Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured air temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SOAREX-8 Suborbital Experiments 2015 - A New Paradigm for Small Spacecraft Communication

In 2015 NASA plans to launch a payload to 280 Km altitude on a sounding rocket from the Wallops Flight Facility. This payload will contain several novel technologies that work together to demonstrate methodologies for space sample return missions and for nanosatellite communications in general. The payload will deploy and test an Exo-Brake, which slows the payload aerodynamically, providing eventual de-orbit and recovery of future ISS samples through a Small Payload Quick Return project. In addition, this flight addresses future Mars mission entry technology, space-to-space communications using the Iridium Short Messaging Service (SMS), GPS tracking, and wireless sensors using the ZigBee protocol. SOAREX-8 is being assembled and tested at Ames Research Center (ARC) and the NASA Engineering and Safety Center (NESC) is funding sensor and communications work. Open source Arduino technology and software are used for system control. The ZigBee modules used are XBee units that connect analog sensors for temperature, air pressure and acceleration measurement wirelessly to the payload telemetry system. Our team is developing methods for power distribution and module mounting, along with software for sensor integration, data assembly and downlink. We have demonstrated relaying telemetry to the ground using the Iridium satellite constellation on a previous flight, but the upcoming flight will be the first time we integrate useful flight test data from a ZigBee wireless sensor network. Wireless sensor data will measure the aerodynamic efficacy of the Exo-Brake permitting further on orbit flight tests of improved designs. The Exo-Brake is 5 sq m in area and will be stored in a container and deployed during ascent once the payload is jettisoned from the launch vehicle. We intend to further refine the hardware and continue testing on balloon launches, future sounding rocket flights and on nanosatellite missions. The use of standards-based and open source hardware/software has allowed for this project to be completed with a very modest budget and a challenging schedule. There is a wealth of hardware and software available for both the Arduino platform and the XBee, all low-cost or open-source. Along with the Exo-Brake hardware and deployment discussion, this paper will describe in detail the system architecture emphasizing the successful use of open source hardware and software to minimize effort and cost. Testing procedures, radio frequency interference (RFI) mitigation, success criteria and expected results will also be discussed. The use of Iridium short messaging capability for space-to-space links, standards-based wireless sensor networks, and other innovative communications technology are also presented.

aerobrake↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Prediction of annual soil respiration from its flux at mean annual temperature

Accurately scaling soil respiration (SR, the soil-to-atmosphere flow of CO2) across time and space is important to constrain and understand ecosystem to global scale SR, a major terrestrial carbon flux to the atmosphere. Year-round SR measurements are however expensive and sometimes impossible to perform. Bahn et al. (2010) developed an approach to estimate annual SR (SRannual) from the flux measured at mean soil temperature (SRMAST), but the robustness of this approach needs to be evaluated in diverse ecosystem types and climatic conditions globally. We used a global soil respiration database (SRDB-V4, with 823 SR observations worldwide) to test the capability of SRMAST to predict SRannual. SRMAST estimated using a variety of methods all showed clear relationships with annual SRannual. Two single-rate methods (i.e., using the single SR rate most close to mean annual soil temperature, or the single SR rate most close to mean annual air temperature) showed the most pronounced divergence from the true SRannual, but errors significantly decreased when using multiple SR rates within 1 ? of the mean annual soil temperature to estimate SRMAST. SRannual was most closely correlated with SRMAST estimated via a Q10 relationship, but this method has a potential autocorrelation issue that we explore and discuss. Air temperature data are much more widely available than is soil temperature, and we found that SR at mean annual air temperature (SRMAAT) can be used to predict SRannual as well. This study builds on Bahn et al. (2010) to demonstrate that SR measured at both annual mean soil and air temperature can be used to predict annual SR, with well-quantified errors. This capability could be used to reduce SR measurement frequency required for estimating SRannual and greatly decrease cost, factors that are generally important but especially in lower-income countries and cold, inaccessible regions.

Soil respiration, temperature, modeling↗

Research study: Thermal curtain permeability and thermal response test for SRB reentry

Nine inch diameter samples of the material which will provide thermal and acoustic protection between the nozzle and outer skirt on the space shuttle solid rocket boosters were subjected to heating tests to determine the porosity of the material and the thermal response to a step change in heating. For the porosity measurements a steady state flow of air at 70 F, 500 F, and 1000 F was passed through a sample of the curtain material and measurements of the flow rates were made at different pressure drops across the sample. For the transient measurements, a sample of the curtain material was subjected to a step change in temperature as air was passed through the sample. Measurements of the heat flow through the sample were made as a function of time after the input of the heat pulse. The sample consisted of three layers of curtain panels. Each panel was made of combinations of quartz and fiberglass cloth between which a fiberfrax filler material had been stitched. The hardware design and test procedures were described. Data are provided in engineering units for the flow conditions and and temperatures at which measurements were conducted.

Fuller, C. E.↗

LERCIP 2004 Summary

This summer I am continuing my project from the previous two summers. My work involves ohmic contacts to N-type silicon carbide (Sic) devices. My mentor, Dr. Robert Okojie, is developing the technology behind high performance sensors and actuators for harsh environments. Sic is useful because it is able to operate at temperatures up to 600 C and it is resistant to radiation damage. This allows sensors and electronics to be placed in new locations, such as inside a jet engine or in space application without using heavy shielding. Ultimately this results in more efficient, smarter engine technology, reduced launch weights for spacecraft, and high power and high temperature electronics. A fundamental part of Sic devices is the ohmic contact. The contact is the interface between the semiconductor (Sic) and external circuitry. The current flowing in and out the devices is through the contact. Ensuring that these contacts remain ohmic (linear I-V behavior) allows us to fabricate devices that do not waste power at the metallurgical junction. Another key part is maintaining a low contact resistance. It is desired to maintain minimum energy loss by avoiding a rectifying electrical characteristic. My project is to develop and implement a testing procedure for measuring the contact resistance while the device is operating at high temperature. It is important to measure the contacts while simulating the true operating environment as closely as possible. For this reason, measurements are taken while the device is heated at intervals up to 600 C in air. To test the long tern reliability of the devices, the high temperature measurements are repeated after heating the sample for long intervals in air. A new set of data is gathered after heating for a total of 100, 200 and then 400 hours. The current as a function of voltage and the contact resistance was measured using the four point probe technique. The four point probe method is chosen because it measures contact resistance while eliminating error due to wire resistance and calibration issues.

DeAngelis, David↗

Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

Bever, R. S.↗

The role of surface generated radicals in catalytic combustion

Experiments were conducted to better understand the role of catalytic surface reactions in determining the ignition characteristics of practical catalytic combustors. Hydrocarbon concentrations, carbon monoxide and carbon dioxide concentrations, hydroxyl radical concentrations, and gas temperature were measured at the exit of a platinum coated, stacked plate, catalytic combustor during the ignition of lean propane-air mixtures. The substrate temperature profile was also measured during the ignition transient. Ignition was initiated by suddenly turning on the fuel and the time to reach steady state was of the order of 10 minutes. The gas phase reaction, showed no pronounced effect due to the catalytic surface reactions, except the absence of a hydroxyl radical overshoot. It is found that the transient ignition measurements are valuable in understanding the steady state performance characteristics.

Santavicca, D. A.↗

BOREAS TGB-1/TGB-3 Water Table and Peat Temperature Data over the NSA

The BOREAS TGB-1 and TGB-3 teams collected several data sets that contributed to understanding the measured trace gas fluxes over sites in the NSA. This data set contains continuous and manual measurements of water level and air and soil temperatures at the four subsites within the NSA Tower Fen site complex. The measurements were taken to understand the thermal and hydrological gradients associated with each plant community present in the fen. Measurements were taken from May to September 1994 and May to October 1996. The data are provided in tabular ASCII files.

Bubier, Jill L.↗

Mathematical and experimental investigation of heat control and power increase in air-cooled aircraft engines

In order to understand the numerical relations between the air velocity, temperature of the cylinder walls, heat dissipation, cylinder dimensions and type of construction an experimental plant was installed in the Siemens and Halske laboratory. The experimental cylinder was exposed to the air stream of a wind tunnel. The compression chamber was heated by an electrically heated oil bath kept constantly in motion by a stirrer. The wall temperatures were measured by thermocouples. The air stream was produced a seven-watt blower. The air flowed through a current rectifier (honeycomb), diffuser, air chamber with quieting sieves and a nozzle.

ENGINES - AIR COOLED - POWER INCREASES↗

N2/O2/H2 Dual-Pump Cars: Validation Experiments

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.

OByrne, S.↗

Thermal effects on the mechanical properties of SiC fiber reinforced reaction bonded silicon nitride matrix (SiC/RBSN) composites

The elevated temperature four-point flexural strength and the room temperature tensile and flexural strength properties after thermal shock were measured for ceramic composites consisting of 30 vol pct uniaxially aligned 142 micron diameter SiC fibers in a reaction bonded Si3N4 matrix. The elevated temperature strengths were measured after 15 min of exposure in air at temperatures to 1400 C. Thermal shock treatment was accomplished by heating the composite in air for 15 min at temperatures to 1200 C and then quenching in water at 25 C. The results indicate no significant loss in strength properties either at temperature or after thermal shock when compared with the strength data for composites in the as-fabricated condition.

Bhatt, R. T.↗

Thermal effects on the mechanical properties of SiC fibre reinforced reaction-bonded silicon nitride matrix composites

The elevated temperature four-point flexural strength and the room temperature tensile and flexural strength properties after thermal shock were measured for ceramic composites consisting of 30 vol pct uniaxially aligned 142 micron diameter SiC fibers in a reaction bonded Si3N4 matrix. The elevated temperature strengths were measured after 15 min of exposure in air at temperatures to 1400 C. Thermal shock treatment was accomplished by heating the composite in air for 15 min at temperatures to 1200 C and then quenching in water at 25 C. The results indicate no significant loss in strength properties either at temperature or after thermal shock when compared with the strength data for composites in the as-fabricated condition.

Bhatt, R. T.↗

Simultaneous temperature and multi-species measurements in opposed jet flames of nitrogen-diluted hydrogen and air

A narrowband UV Raman scattering system is used to obtain measurement profiles of major and minor species concentrations, temperature, and mixture fraction in opposed jet diffusion flames. The measurement profiles can be compared to previously obtained temperature and concentration profiles (Pellett et al., 1989), obtained using CARS, and they can also be qualitatively compared to the predicted concentration and temperature profiles in pure hydrogen/air flames (Gutheil and Williams, 1990) and in diluted hydrogen/air flames (Dixon-Lewis and Missaghi, 1988; Ho and Isaac, 1991). The applied stress-rates for the two flame conditions studied are 240/s and 340/s, with respective hydrogen concentrations in the fuel jet of 0.67 and 0.83, on a mole fraction basis (0.13 and 0.26 hydrogen mass fractions, respectively).

Wehrmeyer, J. A.↗

An Anaylsis of Control Requirements and Control Parameters for Direct-Coupled Turbojet Engines

Requirements of an automatic engine control, as affected by engine characteristics, have been analyzed for a direct-coupled turbojet engine. Control parameters for various conditions of engine operation are discussed. A hypothetical engine control is presented to illustrate the use of these parameters. An adjustable speed governor was found to offer a desirable method of over-all engine control. The selection of a minimum value of fuel flow was found to offer a means of preventing unstable burner operation during steady-state operation. Until satisfactory high-temperature-measuring devices are developed, air-fuel ratio is considered to be a satisfactory acceleration-control parameter for the attainment of the maximum acceleration rates consistent with safe turbine temperatures. No danger of unstable burner operation exists during acceleration if a temperature-limiting acceleration control is assumed to be effective. Deceleration was found to be accompanied by the possibility of burner blow-out even if a minimum fuel-flow control that prevents burner blow-out during steady-state operation is assumed to be effective. Burner blow-out during deceleration may be eliminated by varying the value of minimum fuel flow as a function of compressor-discharge pressure, but in no case should the fuel flow be allowed to fall below the value required for steady-state burner operation.

Novik, David↗

Estimation of tropical forest canopy temperatures, thermal response numbers, and evapotranspiration using an aircraft-based thermal sensor

Thermal infrared Multispectral Scanner (TIMS) data were collected at a resolution of 5 to 10 m from a tropical rain forest over an elevation gradient from 35 to 2700 m in the Braulio Carrillo National Park in Costa Rica. Flight lines were repeated with a 15 to 30 minute time difference for measurement of forest canopy thermal response over time. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture provided inputs to LOWTRAN6 for atmospheric radiance corrections of the TIMS data. Techniques for using calibrated aircraft-based thermal scanner data to examine tropical forest canopy thermal properties are described. Forest canopy temperature changes over time assessed between repeated, duplicated flight lines were combined with estimates of surface radiative energy measurements from towers above the forest canopy to determine temperature spatial variability, calculate Thermal Response Numbers (TRN), and estimate evapotranspiration along the elevation gradient from selected one hectare forest inventory plots.

Luvall, Jeffrey C.↗

Temperature Mapping Above and Below Air Film-Cooled Thermal Barrier Coatings Using Phosphor Thermometry

Thermal barrier coatings (TBCs) are typically used in conjunction with air film cooling to maximize overall cooling effectiveness and reliability while minimizing sacrifices in engine performance. The effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness have usually been studied separately; however, their contributions to combined cooling effectiveness are interdependent and are not simply additive. The combined cooling effectiveness is always less than the sum of the cooling effectiveness of stand-alone TBC protection and stand-alone air film cooling. These diminishing returns arise because adding the thermally insulating TBC between the cooling air and the surface to be cooled reduces the air film cooling effectiveness and because the air film cooling reduces the heat flux through the TBC and therefore reduces the temperature difference sustained across the TBC thickness. Due to these considerations, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. In this investigation, temperature mapping above and below air film-cooled TBCs was performed using luminescence lifetime imaging-based phosphor thermometry. Measurements were performed in the NASA GRC Mach 0.3 burner rig on a TBC-coated plate using a scaled-up cooling hole geometry where both the hot mainstream gas temperature and the blowing ratio were varied. Surface temperature maps were obtained from a Cr-doped GdAlO3 thermographic phosphor deposited on the surface of the electron-beam vapor-deposited yttria-stabilized zirconia (YSZ) TBC. From separate plates, temperature maps from the bottom of the TBC were obtained from a thin Er-doped YSZ layer integrated into the TBC below the overlying undoped YSZ. Procedures for temperature and cooling effectiveness mapping above and below the air film-cooled TBC surface are described. Most importantly, these measurements enable mapping the combined cooling effectiveness below the TBC, which is more important than surface cooling effectiveness when there is a barrier coating between the hot mainstream gas and the surface that needs thermal protection. Advantages of the luminescence lifetime imaging method over infrared thermography, as well as its limitations to steady-state conditions are discussed.

cooling effectiveness.↗

Ocean-Atmosphere Interaction Over Agulhas Extension Meanders

Many years of high-resolution measurements by a number of space-based sensors and from Lagrangian drifters became available recently and are used to examine the persistent atmospheric imprints of the semi-permanent meanders of the Agulhas Extension Current (AEC), where strong surface current and temperature gradients are found. The sea surface temperature (SST) measured by the Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E) and the chlorophyll concentration measured by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) support the identification of the meanders and related ocean circulation by the drifters. The collocation of high and low magnitudes of equivalent neutral wind (ENW) measured by Quick Scatterometer (QuikSCAT), which is uniquely related to surface stress by definition, illustrates not only the stability dependence of turbulent mixing but also the unique stress measuring capability of the scatterometer. The observed rotation of ENW in opposition to the rotation of the surface current clearly demonstrates that the scatterometer measures stress rather than winds. The clear differences between the distributions of wind and stress and the possible inadequacy of turbulent parameterization affirm the need of surface stress vector measurements, which were not available before the scatterometers. The opposite sign of the stress vorticity to current vorticity implies that the atmosphere spins down the current rotation through momentum transport. Coincident high SST and ENW over the southern extension of the meander enhance evaporation and latent heat flux, which cools the ocean. The atmosphere is found to provide negative feedback to ocean current and temperature gradients. Distribution of ENW convergence implies ascending motion on the downwind side of local SST maxima and descending air on the upwind side and acceleration of surface wind stress over warm water (deceleration over cool water); the convection may escalate the contrast of ENW over warm and cool water set up by the dependence of turbulent mixing on stability; this relation exerts a positive feedback to the ENW-SST relation. The temperature sounding measured by the Atmospheric Infrared Sounder(AIRS) is consistent with the spatial coherence between the cloud-top temperature provided by the International Satellite Cloud Climatology Project (ISCCP) and SST. Thus ocean mesoscale SST anomalies associated with the persistent meanders may have a long-term effect well above the midlatitude atmospheric boundary layer, an observation not addressed in the past.

Atmospheric Infrared Sounder (AIRS)↗