Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Development of a Laser Ultrasonics-based Approach for Rapid Screening of High Entropy Alloys

This project utilized a laser ultrasonic technique to systematically study temperature-induced evolution of material properties in a set of interrelated binary alloys and a high entropy alloy (HEA) fabricated using arc-melting and spark plasma sintering processes. This technique involved the use of a nanosecond duration, high-intensity pulsed laser to thermo-elastically generate ultrasonic waves that propagate in the bulk of the metal alloy. Sub-nanometer-scale displacements associated with the propagating bulk ultrasonic waves were detected along the epicenter on the opposite surface of the sample using a 1 GHz bandwidth photorefractive interferometer. Phase transformations and microstructural changes were inferred from the temperature-dependent trends in the bulk acoustic velocities and features in the ultrasonic epicentral waveforms measured in the binary alloys. These inferences were then correlated with electron/optical microscopy observations and predictions using calculations of phase diagrams (CALPHAD). The results showed that the laser-generated ultrasonic pulses were strongly influenced by changes in material microstructure and could accurately track thermally driven phase transformations and detect the presence of microscale heterogeneities (grain boundaries, dendritic structures, etc.) in the set of binary alloy samples. The measurement approach was then applied to a quinary HEA sample for estimating phase transition temperature and determining microstructural heterogeneity. The rapid, non-contact and non-destructive ultrasonic testing approach demonstrated here is amenable to high throughput combinatorial investigations that can be applied to graded composition HEAs produced using advanced manufacturing methods. When paired with atomistic simulations and CALPHAD modeling, this approach can overcome the bottlenecks faced by current material characterization methods in efficiently screening the vast discovery space of HEAs that spans over a hundred million unique quinary alloy compositions.

36 MATERIALS SCIENCE↗

JPL self pulsed laser surface measurement system development

The use of a self pulsed laser system for accurately describing the surface shape of large space deployed antenna structures was evaluated. Tests with a breadboard system verified functional operation with short time resolution on the order of .2 mm, nonambiguous ranging, and a maximum range capability on the order of 150 m. The projected capability of the system is resolution of less than .1 mm over a reasonable time period and a range extension to over 300 m.

Berdahl, M.↗

Reliability improvements in tunable Pb1-xSnxSe diode lasers

Recent developments in the technology of Pb-salt diode lasers which have led to significant improvements in reliability and lifetime, and to improved operation at very long wavelengths are described. A combination of packaging and contacting-metallurgy improvements has led to diode lasers that are stable both in terms of temperature cycling and shelf-storage time. Lasers cycled over 500 times between 77 K and 300 K have exhibited no measurable changes in either electrical contact resistance or threshold current. Utilizing metallurgical contacting process, both lasers and experimental n-type and p-type bulk materials are shown to have electrical contact resistance values that are stable for shelf storage periods well in excess of one year. Problems and experiments which have led to devices with improved performance stability are discussed. Stable device configurations achieved for material compositions yielding lasers which operate continuously at wavelengths as long as 30.3 micrometers are described.

Linden, K. J.↗

Optomechanical design considerations in the development of the DDLT laser diode collimator

A laser diode collimator objective was developed in support of the Direct Detection Transceiver program. Close attention to optomechanical design issues including athermalization, alignment, selection of materials, mounting of elements, and hermetic sealing of the assembly was necessary to insure that the desired optical performance was maintained in space deployment.

Kampe, Thomas U.↗

Laser altimeter

The development of a laser altimeter for use in the Apollo Lunar Orbital Experiments mission is discussed. The altimeter provides precise measurement of an Apollo vehicle above the lunar surface from an orbit of 40 to 80 nautical miles. The technical characteristics of the altimeter are described. Management of the altimeter development program is analyzed.

Source record↗

Independent Reliability Assessment and Progress Review of the NASA GSFC Laser Transmitter for the LISA Program

NASA Goddard Space Flight Center (GSFC) has been actively developing the laser transmitter for the Laser Interferometer Space Antenna (LISA) program since the late 2017. In 2021 we delivered a prototype laser transmitter to the LISA program for performance evaluation as well as performed an independent technology assessment on the laser design supported by the NASA Engineering and Safety Center (NESC). We continued to further develop the LISA laser with a goal of advancing the technology readiness level (TRL) of the laser to 6 by the end of 2023. In this paper, we report on the progress we made on the laser development for the LISA program as well as the technology assessment findings by the NESC.

Independent Reliability Assessment↗

Development and utilization of a laser velocimeter system for a large transonic wind tunnel

The need for measurements of the velocity flow field about spinner propeller nacelle configurations at Mach numbers to 0.8 was met by a specially developed laser velocimeter system. This system, which uses an argon ion laser and 4 beam 2 color optics, was required to operate in the hostile environment associated with the operation of a large transonic wind tunnel. To overcome the conditions present in locating the sensitive optics in close proximity to the wind tunnel, an isolation system was developed. The system protects the velocimeter from the high vibrations, elevated temperatures, destructive acoustic pressures and low atmospheric pressures attendant with the operation of the wind tunnel. The system was utilized to map the flow field in front of, behind and in between the rotating blades of an advanced swept blade propeller model at a Mach number of 0.8. The data collected by the system will be used to correlate and verify computer analyses of propeller nacelle flow fields and propeller performance.

Freedman, R. J.↗

Development of a versatile laser light scattering instrument

A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.

Meyer, William V.↗

Laser driven inertial fusion energy technology development

The future of Laser-Based Inertial fusion energy requires the development of efficient diode-pumped laser drivers that can be scaled to megajoule class output operating at ≥ 10-Hz repetition rate. ARPA-E requested a study of the range of possibilities for a 100kJ/10-Hz laser system with >15% wall-plug efficiency operating below 360 nm. The conceptual design of a compact, 1 kJ class module is presented and analyzed for performance relative to the objectives along with a roadmap to demonstrate the technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and design of an airborne autonomous wavemeter for laser tuning

The development and design of an instrument for making water vapor Differential Absorption Lidar (DIAL) measurements from a down-looking airborne platform are described. The wavemeter device for this NASA-LASE (Lidar Atmospheric Sensing Experiment) project involves a classical Fabry-Perot interferometer approach. The interoferometer design, breadboard design, data retrieval algorithms, and errors are examined, and the design of the airborne instrument is discussed, including the illumination and imaging considerations, optomechanical component arrangement, electronic configuration, and proposed calibration technique.

Goad, Joseph H., Jr.↗

Single-shot measurement of the nonlinear refractive index of air at 92 µm with a picosecond terawatt CO 2 laser

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a welldefined, high-quality beam from a comparatively nonuniform quasi-flat-top beam which is typical for highpeak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, yielding n 2 = 3.0 × 10 -23 m 2 /W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

43 PARTICLE ACCELERATORS↗

Development of Advanced Seed Laser Modules for Lidar and Spectroscopy Applications

We report on recent progress made in the development of highly compact, single mode, distributed feedback laser (DFB) seed laser modules for lidar and spectroscopy applications from space based platforms. One of the intended application of this technology is in the NASA's Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The DFB laser modules operating at 1571 nm and 1262 nm have advanced current and temperature drivers built into them. A combination of temperature and current tuning allows coarse and fine adjustment of the diode wavelengths.

Prasad, Narasimha S.↗

Calibration of a tunable excimer laser using the optogalvanic effect

A device for the calibration of a tunable excimer laser is currently under development. The laser provides UV radiation at three principal wavelengths, 193, 248, and 308 nm and is tunable over a range of 1 nm at each of these wavelengths. The laser is used as a non-intrusive optical probe to excite electronic transitions, and thereby induce fluorescence, of the principle molecules or atoms of interest in supersonic flowfields, both reacting and nonreacting. The fluorescence resulting from the excitation is observed with an intensified camera. Over the range of tunability at the three wavelengths are a number of transitions that can be observed. The intensity of the fluorescence depends in part on the local temperature and density. The nature of this thermodynamic dependence is variable among transitions; thus, identification of the transition under observation is required. The specific transition excited corresponds directly to the wavelength of the radiation. The present technique used for transition identification consists of scanning the laser across the range of tunability and observing the fluorescence resulting from various molecular transitions.

Abbitt, John D.↗

Development and Testing of the Europa Mission's Venturi Flow Meter

NASA's Marshall Space Flight Center (MSFC), in collaboration with NASA's Goddard Space Flight Center (GSFC), Fox Valve Development Corp. and Oxford Lasers, is developing a set of venturi flow meters for use on the Europa Mission's propulsion subsystem. The requirement for the venturi flow meters' throat diameters is approximately 0.040". An early risk reduction activity conducted by MSFC revealed that a venturi flow meter produced by FOX with a throat diameter near 0.040" had much higher pressure loss than venturi flow meters with larger throat diameters and venturis of similar throat diameter size but with no pressure taps (i.e. venturis with a throat length to diameter ratio of zero). In response, a series of venturi flow meters was fabricated and flow tested to gain insight into pressure recovery as it is affected by pressure port diameter, throat length and diffuser angle in an effort to improve the performance of a venturi flow meter. This presentation provides a summary of the venturi flow meter development activity including: a description of the test's objectives, a detailed description of each venturi configuration, a description of the manufacturing processes of the venturis, and observations from the test data. A summary of the current development activities will also be given, as well as the current development path forward. Ultimately, the knowledge gained through the fabrication and testing of these venturis provides guidance to design a flight venturi flow meters with pressure recoveries that is acceptable for the Europa flight application.

Diaz, C. E.↗

Development of compact excimer lasers for remote sensing

The capabilities of excimer lasers for remote sensing applications are illustrated in a discussion of the development of a compact tunable XeCl excimer laser for the detection of atmospheric OH radicals. Following a brief review of the operating principles and advantages of excimer lasers, measurements of the wavelength dependence of the net small signal gain coefficient of a discharge excited XeCl laser are presented which demonstrate the overlap of several absorption lines of the A-X(0,0) transition of OH near 308 nm with the wavelengths of the XeCl laser. A range of continuous narrow bandwidth tunability of from 307.6 to 308.4 nm with only a 30 percent variation in output is reported for an XeCl laser used as a double-pass amplifier for a frequency-doubled dye laser, and measurements demonstrating the detection of laser-induced fluorescence from OH in a methane-oxygen flame are also noted. The design of an oscillator-amplifier excimer system comprising a corona-preionized, transverse-discharge oscillator and amplifier is then presented. Output energies of 12-15 mJ have been achieved in the regions where injection locking was established, with energies of 8-10 mJ elsewhere.

Laudenslager, J. B.↗