Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSMISSION LINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

reVRt (reV Routing) [SWR-25-112]

The reV Routing (reVRt) tool is a computational framework for modeling and optimizing transmission infrastructure requirements for electrical grid connections. By employing a spatially-aware least-cost-path methodology, it allows users to incorporate a wide range of factors including siting constraints, regional component costs, land composition costs, point-of-interconnection costs, and network upgrade costs. Additionally, the tool enables advanced follow-on analyses, such as land characterization for potential transmission line routes, to support informed decision-making. Although it's designed to integrate seamlessly with the reV model, the reV Routing tool is versatile and can also be utilized independently for standalone analyses in transmission planning and resource assessment scenarios.

Pinchuk, Pavlo (Paul) [National Renewable Energy L↗

Decision support for United States—Canada energy integration is impaired by fragmentary environmental and electricity system modeling capacity

The renewable energy transition is leading to increased electricity trade between the United States and Canada, with Canadian hydropower providing firm lower-carbon power and buffering variability of wind and solar generation in the U.S. However, long-term power purchase agreements and transborder transmission projects are controversial, with two of four proposed transmission lines between Quebec, Canada and the northeast U.S. cancelled since 2018. Here, we argue that controversies are exacerbated by a lack of open-source data and tools to understand tradeoffs of new hydropower generation and transmission infrastructure in comparison to alternatives. This gap includes impacts that incremental transmission and generation projects have on the economics of the entire system, for example, how new transmission projects affect exports to existing markets or incentivize new generation. We identify priority areas for data synthesis and model development, such as integrating linked hydropower and hydrologic interactions in energy system models and openly releasing (by utilities) or back-calculating (by researchers) hydropower generation and operational parameters. Publicly available environmental (e.g. streamflow, precipitation) and techno-economic (e.g. costs, reservoir size,) data can be used to parameterize freely usable and extensible models. Existing models have been calibrated with operational data from Canadian utilities that are not publicly available, limiting the range of scientific and commercial questions these tools have been used to answer and the range of parties that have been involved. Studies conducted using highly resolved, national-scale public data exist in other countries, notably, the United States, and demonstrate how greater transparency and extensibility can drive industry action. Improved data availability in Canada could facilitate approaches that (1) increase participation in decarbonization planning by a broader range of actors; (2) allow independent characterizations of environmental, health, and economic outcomes of interest to the public; and (3) identify decarbonization pathways consistent with community values.

13 HYDRO ENERGY↗

Geothermal Fault Zone and Fluid Imaging through Joint Airborne ZTEM and Ground MT Data Inversion Analysis

This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.

15 GEOTHERMAL ENERGY↗

2020 International Conference on Smart Grids and Energy Systems (SGES)

This paper is concerned about phasor-based linear state estimation of three-phase power grids which contain non transposed lines and unsymmetrical branches. It builds upon our previous work where the linear measurement equations were decoupled into three independent sets via the symmetrical component transformation. Such a transformation may however not fully decouple the measurement equations if there are nontransposed transmission lines and unsymmetrical branches in the system. This paper addresses this limitation by deriving additive terms that compensate for the remaining coupling between sequence measurements after the application of the conventional transformation. It will be shown that general unbalanced threephase power grids can still be transformed into three decoupled subsystems and their state estimation solution can be obtained in parallel by the proposed approach.

Khalili, Ramtin↗

Assessing the Reliability Benefits of Energy Storage as a Transmission Asset

Utilizing energy storage solutions to reduce the need for traditional transmission investments has been recognized by system planners and supported by federal policies in recent years. This work demonstrates the need for detailed reliability assessment for quantitative comparison of the reliability benefits of energy storage and traditional transmission investments. First, a mixed-integer linear programming expansion planning model considering candidate transmission lines and storage technologies is solved to find the least-cost investment decisions. Next, operations under the resulting system configuration are simulated in a probabilistic reliability assessment which accounts for weather-dependent forced outages. The outcome of this work, when applied to TPPs, is to further equalize the consideration of energy storage compared to traditional transmission assets by capturing the value of storage for system reliability.

co-optimization↗

Systems and methods for controlling electrical grid resources

The present invention relates to PMU-based control systems for dampening inter-area oscillations in large-scale interconnected power systems or grids to protect against a catastrophic blackout. The control systems receive phasor measurements from two or more locations on an AC transmission line and generates a power control command to a power resource on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a finline antenna for current drive in TST-2

A novel “finline” antenna was designed to excite lower-hybrid waves (LHWs) for plasma current drive at 2.45 GHz in the TST-2 spherical tokamak. A periodic fin array acts as a transmission line for electromagnetic surface waves. Cold tests confirmed propagation of the electromagnetic surface wave on the fin array which was dominantly Transverse Magnetic (TM). Unlike the conventional waveguide array “grill” antenna, the finline antenna requires only two ports to feed all the elements, and calculations show that there is little reflection regardless of the plasma conditions in front of the antenna. Characteristics of the microwave transmission on the fin array were investigated using a three-dimensional full-wave simulation and the fin geometry was tuned to achieve the desired refractive index. Coupling to LHWs under typical TST-2 scrape-off layer conditions was confirmed by the simulation. Finally, to demonstrate LHW excitation, the finline antenna was energized in the presence of a plasma generated by another 200 MHz LH antenna. The x-ray radiation showed strong enhancement during the finline antenna pulse which indicated successful generation of fast electrons by LHWs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Remote Sensing Approach for Monitoring Tree Health Adjacent to Transmission Corridors

This study presents an initial proof-of-concept for a satellite-based remote sensing approach to identify and monitor potential areas of poor tree health across the entire BPA service territory on an annual basis. We tested three variants of “delta peak NDVI” ( ΔPN ) change detection metrics that express interannual variation in primary productivity relative to a baseline by comparing ΔPN values for known insect/disease disturbances and nearby reference locations. All three metrics showed promise for detecting poor tree health in the year during disturbance, but the metric based on the difference from the long-term (2016-2024) median ( Δ Med PN ) was preferred due to its responsiveness to change in the years during and after disturbance, resilience to interannual variation, and ease of interpretation as being above or below normal. Comparison of Δ Med PN grouped by relative severity of disturbance indicated it was not sensitive enough to detect “low” severity disturbances, as mapped by USGS’s LANDFIRE program, but could distinguish “moderate” and “high” severity disturbances from reference locations. These findings informed selection of a threshold for Δ Med PN , which was combined with areas exhibiting negative NDVI to map potential areas of concern. Visual inspection of before/after high-resolution imagery and NDVI time series showed that many areas of concern aligned with visible signs of defoliation and die-off as well as other types of disturbance (e.g., landslides, logging, road grading, flooding). Some areas of concern are thought to be false detections caused by persistent shadow, and some could not be explained with visual inspection due to spatiotemporal limitations of before/after imagery. In summary, our approach shows promise for large-scale monitoring of tree health adjacent to BPA transmission lines, but additional work is recommended to improve model sophistication and remove noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Profiles of E1 EMP Coupling to Single Conductors

An electro-magnetic pulse (EMP) event can induce large currents and voltages on electrical conductors such as electrical power transmission lines which span many kilometers and the shorter lines typically tens of meters in length used to monitor equipment controlling the power grid. The exact current and voltage induced on a conductor depends on many factors, such as line height, diameter and length as well as ground conductivity and the location of the EMP event relative to the conductor. The current work focus on the line location and orientation relative to the EMP source. A statistical, Monte-Carlo approach is used in sampling the line configuration and then calculating the induced current and voltage. Thousands of EMP events are simulated on the region of the Earth where the EMP event can couple to a given above-ground conductor and the resulting current and voltage is then calculated on that conductor. Through the many simulations, one can assemble statistics on the insult including the peak value, rise time and pulse width.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Stage and Multi-Timescale Robust Co-Optimization Planning for Reliable and Sustainable Power Systems. Final Report

In this project, Clarkson University, in collaboration with Southern Methodist University and University of Pittsburgh, conducted the research to model, design, and implement a sophisticated generation and transmission co-optimization planning decision tool, called Multi-stage and Multi-timescale robust Co-Optimization Planning (MMCOP). The MMCOP decision tool intends to facilitate generation and transmission co-optimization planning of emerging power systems, while mitigating risks and uncertainties in both short-term operation dynamics and long-term policy and technology changes. Long-term power system planning aims at optimizing asset utilization by investing in a proper mix of various generation technologies and transmission lines to supply the future load growth. In particular, the Clean Power Plan (CPP), which is designed to combat climate change and reduce carbon emissions by setting a national limit on carbon pollution from power plants, may dramatically change the landscape of the power industry by further promoting clean energy and phasing out emissions-intensive generation technologies. In addition, novel non-wire alternatives (e.g., demand response (DR), distributed generation (DG), energy efficiency (EE), and smart grid technologies) and the computational complexity for large-scale systems significantly complicate the system planning procedure even further. However, existing conventional planning approaches neglect short-term variability and uncertainty of renewable energy, hourly chronological operation details, and physical nonlinear characteristics of the alternating current transmission network. As a result, existing conventional planning approaches may not work properly, and power systems reliability could be in jeopardy. In observing the limitations of existing conventional planning approaches and addressing new challenges of emerging power systems, the main scope of this project to develop co-optimization planning models within a multi-stage and multi-timescale framework. In particular, random contingencies, key uncertainty factors, and AC power flows are included to derive expansion plans while considering both long-term reliability and short-term flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Substation Cable Layouts for EMP Coupling Analysis

Direct coupling of early-time high-altitude electromagnetic pulse (HEMP) to substation control cables is simulated for cable layouts based on surveys of seven electrical substations in the United States. An analytic transmission line modeling code is used to estimate worst-case coupled current at the terminations of cable segments in or near the control shack. Where applicable, an induced voltage due to cable shield grounding is also estimated. Various configurations are simulated, including cables with different elevations, lengths, radii, and terminations. Plots of the coupled HEMP effects are given, and general relationships between these effects and the substations geometric and material parameters are highlighted and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Machine Learning-Based Vulnerability Analysis for Cascading Failures of Integrated Power-Gas Systems

This article proposes a cascading failure simulation (CFS) method and a hybrid machine learning method for vulnerability analysis of integrated power-gas systems (IPGSs). The CFS method is designed to study the propagating process of cascading failures between the two systems, generating data for machine learning with initial states randomly sampled. The proposed method considers generator and gas well ramping, transmission line and gas pipeline tripping, island issue handling and load shedding strategies. Then, a hybrid machine learning model with a combined random forest (RF) classification and regression algorithms is proposed to investigate the impact of random initial states on the vulnerability metrics of IPGSs. Extensive case studies are carried out on three test IPGSs to verify the proposed models and algorithms. Simulation results show that the proposed models and algorithms can achieve high accuracy for the vulnerability analysis of IPGSs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Electrolysis Systems Into Isolated Microgrid Systems at Extreme Cold Climates

Isolated microgrid systems are generally used to power communities in remote locations where transmission line installations are cost prohibitive. These systems are usually powered by diesel generators, delivering expensive energy with high carbon emissions. However, most of these communities have special geographic access to renewable energy. These special conditions make it interesting to investigate the deployment of renewable energies and storage solutions. Within this scope, this paper analyses the integration of water electrolysis systems into off-grid communities, simulating the electrolyzer as well as the whole electrical grid in real time.

digital real-time simulation↗

Blackstart of Power Grids with Inverter-Based Resources

This paper presents the findings of our investigation into inverter-based resource-(IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Long-run Marginal Emission Rates for Electricity - Workbooks for 2023 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States' electric sector. A LRMER is an estimate of the rate of emissions that would be either induced or avoided by a change in electric demand, taking into account how the change could influence both the operation as well as the structure of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). These workbooks provide data for 18 GEA regions covering the contiguous United States. Mappings of these regions to ZIP codes and counties is given in this workbook in the corresponding tabs. For more data underlying these emissions factors, see the Cambium 2023 project at https://scenarioviewer.nrel.gov/. For more details on input assumptions and methodology see the associated report (Cambium 2023 Scenario Descriptions and Documentation, https://www.nrel.gov/docs/fy24osti/88507.pdf). Users are advised to review section 4 of the report, which discusses limitations and caveats of the data. This data is planned to be updated annually. Information on the latest versions can be found at https://www.nrel.gov/analysis/cambium.html.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗