Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tabletop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Enhanced Isomer Population via Direct Irradiation of Solid-Density Targets Using a Compact Laser-Plasma Accelerator

Excitation of long-lived states in bromine nuclei using a tabletop laser-plasma accelerator providing pulsed (<100 fs) electron beams provided a sensitive probe of γ strength and level densities in the nuclear quasicontinuum and may indicate angular momentum coupling through electron-nuclear interactions. Solid-density active $LaBr_{3}$ targets absorb real and virtual photons up to 35 ± 2.5 MeV and deexcite through γ cascade into different states. Here, a factor of 4.354 ± 0.932 enhancement of the $^{80}Br^{m}/^{80}Br^{g}$ isomeric ratio was observed following electron irradiation, as compared to bremsstrahlung. Additional angular momentum transfer could possibly occur through nuclear-plasma or electron-nuclear interactions enabled by the ultrashort electron beam. Further investigation of these mechanisms could have far-reaching impact including decreased storage of long-term nuclear waste and an improved understanding of heavy element formation in astrophysical settings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural transformation of dusty plasma crystal in dc discharge plasma by changing confinement ring bias

We report an experimental study of the structural transition of a stable complex plasma crystal to a solid-liquid phase coexistence by the controlled adjustment of the confinement potential, while keeping all other parameters constant. The experiments are carried out on a tabletop linear dusty plasma experimental device, which consists of a circular powered electrode and an extended grounded cathode plate. A stationary crystal of melamine formaldehyde particles is formed in a background of argon plasma inside a confining ring that is isolated from the cathode by a ceramic cover. The stable crystal structure breaks in the core region and transitions to a coexistent state by carefully changing the confining potential, thereby modifying the sheath structure. The transition is confirmed by evaluating the variation in different characteristic parameters such as the pair correlation function, local bond order parameter, and dust kinetic temperature as a function of confining bias potential. It is found that melting in the core is due to the onset of dust fluctuations in the layers beneath the topmost layer, which grow in amplitude as the confining bias potential is reduced below a threshold value. The present technique of changing confinement provides a unique feature to study structural transitions of plasma crystals without affecting the overall plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging the dynamics of initial laser-driven shocks and blowoff plasmas in polystyrene under laser-direct-drive fusion conditions

The dynamics of laser-driven shock propagation in solid ablator material, along with the concomitant processes of shinethrough and blowoff plasma plume expansion, at conditions relevant to laser-direct-drive fusion are measured using a tabletop system capable of supporting rapid dataset development with significantly higher resolution compared to existing methods. The experimental results are directly compared with current radiation-hydrodynamic simulations using the two-dimensional code . Discrepancies between experiments and simulations are evidenced and attributed to limitation of simulation to account for important processes involved in the solid-to-plasma transition. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dielectric laser accelerators

The use of infrared lasers to power optical-scale lithographically fabricated particle accelerators is a developing area of research that has garnered increasing interest in recent years. In this work, the physics and technology of this approach is reviewed, which is referred to as dielectric laser acceleration (DLA). In the DLA scheme operating at typical laser pulse lengths of 0.1 to 1 ps, the laser damage fluences for robust dielectric materials correspond to peak surface electric fields in the GV/m regime. The corresponding accelerating field enhancement represents a potential reduction in active length of the accelerator between 1 and 2 orders of magnitude. Power sources for DLA-based accelerators (lasers) are less costly than microwave sources (klystrons) for equivalent average power levels due to wider availability and private sector investment. Because of the high laser-to-particle coupling efficiency, required pulse energies are consistent with tabletop microJoule class lasers. Combined with the very high (MHz) repetition rates these lasers can provide, the DLA approach appears promising for a variety of applications, including future high-energy physics colliders, compact light sources, and portable medical scanners and radiative therapy machines.

43 PARTICLE ACCELERATORS↗

Design and development of a portable flash X-ray source driven by battery powered compact Marx generator

The design, construction and operational characteristics of a portable flash X-ray source driven by battery-powered compact Marx is reported. The novel configuration of compact Marx utilizes hollow capacitors in successive stages to enhance the erection reliability. The characteristic impedance of this system is ∼ 200 Ω. At discharge of ∼ 22 kV, >200 kV output pulse of 60 ns duration (FWHM) with rise time of <5 ns (10% - 90%) is produced. The pulser requires Nitrogen gas pressurization up to 3 atm for operation at maximum rating. The Marx generator assembly is fitted in to a stainless steel tube of 10 cm diameter and 1.2 m length. While using a demountable sealed X-ray tube of matched impedance, this device produces an X-ray pulse of approximately ∼ 30 ns duration and has maximum energy of ∼ 200 keV. This true tabletop device is able to produce dose up to 100 mR per shot, measured at the distance of 30 cm from output window. The focal spot size has been passively confirmed to be in the sub-millimeter (<1 mm) range. (author)

43 PARTICLE ACCELERATORS↗

Characterization of Quantum Frequency Processors

Frequency-bin qubits possess unique synergies with wavelength-multiplexed lightwave communications, suggesting valuable opportunities for quantum networking with the existing fiber-optic infrastructure. Although the coherent manipulation of frequency-bin states requires highly controllable multi-spectral-mode interference, the quantum frequency processor (QFP) provides a scalable path for gate synthesis leveraging standard telecom components. Here, we summarize the state of the art in experimental QFP characterization. Distinguishing between physically motivated “open box” approaches that treat the QFP as a multiport interferometer, and “black box” approaches that view the QFP as a general quantum operation, we highlight the assumptions and results of multiple techniques, including quantum process tomography of a tunable beamsplitter—to our knowledge the first full process tomography of any frequency-bin operation. Our findings should inform future characterization efforts as the QFP increasingly moves beyond proof-of-principle tabletop demonstrations toward integrated devices and deployed quantum networking experiments.

42 ENGINEERING↗

Design of an electro-optical sampling experiment at the AWA facility.

The free space electro-optical (EO) sampling technique is a powerful tool for analyzing the longitudinal charge density of an ultrashort e-beam. In this paper, we present (i) experimental results for a laser-based mock-up of the EO experiment [1] and (ii) a design for a beam-based, single-shot, EO sampling experiment using the e-beam from the Argonne Wakefield Accelerator (AWA) RE photoinjector. For the mock-up, a tabletop terahertz experiment is conducted in the AWA laser room. The mock-up uses an IR beam incident on <110> ZnTe crystal to produce a THz pulse via optical rectification. Detection is based on the cross correlation between the THz field and the probe IR laser field in a second <110> ZnTe crystal.

43 PARTICLE ACCELERATORS↗

Detecting Phase-Resolved Magnetization Dynamics by Magneto-Optic Effects at 1550 nm Wavelength

We demonstrate the detection of phase-resolved magnetization dynamics with combinatorial magneto-optic Kerr and Faraday effects. The method uses a continuous-wave laser that is amplitude-modulated at the spin dynamic frequencies, and thus allows for coherent tracking of the spin dynamics, akin a “lock-in” type measurement. In particular, our method, using a single 1550-nmwavelength, probes simultaneously the ferromagnetic resonance of Y 3 Fe 5 O 12 (YIG) and Permalloy (Py = Ni 80 Fe 20 ) in a YIG-Pyhetero structure. The fiber-based magneto-optic components also have the advantage of being made into a compact, tabletop or even portable system with yet robust measurement performances. We believe that our method will be found useful in studying hybrid quantum magnonic systems and/or investigating phase-resolved spin dynamics in nanomagnet structures involving both ferromagnetic insulators and metals.

42 ENGINEERING↗

High-precision monitoring of outgassing species in model extreme ultraviolet photoresists with a cavity ring-down spectrometer

Background Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. Aim Here, we focus on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. Approach The spectrometer’s enhanced laser path length (∼ 20 km) and broadband absorption capabilities in the C–H overtone region allow for sensitive and temporally resolved detection of mixtures of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and post-exposure bake (PEB) as well as storage under varying environmental conditions. Results Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Conclusions Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Extreme ultraviolet photoresists↗

Characterizing degraded visual environments with scanning lenses to improve contrast recovery

Atmospheric aerosols, such as fog and smoke, degrade optical signals via the scattering and absorption of light, making it difficult to recover information from the surrounding environment. Here, we present a technique that measures the angular distribution of light in scattering environments to help recover these degraded optical signals. This is done by passing a collimated beam through the aerosol environment and collecting the scattered and unscattered light with an f-theta scan lens. The lens transforms the angular distribution of the scattered light into the linear domain, mapping the collected light onto a detector. The measured angular scattering distribution is then used to estimate the point spread function of the environment at an arbitrary stand-off distance. This point spread function can be used to deconvolve images blurred by the aerosol environment in which the angular scattering distribution was initially measured. With this approach, we demonstrate improvements in the effective resolution of deblurred images up to 26% over a 120-cm stand-off distance. Experimentation was performed in the Sandia National Laboratories tabletop fog chamber, a platform that generates aerosol environments analogous to real-world fogs. We intend to leverage this technique in future work to develop a low-SWaP system for the in situ characterization of aerosol environments.

Aerosols↗

Characterization of ablator dynamics initiated by picket-pulse conditions

Direct-drive laser-fusion targets may include low-cost plastic ablator material. Here, this work describes a tabletop experimental system designed to enable the investigation of the interaction of such ablator material as a function of the laser wavelength and the associated excitation mechanism. This experimental system offers time-resolved imaging of the material response with subpicosecond temporal resolution and ≈1-μm spatial resolution. The system involves synchronized femtosecond and picosecond lasers to initiate and characterize the dynamics of polystyrene planar targets irradiated by conditions similar to a “picket” prepulse from a direct-drive pulse shape. Ultrafast imaging of the initial excitation process followed by the resulting critical plasma formation, shock-wave propagation, and blowoff plasma expansion is used to compare the impact of excitation wavelength, 355 nm or 266 nm, on the ensuing dynamics. This work aims to investigate fundamental laser material interactions to help advance physics models that can inform the development of laser driver and target designs.

42 ENGINEERING↗

High precision monitoring of outgassing species in model EUV photoresists with a cavity ring-down spectrometer

Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. This study focuses on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. The spectrometer’s enhanced laser path length (~20 km) and broadband absorption capabilities in the CH overtone region allow for sensitive and temporally resolved detection of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and Post-Exposure Bake (PEB) as well as storage under varying environmental conditions. Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Lüttgenau, Bernhard↗

Scatter correction method for x-ray CT using primary modulation: Phantom studies

Purpose: Scatter correction is a major challenge in x-ray imaging using large area detectors. Recently, the authors proposed a promising scatter correction method for x-ray computed tomography (CT) using primary modulation. Proof of concept was previously illustrated by Monte Carlo simulations and physical experiments on a small phantom with a simple geometry. In this work, the authors provide a quantitative evaluation of the primary modulation technique and demonstrate its performance in applications where scatter correction is more challenging. Methods: The authors first analyze the potential errors of the estimated scatter in the primary modulation method. On two tabletop CT systems, the method is investigated using three phantoms: A Catphan(c)600 phantom, an anthropomorphic chest phantom, and the Catphan(c)600 phantom with two annuli. Two different primary modulators are also designed to show the impact of the modulator parameters on the scatter correction efficiency. The first is an aluminum modulator with a weak modulation and a low modulation frequency, and the second is a copper modulator with a strong modulation and a high modulation frequency. Results: On the Catphan(c)600 phantom in the first study, the method reduces the error of the CT number in the selected regions of interest (ROIs) from 371.4 to 21.9 Hounsfield units (HU); the contrast to noise ratio also increases from 10.9 to 19.2. On the anthropomorphic chest phantom in the second study, which represents a more difficult case due to the high scatter signals and object heterogeneity, the method reduces the error of the CT number from 327 to 19 HU in the selected ROIs and from 31.4% to 5.7% on the overall average. The third study is to investigate the impact of object size on the efficiency of our method. The scatter-to-primary ratio estimation error on the Catphan(c)600 phantom without any annulus (20 cm in diameter) is at the level of 0.04, it rises to 0.07 and 0.1 on the phantom with an elliptical annulus (30 cm in the minor axis and 38 cm in the major axis) and with a circular annulus (38 cm in diameter). Conclusions: On the three phantom studies, good scatter correction performance of the proposed method has been demonstrated using both image comparisons and quantitative analysis. The theory and experiments demonstrate that a strong primary modulation that possesses a low transmission factor and a high modulation frequency is preferred for high scatter correction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modulator design for x-ray scatter correction using primary modulation: Material selection

Purpose: An optimal material selection for primary modulator is proposed in order to minimize beam hardening of the modulator in x-ray cone-beam computed tomography (CBCT). Recently, a measurement-based scatter correction method using primary modulation has been developed and experimentally verified. In the practical implementation, beam hardening of the modulator blocker is a limiting factor because it causes inconsistency in the primary signal and therefore degrades the accuracy of scatter correction. Methods: This inconsistency can be purposely assigned to the effective transmission factor of the modulator whose variation as a function of object filtration represents the magnitude of beam hardening of the modulator. In this work, the authors show that the variation reaches a minimum when the K-edge of the modulator material is near the mean energy of the system spectrum. Accordingly, an optimal material selection can be carried out in three steps. First, estimate and evaluate the polychromatic spectrum for a given x-ray system including both source and detector; second, calculate the mean energy of the spectrum and decide the candidate materials whose K-edge energies are near the mean energy; third, select the optimal material from the candidates after considering both the magnitude of beam hardening and the physical and chemical properties. Results: A tabletop x-ray CBCT system operated at 120 kVp is used to validate the material selection method in both simulations and experiments, from which the optimal material for this x-ray system is then chosen. With the transmission factor initially being 0.905 and 0.818, simulations show that erbium provides the least amount of variation as a function of object filtrations (maximum variations are 2.2% and 4.3%, respectively, only one-third of that for copper). With different combinations of aluminum and copper filtrations (simulating a range of object thicknesses), measured overall variations are 2.5%, 1.0%, and 8.6% for 25.4 {mu}m of copper, erbium, and tungsten, respectively. With and without 300 {mu}m of copper in the beam, the measured variations for 25.4 {mu}m of copper, erbium, and tungsten, 1 mm of aluminum, as well as 406 {mu}m of copper, are 1.8%, 0.2%, 5.5%, 1.9%, and 7.5%, respectively. Conclusions: The spatial variation in the effective transmission factor of the modulator blocker due to beam hardening caused by the modulator itself reaches a minimum when the K-edge of the modulator material is near the mean energy of the spectrum. An optimal modulator material selection using the K-edge discontinuity is therefore proposed.

60 APPLIED LIFE SCIENCES↗

Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images

Purpose: Applications of cone-beam CT (CBCT) to image-guided radiation therapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy. Methods: With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as ''free'' prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained. Results: The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan(c)600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of {approx}25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts. Conclusions: By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation.

60 APPLIED LIFE SCIENCES↗

Reference dosimetry for helical tomotherapy: Practical implementation and a multicenter validation

Purpose: The aim of this study was to implement a protocol for reference dosimetry in tomotherapy and to validate the beam output measurements with an independent dosimetry system. Methods: Beam output was measured at the reference depth of 10 cm in water for the following three cases: (1) a 5 x 10 cm{sup 2} static machine specific reference field (MSR), (2) a rotational 5 x 10 cm{sup 2} field without modulation and no tabletop in the beam, (3) a plan class specific reference (PCSR) field defined as a rotational homogeneous dose delivery to a cylindrical shaped target volume: plan with modulation and table-top movement. The formalism for reference dosimetry of small and nonstandard fields [Med.Phys.35: 5179-5186, 2008] and QA recommendations [Med.Phys.37: 4817-4853, 2010] were adopted in the dose measurement protocol. All ionization chamber measurements were verified independently using alanine/EPR dosimetry. As a pilot study, the beam output was measured on tomotherapy Hi-art systems at three other centers and directly compared to the centers specifications and to alanine dosimetry. Results: For the four centers, the mean static output at a depth of 10 cm in water and SAD = 85 cm, measured with an A1SL chamber following the TG-148 report was 6.238 Gy/min {+-} 0.058 (1 SD); the rotational output was 6.255 Gy/min {+-} 0.069 (1 SD). The dose stated by the center was found in good agreement with the measurements of the visiting team: D{sub center}/D{sub visit} = 1.000 {+-} 0.003 (1 SD). The A1SL chamber measurements were all in good agreement with Alanine/EPR dosimetry. Going from the static reference field to the rotational/non modulated field the dose rate remains constant within 0.2% except for one center where a deviation of 1.3% was detected. Conclusions: Following the TG-148 report, beam output measurements in water at the reference depth using a local protocol, as developed at different centers, was verified. The measurements were found in good agreement with alanine/EPR dosimetry. The presented methodology may provide a good concept for reference dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗