Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICAL ELECTRONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Application of Emerging Pharmaceutical Technologies for Therapeutic Challenges of Space Exploration Missions

An important requirement of therapeutics for extended duration exploration missions beyond low Earth orbit will be the development of pharmaceutical technologies suitable for sustained and preventive health care in remote and adverse environmental conditions. Availability of sustained, stable and targeted delivery pharmaceuticals for preventive health of major organ systems including gastrointestinal, hepato-renal, musculo-skeletal and immune function are essential to offset adverse effects of space environment beyond low Earth orbit. Specifically, medical needs may include multi-drug combinations for hormone replacement, radiation protection, immune enhancement and organ function restoration. Additionally, extended stability of pharmaceuticals dispensed in space must be also considered in future drug development. Emerging technologies that can deliver stable and multi-therapy pharmaceutical preparations and delivery systems include nanotechnology based drug delivery platforms, targeted-delivery systems in non-oral and non-parenteral formulation matrices. Synthetic nanomaterials designed with molecular precision offer defined structures, electronics, and chemistries to be efficient drug carriers with clear advantages over conventional materials of drug delivery matricies. Nano-carrier materials like the bottle brush polymers may be suitable for systemic delivery of drug cocktails while Superparamagnetic Iron Oxide Nanoparticles or (SPIONS) have great potential to serve as carriers for targeted drug delivery to a specific site. These and other emerging concepts of drug delivery and extended shelf-life technologies will be reviewed in light of their application to address health-care challenges of exploration missions. Innovations in alternate treatments for sustained immune enhancement and infection control will be also discussed.

Putcha, Lakshmi↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗

Crew Health and Performance Integrated Data System Platform Project Updates

Future human exploration missions introduce a new paradigm as crews move further from the resupply and near real-time ground support typical of Low Earth Orbit missions today. Without immediate support from ground-based personnel, exploration crews will be more reliant on inflight data and technology to respond to emergencies and anomalies. Today, in-flight data is often siloed, unsynchronized, and largely inaccessible in real time. Many data sets require manual entry and/or data transfer between vehicles and the ground. These issues contribute to risks in supporting crew autonomy for future exploration missions. An integrated data system platform is needed to mitigate these risks by supporting a new generation of technologies and employing advanced analytical and predictive modeling techniques to enable crew autonomy for future exploration missions. The Crew Health and Performance Integrated Data System Platform (CHP-IDSP) project is laying a foundation for future in-flight informatics by providing a back-end architecture for collecting, storing, and integrating multiple sources of data generated by and around the crew. This cohesive integration point will streamline the management of CHP data (e.g., environmental, exercise, medical, sleep, performance, etc.) and facilitate situation awareness and decision support required by the crew and remote support of exploration missions. This presentation will describe the ongoing development effort of the path-to-flight CHP-IDSP software and the demonstration of its core capabilities. This includes a brief history of the project, the human-centered process used to identify data needs and workflows feeding the development of scenarios and requirements, and current subsystem development status. Current integrations, including the Chiron exploration electronic health record application, will be discussed. Future work includes collaboration with additional CHP domains and a flight technology demonstration.

Data integration↗

Crew Health and Performance Integrated Data Service Platform (CHP-IDSP): Project Updates

Future human exploration missions introduce a new paradigm as crews move further from the resupply and near real-time ground support typical of Low Earth Orbit missions today. Without immediate support from ground-based personnel, exploration crews will be more reliant on inflight data and technology to respond to emergencies and anomalies. Today, in-flight data is often siloed, unsynchronized, and largely inaccessible in real time. Many data sets require manual entry and/or data transfer between vehicles and the ground. These issues contribute to risks in supporting crew autonomy for future exploration missions. An integrated data services platform is needed to mitigate these risks by supporting a new generation of technologies and employing advanced analytical and predictive modeling techniques to enable crew autonomy for future exploration missions. The Crew Health and Performance Integrated Data System Platform (CHP-IDSP) project is laying a foundation for future in-flight informatics by providing a back-end architecture for collecting, storing, and integrating multiple sources of data generated by and around the crew. This cohesive integration point will streamline the management of CHP data (e.g., environmental, exercise, medical, sleep, performance, etc.) and facilitate situation awareness and decision support required by the crew and remote support of exploration missions. This presentation will describe the ongoing development effort of the path-to-flight CHP-IDSP software and the demonstration of its core capabilities. This includes a brief history of the project, the human-centered process used to identify data needs and workflows feeding the development of scenarios and requirements, and current subsystem development status. Current integrations, including the Chiron exploration electronic health record application, will be discussed. Future work includes collaboration with additional CHP domains and a flight technology demonstration.

Software↗

Evidence-Based Recommendations for Optimizing Light in Day-to-Day Spaceflight Operations

NASA Behavioral Health and Performance Element (BHP) personnel have previously reported on efforts to transition evidence‐based recommendations for a flexible lighting system on the International Space Station (ISS). Based on these recommendations, beginning in 2016 the ISS will replace the current fluorescent‐based lights with an LED‐based system to optimize visual performance, facilitate circadian alignment, promote sleep, and hasten schedule shifting. Additional efforts related to lighting countermeasures in spaceflight operations have also been underway. As an example, a recent BHP research study led by investigators at Harvard Medical School and Brigham and Women's Hospital, evaluated the acceptability, feasibility, and effectiveness of blue‐enriched light exposure during exercise breaks for flight controllers working the overnight shift in the Mission Control Center (MCC) at NASA Johnson Space Center. This effort, along with published laboratory studies that have demonstrated the effectiveness of appropriately timed light for promoting alertness, served as an impetus for new light options, and educational protocols for flight controllers. In addition, a separate set of guidelines related to the light emitted from electronic devices, were provided to the Astronaut Office this past year. These guidelines were based on an assessment led by NASA's Lighting Environment Test Facility that included measuring the spectral power distribution, irradiance, and radiance of light emitted from ISS‐grade laptops and I‐Pads, as well as Android devices. Evaluations were conducted with and without the use of off‐the‐shelf screen filters as well as a software application that touts minimizing the short‐wave length of the visible light spectrum. This presentation will focus on the transition for operations process related to lighting countermeasures in the MCC, as well as the evidence to support recommendations for optimal use of laptops, I‐Pads, and Android devices during all phases of spaceflight operations.

Whitmire, Alexandra↗

JSC Director's Discretionary Fund 1992 Annual Report

Annual report of the Johnson Space Center Director's Discretionary Fund documenting effective use of resources. The $1,694,000 funding for FY92 was distributed among 27 projects. The projects are an overall aid to the NASA mission, as well as providing development opportunities for the science and engineering staff with eventual spinoff to commercial uses. Projects described include space-based medical research such as the use of stable isotopes of deuterium and oxygen to measure crew energy use and techniques for noninvasive motion sickness medication. Recycling essentials for space crew support is conducted in the Regenerative Life Support and the Hybrid Regenerative Water Recovery test beds. Two-phase fluid flow simulated under low-gravity conditions, hypervelocity particle impact on open mesh bumpers, and microcalorimetry to measure the long-term hydrazine/material compatibility were investigated. A patent application was made on a shape-memory-alloy release nut. Computer estimate of crew accommodations for advanced concepts was demonstrated. Training techniques were evaluated using multimedia and virtual environment. Upgrades of an electronic still camera provide high resolution images from orbit are presented.

Jenkins, Lyle↗

The Visible Human Project of the National Library of Medicine: Remote access and distribution of a multi-gigabyte data set

As part of the 1986 Long-Range Plan for the National Library of Medicine (NLM), the Planning Panel on Medical Education wrote that NLM should '...thoroughly and systematically investigate the technical requirements for and feasibility of instituting a biomedical images library.' The panel noted the increasing use of images in clinical practice and biomedical research. An image library would complement NLM's existing bibliographic and factual database services and would ideally be available through the same computer networks as are these current NLM services. Early in 1989, NLM's Board of Regents convened an ad hoc planning panel to explore possible roles for the NLM in the area of electronic image libraries. In its report to the Board of Regents, the NLM Planning Panel on Electronic Image Libraries recommended that 'NLM should undertake a first project building a digital image library of volumetric data representing a complete, normal adult male and female. This Visible Human Project will include digitized photographic images for cryosectioning, digital images derived from computerized tomography, and digital magnetic resonance images of cadavers.' The technologies needed to support digital high resolution image libraries, including rapid development; and that NLM encourage investigator-initiated research into methods for representing and linking spatial and textual information, structural informatics. The first part of the Visible Human Project is the acquisition of cross-sectional CT and MRI digital images and cross-sectional cryosectional photographic images of a representative male and female cadaver at an average of one millimeter intervals. The corresponding cross-sections in each of the three modalities are to be registerable with one another.

Ackerman, Michael J.↗

Twenty-First Century Research Needs in Electrostatic Processes Applied to Industry and Medicine

From the early century Nobel Prize winning (1923) experiments with charged oil droplets, resulting in the discovery of the elementary electronic charge by Robert Millikan, to the early 21st century Nobel Prize (2002) awarded to John Fenn for his invention of electrospray ionization mass spectroscopy and its applications to proteomics, electrostatic processes have been successfully applied to many areas of industry and medicine. Generation, transport, deposition, separation, analysis, and control of charged particles involved in the four states of matter: solid, liquid, gas, and plasma are of interest in many industrial and biomedical processes. In this paper, we briefly discuss some of the applications and research needs involving charged particles in industrial and medical applications including: (1) Generation and deposition of unipolarly charged dry powder without the presence of ions or excessive ozone, (2) Control of tribocharging process for consistent and reliable charging, (3) Thin film (less than 25 micrometers) powder coating and Powder coating on insulative surfaces, (4) Fluidization and dispersion of fine powders, (5) Mitigation of Mars dust, (6) Effect of particle charge on the lung deposition of inhaled medical aerosols, (7) Nanoparticle deposition, and (8) Plasma/Corona discharge processes. A brief discussion on the measurements of charged particles and suggestions for research needs are also included.

Mazumder, M. K.↗

Simulation of arthroscopic surgery using MRI data

With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

Heller, Geoffrey↗

Market Survey 2020: Commercial Clinical Decision Support Systems and Wellness Tools

For long-duration, deep space exploration missions, current methods for managing and supporting crew health and medical conditions will be unsuitable. Communication and data transmission lags will necessitate the use of a sophisticated clinical decision support system (CDSS) that will tailor diagnosis and treatment guidance that is context-sensitive for anticipated astronaut health, wellness, and medical conditions. A variety of clinical decision support (CDS) and wellness tools (WT) are currently available in the commercial market and a broad-brush survey of this market can provide an initial impression of the current state of the art which, in turn, can inform the roadmap of NASA deep space CDSS development and associated requirements. Such a survey was undertaken during the first six months of 2020 using directed convenience sampling to obtain information provided by vendors on their websites; both commercially available CDS and WT (such as those used to track and monitor nutrition, exercise, and sleep) were included. Areas assessed were item type (e.g., software/application, device); primary purpose of the item (e.g., diagnostic support, nutrition tracking); additional purposes (if any); reported features, capabilities, and functionality; setting of use (e.g., inpatient, outpatient); intended user (e.g., clinician, patient); location and sources of data/information used or produced by the item; integration with patient electronic health record (EHR); compliance with interoperability ontologies and standards (e.g., Health Level 7 [HL7], Systematized Nomenclature of Medicine – Clinical Terminology [SNOMED-CT]); and whether the item is knowledge-based (derived from research findings) or non-knowledge-based (derived through artificial intelligence, machine learning, advanced probability and statistics), among others. Ninety-seven (97) vendor websites describing 196 CDS and 73 WT (269 total) were reviewed and coded. The primary purpose of the majority of CDS reviewed is diagnosis or diagnosis/treatment/drug decision support—targeted for clinician use— and the primary purpose of the majority of WT reviewed is the monitoring of different health metrics, most often through the use of a biosensor device (e.g., blood pressure)—targeted for patient use. Very few CDS or WT appear to comply with major international interoperability standards or can be integrated with a patient’s EHR data. None consider contextual factors, such as conditions of the physical environment (e.g., CO2 levels). The majority of CDS and WT reviewed are non-knowledge, cloud- or web-based applications or software. Forty-three (43) major findings were identified and the implications those findings have for NASA will be discussed. Example major findings include: CDS-WT capabilities range from diagnosis to treatment applications, CDS-WT may be wearable or non-wearable and are technologically advanced and only a few CDS-WT tools referenced compliance to ensure interoperability, among other findings. Recommendations will also be offered that will help to address ExMC Gap, Medical-701: Enhance medical capabilities within an exploration medical system.

market survey↗

NASA spinoffs to bioengineering and medicine

Through the active transfer of technology, the National Aeronautics and Space Administration (NASA) Technology Utilization (TU) Program assists private companies, associations, and government agencies to make effective use of NASA's technological resources to improve U.S. economic competitiveness and to provide societal benefit. Aerospace technology from areas such as digital image processing, space medicine and biology, microelectronics, optics and electrooptics, and ultrasonic imaging have found many secondary applications in medicine. Examples of technology spinoffs are briefly discussed to illustrate the benefits realized through adaptation of aerospace technology to solve health care problems. Successful implementation of new technologies increasingly requires the collaboration of industry, universities, and government, and the TU Program serves as the liaison to establish such collaborations with NASA. NASA technology is an important resource to support the development of new medical products and techniques that will further advance the quality of health care available in the U.S. and worldwide.

Biomedical Engineering/instrumentation/trends↗

Closed Loop Control Compact Exercise Device for Use on MPCV

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. To combat spaceflight physiological deconditioning, astronauts will use resistive and aerobic exercise regimens for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the mass and volume available for an exercise device in the next generation of spacecraft is limited. Therefore, compact exercise device prototypes are being developed for human in the loop evaluations. The NASA Human Research Program (HRP) is managing Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation for all exploration mission profiles from Multi-Purpose Crew Vehicle (MPCV) exploration missions (e.g., EM-2, up to 21 day) to Mars Transit (up to 1000 day) missions. Numerous technologies have been considered and evaluated against HRP-approved functional requirements and include flywheel, pneumatic and closed-loop microprocessor-controlled motor driven power plants. Motor driven technologies offer excellent torque density and load accuracy characteristics as well as the ability to create custom mechanical impedance (the dynamic relationship between force and velocity) and custom load versus position exercise algorithms. Further, closed-loop motor-driven technologies offer the ability to monitor exercise dose parameters and adapt to the needs of the crewmember for real time optimization of exercise prescriptions. A simple proportional-integral-derivative (PID) controller is demonstrated in a prototype motor driven exercise device with comparison to resistive static and dynamic load set points and aerobic work rate targets. The resistive load term in the algorithm includes a constant force component (Fcmg) as well as inertial component (Fima) and a discussion of system tuning is presented in terms of addressing key functional requirements and human interfaces. The device aerobic modality is modelled as a rowing exercise using ground data sets obtained from Concept 2 rowers as well as competitive rowing1. A discussion of software and electronic implementations are presented which demonstrate unique approaches to meeting the constrained mass, volume and power requirements of the MPCV. . In addition to utilizing traditional PID control, controllers utilizing state feedback with gains solved using a Linear Quadratic Regulator will be developed. Controllability and observability will be utilized to investigate the need for state measurement in the design. As the control system directly interacts with human test subjects, robust methods such as H-infinity are also being investigated.1. Kleshnev V. Biomechanics. In: Rowing, Handbook of Sports Medicine and Science. ed. by Secher N., Voliantis S. IOC Medical Commission, Blackwell Pub. pp. 22-34, 2007

microgravity↗

Small Active Radiation Monitor

A device, named small active radiation monitor, allows on-orbit evaluations during periods of increased radiation, after extravehicular activities, or at predesignated times for crews on such long-duration space missions as on the International Space Station. It also permits direct evaluation of biological doses, a task now performed using a combination of measurements and potentially inaccurate simulations. Indeed the new monitor can measure a full array of radiation levels, from soft x-rays to hard galactic cosmic-ray particles. With refinement, it will benefit commercial (nuclear power-plant workers, airline pilots, medical technicians, physicians/dentists, and others) and military personnel as well as the astronauts for whom thermoluminescent dosimeters are inadequate. Civilian and military personnel have long since graduated from film badges to thermoluminescent dosimeters. Once used, most dosimeters must be returned to a central facility for processing, a step that can take days or even weeks. While this suffices for radiation workers for whom exposure levels are typically very low and of brief duration, it does not work for astronauts. Even in emergencies and using express mail, the results can often be delayed by as much as 24 hours. Electronic dosimeters, which are the size of electronic oral thermometers, and tattlers, small electronic dosimeters that sound an alarm when the dose/dose rate exceeds preset values, are also used but suffer disadvantages similar to those of thermoluminescent dosimeters. None of these devices fully answers the need of rapid monitoring during the space missions. Instead, radiation is monitored by passive detectors, which are read out after the missions. Unfortunately, these detectors measure only the absorbed dose and not the biologically relevant dose equivalent. The new monitor provides a real-time readout, a time history of radiation exposures (both absorbed dose and biologically relevant dose equivalent), and a count of the number of particles passing through a unit area. Better still, the monitor can be used anywhere.

Badhwar, Gautam D.↗

Programmable Cadence Timer

Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.

Hall, William A.↗

Using Electronic Noses to Detect Tumors During Neurosurgery

It has been proposed to develop special-purpose electronic noses and algorithms for processing the digitized outputs of the electronic noses for determining whether tissue exposed during neurosurgery is cancerous. At present, visual inspection by a surgeon is the only available intraoperative technique for detecting cancerous tissue. Implementation of the proposal would help to satisfy a desire, expressed by some neurosurgeons, for an intraoperative technique for determining whether all of a brain tumor has been removed. The electronic-nose technique could complement multimodal imaging techniques, which have also been proposed as means of detecting cancerous tissue. There are also other potential applications of the electronic-nose technique in general diagnosis of abnormal tissue. In preliminary experiments performed to assess the viability of the proposal, the problem of distinguishing between different types of cultured cells was substituted for the problem of distinguishing between normal and abnormal specimens of the same type of tissue. The figure presents data from one experiment, illustrating differences between patterns that could be used to distinguish between two types of cultured cancer cells. Further development can be expected to include studies directed toward answering questions concerning not only the possibility of distinguishing among various types of normal and abnormal tissue but also distinguishing between tissues of interest and other odorous substances that may be present in medical settings.

Homer, Margie L.↗

Spinoff 2012

Topics covered include: Water Treatment Technologies Inspire Healthy Beverages; Dietary Formulas Fortify Antioxidant Supplements; Rovers Pave the Way for Hospital Robots; Dry Electrodes Facilitate Remote Health Monitoring; Telescope Innovations Improve Speed, Accuracy of Eye Surgery; Superconductors Enable Lower Cost MRI Systems; Anti-Icing Formulas Prevent Train Delays; Shuttle Repair Tools Automate Vehicle Maintenance; Pressure-Sensitive Paints Advance Rotorcraft Design Testing; Speech Recognition Interfaces Improve Flight Safety; Polymers Advance Heat Management Materials for Vehicles; Wireless Sensors Pinpoint Rotorcraft Troubles; Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks; Detectors Ensure Function, Safety of Aircraft Wiring; Emergency Systems Save Tens of Thousands of Lives; Oxygen Assessments Ensure Safer Medical Devices; Collaborative Platforms Aid Emergency Decision Making; Space-Inspired Trailers Encourage Exploration on Earth; Ultra-Thin Coatings Beautify Art; Spacesuit Materials Add Comfort to Undergarments; Gigapixel Images Connect Sports Teams with Fans; Satellite Maps Deliver More Realistic Gaming; Elemental Scanning Devices Authenticate Works of Art; Microradiometers Reveal Ocean Health, Climate Change; Sensors Enable Plants to Text Message Farmers; Efficient Cells Cut the Cost of Solar Power; Shuttle Topography Data Inform Solar Power Analysis; Photocatalytic Solutions Create Self-Cleaning Surfaces; Concentrators Enhance Solar Power Systems; Innovative Coatings Potentially Lower Facility Maintenance Costs; Simulation Packages Expand Aircraft Design Options; Web Solutions Inspire Cloud Computing Software; Behavior Prediction Tools Strengthen Nanoelectronics; Power Converters Secure Electronics in Harsh Environments; Diagnostics Tools Identify Faults Prior to Failure; Archiving Innovations Preserve Essential Historical Records; Meter Designs Reduce Operation Costs for Industry; Commercial Platforms Allow Affordable Space Research; Fiber Optics Deliver Real-Time Structural Monitoring; Camera Systems Rapidly Scan Large Structures; Terahertz Lasers Reveal Information for 3D Images; Thin Films Protect Electronics from Heat and Radiation; Interferometers Sharpen Measurements for Better Telescopes; and Vision Systems Illuminate Industrial Processes.

Source record↗

Utility of MODIS Aerosol Optical Depth for Estimating PM2.5 Exposure in Environmental Public Health Surveillance

As part of the National Environmental Public Health Tracking Network (EPHTN) the National Center for Environmental Health (NCEH) at the Centers for Disease Control and Prevention (CDC) is leading a project called Health and Environment Linked for Information Exchange (HELIX-Atlanta). The goal of developing the National Environmental Public Health Tracking Network is to improve the health of communities. Currently, few systems exist at the state or national level to concurrently track many of the exposures and health effects that might be associated with environmental hazards. An additional challenge is estimating exposure to environmental hazards such as particulate matter whose aerodynamic diameter is less than or equal to 2.5 micrometers (PM(2.5)) HELIX-Atlanta's goal is to examine the feasibility of building an integrated electronic health and environmental data network in five counties of Metropolitan Atlanta, GA (Clayton, Cobb, DeKalb, Fulton, and Gwinnett counties). Under HELIX-Atlanta, pilot projects are being conducted to develop methods to characterize exposure; link health and environmental data; analyze the relationship between health and environmental factors; and communicate findings. NASA Marshall Space Flight Center (NASA/MSFC) is collaborating with CDC to combine NASA earth science satellite observations related to air quality and environmental monitoring data to model surface estimates of PM(2.5) concentrations that can be linked with clinic visits for asthma. From 1999-2000 there were over 9,400 hospitalizations per year in Georgia with asthma as the primary diagnosis. The majority of these hospitalizations occurred in medical facilities in the five most populous Metro-Atlanta counties. Hospital charges resulting from asthma in Georgia are approximately $59 million dollars annually. There is evidence in the research literature that asthmatic persons are at increased risk of developing asthma exacerbations with exposure to environmental factors, including PM(2.5). Thus, HELIX-Atlanta is focusing on methods for characterizing population exposure to PM(2.5) for the Atlanta metropolitan area that could be used in on-going surveillance. While use of the Air Quality System, (AQS) PM(2.5) data alone could meet HELIX Atlanta, specifications, there are only five AQS sites in the Atlanta area, thus the spatial coverage is not ideal. Also, the AQS ground observations are made at time intervals ranging from one hour to six days leaving some temporal gaps. NASA Moderate Resolution Imaging Spectroradiometer (MODIS) satellite Aerosol Optical Depth (AOD) data have the potential for estimating daily ground level PM(2.5) at 10 km resolution over the metropolitan Atlanta area supplementing the AQS ground observations and filling their spatial and temporal gaps.

Al-Hamdan, Mohammad↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗