole (Δ⁢𝑆 = 0, Δ⁢𝐿 = 1) and spin-dipole (Δ⁢𝑆 = 1, Δ⁢𝐿 = 1) responses were found to be consistent with available data from other charge-exchange probes, validating the non-spin- and spin-transfer filters used. While statistical uncertainties and experimental resolutions were relatively large due to the modest intensity of the 10 Be secondary beam, the results show that, with the much higher intensities that will be available at new rare-isotope beam facilities, the ( 10 Be, 10 B + 𝛾) reaction and its Δ⁢𝑇 𝑧 = −1 partner, the ( 10 C, 10 B + 𝛾) reaction, are powerful tools for elucidating the isovector non-spin- and spin-transfer responses in nuclei.

Charge-exchange reactions↗

First inverse kinematics measurement of resonances in Be 7 ( α , γ ) C 11 relevant to neutrino-driven wind nucleosynthesis using DRAGON

A possible mechanism to explain the origin of the light $\textit{p}$ nuclei in the Galaxy is the nucleosynthesis in the proton-rich neutrino-driven wind ejecta of core-collapse supernovas via the $\textit{νp}$ process. However, this production scenario is very sensitive to the underlying supernova dynamics and the nuclear physics input. As far as the nuclear uncertainties are concerned, the breakout from the $\textit{pp}$ chains via the 7 Be(α,γ) 11 C reaction has been identified as an important link which can influence the nuclear flow and, therefore, the efficiency of the $\textit{νp}$ process. However, its reaction rate is poorly known over the relevant temperature range, $\textit{T}$ = 1.5–3 GK. We report on the first direct measurement of two resonances of the 7 Be(α,γ) 11 C reaction with previously unknown strengths using an intense radioactive 7 Be beam from the Isotope Separator and Accelerator (ISAC-I) Center facility and the DRAGON recoil separator in inverse kinematics. In this work, we have decreased the 7 Be(α,γ) 11 C reaction rate uncertainty to ≈9.4–10.7% over the relevant temperature region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Post-Irradiation Examination on MiniFuel UCO and UO 2 TRISO Particles Irradiated in HFIR at High Power

Post-irradiation examination (PIE) of MiniFuel compacts was conducted at Oak Ridge National Laboratory (ORNL) under the Nuclear Science User Facilities project in collaboration with Kairos Power (KP) to evaluate the performance of tristructural-isotropic (TRISO) particles under high particle power and fluoride-salt-cooled high-temperature reactor (FHR)-relevant conditions. MiniFuel compacts containing low-enriched uranium oxide-uranium carbide (LEUCO), low-enriched uranium dioxide (LEUO2), and natural UCO (NUCO) kernels were irradiated for four cycles at ORNL’s High Flux Isotope Reactor (HFIR) at target temperatures between 500°C and 900°C. Post irradiation, the experiment was disassembled at ORNL to recover the MiniFuel subcapsules, which were subsequently punctured to measure fission gas release. Subcapsule disassembly allowed the recovery of components of interest, such as silicon carbide (SiC) thermometry, fuel specimens, fission product sinks, and SiC spacers. The experimental irradiation temperature was confirmed by analyzing the SiC thermometry via dilatometry. PIE on the fuel specimens included gamma spectrometry and deconsolidation leach burn leach, which were complemented by imaging techniques such as x-ray computed tomography, optical microscopy, and electron microscopy. The PIE results provide insight into TRISO particle integrity, fission product retention, coating performance, and kernel migration, informing fuel qualification for application in KP’s FHR concept.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mark-18A Target Material Recovery Program: Initial Hot Startup

The Savannah River National Laboratory (SRNL) has been tasked by the National Nuclear Security Administration to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The Mk-18A targets were manufactured with Pu-242 then irradiated under high neutron flux in K-Reactor at the SRS from 1968 to 1978. The sixty-five Mk-18A targets are currently stored in the SRS L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The original targets were manufactured with varying quantities of Pu-242, ranging from 5.2 grams to 121.5 grams. Taking a graded approach to process start up, the lowest loaded target (FT-80-03) was selected as the first target to be received and processed at SRNL. As operational experience and knowledge is gained from processing targets, higher loaded targets will be selected for processing to increase the quantities of valuable isotopes recovered. Due to dose concerns, the receipt and processing of the Mk-18A targets is performed in the SRNL Shielded Cells Facility. The targets are stored in a double J-can confinement in the L-Area Basin. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets are loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 length) are then processed one at a time through the following processes: caustic dissolution and filtration, acidic dissolution and filtration, elutable Reillex anion exchange, diglycolamide (DGA) resin extraction, and DGA calcination. This processing results in two product streams. The first is an aqueous plutonium solution which is removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide product containing the Am and Cm as well as other lanthanide fission products which is removed from the shielded cells using a bagless transfer system. Both materials are packaged for shipment to Oak Ridge National Laboratory (ORNL). This paper will discuss the operating experience, lessons learned, and results from initial process hot startup.

Armstrong, Christopher [Savannah River National La↗

Measurements of Short-Lived Isomers from Photofission as a Method of Active Interrogation for Special Nuclear Materials

Isomeric fission products, such as 134m Te (T 1/2 = 164 ns) and 136m Xe (T 1/2 = 2.95 μs), are proposed as a signature of special nuclear materials in active interrogation applications. To test this conjecture, monoenergetic 9, 11, and 13 MeV photons from the HIγS facility are used to induce fission of 235 U, 238 U, and 239 Pu targets. The de-excitation γ rays of the isomers are measured using time-gated spectroscopy with high-purity germanium detectors. The 134m Te and 136m Xe isomers are detected and identified by the energy and decay half-life of their characteristic γ-ray transitions. The ratio of yields for these two signature γ rays, corresponding to 134m Te/( 136m Xe + 136 I), is found to be strongly correlated with the identity of the fissioning nuclei. These results show that fission-product isomers may be used in active interrogation to detect and identify special nuclear materials, even providing information on the isotopic enrichment. In conclusion, the feasibility of an active interrogation scenario using a bremsstrahlung beam is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Post-Irradiation Examination on MiniFuel UCO and UO 2 TRISO Particles Irradiated in HFIR at High Power

Post-irradiation examination (PIE) of MiniFuel compacts was conducted at Oak Ridge National Laboratory (ORNL) under the Nuclear Science User Facilities project in collaboration with Kairos Power (KP) to evaluate the performance of tristructural-isotropic (TRISO) particles under high particle power and fluoride-salt-cooled high-temperature reactor (FHR)-relevant conditions. MiniFuel compacts containing low-enriched uranium oxide-uranium carbide (LEUCO), low-enriched uranium dioxide (LEUO 2 ), and natural UCO (NUCO) kernels were irradiated for four cycles at ORNL’s High Flux Isotope Reactor (HFIR) at target temperatures between 500°C and 900°C. Post irradiation, the experiment was disassembled at ORNL to recover the MiniFuel subcapsules, which were subsequently punctured to measure fission gas release. Subcapsule disassembly allowed the recovery of components of interest, such as silicon carbide (SiC) thermometry, fuel specimens, fission product sinks, and SiC spacers. The experimental irradiation temperature was confirmed by analyzing the SiC thermometry via dilatometry. PIE on the fuel specimens included gamma spectrometry and deconsolidation leach burn leach, which were complemented by imaging techniques such as x-ray computed tomography, optical microscopy, and electron microscopy. The PIE results provide insight into TRISO particle integrity, fission product retention, coating performance, and kernel migration, informing fuel qualification for application in KP’s FHR concept.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Understanding the Structure and Dynamics of Complex Biomembrane Interactions by Neutron Scattering Techniques

The membrane is one of the key structural materials of biology at the cellular level. Composed predominantly of a bilayer of lipids with embedded and bound proteins, it defines the boundaries of the cell and many organelles essential to life and therefore is involved in almost all biological processes. Membrane-specific interactions, such as drug binding to a membrane receptor or the interactions of an antimicrobial compound with the lipid matrix of a pathogen membrane, are of interest across the scientific disciplines. Herein we present a review, aimed at nonexperts, of the major neutron scattering techniques used in membrane studies: small-angle neutron scattering, neutron membrane diffraction, neutron reflectometry, quasielastic neutron scattering, and neutron spin echo. Neutron scattering techniques are well suited to studying biological membranes. The nondestructive nature of cold neutrons means that samples can be measured for long periods without fear of beam damage from ultraviolet, electron, or X-ray radiation, and neutron beams are highly penetrating, thus offering flexibility in samples and sample environments. Most important is the strong difference in neutron scattering lengths between the two most abundant forms of hydrogen, protium and deuterium. Changing the relative amounts of protium/deuterium in a sample allows the production of a series of neutron scattering data sets, enabling the observation of differing components within complex membrane architectures. This approach can be as simple as using the naturally occurring neutron contrast between different biomolecules to study components in a complex by changing the solution H 2 O/D 2 O ratio or as complex as selectively labeling individual components with hydrogen isotopes. This review presents an overview of each experimental technique with the neutron instrument configuration, related sample preparation and sample environment, and data analysis, highlighted by a special emphasis on using prominent neutron contrast to understand structure and dynamics. This review gives researchers a practical introduction to the often enigmatic suite of neutron beamlines, thereby lowering the barrier to taking advantage of these large-facility techniques to achieve new understandings of membranes and their interactions with other molecules.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient loading of reduced data ensembles produced at ORNL SNS/HFIR neutron time-of-flight facilities

We present algorithmic improvements to the loading operations of certain reduced data ensembles produced from neutron scattering experiments at Oak Ridge National Laboratory (ORNL) facilities. Ensembles from multiple measurements are required to cover a wide range of the phase space of a sample material of interest. They are stored using the standard NeXus schema on individual HDF5 files. This makes it a scalability challenge, as the number of experiments stored increases in a single ensemble file. The present work follows up on our previous efforts on data management algorithms, to address identified input output (I/O) bottlenecks in Mantid, an open-source data analysis framework used across several neutron science facilities around the world. We reuse an in-memory binary-tree metadata index that resembles data access patterns, to provide a scalable search and extraction mechanism. In addition, several memory operations are refactored and optimized for the current common use cases, ranging most frequently from 10 to 180, and up to 360 separate measurement configurations. Results from this work show consistent speed ups in wall-clock time on the Mantid LoadMD routine, ranging from 19% to 23% on average, on ORNL production computing systems. The latter depends on the complexity of the targeted instrument-specific data and the system I/O and compute variability for the shared computational resources available to users of ORNL’s Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) instruments. Nevertheless, we continue to highlight the need for more research to address reduction challenges as experimental data volumes, user time and processing costs increase.

Godoy, William↗

In-gas-jet laser spectroscopy with S 3 -LEB

The Super Separator Spectrometer-Low Energy Branch (S 3 -LEB) is a low-energy radioactive ion beam experiment under commissioning as part of the GANIL-SPIRAL2 facility. It will be used for the production and study of exotic nuclei by in-gas laser ionization and spectroscopy (IGLIS), decay spectroscopy, and mass spectrometry. Here, we report recent results from the off-line commissioning of S 3 -LEB, including first laser spectroscopy measurements in both the gas cell and the supersonic gas jet, the determination of the transport efficiency of laser ions from the gas cell through the RFQ chain, and time-of-flight measurements with the multi-reflection time-of-flight mass spectrometer PILGRIM. The measurements were performed using erbium, introduced by evaporation from a heated filament in the gas environment. The reported laser spectroscopy results include a characterization of the pressure broadening in the gas cell, proof-of-principle isotope shift measurements, and hyperfine-structure measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mark-18A Cold Runs

The Savannah River National Laboratory (SRNL) is tasked by the National Nuclear Security Administration (NNSA) to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The sixty-five Mk-18A targets are currently stored in the L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The remaining unrecovered material will be discarded to the high activity drain (HAD) system in SRNL. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets will be loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 lengths) will then be processed one at a time through the following processes: caustic dissolution and filtration; acidic dissolution and filtration, Reillex anion exchange, diglycolamide (DGA) cation exchange; and DGA calcination. This processing will result in two product streams. The first is an aqueous plutonium solution which will be removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide containing the Am and Cm as well as other lanthanide fission products which will be removed from the shielded cells using a bagless transfer system. Both materials will be packaged for shipment to Oak Ridge National Laboratory (ORNL). All equipment to carry out this process was designed, procured or fabricated, and installed in a mock-up facility (716-4A) at SRS to allow for simulation testing in a non-radioactive area. This equipment was then dismantled and transferred from 716-4A to 773-A and installed in the SRNL Shielded Cells. After installation in the shielded cells facility testing was performed using water followed by surrogates and cold chemicals. Issues were identified during these evaluations, including equipment issues as well as technical challenges. Many of the issues were rectified during performance of the cold runs, and the remaining have a resolution identified. Table ES-1 provides a summary of all issues identified during the cold run operations, as well as the status and identified resolutions to outstanding issues.

07 ISOTOPE AND RADIATION SOURCES↗

Indirect measurement of the 90 Sr ⁢(𝑛, 𝛾)⁢ 91 Sr reaction cross section and the implications for astrophysical Zr production

Here, the intermediate neutron-capture process (𝑖 process) has gained notable traction within the past decade as a way to describe stellar abundance observations which cannot be explained by the slow and rapid neutron-capture processes. Despite the general success of 𝑖-process models, many open questions remain. Among the observations, Zr stands out, as its elemental abundance is difficult to replicate with available 𝑖-process models, while the reactions that affect its production through the 𝑖 process are close enough to stability to study experimentally. Here, we present the experimental constraint of the nuclear level density and 𝛾-strength function (𝛾 SF) of 91 Sr using the 𝛽-Oslo method, which were then input into the TALYS Hauser-Feshbach code to produce the first experimental constraint of the 90 Sr ⁢(𝑛, 𝛾)⁢ 91 Sr capture reaction. This constraint was used alongside that of 92 Sr ⁢(𝑛, 𝛾)⁢ 93 Sr for a reduction in the uncertainty of [Y/Zr] production in the 𝑖-process relevant environmental neutron density of 10 13.5 and 10 14.5 neutrons/cm 3 .

Physics - Nuclear physics and radiation physics↗

IAEA Photonuclear Data Library 2019

Here, photo-induced reaction cross section data are of importance for a variety of current or emerging applications, such as radiation shielding design and radiation transport analyses, calculations of absorbed dose in the human body during radiotherapy, physics and technology of fission reactors (influence of photo-reactions on neutron balance) and fusion reactors (plasma diagnostics and shielding), activation analyses, safeguards and inspection technologies, nuclear waste transmutation, medical isotope production and astrophysical applications. To address these data needs the IAEA Photonuclear Data library was produced in 1999, containing evaluated photo-induced cross sections and neutron spectra for 164 nuclides which were deemed relevant for the applications. Since the release of the IAEA Photonuclear Data Library however, new experimental data as well as new methods to assess the reliability of experimental cross sections have become available. Theoretical models and input parameters used to evaluate photo-induced reactions have improved significantly over the years. In addition, new measurements of partial photoneutron cross sections using mono-energetic photon beams and advanced neutron detection systems have been performed allowing for the validation of the evaluations and assessments of the experimental data. Furthermore, technological advances have led to the construction of new and more powerful gamma-beam facilities, therefore new data needs are emerging. We report our coordinated efforts to address these data needs and present the results of the new up-to-date evaluations included in the new updated IAEA Photonuclear Data Library consisting of 219 nuclides. The new library includes 188 new evaluations produced by the CRP evaluators, and one evaluation taken from the JENDL/PD-2016 library, while 20 evaluations were retained from the previous 1999 IAEA Photonuclear Data Library. In most of the cases, the photon energy goes up to 200 MeV. A total of 55 nuclides are new in this library reflecting the progress in measurements but also the developing data needs. In this paper we discuss the new assessment method and make recommendations to the user community in cases where the experimental data are discrepant and the assessments disagree. In addition, in the absence of experimental data, we present model predictions for photo-induced reaction cross section on nuclides of potential interest to medical radioisotope production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological Monitoring Plan for the Oak Ridge Y-12 National Security Complex: Surface Water

DOE Order 458.1 requires that dose estimates consider contributions from all facilities. In the Y-12 Radiological Monitoring Plan (RMP), surface water is monitored at points that reflect individual facilities, as well as at points that reflect the combined contributions of all facilities. This monitoring plan does not consider other potential routes (i.e., airborne releases and food chains). Thus, a complete determination of total effective dose (TED) cannot be made based on this plan alone. The other routes from Y-12, and all routes from other DOE facilities on the Oak Ridge Reservation (e.g., Oak Ridge National Laboratory (ORNL) and The Heritage Center), must be considered in order to satisfy DOE Order 458.1 requirements. Determination of TED from all sites and pathways is done through the use of dose-assessment models and is documented in the Annual Site Environmental Report. This monitoring plan provides adequate monitoring goals for Y-12 surface water releases to provide input of sufficient sensitivity and accuracy to reliably determine the Y-12 surface water component of the TED. The routine radiological monitoring program is designed to monitor effluents at four types of locations: (1) treatment facilities, (2) other point and area source discharges, (3) instream locations, and (4) production building roof run-off. With this sampling and analysis program, data will be obtained on primary point sources as well as on locations that represent the composite of other potential sources. This plan will be reviewed periodically to determine necessary modifications to the sampling frequencies, parameters, and locations. Modifications, if any, will be based on the analysis of the previous data and its effectiveness in satisfying the objectives of this plan. Appendix A contains graphs of the sum of the DCS fractions for locations and frequencies contained in a previous version of this plan. The data was collected from January 2009 through December 2019. Each sample was analyzed, and each result was divided by the appropriate DCS to compute a DCS fraction. These fractions were summed for all isotopes. According to DOE –STD-1196-2011, the annual average of these sums should be below 1.

54 ENVIRONMENTAL SCIENCES↗

Recovery and Recycle of Irradiated Low-Enriched Uranium from the Production of 99 Mo

Technetium-99m ( 99m Tc), the daughter (decay product) of molybdenum-99 ( 99 Mo), is the most commonly used medical radioisotope in the world. 99 Mo is produced primarily from the fissioning of 235 U. A potential future producer, Eden Radioisotopes, is planning to irradiate low-enriched-uranium metal-foil targets for production of 99 Mo. Their plan is to recover, purify, and recycle the irradiated LEU in a new set of targets inside their facility. This study assesses processes to (1) purify and recycle uranium following 99 Mo recovery and (2) convert the uranium to metal for subsequent foil production and target fabrication. A UREX (uranium recovery by extraction) liquid–liquid extraction flowsheet that utilizes centrifugal contactors was developed using the Argonne model for universal solvent extraction (AMUSE) to recover and purify the uranium. The calculated flowsheet predicted high decontamination from Pu and most fission products and >99.99% recovery of uranium. Suggestions for conversion of the UREX U-product (uranyl nitrate in dilute nitric acid) to U metal were provided based on literature studies and earlier laboratory studies performed at Argonne National Laboratory.

07 ISOTOPE AND RADIATION SOURCES↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analyzing existing and planned nuclear facilities as potential sources for unusual xenon radionuclides (127Xe, 129mXe, 125Xe, 122Xe)

Unusual xenon radionuclides (127Xe, 129mXe, 125Xe, 122Xe) were observed during temporary operation of a radioxenon monitoring station in the vicinity of a high flux nuclear reactor and a spallation neutron source. Meteorological modeling showed that these two facilities were the most likely source of these emissions. Because 127Xe by itself, and this mix of radionuclides together can lead to false-positive reports for the four xenon radionuclides of interest (135Xe, 133Xe, 133mXe, and 131mXe), it is important for radioxenon monitoring station operators to be aware of potential sources of these interfering radionuclides. This work will look at the location and source intensities of both high flux nuclear reactors, and spallation neutron sources around the world, to see if the potential exists in other regions for production and observance of the unusual xenon radionuclides (127Xe, 129mXe, 125Xe, 122Xe).

07 ISOTOPE AND RADIATION SOURCES↗