Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Doubling protected land area may be inefficient at preserving the extent of undeveloped land and could cause substantial regional shifts in land use

Abstract Projection of land use and land‐cover change is highly uncertain yet drives critical estimates of carbon emissions, climate change, and food and bioenergy production. We use new, spatially explicit land availability data in conjunction with a model sensitivity analysis to estimate the effects of additional land protection on land use and land cover. The land availability data include protected land and agricultural suitability and is incorporated into the Moirai land data system for initializing the Global Change Analysis Model. Overall, decreasing land availability is relatively inefficient at preserving undeveloped land while having considerable regional land‐use impacts. Current amounts of protected area have little effect on land and crop production estimates, but including the spatial distribution of unsuitable (i.e., unavailable) land dramatically shifts bioenergy production from high northern latitudes to the rest of the world, compared with uniform availability. This highlights the importance of spatial heterogeneity in understanding and managing land change. Approximately doubling the current protected area to emulate a 30% protected area target may avoid land conversion by 2050 of less than half the newly protected extent while reducing bioenergy feedstock land by 10.4% and cropland and grazed pasture by over 3%. Regional bioenergy land may be reduced (increased) by up to 46% (36%), cropland reduced by up to 61%, pasture reduced by up to 100%, and harvested forest reduced by up to 35%. Only a few regions show notable gains in some undeveloped land types of up to 36%. Half of the regions can reach the target using only unsuitable land, which would minimize impacts on agriculture but may not meet conservation goals. Rather than focusing on an area target, a more robust approach may be to carefully select newly protected land to meet well‐defined conservation goals while minimizing impacts to agriculture.

54 ENVIRONMENTAL SCIENCES↗

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Persistence of bacterial-mediated anti-rotifer protection in preliminary outdoor cultivation trial for Microchloropsis salina

Outdoor algal cultivation systems are susceptible to a wide variety of deleterious species. In previously published studies, we observed protection using microbial consortia at laboratory scale cultures; Microchloropsis salina in the presence of microbial consortia were protected from grazing from the marine rotifer, Brachionus plicatilis. Our objective for the present work was to determine if this protection conferred by microbial consortia in controlled laboratory experiments would persist in an open, outdoor multi-liter cultivation system. We found that algal protection did persist as evidenced by the presence of fewer motile rotifers and decreased rotifer-associated egg counts for the consortia-treated outdoor cultures. Due to the low temperature and light conditions that reduced growth of the algae outdoors, we performed an indoor laboratory assay which also confirmed the persistence of algal protection. Lastly, the lower numbers of motile rotifers and fewer rotifer-associated eggs in the consortia-treated algal cultures suggests a possible protective mechanism by the consortia through interfering with the rotifer lifecycle or reproduction. Finally, these initial results support the possibility that low cost, prophylactic treatments with microbial consortia can protect algae from deleterious species in outdoor cultivation systems.

59 BASIC BIOLOGICAL SCIENCES↗

Superconducting Magnet Power Supply and Hard-Wired Quench Protection at Jefferson Lab for 12 GeV Upgrade

The superconducting magnet system in Hall B being designed and built as part of the Jefferson Lab 12 GeV upgrade requires powering two conduction cooled superconducting magnets - a torus and a solenoid. The torus magnet is designed to operate at 3770 A and solenoid at 2416 A. Failure Modes and Effects Analysis (FMEA) determined that voltage level thresholds and dump switch operation for magnet protection should be tested and analyzed before incorporation into the system. The designs of the quench protection and voltage tap sub-systems were driven by the requirement to use a primary hard-wired quench detection sub-system together with a secondary PLC-based protection. Parallel path voltage taps feed both the primary and secondary quench protection sub-systems. The PLC based secondary protection is deployed as a backup for the hard-wired quench detection sub-system and also acts directly on the dump switch. Here, we describe a series of tests and modifications carried out on the magnet power supply and quench protection system to ensure that the superconducting magnet is protected for all fault scenarios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Explicitly Accounting for Protected Lands within the GCAM 3.0

The Global Change Assessment Model Version 3.0 defines three different levels of “Protected Lands” within the agricultural and landuse component. These three different scenarios effectively cordon off 3.5% (5.0 million km 2 ) of the Earth’s terrestrial lands in the de minimus Protected Land Scenario, 5.0% (7.20 million km 2 ) in the Core Protected Land Scenario, and 8.2% (11.8 million km 2 ) in the Expanded Protected Land Scenario. None of these scenarios represents the “right” level of Protected Lands for the planet today or tomorrow. Rather, the goal is to create a range of scenarios that can be used in modeling human responses to climate change and the impact those would have on managed and unmanaged terrestrial lands. These scenarios harness the wealth of information in the United Nations Environment Programme World Conservation Monitoring Centre’s World Database on Protected Areas and its categories of explicit degrees of protection.

54 ENVIRONMENTAL SCIENCES↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Locating, Prediction and Protection (FLPPS)

One of the main objectives of this DOE-sponsored project was to reduce customer outage time. Fault location, prediction, and protection are the most important aspects of fault management for the reduction of outage time. In the past most of the research and development on power system faults in these areas has focused on transmission systems, and it is not until recently with deregulation and competition that research on power system faults has begun to focus on the unique aspects of distribution systems. This project was planned with three Phases, approximately one year per phase. The first phase of the project involved an assessment of the state-of-the-art in fault location, prediction, and detection as well as the design, lab testing, and field installation of the advanced protection system on the SCE Circuit of the Future located north of San Bernardino, CA. The new feeder automation scheme, with vacuum fault interrupters, will limit the number of customers affected by the fault. Depending on the fault location, the substation breaker might not even trip. Through the use of fast communications (fiber) the fault locations can be determined and the proper fault interrupting switches opened automatically. With knowledge of circuit loadings at the time of the fault, ties to other circuits can be closed automatically to restore all customers except the faulted section. This new automation scheme limits outage time and increases reliability for customers. The second phase of the project involved the selection, modeling, testing and installation of a fault current limiter on the Circuit of the Future. While this project did not pay for the installation and testing of the fault current limiter, it did perform the evaluation of the fault current limiter and its impacts on the protection system of the Circuit of the Future. After investigation of several fault current limiters, the Zenergy superconducting, saturable core fault current limiter was selected for installation. Because of some testing problems with the Zenergy fault current limiter, installation was delayed until early 2009 with it being put into operation on March 6, 2009. A malfunction of the FCL controller caused the DC power supply to the superconducting magnet to be turned off. This inserted the FCL impedance into the circuit while it was in normal operation causing a voltage resonance condition. While these voltages never reached a point where damage would occur on customer equipment, steps were taken to insure this would not happen again. The FCL was reenergized with load on December 18, 2009. A fault was experienced on the circuit with the FCL in operation on January 14, 2010. The FCL operated properly and reduced the fault current by about 8%, what was expected from tests and modeling. As of the end of the project, the FCL was still in operation on the circuit. The third phase of the project involved the exploration of several advanced protection ideas that might be at a state where they could be applied to the Circuit of the Future and elsewhere in the SCE electrical system. Based on the work done as part of the literature review and survey, as well as a number of internal meetings with engineering staff at SCE, a number of ideas were compiled. These ideas were then evaluated for applicability and ability to be applied on the Circuit of the Future in the time remaining for the project. Some of these basic ideas were implemented on the circuit including measurement of power quality before and after the FCL. It was also decided that we would take what was learned as part of the Circuit of the Future work and extend it to the next generation circuit protection for SCE. Also at this time, SCE put in a proposal to the DOE for the Irvine Smart Grid Demonstration using ARRA funding. SCE was successful in obtaining funding for this proposal, so it was felt that exploration of new protection schemes for this Irvine Smart Grid Demonstration would be a good use of the project resources. With this in mind, a protection system that uses fault interrupting switches, high speed communications, and looping two radial distribution circuits would have the potential for significant reductions in interruption time and number of interruptions for customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Systems of Radiological Protection for Ionizing and Non-Ionizing Radiation

This paper summarizes the presentations and panel discussion held at Plenary Session 1 of the 16th IRPA International Congress/69th Health Physics Society Annual Meeting, in Orlando, FL, in July 2024. Plenary Session 1 discussed the basics of the systems of radiological protection (RP) for ionizing radiation (IR) and non-ionizing radiation (NIR) and included five presentations and a panel discussion. Rodney Croft, Chair of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), delivered the first presentation. Croft introduced the System of RP for NIR and provided an overview of ICNIRP’s coverage and current areas of work. Werner Rühm, Chair of the International Commission on Radiological Protection (ICRP), delivered the second presentation. He gave an overview of the System of RP for IR and covered the key principles of justification, optimization, and dose limitation, including the current plans of ICRP toward the envisaged revision of the System of RP. The third speaker, Sigurður Magnús Magnússon, from the International Radiation Protection Association (IRPA), provided the perspective of the RP professionals on the development of the Systems of RP for IR and NIR. Emilie van Deventer, from the World Health Organization (WHO), presented WHO’s views of both Systems of RP and discussed the relevant current activities of WHO with regard to IR and NIR. Kathryn Higley, President of the National Council on Radiation Protection and Measurements (NCRP), delivered the final presentation. Higley outlined the history of NCRP, the differences between ICRP and NCRP, and discussed the role of the NCRP in the System of RP, including NCRP’s role to analyze mechanisms of interaction of NIR with biological systems, including humans. The session concluded with a fruitful panel discussion, where the audience had the opportunity to ask the five invited speakers questions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bacterial communities protect the alga Microchloropsis salina from grazing by the rotifer Brachionus plicatilis

Open algal ponds are likely to succumb to unpredictable, devastating crashes by one or several deleterious species. Developing methodology to mitigate or prevent pond crashes will increase algal biomass production, drive down costs for algae farmers, and reduce the risk involved with algae cultivation, making it more favorable for investment by entrepreneurs and biotechnology companies. In this work, we postulate that specific algal-bacterial co-cultures grown with the green alga Microchloropsis salina prevented grazing by the marine rotifer, Brachionus plicatilis. We obtained seven algal-bacterial co-cultures from crashed rotifer cultures, maintained them in co-culture with Microchloropsis salina , and used a microalgal survival assay to determine that algae present in each co-culture were protected from rotifer grazing and culture crash. After months of routinely diluting and maintaining these seven algal-bacterial co-cultures, we repeated the assay and found the opposite result: none of the seven bacterial communities protected the microalgae from rotifer grazing. We performed 16S rRNA gene amplicon sequencing on the protective and nonprotective co-culture samples and identified substantial differences in the makeup of the bacterial communities. Protective bacterial communities consisted primarily of Alphaproteobacteria (Rhodobacteraceae) and Gammaproteobacteria ( Marinobacter , Pseudomonas, Methylophaga ) while nonprotective bacterial communities were less diverse and missing many putatively crucial members. We compared the seven protective communities with the seven nonprotective communities and we correlated specific bacterial amplicon sequence variants with algal protection. With these data, our future research will aim to define and develop an engineered-microbiome that can stabilize industrial Microchloropsis salina cultures by protecting against grazer-induced pond crashes.

59 BASIC BIOLOGICAL SCIENCES↗

Protective effect of vitreous against hemoglobin neurotoxicity

Highlights: • Bovine vitreous protected cultured neurons from the oxidative toxicity of hemoglobin. • Complete neuroprotection was provided by a 3% vitreous solution. • Ascorbate accounted for most protection in diluted vitreous. • Transferrin and selenium content may contribute in undiluted vitreous. • Vitreous may protect adjacent neurons from hemorrhagic injury. Hemorrhage into the brain parenchyma or subarachnoid space is associated with edema and vascular injury that is likely mediated at least in part by the toxicity of hemoglobin. In contrast, extravascular blood appears to be less neurotoxic when localized to the retina or adjacent vitreous, the gel filling the posterior segment of the eye. In this study, the hypothesis that vitreous protects neurons from hemoglobin toxicity was investigated in a primary cortical cell culture model. Consistent with prior observations, hemoglobin exposure for 24 h resulted in death of most neurons without injury to co-cultured glia. Neuronal loss was reduced in a concentration-dependent fashion by bovine vitreous, with complete protection produced by 3% vitreous solutions. This effect was associated with a reduction in malondialdehyde but an increase in cell iron. At low vitreous concentrations, its ascorbate content was sufficient to account for most neuroprotection, as equivalent concentrations of ascorbate alone had a similar effect. However, other vitreous antioxidants provided significant protection when applied at concentrations present in undiluted vitreous, and prevented all neuronal loss when combined in the absence of ascorbate. These results indicate that vitreous is an antioxidant cocktail that robustly protects neurons from hemoglobin toxicity, and may contribute to the relative resistance of retinal neurons to hemorrhagic injury.

60 APPLIED LIFE SCIENCES↗

Protective effect of zinc supplementation against cadmium-induced oxidative stress and the RANK/RANKL/OPG system imbalance in the bone tissue of rats

It was investigated whether protective influence of zinc (Zn) against cadmium (Cd)-induced disorders in bone metabolism may be related to its antioxidative properties and impact on the receptor activator of nuclear factor (NF)-κΒ (RANK)/RANK ligand (RANKL)/osteoprotegerin (OPG) system. Numerous indices of oxidative/antioxidative status, and Cd and Zn were determined in the distal femur of the rats administered Zn (30 and 60 mg/l) or/and Cd (5 and 50 mg/l) for 6 months. Soluble RANKL (sRANKL) and OPG were measured in the bone and serum. Zn supplementation importantly protected from Cd-induced oxidative stress preventing protein, DNA, and lipid oxidation in the bone. Moreover, Zn protected from the Cd-induced increase in sRANKL concentration and the sRANKL/OPG ratio, and decrease in OPG concentration in the bone and serum. Numerous correlations were noted between indices of the oxidative/antioxidative bone status, concentrations of sRANKL and OPG in the bone and serum, as well as the bone concentrations of Zn and Cd, and previously reported by us in these animals (Brzóska et al., 2007) indices of bone turnover and bone mineral density. The results allow us to conclude that the ability of Zn to prevent from oxidative stress and the RANK/RANKL/OPG system imbalance may be implicated in the mechanisms of its protective impact against Cd-induced bone damage. This paper is the first report from an in vivo study providing evidence that beneficial Zn impact on the skeleton under exposure to Cd is related to the improvement of the bone tissue oxidative/antioxidative status and mediating the RANK/RANKL/OPG system. - Highlights: • Cd induces oxidative stress in the bone tissue. • Cd disturbs bone metabolism via disorder of the RANK/RANKL/OPG system balance. • Zn supplementation protects from Cd-induced oxidative stress in the bone tissue. • Zn protects from the RANK/RANKL/OPG system imbalance caused by Cd in the bone tissue. • Enhanced Zn intake protects from Cd-induced disorders in bone metabolism.

60 APPLIED LIFE SCIENCES↗

Sildenafil protects against bile duct ligation induced hepatic fibrosis in rats: Potential role for silent information regulator 1 (SIRT1)

Hepatic fibrosis is a potential health problem that may end with life-threatening cirrhosis and primary liver cancer. Recent studies point out to the protective effects of silent information regulator1 (SIRT1), against different models of organs fibrosis. This work aimed to investigate the possible protective effect of sildenafil (SIRT1 activator) against hepatic fibrosis induced by bile duct ligation (BDL). Firstly, three different doses of sildenafil (5, 10, 20 mg/kg/day) were investigated; to detect the most protective one against BDL induced liver dysfunction and hepatic fibrosis. The most protective dose is then used; to study its effect on BDL induced SIRT1 downregulation, imbalance of oxidant/antioxidant status, increased inflammatory cytokines and fibrosis. Sildenafil (20 mg/kg/day) was the most protective one, it caused upregulation of SIRT1, reduction of hepatic malondialdehyde (MDA) content, increase in expression of nuclear factor erythroid 2-related factor 2 (Nrf2), hemeoxygenease (HO)-1, reduced glutathione (GSH) content and superoxide dismutase (SOD) activity. Hepatic content of tumor necrosis factor-α (TNF-α) and nuclear factor κB (NFκB) expression & content displayed significant reductions with sildenafil treatment, Furthermore, sildenafil caused marked reductions of transforming growth factor (TGF)-β content, expression of plasminogen activator inhibitor-1 (PAI-1), matrix metalloproteinase-9 (MMP-9), tissue inhibitor of metalloproteinase-1 (TIMP-1), α-smooth muscle actin (α-SMA), fibronectin, collagen I (α1) and hydroxyproline content. However, sildenafil protective effects were significantly reduced by co-administration of EX527 (SIRT1 inhibitor). Our work showed, for the first time that, sildenafil has promising protective effects against BDL induced liver dysfunction and hepatic fibrosis. These effects may be, in part, mediated by up regulation of SIRT1. - Highlights: • Bile duct ligation induced hepatic fibrosis associated with down regulation of SIRT1. • Sildenafil reduced hepatic fibrosis induced by bile duct ligation. • Sildenafil upregulated SIRT1 in the liver after bile duct ligation. • EX527, SIRT1 inhibitor, reduced sildenafil hepatoprotective effects. • Sildenafil hepatoprotective effects are SIRT1 dependent.

60 APPLIED LIFE SCIENCES↗

THE INFLUENCE OF THERMAL EVOLUTION IN THE MAGNETIC PROTECTION OF TERRESTRIAL PLANETS

Magnetic protection of potentially habitable planets plays a central role in determining their actual habitability and/or the chances of detecting atmospheric biosignatures. Here we develop a thermal evolution model of potentially habitable Earth-like planets and super-Earths (SEs). Using up-to-date dynamo-scaling laws, we predict the properties of core dynamo magnetic fields and study the influence of thermal evolution on their properties. The level of magnetic protection of tidally locked and unlocked planets is estimated by combining simplified models of the planetary magnetosphere and a phenomenological description of the stellar wind. Thermal evolution introduces a strong dependence of magnetic protection on planetary mass and rotation rate. Tidally locked terrestrial planets with an Earth-like composition would have early dayside magnetopause distances between 1.5 and 4.0 R{sub p} , larger than previously estimated. Unlocked planets with periods of rotation {approx}1 day are protected by magnetospheres extending between 3 and 8 R{sub p} . Our results are robust in comparison with variations in planetary bulk composition and uncertainties in other critical model parameters. For illustration purposes, the thermal evolution and magnetic protection of the potentially habitable SEs GL 581d, GJ 667Cc, and HD 40307g were also studied. Assuming an Earth-like composition, we found that the dynamos of these planets are already extinct or close to being shut down. While GL 581d is the best protected, the protection of HD 40307g cannot be reliably estimated. GJ 667Cc, even under optimistic conditions, seems to be severely exposed to the stellar wind, and, under the conditions of our model, has probably suffered massive atmospheric losses.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Building-Level Motor Protection on Power System Transient Behaviors

Transmission and distribution system level protection strategies have been extensively investigated to advise better coordination of physical protection devices. A diversity of functional motors with dedicated protection schemes are popularized in increasing number of commercial, residential and industrial buildings. This paper focuses on implementing several most popular protection schemes on Eletro-Magnetic Transient Program (EMTP) simulation for three-phase and single-phase induction motors that exist in commercial buildings connected to typical distribution feeders. Voltage depressions are played in at the head of the feeder fully loaded with functional induction motors to investigate the behaviors of single-phase motor stalling, the action of motor protection and reconnection, and the impacts of device-level protection on system-level dynamics. Several distribution feeders are represented in standard IEEE 39-bus transmission system to simulate fault-induced delayed voltage recovery (FIDVR) and explore mitigation strategies by optimally configuring the building-level motor protection settings.

Liu, Yuan↗

Aggregate Protection Response of Motor Loads in Commercial Buildings

Protection plays a critical role in determining the dynamic response of the induction motor loads and the overall performance of composite load models when subjected to voltage sags or disturbances. Up to date, due to lack of understanding of the aggregate performance of the protection of motors, protection modeling of the motors becomes one of the least accurate parts in dynamic (composite) load models. This paper fills this gap by providing detailed analysis of the motor loads and their associated protection in commercial buildings and deriving the aggregate protection response based on integrated transmission and distribution dynamic co-simulation. The results showed that the aggregate protection response of motor loads varies significantly among different classes, which indicates the protection modeling that has been developed based on the assumption of similar or even identical responses and used in some composite load models need to be updated.

Huang, Qiuhua↗

National variability in Americans’ COVID-19 protective behaviors: Implications for vaccine roll-out

Protective behaviors such as mask wearing and physical distancing are critical to slow the spread of COVID-19, even in the context of vaccine scale-up. Understanding the variation in self-reported COVID-19 protective behaviors is critical to developing public health messaging. The purpose of the study is to provide nationally representative estimates of five self-reported COVID-19 protective behaviors and correlates of such behaviors. In this cross-sectional survey study of US adults, surveys were administered via internet and telephone. Adults were surveyed from April 30-May 4, 2020, a time of peaking COVID-19 incidence within the US. Participants were recruited from the probability-based AmeriSpeak® national panel. Brief surveys were completed by 994 adults, with 73.0% of respondents reported mask wearing, 82.7% reported physical distancing, 75.1% reported crowd avoidance, 89.8% reported increased hand-washing, and 7.7% reported having prior COVID-19 testing. Multivariate analysis (p critical value .05) indicates that women were more likely to report protective behaviors than men, as were those over age 60. Respondents who self-identified as having low incomes, histories of criminal justice involvement, and Republican Party affiliation, were less likely to report four protective behaviors, though Republicans and individuals with criminal justice histories were more likely to report having received COVID-19 testing. The majority of Americans engaged in COVID-19 protective behaviors, with low-income Americans, those with histories of criminal justice involvement, and self-identified Republicans less likely to engage in these preventive behaviors. Culturally competent public health messaging and interventions might focus on these latter groups to prevent future infections. These findings will remain highly relevant even with vaccines widely available, given the complementarities between vaccines and protective behaviors, as well as the many challenges in delivering vaccines.

60 APPLIED LIFE SCIENCES↗

A Risk-Informed Performance-Based Methodology to Manage Fire Protection Systems in Nuclear Facilities

Fire protection systems (FPSs) and features are installed in U.S. Department of Energy (DOE) Hazard Category 1, 2, or 3 nuclear facilities to protect property (maximum possible fire loss thresholds), life, and nuclear safety (i.e., structures, systems, and components). These FPSs and features are designed and maintained in accordance with the prescriptive guidance provided in applicable building codes and National Fire Protection Association codes and standards. Management, operations, and maintenance activities of FPSs involve significant effort. A DOE facility’s documented safety analysis or other safety basis document could also rely on FPSs to provide either a safety significant or safety class function to mitigate fire hazards and minimize radiological consequences. In some cases, the designation of safety significant or safety class may be determined to provide a layer of defense-in-depth to minimize nuclear safety risks independent of the fire risk. DOE standards allow the use of performance-based design alternatives developed by the fire industry but do not consider the defense-in-depth layers of protection provided in DOE facilities to prevent or mitigate the risks associated with unintended release of radioactive materials into the environment. Pacific Northwest National Laboratory developed a decision-making methodology tailored for DOE non-reactor nuclear facilities to manage FPSs and features by integrating nuclear safety risk insights into a performance-based analysis. This risk-informed, performance-based (RIPB) methodology can be used to provide the technical basis for classifying an FPS as safety class and safety significant, tailoring administrative controls (e.g., technical safety requirements), and ranking the importance of FPSs to prioritize maintenance, upgrades, and replacement activities. The RIPB methodology is a graded approach to inform DOE facility owners and Fire Protection Program managers of the most risk-significant FPSs and equipment, and those systems would be cost-beneficial to relax rigor if there is a need to re-design the FPS coverage or deviate from DOE and National Fire Protection Association standards for those systems that would be less significant. This paper describes the framework used to develop the RIPB methodology and the outcome of implementing this methodology in a use-case nuclear facility. This paper also discusses the impact to DOE policies and standards and the safety margins and defense-in-depth measures credited in nuclear safety assessments in a facility’s documented safety analysis and the benefits of implementing an RIPB methodology in lieu of a prescriptive method to comply with fire protection requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗