Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Promoting the regulatory acceptance of combined ion and neutron irradiation for material degradation in nuclear reactors

The Advanced Materials and Manufacturing Technologies (AMMT) program within the Department of Energy (DOE) Office of Nuclear Energy has developed its current recommendation for promoting the use of combined ion irradiation and neutron irradiation for the accelerated qualification of materials to be deployed in nuclear reactors. This plan is intended to provide a collaborative path forward that can be adopted by academia, national laboratories, and industry, and has been developed with input from the regulatory research arm of the U.S. Nuclear Regulatory Commission (NRC). To deploy new materials or materials manufactured with new technologies, such as additive manufacturing, materials must be evaluated for reactor-induced degradation from the combination of harsh temperatures, corrosive environments, and radiation fields. However, rapid deployment of materials necessitates accelerated testing methods rather than relying on years of neutron irradiation in a material test reactor. Ion irradiation has demonstrated success in reproducing material microstructure and select property evolution resulting from neutron irradiation with three to four orders of magnitude reduction in time and cost, making it an ideal candidate for accelerated irradiation testing. This presentation provides context governing both the scientific and regulatory aspects of the proposed goal. The discussion is aimed at a broad audience including researchers from industry, national laboratories, and academia. The recommended path forward is presented as a conceptual framework of specific steps. In brief, the strategy entails developing an integrated ion and neutron irradiation test plan for the material property of interest based on the fundamental tenet of the linkage of microstructure and properties in materials. Physics-based modeling interprets ion irradiation data and predicts neutron irradiation microstructure and properties with uncertainty bounds. The first round of testing is sufficient for an initial licensing application using a risk-informed approach, while a minimum required neutron irradiation test plan reduces cost and time requirements. A surveillance program with witness specimens in-reactor provides additional data over time to improve model predictions to higher damage levels and further reduce uncertainty bounds, which can be used for license extensions or longer lifetimes in new license applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Magnetic pair distribution function and half polarized neutron powder diffraction at the HB-2A powder diffractometer

Local magnetic order and anisotropy are often central for understanding fundamental behavior and emergent functional properties in quantum materials and beyond. Advances in neutron powder diffraction experiments and analysis tools now allow for quantitative determination. Here, we demonstrate this here with complementary total neutron scattering and polarized neutron measurements on the HB-2A neutron powder diffractometer at the High Flux Isotope Reactor (HFIR). In recent years, magnetic pair distribution function (mPDF) analysis has emerged as a powerful technique for probing local magnetic spin ordering of magnetic materials. This method can be broadly applied to any magnetic material but is particularly effective for studying systems with short-range magnetic order, such as materials with reduced dimensionality, geometrically frustrated magnets, thermoelectrics, multiferroics, and correlated paramagnets. Magnetic anisotropy often underpins the short-range order adopted. Half-polarized neutron powder diffraction (pNPD) can be used to determine the local susceptibility tensor on the magnetic sites to quantify the magnetic anisotropy. Combining the techniques of mPDF and pNPD can therefore provide valuable insights into local magnetic behavior. A series of measurements optimized for these techniques are presented as exemplar cases focused on frustrated materials where short-range order dominates, these include measurements to ultra-low temperature (<100 mK) not typically accessible for such experiments.

Half polarized neutron scattering↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Neutron Scattering in Sodium-Ion Battery Research: Progress and Prospects

Sodium-ion batteries have attracted renewed interest in recent years and are widely studied as a complementary power source to Li-ion batteries for large-scale stationary energy storage and small electric vehicles. Compared with Li-ion batteries, Na-ion batteries offer several advantages, including elemental abundance, lower cost, improved safety, and better low-temperature performance. An in-depth understanding of Na-ion batteries across multiple length and time scales has further accelerated the rapid development of this technology. Among the various advanced characterization techniques used to study Na-ion batteries, neutron scattering has gained significant traction in recent years. It has become a powerful and versatile tool for probing structure, morphology, and sodium-ion dynamics over a wide range of length and time scales. In this article, we will briefly review the development of neutron scattering technology and highlight recent advances in applying neutron-based techniques—including neutron diffraction, total scattering, small-angle scattering, quasi-elastic/inelastic scattering, and neutron imaging—to Na-ion battery materials. We also provide perspectives on future technique developments, particularly in the realm of in situ and operando neutron scattering characterization, and discuss how these approaches could further enhance our understanding of Na-ion battery systems.

Liu, Jue [ORNL] (ORCID:000000024453910X)↗

Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Comparison of hardening and microstructures of ferritic/martensitic steels irradiated with fast neutrons and dual ions

Ferritic/martensitic steels T91 and HT9 were irradiated with neutrons (BOR-60 reactor) and dual ions (9 MeV Fe 3+ and 3.42 MeV energy degraded He 2+ ) from 369 to 520 °C and damage levels of 16.6 to 72 dpa to quantify the possibility of using ion irradiation to simulate neutron irradiation in terms of microstructures and mechanical properties. Nanoindentation testing was performed to obtain the bulk equivalent hardness of the dual-ion irradiated samples. For the neutron irradiated samples, both nanoindentation and Vickers hardness testing were conducted. Transmission Electron Microscopy (TEM) characterizations of the cavities, dislocation loops and precipitates were conducted to account for the strengthening contribution of each microstructure element. The good agreement between the microstructure-predicted (dispersed barrier hardening) and measured strength of the irradiated specimens demonstrated the accuracy of the strengthening model and the nanoindentation tests. Furthermore, the comparison of mechanical property and microstructure changes in ion and neutron irradiated structural materials indicated that ion irradiation replicated many neutron irradiation features. However, a single 70 °C temperature shift is insufficient to match all complex microstructures of neutron vs. ion irradiation over the irradiation temperature range of 369–520 °C.

36 MATERIALS SCIENCE↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Conceptual Design of the Moderator Test Station at the Spallation Neutron Source

We describe the Moderator Test Station (MTS), under construction at the Spallation Neutron Source. We will leverage the Beam Test Facility (BTF) at the Spallation Neutron Source to provide a moderator neutronics test stand with which we will verify the anticipated performance gains expected and required from the innovative moderator concepts central to the SNS Second Target Station (STS) and the future of the First Target Station (FTS). These concepts include large-volume para-hydrogen moderators and high-brightness tube moderators. The MTS will add to the existing BTF a proton beam chopper similar to that already used in the SNS at the RFQ exit (the so-called MEBT chopper), various proton beam transport components, a neutron-producing target, a cryogenic moderator test stand, a reflector-shielding assembly, and a performance assessment neutron beamline. The MTS will provide the ability to test a wide variety of moderators in a prototypic configuration, simultaneously measuring the neutronic performance of the moderator concept central to the anticipated STS gains and developing the instrumentation necessary to provide that performance in a production environment. The presentation will describe the MTS, its progress, and the way we optimize the prototypic nature of the moderators we will test.

Iverson, Erik B↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗

High-pressure neutron diffraction at ultra-low temperature

Neutron diffraction is a powerful tool in the study of quantum materials and associated emergent phenomena as it allows for direct detection of magnetic structure even at ultra-low temperatures. As pressure can drive systems across quantum critical points and tune emergent behaviors at the quantum scale, coupling neutron diffraction with extreme conditions of high pressure at (ultra-)low temperatures has been a key research target over decades. This has proven challenging as magnetic neutron diffraction typically requires large sample volumes due to flux limitations, whereas high-pressure studies require small sample volumes due to pressure limitations. Combining these two contradictory requirements poses many difficulties, but also brings opportunities in research and development. Here, we address these shortcomings through the use of a diamond anvil cell equipped with polycrystalline anvils with relatively large sample volumes coupled with the high neutron flux made available by the high-pressure diffractometer of the Spallation Neutron Source. This particular diamond anvil cell configuration has previously proven useful for single-crystal samples and is here coupled with the ultra-low temperatures of a dilution refrigerator for the first time. Our study on a single crystal of Yb 2 ⁢O 3 successfully collected magnetic neutron diffraction data at 5.3 GPa below 200 mK inside a dilution refrigerator. We have performed a detailed analysis of the magnetic diffraction data to investigate the magnetic structure under pressure and observed a subtle shift in the transition temperature. This development will open the door for future studies on magnetic materials with these much-desired coupled extremes of high pressure and ultra-low temperatures.

Wu, Yan [Oak Ridge National Laboratory (ORNL), Oak↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A field-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt γ-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium γ-ray detector. Fine spatial resolution neutron and α detectors enable precise mapping of characteristic γ-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus significantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

Bucher, Brian [Idaho National Laboratory (INL)]↗