Search NASA⌕ Search

SEARCH · Search NASA

Results for “boil-off”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

NASA's Cryogenic Fluid Management Technology Development Roadmaps

The maturation of Cryogenic Fluid Management (CFM) Technologies is essential for achieving NASA's future long duration missions. Propulsion systems utilizing cryogens are necessary to achieve NASA's exploration missions to the moon, Mars, and beyond. Current State Of the Art (SOA) CFM technologies enable cryogenic propellants to be stored for several hours prior to their use. However, some envisioned mission architectures require that cryogens to be stored for two years or longer. The fundamental roles of CFM technologies are long term storage of cryogens, propellant tank pressure control and propellant delivery. In the presence of heat, the cryogens will "boil-off" over time resulting in excessive pressure buildup, off-nominal propellant conditions for engine consumption, and propellant loss. To achieve long term storage and tank pressure control, the CFM elements will intercept and/or remove any heat from the propulsion system. All functions are required to be performed both with and without the presence of a gravitational field. Which CFM technologies are required is a function of the cryogens used, mission architecture, vehicle design and propellant tank size. To enable NASA's crewed missions beyond Low Earth Orbit, a total of twenty-seven CFM technologies have been identified to support various In-Space Stages and Lander/Ascent Vehicles. A set of CFM Technology Development Roadmaps have been created identifying the current Technology Readiness Level (TRL) of each element, current technology "gaps", and existing technology development efforts. The roadmaps include a methodical approach and schedule to achieve a flight demonstration, hence maturing CFM technologies to TRL 6/7 for infusion into the NASA's exploration elements. Additionally, a survey of the aerospace industry was completed to understand their views on the various technologies and how they would be infused. This does not cover all possible technologies, but rather those that are of interest to NASA specifically.

Cryogenic fluid management↗

Thermal Model of a Zero Boil Off System for the Nuclear Thermal Propulsion System

NASA is currently developing an updated concept for a nuclear thermal propulsion (NTP) system. To enable this concept, efficient thermal insulation and cryocooler heat exchanger systems are required to eliminate boil-off of propellant. This paper presents the results of a thermal model used to assess the feasibility of using active cooling with a tube-on-tank heat exchanger configuration for the inline tank of the NTP system. Results show that: cryocooler working fluid temperature and mass flow rate can be adjusted to achieve zero boil off (ZBO) with broad area cooling, over-sizing the cryocooler lift directly translates into a reduction in tank pressure, and broad area cooling may still maintain ZBO despite the reduced heat transfer between tank wall and propellant that is expected in reduced gravity.

zero boil off↗

Two-Phase Convection Heat Transfer Correlations for Liquid Hydrogen Pipe Chilldown

Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.

critical heat flux↗

Testing of Heat Flux Sensors at Cryogenic Temperatures

Normally, in order to characterize multilayer insulation installed onto a test tank, the boil-off of the tank is measured and then heat loads from structural and fluid penetrations are calculated from temperature measurements throughout the system. For the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig testing, it was determined that this approach would have significant uncertainties (over 50%) and that another method was needed to characterize the heat load through the blanket. Heat flux sensors are widely used to measure heat loads and characterize insulation systems at room temperature, however, the heat fluxes measured are usually two orders of magnitude higher than high performance MLI. Three different heat flux sensors were initially checked out on a liquid hydrogen calorimeter. One was chosen for actual implementation and 20 sensors were ordered. Of those sensors, calibration was attempted on 7 of the sensors. The results from testing and calibration are discussed.

cryogenic fluid management↗

A Conceptual Design Study for an Unmanned, Reusable Cargo Lunar Lander

Motivated by the aggressive timeline of NASA’s Artemis Program, the feasibility of evolving a mid-sized, reusable and refuelable cargo lunar lander technology demonstrator into the descent element of the three- stage human lander was assessed with the goal of forming synergies between both acquisition programs. Requirements for such a concept are that it must be deployed on commercial launch vehicles that are expected to enter into service consistent with Artemis’ timeline. In order to assess this concept’s feasibility, a physics-based analysis of alternatives was conducted where mission and vehicle architectures are traded side-by-side. Mission trades considered include the impacts of traveling to near-rectilinear halo orbit quickly versus slowly; vehicle trades include fuel and oxidizer tank configurations, number of engines, and propellant combinations, as well as several technology options, e.g. reduced and zero boil-off strategies. Results and discussions are presented to facilitate the consideration of this concept. lunar lander, systems analysis, multidisciplinary design and analysis, space systems, analysis of alternatives,

Robertson, Bradford↗

Solar White Thermal Coating for Cryogenic Propulsion Systems

NASA is currently conducting research into the potential of storing cryogenic fluid in low Earth orbit (LEO). Having cryogenic propellant readily available for high-performance propulsion systems can be very beneficial for deep space missions in the near future. One of the key challenges to storing cryogenic fluid in LEO is minimizing boil-off. To address the challenge, NASA is evaluating new concepts in thermal insulation. One recent experimental study evaluated the feasibility of using Yttrium Oxide (Y2O3), formed into tiles or spray coating that can potentially be used as a thermal coating for cryogenic propellant storage applications in deep space. Due to its temperature and wavelength dependent optical properties, this “solar white” material can reflect a vast majority of the Sun’s radiative energy while having a very high infrared emissivity for rejecting heat to deep space. As a part of the material development and proof of concept testing, multiple tests have been run at KSC and GRC to demonstrate the performance of the material. At GRC, the tests were run using the Deep Space Solar Simulator (DS3) which contains a thermal vacuum chamber in which the solar white sample was exposed to a deep space environment (< 10 K, optically dense walls) while under full illumination via solar lamp. In order to improve the use of the test results and apply them to spacecraft, there is a need to be able to model the material properties within NASA’s standard thermal modeling tools. As such, it was set out to verify a thermal model of one of the experiments using Thermal Desktop with Sinda. The thermal model of the DS3 test setup includes the solar white sample along with a solar lamp simulator capable of outputting heat at varying wavelengths. The model was developed in order to validate the test results and also to help predict results that will be obtained in future tests. This paper will review the modeling methods and thermal analysis results for various test cases that were run within the DS3 facility.

Cryogenic↗

Space Exploration Applications for Development of High Capacity Cryocoolers

Long term storage of cryogens is necessary to enable NASAs long duration crewed missions to both the lunar and Martian surfaces. Such missions require in-space transport systems such as Nuclear Thermal Propulsion (NTP), and descent/ascent vehicles for transportation to and from the lunar and Martian surfaces. NTP systems and Lunar/Martian landers utilize cryogenic fluids to minimize architectural volume and mass. To further enhance the capability of these cryogenic systems, the Agency is putting emphasis on reusability, which requires the NTP and ascent/descent elements be replenished on-orbit via tankers or propellant depots, or on the lunar or Martian surface using liquefied in-situ produced propellants. NTP is one of the leading propulsion option for human Mars missions and requires liquid hydrogen to be stored on-orbit for over four years. For such a long duration mission, near “Zero Boil-Off” (ZBO) must be achieved which requires an optimized suite of passive Cryogenic Fluid Management technologies and active cooling (cryocoolers). Tens of Watts of 20K cooling is required to achieve ZBO conditions for NTP, however two-stage cooling using both 20K and 90K systems can lead to a significant reduction in both active cooling mass and power. The use of in-situ resources for lunar and Martian missions will require 150 Watts of 90K cooling for oxygen liquefaction and 300 Watts of 20K cooling for hydrogen liquefaction (lunar only). Descent/Ascent vehicles, propellant depots, and tankers will also require the use of cryocoolers to achieve ZBO conditions. To support these programs, NASA is developing high capacity 20K and 90K reverse turbo-Brayton cycle cryocoolers which offer a scalable, high efficiency, low vibration solution.

cryocooler↗

Probabilistic Modeling of a Three-Stage Human Landing System Architecture

Space Policy Directive-1 has led to NASA partnerships with commercial entities on procurement which includes the development of the Human Landing System (HLS) [1]. With the goal of delivering human crew to the lunar surface by 2024, system uncertainties become an important obstacle to the maturation of multiple new, driving technologies and mission concepts of the HLS program. As unmitigated uncertainties have previously led to failed development programs, these risks and their impacts must be understood and handled to ensure program success [2]. Sources of uncertainty include novel engine designs and configurations, increased reliance on cryogenic fluid management(CFM), and refueling technologies—which propagate as high-level performance metrics such as overall propellant mass and engine performance. Also, the occurrence of operational uncertainties—e.g. launch conditions or need to abort during the mission—can cause cascading effects on the rest of the mission that are difficult to definitively quantify, and are outside the scope of control. These concrete examples and other occurrences can be categorized as either epistemic or aleatory uncertainties.Epistemic uncertainty arises due to a lack of knowledge and can be alleviated with design and program maturation. Aleatory uncertainty is due to the inherent randomness of the system and cannot be directly reduced, unlike epistemic uncertainty. Robust design and probabilistic methods can compensate for aleatory effects. A taxonomy of uncertainty is referred to for this work [3]. In this paper, a probabilistic methodology to handle uncertainties has been demonstrated on a three-element HLS concept [1, 4], which allows tracking of current best estimates of the concept and assessment of concept design robustness against uncertainties. A sample case has been completed for this abstract, and an expansion on the methodology will be included in the final paper. This methodology has two key parts: first, the creation of a dynamic architecture model of a three-element HLS concept; and second, its use with surrogate modeling and range estimating techniques to capture and propagate uncertainties. This abstract will cover the basics of the approach used, and further details and justifications will be in the final paper.The mission profile associated with this three-element concept (Fig 1) was modeled as a set of mission events that facilitated mass changes, idles, or spacecraft maneuvers. The mission profile scope starts with each element’s NRHO orbit insertion and aggregation and ends at post-sortie rendezvous with Orion. More detail on the mission profile will be in the final paper. The DYnamic Rocket EQuation Tool (DYREQT), a space systems synthesis and sizing framework used by NASA, was used as the physics framework to model the HLS architecture for applying the probabilistic methodology [5, 6]. Specifically, a parametric representation of the lander, ascent, and transfer elements and the mission profile of each element was established, with vehicle and mission parameters available as inputs to allow for a dynamic model. Each vehicle stage was modeled with high-level performance metrics, using Isp and propellant mass fraction (PMF) to remain parametric. For the probabilistic analysis, uncertainties of interest within the HLS concept were enumerated and represented as parameters within the DYREQT model as inputs for vehicle stages or mission profile events. These parameters were frozen at their nominal values for the purposes of baselining architecture performance and sizing the vehicle appropriately based on reference documentation [1]. Range estimating—a probabilistic method that combines Monte Carlo sampling, focus on critical parameters, and heuristics to assess risk and opportunities—is traditionally used with Mass Equipment Lists (MELs), but has been adapted with operational parameters as well as vehicle parameters in theDYREQT model to capture mission uncertainty alongside vehicle uncertainty [7, 3]. This method was selected due to its application and insight on a system from a bottom-up perspective, independence from historical rules of thumb, and ability to generate sensitivities based on design decisions and uncertainties. As a sample case for the abstract, the boiloff rates of the vehicle elements and the loiter times during the mission (simulating launch time variations and changing window of opportunities) were used with range estimating to provide preliminary results. To perform the range estimation portion of this methodology (depicted in Fig. 3, further details in final paper), the DYREQT model was sampled using a Design of Experiments (DoE) to efficiently explore the architecture design space with respect to the sample set of uncertainty parameters; 5,000 cases via Latin Hypercube Sampling were computed on the DYREQT architecture model. Then, the results were used to create surrogate models, multivariate regressions that can visualize hypercube trends in the design space, of the architecture with respect to the uncertainty parameters. Range estimating was applied to the surrogates instead of the actual models, which saves computational expense due to the bulk of cases needed for the Monte Carlo simulation as part of range estimating. Uncertainty parameters were sampled independently from triangular distributions using the DoE ranges as ‘min’ and ‘max’, and the nominal value as ‘most likely’. Based engineering intuition, some uncertainty parameters are correlated—e.g. if the main propellant has a high boil-off rate, the oxidizer should follow suit as both are related to CFM technology.While a Monte Carlo simulation samples all inputs as independent, the results would show model correlations; thus, it is efficient to sample the inputs as correlated. Using a correlation matrix constructed for the uncertainty parameters, previously independent samples were transformed to perform a Correlated Monte Carlo. A table for the DoE ranges and probability distribution parameters is shown in Table 1, and more details on Correlated Monte Carlo Simulations will be discussed in the final paper. The model’s resulting DoE showed that multivariate polynomial equations fit via least squares method captured its behavior accurately for the sample case. For the Correlated Monte Carlo Simulation, a positive correlation between fuel and oxidizer boiloff rates was used as a demonstration. 10,000 cases were computed with the surrogates and the launched masses for each vehicle element was collated. The results can be displayed in a probability density function (PDF), showing the impact of the uncertainty parameters chosen. Integrating the PDFs will yield a cumulative distribution function (CDF) that shows the cumulative probability of a given value on the x-axis. For the sample case, the elements’ launch mass margin was calculated and represented in as CDFs, as a demonstrated representation of figures of merit for the HLS concept. For the lander and ascent elements, the NRHO mass insertion limit is 16t; the transfer element has a limit of 30t [1]. It can be seen with Figure 2 that this probabilistic methodology can provide insight into mass margin with respect to the uncertainties being modeled. Currently, the results show that the lander (descent) vehicle element has the most restrictive design space; it is the only element to show a 10% probability of negative margin. Further analysis on the Monte Carlo results will show sensitivities for driving constraints and parameters for architecture feasibility, which can lead to establishing potential mission rules.The combination of range estimating with a parametric architecture model for HLS demonstrated the capability of this probabilistic methodology in a sample case. As the HLS development progresses, this methodology has the potential for keeping current best estimates of architecture performance for awarded concepts due to the flexibility in DYREQT’s modeling framework and its parametric nature. Concept maturation and increased epistemic knowledge can be injected into the model probabilistic modeling, and thus continue to track probability of mission success.

Stephanie Y Zhu↗

Vapor Cooling of a Structural Skirt for a Large-Scale Hydrogen Tank

The demonstration of vapor cooling on a structural skirt was one of the main objectives of the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) testing. SHIIVER consisted of a 4-meter diameter stainless steel tank with an aluminum forward skirt. The forward skirt was cooled by directing effluent vapor from the tank through two flow channels that each went 360 degrees around the interior of the skirt in a helical pattern. Flow rates, temperatures, and pressures in the system were measured allowing for the calculation of heat load removed via cooling stream and heat load reduction into the tank. Testing occurred at fill levels between 25% and 90% full using both liquid hydrogen and liquid nitrogen. Boil-off rate was varied independent of the skirt performance by adding multilayer insulation over the spray-on-foam insulation on the tank domes, while leaving the barrel insulated only with spray-on-foam. The results from the testing, which demonstrate vapor cooling reversed heat flow from the skirt into the tank and reduces total propellant heat load by as much as 19%, are analyzed and discussed.

Cryogenic Fluid Management↗

Testing of TVS Augmented Injectors for Tank-to-Tank Transfer of Cryogens

NASA is developing reusable cryogenic systems to enable manned missions to the Moon and Mars. These cryogenic systems will require replenishing cryogens on-orbit via a tanker or propellant depot with minimal loss to boil-off. Three additively manufactured injectors augmented with a Thermodynamic Venting System have been developed for use in tank-to-tank cryogenic fluid transfer. A Vented Chill/No-Vent Fill approach to tank-to-tank transfer has been the industry standard and is explored in this work with emphasis on injector spray patterns and compared to the Charge-Hold-Vent chill method.

Cryogenic Transfer↗

Testing of TVS Augmented Injectors for Tank-to-Tank Transfer of Cryogens

NASA is developing reusable cryogenic systems to enable manned missions to the Moon and Mars. These cryogenic systems will require replenishing cryogens on-orbit via a tanker or propellant depot with minimal loss to boil-off. Three additively manufactured injectors augmented with a Thermodynamic Venting System have been developed for use in tank-to-tank cryogenic fluid transfer. A Vented Chill/No-Vent Fill approach to tank-to-tank transfer has been the industry standard and is explored in this work with emphasis on injector spray patterns and compared to the Charge-Hold-Vent chill method.

Cryogenic Transfer↗

Development of a Test Article to Demonstrate the Long Duration Storage of Liquid Hydrogen via a Two-Stage Active Cooling Approach

A NASA team is developing a test article for the purpose of demonstrating the long duration storage of liquid hydrogen utilizing passive Cryogenic Fluid Management and cryocoolers via a two-stage active cooling approach. Funded by NASA’s Technology Demonstration Mission Program and managed by the Cryogenic Fluid Management Portfolio Project, the team is leveraging demonstrations conducted under pervious NASA activities to develop a fully integrated test article that will demonstrate the zero boil-off storage of liquid hydrogen. This paper discusses the previous activities being leveraged from NASA’s Cryogenic Propellant Storage and Transfer project, the test article design and build, hardware and instrumentation selections, control methodology, and the planned primary and secondary test objectives. The test article assembly and demonstration are both to be conducted in the East Test Area at NASA Marshall Space Flight Center and are currently scheduled for Fiscal Year 2024.

Active Cooling↗

Comparison of Liquefaction Testing with Liquid Nitrogen and Liquid Oxygen

Liquid nitrogen is often used as a substitute for oxygen testing due to safety concerns, and the general similarity between their fluid properties. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, an opportunity arose to compare liquid nitrogen and liquid oxygen behavior using the same test hardware in similar test conditions. Comparative testing would verify whether the system response to nitrogen and oxygen would behave in a similar manner. Tests that were investigated include system boil-off heat load determination, autogenous pressurization, cryocooler loop initiation, and cryocooler loop operations. Results from testing are shown and compared to verify that liquid nitrogen and liquid oxygen tests yield similar system responses, and that nitrogen can be used as a substitute for oxygen in developmental tests at cryogenic temperatures.

Cryogenic Fluid Management↗

CFD Modeling & Validation of Single Bubble Growth During Cavitation in Zero Gravity

Cryogenic Fluid Management (CFM) in zero gravity represents a vital area of research as NASA pursues future long-duration space missions. Success of these missions relies heavily on the ability to store and transfer the cryogenic liquid fuels efficiently and safely. In the Zero Boil-Off Tank (ZBOT-1) Experiment in 2018, unexpected and intense phase change occurred at the screened Liquid Acquisition Device (LAD) during tank pressure control that was later attributed to cavitation. The cavitation ultimately resulted in pump failure. Since cryogen cavitation during storage and transfer of propellants in microgravity has been a source of serious concern for the aerospace community, a series of drop tower experiments with liquid methane were also performed at the University of Bremen to carefully study cavitation from a single bubble nucleus in an engineered micron-sized wall cavity. As the test cell is depressurized during the 10-second drop, cavitation causes bubble growth from the nucleus. Here, in a collaboration between the Case Western Reserve University and University of Bremen, we present a two-phase Computational Fluid Dynamics (CFD) model of bubble growth from a single wall cavity during depressurization in microgravity. Both 2D axisymmetric and 3D parametric simulation case studies are performed to show the evolution of the bubble growth. The model uses a Volume of Fluid (VOF) approach with and without adaptive mesh refinement and adaptive time stepping to capture the growth dynamics using an explicit formulation with algebraic reconstruction of the interface. CFD results show good agreement with corresponding experiment. Based on the velocity, temperature, and volume fraction fields generated by the validation case studies, detailed discussion and analysis of fluid flow and heat transfer during bubble growth process are presented to delineate the intricacies of the cavitation process. Strengths and shortcomings of the present numerical approach in capturing this phenomenon are also highlighted.

Two Phase Flow↗

The ZBOT-NC Experiment - Effects of Non-Condensable Gases on Propellant Tank Pressurization and Pressure Control

Introduction Integral to all phases of NASA’s projected planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. It is greatly advantageous to develop innovative vent-less pressure control designs based on cooling/mixing of the bulk tank fluid to allow storage of the cryogenic fluid with zero or reduced boil-off. The presence of noncondensable gases, can interfere with the condensation at the interface impacting tank pressure control during subcooled jet mixing especially in microgravity. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small-scale experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena associated with storage tank pressurization and pressure control in microgravity. The ZBOT-1 experiment was performed on the ISS 2017-2018 timeframe and collected data to validate a state-of-the-art CFD model for tank pressurization and pressure control for a pure system. The ZBOT-NC Experiment is the second experiment in the series to be performed on the International Space Station (ISS) in 2025. Its goal is to investigate the effects of noncondensable gases on interfacial evaporation and condensation during self -pressurization and jet-mixing pressure control in microgravity for a two-component system. Materials & Methods In this work, we will describe the detailed features of the ZBOT-NC experimental hardware and Diagnostics that includes nonintrusive Quantum Dot Thermometry (QDT) for whole field temperature measurement. All microgravity pressurization and pressure control tests will be performed for both the pure and the two-components systems with Xenon and Neon as the two noncondensable gases spanning small and large molecular weights and sizes. The two-phase CFD model that is developed as part of the project will be also presented and discussed. Results Ground-based pressurization and jet mixing experiments and CFD simulation results are compared to each other to validate both the fidelity of the CFD model predictions and the accuracy of the QDT measurement. Model simulations for noncondensable gas effects will also be compared against large Cryogenic LH2-GHe experiments to indicate the noncondensable gas effects on tank pressure control during jet mixing in 1G. Finally, CFD results will be presented to predict the effects of the noncondensable gas during subcooled jet mixing during the ZBOT-NC in advance of the microgravity experiment in 2015.

Evaporation Condensation↗

Nodal Modeling of Liquid Propellant Feed and Pressurization System

Nodal or network flow modeling plays an important role in the design and operation of the feed and pressurization system of a liquid rocket engine. Model development and execution time is relatively short for nodal codes in comparison to the Navier-Stokes based CFD codes. Nodal models also allow the inclusion of several components into one model to predict the behavior of a larger system. Unlike CFD models, the nodal models do not need very fine discretization of the flow field because they use empirical correlations to model fluid friction and heat transfer. This paper presents several applications of nodal modeling of liquid propellant feed and pressurization systems using the Generalized Fluid System Simulation Program (GFSSP), a nodal code developed at NASA/ Marshall Space Flight Center. GFSSP discretizes the flow field into nodes which are connected by branches. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The momentum equations are solved at the branches to calculate flow rates. Applications include a) tank pressurization by inert gas as well as autogenous pressurization by gaseous propellant, b) submerged pressurization by helium, c) self-pressurization due to boil-off of cryogenic propellant, d) chilldown of a transfer line of a cryogenic propellant feed system, and e) chilldown and filling of a cryogenic tank. Each of the above-mentioned models was verified and validated by comparing with test data.

Nodal Model↗

Nodal Modeling of Liquid Propellant Feed and Pressurization System

Nodal or network flow modeling plays an important role in the design and operation of the feed and pressurization system of a liquid rocket engine. Model development and execution time is relatively short for nodal codes in comparison to the Navier-Stokes based CFD codes. Nodal models also allow the inclusion of several components into one model to predict the behavior of a larger system. Unlike CFD models, the nodal models do not need very fine discretization of the flow field because they use empirical correlations to model fluid friction and heat transfer. This paper presents several applications of nodal modeling of liquid propellant feed and pressurization systems using the Generalized Fluid System Simulation Program (GFSSP), a nodal code developed at NASA/ Marshall Space Flight Center. GFSSP discretizes the flow field into nodes which are connected by branches. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The momentum equations are solved at the branches to calculate flow rates. Applications include a) tank pressurization by inert gas as well as autogenous pressurization by gaseous propellant, b) submerged pressurization by helium, c) self-pressurization due to boil-off of cryogenic propellant, d) chilldown of a transfer line of a cryogenic propellant feed system, and e) chilldown and filling of a cryogenic tank. Each of the above-mentioned models was verified and validated by comparing with test data.

Nodal Model↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗