Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATOR PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

The Value of Forecasters‐in‐the‐Loop in Real‐Time Flood Forecasting in the Age of Machine Learning

Machine learning (ML) applications in hydrological forecasting are increasingly prevalent and show great potential. However, many previous studies have only evaluated performance through reanalysis or retrospective simulations compared to simplified baselines. This study provides the first assessment of ML performance against actual operational forecasting systems operated by the California Nevada River Forecast Center (CNRFC), which combines the Community Hydrologic Prediction System (CHPS) with forecasters-in-the-loop. Results demonstrate that forecasters-in-the-loop systems consistently outperform ML models in both general forecasts and flood alerting across lead times up to 96 hr, even when ML models use observed forcings, while CNRFC operational process relies on biased weather forecasts. Our analysis reveals that forecaster expertise maintains forecast reliability despite inaccurate precipitation inputs, with human-guided systems showing superior performance degradation characteristics at extended lead times. These findings highlight the irreplaceable value of human expertise in operational forecasting and caution against overstating current ML capabilities in real-world applications.

Tran, Vinh Ngoc [Univ. of Michigan, Ann Arbor, MI ↗

WEC-Sim Modeling of Laminar Scientific's Patented Seesaw Wave Energy Converter: Preprint

Laminar Scientific's patented seesaw wave energy converter was modeled in WEC-Sim to predict performance. The device operates by utilizing ocean surface waves to rotate a truss in pitch about a pivot. The pivot is located at the top of two pylons, which are embedded in the seafloor. The seesaw has a float on either end, and the buoyancy forces from each float cause the system to rise or fall with passing waves. Device performance relies upon seesaw length and ocean wavelength creating an antiphase effect. The seesaw truss has an adjustable length intended to achieve this effect. The operation method enforces a narrow band of wavelengths which induce the largest rotational motion from the device. The hydrodynamic analysis of the device was performed using Capytaine, and the results confirmed that the device operates best in a narrow frequency band. Four float-to-float spacing cases and three pylon radii were examined. The hydrodynamic results indicate a match between the model and the physical expectations for the device, and that varying the pylon radii by 0.1-m increments for three instances creates minimal changes in hydrodynamic properties. Power matrices for three float spacing cases of the device were simulated with Joint North Sea Wave Project spectra waves and optimal power take-off damping in WEC-Sim. The maximum average power production for the 15-m spacing case was 14.1 kW with a 5.0-s peak wave period and 4-m significant wave heights. Plots of capture-width ratios indicated that the device performance was linear and confirmed that the device is optimal in a narrow frequency band. The maximum percentage of the available wave power produced by the 15-m device was approximately 16%. Simulations of the device in regular waves were used to produce plots of average power compared to a ratio of float spacing to wavelength. These plots indicate that the power production is maximized at a ratio of 0.5, and further confirm that the device has a narrow frequency response. The device was simulated at an example field location, where the device produced an annual average power rating of 1.6 kW given an average omnidirectional wave climate of 10.3 kW m-1 and an optimal, linearized power take-off model. While the maximum predicted device performance is reliant upon a narrow band of wave frequencies, the conducted analysis provides an opportunity to improve device design prior to prototyping and testing. Modifying the design to respond to a broader frequency range would improve device performance.

numerical modeling↗

A new metrics framework for quantifying and intercomparing atmospheric rivers in observations, reanalyses, and climate models

We present a new atmospheric river (AR) analysis and benchmarking tool, namely Atmospheric River Metrics Package (ARMP). It includes a suite of new AR metrics that are designed for quick analysis of AR characteristics via statistics in gridded climate datasets such as model output and reanalysis. This package can be used for climate model evaluation in comparison with reanalysis and observational products. Integrated metrics such as mean bias and spatial pattern correlation are efficient for diagnosing systematic AR biases in climate models. For example, the package identifies the fact that, in CMIP5 and CMIP6 (Coupled Model Intercomparison Project Phases 5 and 6) models, AR tracks in the South Atlantic are positioned farther poleward compared to ERA5 reanalysis, while in the South Pacific, tracks are generally biased towards the Equator. For the landfalling AR peak season, we find that most climate models simulate a completely opposite seasonal cycle over western Africa. This tool can also be used for identifying and characterizing structural differences among different AR detectors (ARDTs). For example, ARs detected with the Mundhenk algorithm exhibit systematically larger size, width, and length compared to the TempestExtremes (TE) method. The AR metrics developed from this work can be routinely applied for model benchmarking and during the development cycle to trace performance evolution across model versions or generations and set objective targets for the improvement of models. They can also be used by operational centers to perform near-real-time climate and extreme event impact assessments as part of their forecast cycle.

58 GEOSCIENCES↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of grain size and porosity on cladding failure in high-burnup UO 2 : A sensitivity and uncertainty study

Isotopic taggants are being studied to aid in the provenance assessment of nuclear materials. However, these taggants must be selected such that they do not adversely affect fuel performance during normal operation or accident scenarios. Taggants are known to affect the fuel’s grain size and porosity. In the work described in this paper, the BISON fuel performance code was used to assess the potential effects of taggants (i.e., grain size and porosity) on fuel rod behavior and cladding failure during a high-burnup, large-break loss-of-coolant accident. Here, 281 individual fuel rods from the same reactor core were modeled for a sensitivity study, a parametric study, and uncertainty quantification. The cladding failure predictions often exhibited stochastic behavior. After additional study, it was found that the cladding failure model is highly sensitive to residual error inherent to numerical approximation solvers. Some strategies to mitigate this sensitivity are discussed. The study found no relationship between known taggant effects and cladding failure status. However, taggants were found to affect the time and location of failure in certain rods. In conclusion, future work to continue investigating and validating these findings is briefly discussed.

Doped UO 2↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Efficient Sparse Computations using Linear Algebra Aware Compilers

This project developed the LAPIS compiler framework, built on the Multilevel Intermediate Representation (MLIR), to optimize sparse linear algebra operations and support performance portability across diverse architectures. The main innovation of LAPIS is the Kokkos dialect, which allows for lowering codes from a high productivity language to different architectures in an elegant way. The dialect also allows the conversion of lower-level MLIR code to C++ Kokkos code, facilitating the integration of scientific machine learning (SciML) models into applications. To extend LAPIS for distributed memory architectures, a new partition dialect was created to manage the distribution of sparse tensors and express communication patterns for sparse linear algebra operations. This dialect also supports the distributed execution of operators and includes algorithmic optimizations to minimize communication to improve performance. The project also demonstrates that MLIR can enable effective linear algebra-level optimizations, improving performance on different GPUs for both sparse and dense linear algebra kernels. Key applications of LAPIS include sparse linear algebra and graph kernels, TenSQL, a relational database management solution built on GraphBLAS, and the development of subgraph isomorphism and monomorphism kernels, showcasing performance portability. In summary, the LAPIS framework supports productivity, performance, portability, and distributed memory execution, while also enabling linear algebra-level optimizations that are challenging in traditional programming languages, with successful applications ranging from simple sparse linear algebra to complex graph kernels.

97 MATHEMATICS AND COMPUTING↗

CMOS-Based Single-Cycle in-Memory XOR/XNOR

Big data applications are on the rise, and so is the number of data centers. The ever-increasing massive data pool needs to be periodically backed up in a secure environment. Moreover, a massive amount of securely backed-up data is required for training binary convolutional neural networks for image classification. XOR and XNOR operations are essential for large-scale data copy verification, encryption, and classification algorithms. The disproportionate speed of existing compute and memory units makes the von Neumann architecture inefficient to perform these Boolean operations. Compute-in-memory (CiM) has proved to be an optimum approach for such bulk computations. The existing CiM-based XOR/XNOR techniques either require multiple cycles for computing or add to the complexity of the fabrication process. Here, we propose a CMOS-based hardware topology for single-cycle in-memory XOR/XNOR operations. Our design provides at least 2× improvement in the latency compared with other existing CMOS-compatible solutions. We verify the proposed system through circuit/system-level simulations and evaluate its robustness using a 5000-point Monte Carlo variation analysis. This all-CMOS design paves the way for practical implementation of CiM XOR/XNOR at scaled technology nodes.

97 MATHEMATICS AND COMPUTING↗

Amorphous-crystalline transition-driven synthesis of Co single-atom catalysts on MoO 3 for enhanced hydrogen evolution in acidic and alkaline media

Single atom catalysts (SACs) dispersed in metal oxide supports offer not only maximized catalyst utilization but also extended modulation capabilities through interactions between the SA and its support. However, achieving facile preparation and ensuring electrochemical durability of such SACs, particularly for hydrogen evolution reaction (HER) applications, remain formidable challenges. Here, our study addresses these issues by employing an amorphous-to-crystalline phase transition in MoO 3 to synthesize a cobalt (Co) SA catalyst. This method facilitates the production of highly selective SA catalysts at low temperatures and ensures their enhanced stability in HER applications. The Co SA MoO 3 catalyst exhibits superior performance in HER, operating effectively in both acidic and alkaline environments. Significantly, it maintains stable HER activity across these diverse electrolytic conditions. Our Density Functional Theory (DFT) calculations provide insights into the exceptional HER performance of Co SA MoO 3 . These calculations reveal that the strong affinity for hydrogen and water, facilitated by the modulation of the p-band orbitals at specific oxygen sites adjacent to the Co SA, establishes a thermoneutral pathway for HER. This study represents a pivotal advancement, showcasing a highly practical and robust single-atom catalyst, marking a significant stride towards sustainable energy solutions.

36 MATERIALS SCIENCE↗

Comparison of the Effects of Bipolar Membrane Preparation Conditions on the Mechanical Durability and Electrochemical Performance for Electrodialysis Applications

Bipolar membranes (BPMs) are enabling materials for electrochemical conversion technologies such as water electrolysis, fuel cells, CO 2 electrolysis, and electrodialysis (ED) for direct air/ocean capture of CO 2 . However, current BPM durability can suffer from chemical, mechanical, and performance degradation when operated at high current density (ion flux) and physical scale. Therefore, this limits its adoption in a wider applications space. BPMs have several known degradation mechanisms, including chemical breakdown of ion-exchange polymers, loss of junction adhesion, or physical breakdown due to shearing force and pressure swings in an electrodialysis cell. To assess the electrochemical stability and mechanical durability of BPMs under operational conditions, we investigated how fabrication conditions (including preconditioning, hot-pressing temperature and pressure, and catalyst loading) impact the adhesion of custom-made BPMs. T-peel studies were performed ex situ to quantify adhesive forces of BPMs, and bipolar membrane electrodialysis (BPMED) experiments were performed to assess the electrochemical performance of the corresponding BPMs. The results of this systematic comparison indicate that hydration and heated pressing create improved adhesion during the fabrication of BPMs, and BPMED testing shows that these fabrication techniques are not detrimental to the electrochemical performance of the BPMs.

36 MATERIALS SCIENCE↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Advanced Polymer Characterization: Modular Operations for Spectral Alignment by Iterative Compression (MOSAIC)

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry encodes structural information across diverse homo- and copolymer ensembles, yet decrypting these spectra requires a systematic analytical approach. We introduce Modular Operations for Spectral Alignment by Iterative Compression (MOSAIC)─a general cipher algorithm that applies modular arithmetic to filter monomer-derived mass contributions and cluster MALDI peaks by nonconstitutional repeating units (non-CRUs). MOSAIC performs sequential modular operations using monomer mass differences as base units to compress complex spectral data, revealing end-group distributions and comonomer incorporation. As a demonstration, we applied MOSAIC to five copolymers formed by two different polymerization mechanisms. Furthermore, the resulting remainder–mass plots clearly resolve polymer homologs with distinct non-CRUs into visually apparent clusters, enabling intuitive assignment of mass spectral features.

Wang, Hanlin M. [University of Illinois at Urbana−↗