Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The science case for an intermediate energy advanced and novel accelerator linear collider facility

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1–100 GV/m, leading to compact acceleration facilities. However, intermediate energy facilities (IEF) are required to test the critical technology elements on the way towards multi-TeV-class colliders. Here a science case for a 20–100 GeV center-of-mass energy ANA-based lepton collider that can be a candidate for an intermediate energy facility is presented. The IEF can provide numerous opportunities for high energy physics studies including precision Quantum Chromodynamics and Beyond the Standard Model physics measurements, investigation of charged particle interactions with extreme electromagnetic fields, and exploring muon and proton beam acceleration. Possible applications of this collider include the studies of γγ and electron beam-fixed target/beamdump collider designs. Thus, the goal of the proposed IEF is to both carry out particle physics measurements in the 20-100 GeV ranges as well as to serve as an ANA demonstrator facility.

43 PARTICLE ACCELERATORS↗

ACCELERATING MICROREACTOR DEVELOPMENT AND DEPLOYMENT THROUGH JOINT PUBLIC TEST BEDS AND PRIVATE ADVANCED REACTOR DEVELOPMENT

The United States Department of Energy (DOE) has funded the National Reactor Innovation Center (NRIC) to accelerate the development and commercialization of small modular reactors and other advanced reactor technologies. As part of this effort NIRC is building two strategic assets at the Idaho National Laboratory (INL) to facilitate public-private partnerships for the development and testing of advanced nuclear microreactors and Small Modular Reactors (SMR). One will provide a safe, secure, and affordable location for High-Assay Low Enriched Uranium (HALEU) fueled reactors and a second for Highly Enriched Uranium (HEU) fueled reactors. Together these testbeds fill a nuclear testing infrastructure gap. The availability of such comprehensive testing facilities at the national labs eliminates the significant financial and operational burdens associated with each developer building and licensing their own test facilities. Consequently, this approach will not only accelerate technological innovation and reduce time-to-market for advanced nuclear solutions but it also underscores the DOE's commitment to fostering an ecosystem where nuclear energy will thrive as a clean, reliable, and efficient source of power. The Demonstration of Microreactor Experiments (DOME) and Laboratory for Operations and Testing in the United States (LOTUS) have planned availability in 2026, and 2027 respectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Demonstration of the Henon-Heiles Quasi-Integrable System at IOTA

The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. Its research program is focused on testing novel techniques for improving beam stability and quality, notably the concept of non-linear integrable optics. In this paper, we report the first results of experimental investigation of a quasi-integrable transverse focusing system with one invariant of motion, a Henon-Heiles type system implemented with octupole magnets. Good agreement with simulations is demonstrated on key parameters of achievable tune spread and dynamic aperture preservation. Resilience to perturbations and imperfections in the lattice is explored. We conclude by outlining future research plans and discussing applicability to future high intensity accelerators.

43 PARTICLE ACCELERATORS↗

High energy flux thermo-mechanical test of 1D-carbon-carbon fibre composite prototypes for the SPIDER diagnostic calorimeter

Operation of the thermonuclear fusion experiment ITER requires additional heating via injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in Padova, the production of negative ions will be studied and optimised. STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to characterise the SPIDER beam during short pulse operation (several seconds) to verify if the beam meets the ITER requirements about the maximum allowed beam non-uniformity (below ±10%). The major components of STRIKE are 16 1D-CFC (Carbon-Carbon Fibre Composite) tiles, observed at the rear side by a thermal camera. This contribution gives an overview of some tests under high energy particle flux, aimed at verifying the thermo-mechanical behaviour of several CFC prototype tiles. The tests were performed in the GLADIS facility at IPP (Max-Plank-Institut für Plasmaphysik), Garching. Dedicated linear and nonlinear simulations were carried out to interpret the experiments and a comparison of the experimental data with the simulation results is presented. The results of some morphological and structural studies on the material after exposure to the GLADIS beam are also given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capture cavity cryomodule for quantum beam experiment at KEK superconducting RF test facility

A capture cavity cryomodule was fabricated and used in a beam line for quantum beam experiments at the Superconducting RF Test Facility (STF) of the High Energy Accelerator Research Organization in Japan. The cryomodule is about 4 m long and contains two nine-cell cavities. The cross section is almost the same as that of the STF cryomodules that were fabricated to develop superconducting RF cavities for the International Linear Collider. An attempt was made to reduce the large deflection of the helium gas return pipe (GRP) that was observed in the STF cryomodules during cool-down and warm-up. This paper briefly describes the structure and cryogenic performance of the captures cavity cryomodule, and also reports the measured displacement of the GRP and the cavity-containing helium vessels during regular operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Counting Calories: Light Yield Studies for ADRIANO Calorimeter Prototype

To estimate the light yield for ADRIANO prototype, we must calibrate the light sensors as well as collect data from beams of known properties. Future experiments searching for new physics require special calorimetric techniques to detect new particles. ADRIANO2(A Dual Readout Integrally Active Non-segmented Option) is one such technique. Several prototypes have been tested at Mtest Facility at Fermi National Accelerator Laboratory in the last few years. This work consisting of new and more refined analysis of the data taken with the intent of improving the understanding of this calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixing and combustion effects in a sliding-wedge ram accelerator with hydrogen injection

The ram accelerator concept has been envisioned as the basis of a ground-based flight-test facility concept in which the test section follows the ram-accelerated projectile, and allows hydrogen mixing/combustion experiments to be conducted when hydrogen carried by the projectile is injected into the freestream. A numerical simulation is presently conducted for such mixing and combustion; the chemical reactions in question are modeled using a seven-step, seven-species model. A grid-adaptation procedure is used to resolve flow features in areas of high fluid and species gradients.

Ramakrishnan, R.↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Studies of Single Invariant Quasi-Integrable Nonlinear Optics at IOTA

The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. Its research program is focused on testing novel techniques for improving beam stability and quality, notably the concept of non-linear integrable optics. In this paper, we report on run 1 results of experimental studies of a quasi-integrable transverse focusing system with one invariant of motion, a Henon-Heiles type system implemented with octupole magnets. Good agreement with simulations is demonstrated on key parameters of achievable tune spread, dynamic aperture, and invariant conservation. We also outline current simulation and hardware improvement efforts for run 2, planned for fall of 2019.

43 PARTICLE ACCELERATORS↗

Validating pyORBIT for Modeling Beam Dynamics in the IOTA Ring

The Integrable Optics Test Accelerator (IOTA) ring is a new Fermilab facility dedicated to beam physics experiments, currently operating with 150 MeV electrons. Space charge effects are expected to be significant when it operates with 2.5 MeV protons. In this contribution, we present results of a suite of validation tests of PyORBIT, a PICstyle space charge code. Single particle dynamics of quasiintegrable optics using an octupole string in IOTA is compared with MADX, and shown to be in good agreement. Requirements for the convergence of space charge computations are systematically established and when possible, tests involving space charge are compared with theoretical predictions.

Li, Runze↗

Investigation of the Effects of Facility Background Pressure on the Performance and Voltage-Current Characteristics of the High Voltage Hall Accelerator

The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thruster's anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization and acceleration zones upstream shifting as a function of increased background pressure.

Electric Propulsion↗

Fermilab's Horizontal Test Stand Upgrade Overview and Commissioning

Cryo-assemblies with the Nb 3 Sn MQXFA low-beta quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab's magnet test facility. A total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational for more than a decade. In order to restore the test stand functions and meet the design and test requirements for the HL-LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded horizontal test stand was completed during the first cryo-assembly test in 2023. These tests verified the major cryo-mechanical installations, as well as the basic test stand operations, including controlled cooldown and operation at 1.9 K, magnet protection and process controls. Here, in this paper, overview of the Fermilab's horizontal test facility upgrade and commissioning of these upgrades are presented.

43 PARTICLE ACCELERATORS↗

Providing Experimental Infrastructure for Accelerating Advanced Reactor Demonstrations through the National Reactor Innovation Center

A suite of experimental infrastructure projects has been developed by the National Reactor Innovation Center to accelerate advanced reactor demonstrations and facilitate their development, addressing crucial gaps in data, materials characterization, and modeling. First, the Molten Salt Thermophysical Examination Capability (MSTEC) provides a specialized platform for post-irradiation characterization of molten salt reactor fuel, coolant salts, and structural materials, essential for supporting the design and operation of advanced reactors and future commercial molten salt reactor development and licensing. The Virtual Test Bed (VTB) complements these efforts by leveraging advanced modeling and simulation tools to evaluate reactor performance and safety. Serving as a library of reference models, the VTB offers a database of multiphysics reactor models, facilitating rapid safety evaluations and includes continuous software quality assurance, crucial for accelerating deployment while maintaining reliability. Additionally, the Helium Component Test Facility (HeCTF) addresses the need for high-temperature helium-cooled reactor component testing. As the first-of-its-kind facility in the United States, HeCTF emulates high-temperature gas reactor conditions, reducing time and cost associated with component validation, thereby accelerating reactor development. Finally, In-cell Thermal Creep Frames provide a unique solution for obtaining thermal creep data from irradiated materials, critical for materials qualification and licensing. Developed by the National Reactor Innovation Center, these compact frames enable the examination of previously irradiated materials, overcoming traditional limitations and enhancing the understanding of mechanical properties crucial for reactor development. Collectively, these experimental infrastructure projects form a comprehensive framework aimed at expediting advanced reactor demonstrations, fostering innovation, and ensuring the viability of next-generation nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The Machine Protection System for the Fermilab Accelerator Science and Technology Facility

The Machine Protection System (MPS) for the Fermilab Accelerator Science and Technology Facility (FAST) has been implemented and tested. The system receives signals from several subsystems and devices which conveys the relevant status needed to the safely operate the accelerator. Logic decisions are made based on these inputs and some predefined user settings which in turn controls the gate signal to the laser of the photo injector. The inputs of the system have a wide variety of signal types, encoding methods and urgencies for which the system is designed to accommodate. The MPS receives fast shutdown (FSD) signals generated by the beam loss system and inhibits the beam or reduces the beam intensity within a macropulse when the beam losses at several places along the accelerator beam line are higher than acceptable values. TTL or relay contact signals from the vacuum system, toroids, magnet systems etc., are chosen with polarities that ensure safe operation of the accelerator from unintended events such as cable disconnection in the harsh industrial environment of the experimental hall. A RS422 serial communication scheme is used to interface the operation permit generator module and a large number of movable devices each reporting multi-bit status. The system also supports operations at user defined lower beam levels for system conunissioning. The machine protection system is implemented with two commercially available off-the-shelf VMEbus based modules with on board FPGA devices. The system is monitored and controlled via the VMEbus by a single board CPU

Wu, Jinyuan↗