Search NASA⌕ Search

SEARCH · Search NASA

Results for “argon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Precision ultranarrow-linewidth resonance excitation (PURE) preparation of a molecular beam of nitric oxide molecules for inelastic scattering with argon

We recently reported a novel technique that utilizes narrow-linewidth lasers to selectively excite molecules into a pure quantum state with a well-resolved, tunable distribution of velocities [O. A. Krohn and D. W. Chandler, J. Phys. Chem. Lett. 15(50), 12455–12463 (2024)]. We refer to the preparation of molecules by this technique as precision ultranarrow-linewidth resonant excitation (PURE) preparation. Here, in this study, we pair this PURE preparation methodology with active frequency stabilization of the quantum cascade laser that drives the excitation. In doing so, highly velocity-resolved packets of molecules are possible, with the limitations of this velocity resolution set by the stability of the laser locking and the spectral linewidth of the transition. We show that side-of-fringe locking to a Doppler-broadened absorption spectrum of our target molecule is sufficiently stable for PURE preparation of molecules for long timescales (several hours) with highly resolved velocity spreads (σ < 3 m/s). To demonstrate the scientific utility of this new capability, we present differential cross sections from scattering between a neat molecular beam of argon and a velocity-selected beam of nitric oxide (NO) in a pure quantum state. We observe well-resolved quantum diffraction oscillations in the forward-scattered collisions as well as general trends consistent with prior characterized collisions of NO + Ar.

Krohn, Olivia A. [Sandia National Laboratories (SN↗

Characterization of uncertainties in electron-argon collision cross sections

Abstract The predictive capability of a plasma discharge model depends on accurate representations of electron-impact collision cross sections, which determine the corresponding reaction rates and electron transport properties. The values of cross sections can be known only approximately either through experiments or simulations and are thus subject to uncertainties. Quantifying the uncertainties in plasma simulations allows us to assess the reliability of simulations and to provide a basis for interpreting discrepancies between simulations and experiments. For such uncertainty quantification of plasma simulations, it is essential to quantify the uncertainties of the underlying cross sections. Although much effort has been committed to calibrate the cross section values, their uncertainties are not well investigated. We characterize uncertainties in electron-argon atom collision cross sections using a Bayesian framework. Six collision processes—elastic momentum transfer, ionization, and four excitations—are characterized with semi-empirical models, which effectively capture the features important to the macroscopic properties of the plasma. A probability model for the uncertain parameters of these semi-empirical models is developed. Specifically, a Gaussian-process likelihood model is proposed to capture discrepancies among data sets, as well as the model-form inadequacies of the semi-empirical models. Two other likelihood models are compared with the proposed Gaussian-process model, to illustrate the importance of the choice of the likelihood model. The cross section models are calibrated using the electron-beam experiments and ab-inito quantum simulations. The resulting calibrated uncertainties capture well the scattering among the data sets. The calibrated cross section models are further validated against swarm-parameter experiments and zero-dimensional Boltzmann equation simulations of widely used cross section datasets.

Chung, Seung Whan (ORCID:0000000302501549)↗

Simulation of DIII-D disruption with argon pellet injection and runaway electron beam

Abstract The next generation of large tokamaks, including ITER, will be equipped with a disruption mitigation system (DMS) that can be activated if a disruption is deemed to be imminent. Introducing impurities by pellet (large or shattered) or massive gas injection has been shown to be an effective mitigation mechanism on many tokamaks. The goal of the mitigation is to lessen the thermal and electromagnetic loads from the disruption without generating enough high-energy (runaway) electrons to damage the device. Variations of this mitigation process with impurity injection are presently being tested on many experiments. We have modeled one such impurity injection experiment on DIII-D using the M3D-C1 nonlinear 3D extended MHD code (Jardin et al 2012 Comput. Sci. Discovery 6 014002), The model includes an argon large pellet injection and ablation model, impurity ionization, recombination, and radiation, and runaway electron formation and subsequent evolution, including both Dreicer and avalanche sources. We obtain reasonable agreement with the experimental results for the timescale of the thermal and current quench and for the magnitude of the runaway electron plateau formed during the mitigation. This is the first 3D full MHD simulation with pellets and REs to simulate the disruption process and it also provides a partial validation of the M3D-C1 DMS model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First application of a liquid argon time projection chamber for the search for intranuclear neutron-antineutron transitions and annihilation in 40 Ar using the MicroBooNE detector

We present a novel methodology to search for intranuclear neutron-antineutron transition (n→n̅) followed by n̅-nucleon annihilation within an 40 Ar nucleus, using the MicroBooNE liquid argon time projection chamber (LArTPC) detector. A discovery of n→n̅ transition or a new best limit on the lifetime of this process would either constitute physics beyond the Standard Model or greatly constrain theories of baryogenesis, respectively. The approach presented in this paper makes use of deep learning methods to select n→n̅ events based on their unique features and differentiate them from cosmogenic backgrounds. The achieved signal and background efficiencies are (70.22 ± 6.04)% and (0.0020 ± 0.0003)%, respectively. A demonstration of a search is performed with a data set corresponding to an exposure of 3.32 ×10 26 neutron-years, and where the background rate is constrained through direct measurement, assuming the presence of a negligible signal. With this approach, no excess of events over the background prediction is observed, setting a demonstrative lower bound on the n→n̅ lifetime in 40 Ar of τ m ≳ 1.1×10 26 years, and on the free n→n̅ transition time of τ n→n̅ ≳ 2.6×10 5 s, each at the 90% confidence level. This analysis represents a first-ever proof-of-principle demonstration of the ability to search for this rare process in LArTPCs with high efficiency and low background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle hit clustering and identification using point set transformers in liquid argon time projection chambers

Liquid argon time projection chambers are often used in neutrino physics and dark-matter searches because of their high spatial resolution. The images generated by these detectors are extremely sparse, as the energy values detected by most of the detector are equal to 0, meaning that despite their high resolution, most of the detector is unused in a particular interaction. Instead of representing all of the empty detections, the interaction is usually stored as a sparse matrix, a list of detection locations paired with their energy values. Traditional machine learning methods that have been applied to particle reconstruction such as convolutional neural networks (CNNs), however, cannot operate over data stored in this way and therefore must have the matrix fully instantiated as a dense matrix. Operating on dense matrices requires a lot of memory and computation time, in contrast to directly operating on the sparse matrix. We propose a machine learning model using a point set neural network that operates over a sparse matrix, greatly improving both processing speed and accuracy over methods that instantiate the dense matrix, as well as over other methods that operate over sparse matrices. Compared to competing state-of-the-art methods, our method improves classification performance by 14%, segmentation performance by more than 22%, while taking 80% less time and using 66% less memory. Compared to state-of-the-art CNN methods, our method improves classification performance by more than 86%, segmentation performance by more than 71%, while reducing runtime by 91% and reducing memory usage by 61%.

calibration and fitting methods↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Characterization of UV optical components for photon detector calibration in liquid argon TPCs

Large liquid argon time projection chambers (LArTPCs)require stable and well-characterized delivery of ultraviolet (UV)light for in situ calibration of photosensors at cryogenictemperatures. This article reports bench-top and cryogenicmeasurements of the optical components used in a UV lightcalibration system, including multi-mode fused-silica fibers,SMA-to-SMA connectors, optical fiber feedthroughs, andlight-diffuser assemblies. Light loss in several fiber types and SMAconnectors was measured across wavelengths from275–970 mm. In addition,light-loss measurements of the tested fibers after severalliquid-nitrogen thermal cycles showed no statistically significantdegradation relative to baseline measurements, and high-rate pulsedexposure (30–90 million pulses from a275 nm LED) likewise showed nomeasurable aging in jacketed fibers. A compact, palm-sized,3D-printed PEEK diffuser housing with stacked UV-grade fused-silicadiffusers yields Lambertian emission and the most uniform angulardistribution. Optical components exhibiting improved UV transmissionwere deployed successfully in multiple DUNE small- and large-scaleprototypes, demonstrating reliable operation of UV light calibrationsystem. These findings inform component selection and calibrationprocedures for achieving reliable, uniform UV light delivery inlarge-scale cryogenic detectors such as DUNE.

Behera, B. [South Dakota Sch. Mines Tech.] (ORCID:↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Properties of Heavy Cosmic Nuclei Phosphorus, Chlorine, Argon, Potassium, and Calcium: Results from the Alpha Magnetic Spectrometer

We report the unique properties of cosmic phosphorus (P), chlorine (Cl), argon (Ar), potassium (K), and calcium (Ca) fluxes in the GV to TV rigidity range collected by the Alpha Magnetic Spectrometer (AMS) on the International Space Station. With a total of one million events collected over 13.5 years, we observed that the rigidity dependencies of the five fluxes are well described by the sums of a primary cosmic ray component and a secondary cosmic ray component. The abundance ratios of all five elements to Si at the source are accurately determined independent of cosmic ray propagation. The source abundance of Ar and Ca (even-𝑍 elements) is larger than P, Cl, and K (odd-𝑍 elements). The secondary components of the P and the Cl fluxes are each ∼1/3 of the F flux, and the secondary components of the Ar, K, and Ca fluxes are each ∼1/2 of the F flux. The twenty elements measured by AMS, from He to Ca and Fe, can be categorized into four classes, two primary and two secondary, based on their rigidity dependence.

cosmic ray acceleration↗

Neutron reconstruction via blips in liquid argon time projection chambers

Neutrons are important final-state particles in neutrino interactions, yet they are not considered or reconstructed in most current neutrino liquid argon time projection chamber (LArTPC) physics analyses. In this paper, we present a simulation-based proof-of-concept study of neutron reconstruction in a generic LArTPC detector. Leveraging isolated, MeV-scale energy deposits, or blips, from neutron inelastic scattering, and using realistic blip response from published experimental results, we demonstrate the capability to identify neutrons and to reconstruct the direction and energy of the final-state neutron system in sub-GeV neutrino interactions. We then explore how neutron-related blip attributes can be used to improve physics studies of neutrino interactions, such as enhancing neutrino-antineutrino separation in atmospheric neutrinos and reverse-horn-current beam neutrinos. This study provides an initial quantification of LArTPC neutron reconstruction capabilities, which we expect to improve with future advancements in blip reconstruction, identification, and classification algorithms, as well as the modeling of neutrons.

Morquecho, Miguel Hernandez [Univ. of Minnesota, M↗

Physics prospects with MeV neutrino-argon charged current interactions using enhanced photon detection in future LArTPCs

Here, we investigate MeV-scale electron neutrino charged current interactions in a liquid argon time projection chamber (LArTPC) equipped with an enhanced photon detection system. Using simulations of deposited energy in charge and light calorimetry, we explore the potential for dual calorimetric neutrino energy reconstruction. We found energy reconstruction based on light-only calorimetry has a better resolution than combined charge and light calorimetry when hadrons are produced in these events. Meanwhile, enhanced light detection offers improved nanosecond timing resolution and broad optical coverage, enabling neutron tagging and identification of delayed low-energy gamma emissions. These advancements open new avenues in low-energy neutrino physics in next-generation LArTPCs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of nuclear effects in neutrino-argon interactions using generalized kinematic imbalance variables with the MicroBooNE detector

We present a set of new generalized kinematic imbalance variables that can be measured in neutrino scattering. These variables extend previous measurements of kinematic imbalance on the transverse plane and are more sensitive to modeling of nuclear effects. We demonstrate the enhanced power of these variables using simulation and then use the MicroBooNE detector to measure them for the first time. We report flux-integrated single- and double-differential measurements of charged-current muon neutrino scattering on argon using a topology with one muon and one proton in the final state as a function of these novel kinematic imbalance variables. These measurements allow us to demonstrate that the treatment of charged current quasielastic interactions in genie version 2 is inadequate to describe data. As a result, they reveal tensions with more modern generator predictions particularly in regions of phase space where final state interactions are important.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the differential cross section for neutral pion production in charged-current muon neutrino interactions on argon with the MicroBooNE detector

We present a measurement of neutral pion production in charged-current interactions using data recorded with the MicroBooNE detector exposed to Fermilab’s booster neutrino beam. The signal comprises one muon, one neutral pion, any number of nucleons, and no charged pions. Studying neutral pion production in the MicroBooNE detector provides an opportunity to better understand neutrino-argon interactions, and is crucial for future accelerator-based neutrino oscillation experiments. Using a dataset corresponding to 6.86 ×10 20 protons on target, we present single-differential cross sections in muon and neutral pion momenta, scattering angles with respect to the beam for the outgoing muon and neutral pion, as well as the opening angle between the muon and neutral pion. Data extracted cross sections are compared to generator predictions. We report good agreement between the data and the models for scattering angles, except for an over-prediction by generators at muon forward angles. Similarly, the agreement between data and the models as a function of momentum is good, except for an underprediction by generators in the medium momentum ranges, 200–400 MeV for muons and 100–200 MeV for pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-compensating light calorimetry with liquid argon time projection chamber for GeV neutrino physics

The Liquid Argon Time Projection Chamber (LArTPC) is a powerful dual calorimeter capable of estimating particle energy from both ionization charge and scintillation light. Here, our study shows that, due to the recombination luminescence, the LArTPC functions as a self-compensating light calorimeter: the missing energy in the hadronic component is compensated for by the increased luminescence relative to the electromagnetic component. Using 0.5-5 GeV electron neutrino charged current interactions as a case study, we show that good compensation of the electron-to-hadron response ratio (e/h) from 1-1.05 can be achieved across a broad range of drift electric fields (0.2-1.8 kV / cm), with better performance for neutrino energies above 2 GeV. This study highlights the potential of light calorimetry in LArTPCs for GeV neutrino energy reconstruction, complementing traditional charge calorimetry. Under ideal conditions of uniform light collection, we show that LArTPC light calorimetry can achieve an energy resolution comparable to the charge imaging calorimetry. Challenges arising from nonuniform light collection in large LArTPCs can be mitigated with a position-dependent light yield correction derived from 3D charge signal imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Simultaneous Measurement of Differential Muon-Neutrino Charged-Current Cross Sections on Argon for Final States with and without Protons Using MicroBooNE Data

We report the first double-differential neutrino-argon cross section measurement made simultaneously for final states with and without protons for the inclusive muon neutrino charged-current interaction channel. The proton kinematics of this channel are further explored with a differential cross section measurement as a function of the leading proton’s kinetic energy that extends across the detection threshold. These measurements use data collected with the MicroBooNE detector from 6.4 × 10 20 protons on target from the Fermilab booster neutrino beam with a mean neutrino energy of ∼ 0.8 GeV . Extensive data-driven model validation utilizing the conditional constraint formalism is employed. This motivates enlarging the uncertainties with an empirical reweighting approach to minimize the possibility of extracting biased cross section results. The extracted nominal flux-averaged cross sections are compared to widely used event generator predictions revealing severe mismodeling of final states without protons for muon neutrino charged-current interactions, possibly from insufficient treatment of final state interactions. These measurements provide a wealth of new information useful for improving event generators which will enhance the sensitivity of precision measurements in neutrino experiments. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗