Solid state image sensor research Final technical report
Fifty-element linear arrays of InAs photodiodes
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fifty-element linear arrays of InAs photodiodes
The isotopic composition of Pb and the elemental concentration of U, Th and Pb were measured on 'total' rock samples 14053, 14073 and 14310 and on mineral separates of 14310 and 14053. These are the first Pb-U isochrons obtained for lunar basalts and indicate a reasonable solution to the previous discrepancy between the different methods of 'absolute' age determination. The resulting U-Pb isochron ages are compatible with the Rb-Sr and K-Ar ages on the same rocks. However, it is not possible to establish a precise time of 'crystallization' from the Pb-U data because of the small angle of intersection between the linear arrays and the concordia curve. These data show that total rock model ages do not in general yield crystallization ages. The data on 14310 and 14053 show that these rocks were formed containing a highly radiogenic initial lead which accounts for the excessively high total rock model ages by the U-Th-Pb method. The data prove that at the time of extrusion of some basalts, unsupported lead with extremely high Pb-207/Pb-206 ratios was added to the lunar surface.
Recent improvements in the pyroelectric detector have been due to the development of locked-in polarization, further reduction of the FET leakage current, and reduction of short circuit noise. The pyroelectric detector has been successfully employed in these typical applications: (1) thermograph using a single detector and X-Y scanner, (2) focal plane reticle scanner, (3) linear array thermal imaging system, (4) pyroelectric image tube, (5) radiometers (vertical temperature profile radiometer, carbon dioxide sensor), (6) high speed spectrometer, and (7) laser detector.
A transcutaneous system for real-time imaging of arteries is described. A transducer probe containing three linear arrays of elements scans tissues within the element Fresnel zones. Each element is multiplexed in turn to a pulsed Doppler processor to permit real-time visualizations of moving targets. Applications of the motion-indicating B-scans are discussed, with special attention to problems in transcutaneous measurement of blood flow.
This invention integrates a spectrometer capability with the basic imagery function of facsimile cameras without significantly increasing mechanical or optical complexity, or interfering with the imaging function. The invention consists of a group of photodetectors arranged in a linear array in the focal plane of the facsimile camera with a separate narrow band interference filter centered over each photodetector. The interference filter photodetector array is on a line in the focal plane of the facsimile camera along the direction of image motion due to the rotation of the facsimile camera's vertical mirror. As the image of the picture element of interest travels down the interference filter photodetector array, the photodetector outputs are synchronously selected and sampled to provide spectral information on the single picture element.
We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.
An instrument with a single ultrasonic transducer probe and a linear array of transducer probes permitting three operator modes is described. An 'A' and an 'M' mode scanner were combined with a 'C' mode scanner and a single receiver is used. The 'C' scanner mode enables two-dimensional cross sections of the viewed organ. Video-produced markers enable measurement of the dimensions of the heart. COS/MOS integrated logic circuit components are used to minimize power consumption and permit battery operation.
A synthesis method is presented for determining an excitation of an arbitrary (but fixed) planar source configuration. The desired radiation pattern is specified over all or part of the visible region. It may have multiple and/or shaped main beams with low sidelobes. The iterative sampling method is used to find an excitation of the source which yields a radiation pattern that approximates the desired pattern to within a specified tolerance. In this paper the method is used to calculate excitations for line sources, linear arrays (equally and unequally spaced), rectangular apertures, rectangular arrays (arbitrary spacing grid), and circular apertures. Examples using these sources to form patterns with shaped main beams, multiple main beams, shaped sidelobe levels, and combinations thereof are given.
Development of the Solar Power Satellite (SPS) system for initial operation in the late 1990's requires substantial orbital development activities in the mid-1980's leading to a key system development decision in about 1987. A manned Space Construction Base (SCB) in low-earth orbit is needed to support the SPS orbital development program. The SPS system development issues are defined, along with a candidate development program for resolving these issues. The development hardware systems of interest for the mid-1980's include: (1) a tapered linear array microwave antenna (123 x 125.6 m 'cross') with a 57-kW/rf amplitron output, which is SCB constructed and operated in low-earth orbit initially, and, subsequently, unmanned in geosynchronous earth orbit; and (2) a SCB-constructed and -operated 9 x 14.4 m planar array antenna (358 kW/rf/) powered by a 455-kWe silicon photovoltaic solar collector.
The status of aircraft multispectral scanner technology was accessed in order to develop preliminary design specifications for an advanced instrument to be used for remote sensing data collection by aircraft in the 1980 time frame. The system designed provides a no-moving parts multispectral scanning capability through the exploitation of linear array charge coupled device technology and advanced electronic signal processing techniques. Major advantages include: 10:1 V/H rate capability; 120 deg FOV at V/H = 0.25 rad/sec; 1 to 2 rad resolution; high sensitivity; large dynamic range capability; geometric fidelity; roll compensation; modularity; long life; and 24 channel data acquisition capability. The field flattening techniques of the optical design allow wide field view to be achieved at fast f/nos for both the long and short wavelength regions. The digital signal averaging technique permits maximization of signal to noise performance over the entire V/H rate range.
The use of silicon photodiode sensors and locator systems for lightning experiments is discussed. Tables are presented on: (1) satellite optical lightning experiments (silicon detectors); (2) reticon photodiode linear arrays; and (3) locator systems (grey code and reticon). An illustration of a grey code locator system for a low altitude satellite is also given.
The potential of space systems and technology for detecting and monitoring ocean oil spills and waste pollution was assessed as well as the impact of this application on communication and data handling systems. Agencies charged with responsibilities in this area were identified and their measurement requirements were ascertained in order to determine the spatial resolution needed to characterize operational and accidental discharges. Microwave and optical sensors and sensing techniques were evaluated as candidate system elements. Capabilities are described for the following: synthetic aperture radar, microwave scatterometer, passive microwave radiometer, microwave altimeter, electro-optical sensors currently used in airborne detection, existing space-based optical sensors, the thematic mapper, and the pointable optical linear array.
Along with a colorimetric data analysis scheme, the instrumental parameters which need to be optimized in future spaceborne ocean color scanner systems are outlined. With regard to assessing atmospheric effects from ocean colorimetry, attention is given to computing size parameters of the aerosols in the atmosphere, total optical depth measurement, and the aerosol optical thickness. It is suggested that sensors based on the use of linear array technology will meet hardware objectives.
A three band Linear Array Pushbroom Radiometer (LAPR) was built and flown on an experimental basis by NASA at the Goddard Space Flight Center. The functional characteristics of the instrument and the methods used to preprocess the data, including radiometric correction, are described. The radiometric sensitivity of the instrument was tested and compared to that of the Thematic Mapper and the Multispectral Scanner. The radiometric correction procedure was evaluated quantitatively, using laboratory testing, and qualitatively, via visual examination of the LAPR test flight imagery. Although effective radiometric correction could not yet be demonstrated via laboratory testing, radiometric distortion did not preclude the visual interpretation or parallel piped classification of the test imagery.
A description is given of current work in the development of sensors, and their integration into increasingly powerful systems, for oceanic phytoplankton abundance estimation. Among the problems relevant to such work are phytoplankton ecology, the spatial and temporal domains, available sensor platforms, and sensor combinations. Among the platforms considered are satellites, aircraft, tethered balloons, helicopters, ships, and the Space Shuttle. Sensors discussed include microwave radiometers, laser fluorosensors, microwave scatterometers, multispectral scanners, Coastal Ocean Dynamics Radar (CODAR), and linear array detectors. Consideration is also given to the prospects for such future sensor systems as the National Oceanic Satellite System (NOSS) and the Airborne Integrated Mapping System (AIMS).
A three-band Linear Array Pushbroom Radiometer (LAPR) was built and flown on an experimental basis by NASA, at the Goddard Space Flight Center. The functional characteristics of the instrument and the methods used to preprocess the data, including radiometric correction, are described. The radiometric sensitivity of the instrument was tested and compared to that of the Thematic Mapper and the Multispectral Scanner. The radiometric correction procedure was evaluated quantitatively, using laboratory testing, and qualitatively, by visual examination of the LAPR test flight imagery. Although effective radiometric correction could not yet be demonstrated by laboratory testing, radiometric distortion did not preclude the visual interpretation or classification of the test imagery.
A package of computer programs was developed for analyzing acoustic data from an aircraft flyover. The package assumes the aircraft is flying at constant altitude and constant velocity in a fixed attitude over a linear array of ground microphones. Aircraft position is provided by radar and an option exists for including the effects of the aircraft's rigid-body attitude relative to the flight path. Time synchronization between radar and acoustic recording stations permits ensemble averaging techniques to be applied to the acoustic data thereby increasing the statistical accuracy of the acoustic results. Measured layered meteorological data obtained during the flyovers are used to compute propagation effects through the atmosphere. Final results are narrow-band spectra and directivities corrected for the flight environment to an equivalent static condition at a specified radius.
Factors effecting the sharpness of images acquired by multispectral scanners, synthetic aperture radar, thermal infrared sensors, and multispectral linear arrays are defined. Factors associated with the sensor include the atmospheric blur/scatter function, the point spread function of the sensor, the sensor aperture, the filter characteristics, and the sampling rate and quatization effects. Several research tasks are proposed which include investigating the use of optical prefilters which include investigating the use of optical prefilters and the relationships of the instantaneous field of view (aperture width) on the performance of geocorrelation systems.