Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Smart Grid Integrity Attacks: Characterizations and Countermeasures

Real power injections at loads and generators, and real power flows on selected lines in a transmission network are monitored, transmitted over a SCADA network to the system operator, and used in state estimation algorithms to make dispatch, re-balance and other energy management system [EMS] decisions. Coordinated cyber attacks of power meter readings can be arranged to be undetectable by any bad data detection algorithm. These unobservable attacks present a serious threat to grid operations. Of particular interest are sparse attacks that involve the compromise of a modest number of meter readings. An efficient algorithm to find all unobservable attacks [under standard DC load flow approximations] involving the compromise of exactly two power injection meters and an arbitrary number of power meters on lines is presented. This requires O(n2m) flops for a power system with n buses and m line meters. If all lines are metered, there exist canonical forms that characterize all 3, 4, and 5-sparse unobservable attacks. These can be quickly detected in power systems using standard graph algorithms. Known secure phase measurement units [PMUs] can be used as countermeasures against an arbitrary collection of cyber attacks. Finding the minimum number of necessary PMUs is NP-hard. It is shown that p + 1 PMUs at carefully chosen buses are sufficient to neutralize a collection of p cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Attack Surface of Wind Energy Technologies in the United States

Low cost, reliable electrical energy production from wind relies upon automation and control systems, arguably more so than traditional thermal generation. These same systems, however, can serve as the target of adversaries’ cyber-attacks. Idaho National Laboratory (INL), at the request of the Department of Energy’s (DOE’s) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) and Energy Efficiency and Renewable Energy’s (EERE’s) Wind Energy Technologies Office (WETO), evaluated a generalized wind plant architecture to understand the classes of potential threat actors and the vectors that could enable a cyber-attack. This evaluation explores the attack surface of a representative wind plant, identifying potential methods and vectors that an adversary could leverage to conduct a cyber-attack. Included in this assessment are some recommended mitigations and approaches. Each recommendation requires a full security evaluation, cost/benefit analysis, and risk analysis by each owner and operator.

17 WIND ENERGY↗

Ransomware Security Threat Modeling for Photovoltaic Systems

Ransomware attacks are one of the most dangerous cyber-attacks which can disrupt the operation of photovoltaic (PV) systems and incur an enormous economic loss. This paper introduces a ransomware security threat modeling method that identifies potential vulnerabilities, threats, and impacts of ransomware attacks targeting a PV system. Here, the security threat modeling consists of three steps: 1) system identification, 2) threat modeling that finds existing vulnerabilities, 3) attack modeling that designs attack profiles to succeed ransomware attacks, and 4) penetration testing that performs authorized cyber-attacks and analyzes impacts of the ransomware attack profiles using a real-time hardware-in-the-loop (HIL) PV system security testbed.

attack modeling↗

Precursor Analysis Report: JBS Foods Ransomware Attack 2021

The JBS Foods 2021 Ransomware Attack Precursor Analysis Report leverages publicly available information about the JBS ransomware cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. In late May 2021, one of the world’s largest meat producers, JBS Foods, announced they had fallen victim to a worldwide ransomware attack, later found to be REvil ransomware. In the United States alone, JBS Foods accounts for nearly 25% of beef and roughly 20% of pork production. Adversaries initially launched a Distributed Denial of Service (DDoS) attack on the company’s Information Technology (IT) networks in Australia, but the attack impacted operations in Brazil, Canada, and the United States, as well. The attack caused plant operations in all four countries to shut down for at least one day. All nine of the U.S. meatpacking plants temporarily shut down because of the attack. The adversaries initially demanded a $\$$22 million ransom for the company’s data, but later negotiated the ransom down to $\$$11 million even after JBS Foods restored most of their systems. JBS Foods eventually paid the $\$$11 Million for reassurance from the adversaries that none of their customers’ data would be compromised in the future. Despite its short duration, the attack still caused large stocks of meat to spoil. The incident also underscored how adversaries can simultaneously compromise and move laterally through global subsidiaries of an organization. Researchers and analysts identified 22 unique techniques (in a sequence of 21 steps) utilized during the attack with a total of 361 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Sixteen of the identified techniques used during the JBS Foods cyber attack were precursors to the triggering event. Analysis identified 308 observables associated with these precursor techniques, 163 of which were assessed to have an increased likelihood of being perceived in the 75 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Data-driven Cyberattack Detection for Photovoltaic (PV) Systems through Analyzing Micro-PMU Data

With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.

14 SOLAR ENERGY↗

Evaluation of Joint Cyber/Safety Risk in Nuclear Power Systems

This report presents an analysis of the Emergency Core Cooling System (ECCS) for a generic Boiling Water Reactor (BWR)-4 NPP. The Electric Power Research Institute (EPRI) developed Hazards and Consequences Analysis for Digital Systems (HAZCADS) process is applied to the ECCS and its subsystems to identify unsafe control actions (UCAs) which act as possible cyber events of concern. The analysis is performed for two design basis events: Small-break Loss of Coolant Accident (SLOCA) and general transients (TRANS), such as unintended reactor trip. In previous work, HAZCADS UCAs were combined with other cyber-attack analysis to develop a risk-informed approach; however, this was for a single system. This report explores advanced systems engineering modeling approaches to model the interactions between digital assets across multiple systems which may be targeted by cyber adversaries. The complex and interdependent design of digital systems has the potential to introduce emergent cyber properties that are generally not covered by hazard analyses nor formal nuclear Probabilistic Risk Assessment (PRA). The R&D and supporting analysis presented here explores approaches to predict and manage how interdependent system properties effect risk. To show the potential impact of a successful cyber-attack to formal PRA event tree probabilities, HAZCADS analysis was also used. HAZCADS was also used to model the automatic depressurization system (ADS) automatic actuation. This analysis extended to an integrated system analysis for common-cause failure (CCF). In this aspect, the HAZCADS analysis continued by analyzing plant design details for system connectivity in support of critical plant functions. A dependency matrix was developed to depict the integrated functionality of the interconnected systems. Areas of potential CCF are indicated. Future work could include adversary attack development to show how CCF could be caused, resulting in PRA events. Across the multiple systems that comprise the ECCS, the analysis shows that the change in such probabilities was very different between systems. This indicates that some systems have a larger potential risk impact from successful cyber-attack or digital failure, which indicates a need for these systems to have a higher priority for design and defensive measures. Furthermore, we were able to establish that a risk analysis using any arbitrary threat model establishes an ordering of components with regard to cyber-risk. This ordering can be used to influence the overall system design with an eye to lowering risk, or as a way to understand real-time risk to operational systems based on a current threat landscape. Expert knowledge of both the analysis process and the system being analyzed is required to perform a HAZCADS analysis. The need for a tiered risk analysis is demonstrated by the results of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model-Based Diagnostics and Mitigation of Cyber Threats

The report summarizes key tasks performed to develop a toolkit for detecting cyber-attack events in instrumentation and control (I&C) systems of nuclear power plants. The toolkit connects the state-of-the-art GPWR Simulator with the RELAP5 code providing best-estimate nuclear steam supply system (NSSS) analyses, via the application programming interface (API), and allows users to introduce potential cyber-attack scenarios into power plant operational simulation. This summary for the project reflects topical reports submitted during the project as well as a journal paper published in 2022. The focus areas of the summary include: (1) modeling I&C systems for the AP1000 Generation III+ nuclear plant and GPWR simulator, (2) simulation and monitoring of plant response to cyber-attack events, (3) API structure for the toolkit interfacing the GPWR simulator and RELAP5 code, and (4) restructuring of the three-loop NSSS software of GPWR to model the two-loop AP1000 structure. Discussed in some details are (a) the attack tree analysis assessing the susceptibility of the AP1000 I&C system, resulting in reactor trips, in terms of the attack possibility and component sensitivity and (b) realistic estimation of the time to steam generator trip due to cyber-intrusions in the GPWR Simulator. Finally, sample demonstrations of the cyber-security tool kit, in the form of the GPWR-RELAP5 API, are summarized.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Mathematical Framework for the Analysis of Cyber-Resilient Control Systems

The increasingly recognized vulnerability of industrial control systems to cyber-attacks has inspired a considerable amount of research into techniques for cyber-resilient control systems. The majority of this effort involves the application of well known information security (IT) techniques to control system networks. While these efforts are important to protect the control systems that operate critical infrastructure, they are never perfectly effective. Little research has focused on the design of closed-loop dynamics that are resilient to cyber-attack. The majority of control system protection measures are concerned with how to prevent unauthorized access and protect data integrity. We believe that the ability to analyze how an attacker can effect the closed loop dynamics of a control system configuration once they have access is just as important to the overall security of a control system. To begin to analyze this problem, consistent mathematical definitions of concepts within resilient control need to be established so that a mathematical analysis of the vulnerabilities and resiliencies of a particular control system design methodology and configuration can be made. In this paper, we propose rigorous definitions for state awareness, operational normalcy, and resiliency as they relate to control systems. We will also discuss some mathematical consequences that arise from the proposed definitions. The goal is to begin to develop a mathematical framework and testable conditions for resiliency that can be used to build a sound theoretical foundation for resilient control research.

Control Theory↗

Robust Model Predictive Control for Attack Mitigation of Virtual Synchronous Generators (VSGs) in an Islanded Microgrid

With the increasing application of power converters in distributed energy systems, power electronics converters face an increasing number of cyber-attacks. To mitigate the cyber-attack impact on voltage source converters (VSCs) and microgrids, a robust model predictive control (RMPC) is proposed for virtual synchronous generators (VSG) in an islanded microgrid. This RMPC is designed to compensate for the frequency deviations, thus maintaining frequency stability of the whole islanded microgrid against cyber threats. Finally, to verify the feasibility of the proposed method, comparisons between the proposed method and the conventional VSC controller are provided in different attack scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment

The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: Blackmatter Ransomware Attack on New Cooperative 2021

The BlackMatter Ransomware Attack on New Cooperative 2021 Precursor Analysis Report leverages publicly available information about the New Cooperative cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. The BlackMatter ransomware was first identified in July 2021 and is reported to have infected more than 50 corporations around the world. , The Iowa-based grain cooperative, New Cooperative, was impacted by the BlackMatter ransomware on or before 18 September 2021. The adversary likely resided on New Cooperative’s networks for 15 days prior to encrypting its network and demanding New Cooperative pay $5.9 million in ransom by 25 September to unlock systems and prevent 1 terabyte (TB) of sensitive data from being publicly released. It is not clear if New Cooperative paid the ransom. The full impact of the ransomware attack is not known; however, according to New Cooperative’s general manager, the attack caused the company’s automated processes to revert back to processes used in the 1970s. , As of 6 October, only 50 percent of New Cooperative’s operations were utilizing automated processes. The company took eight weeks to rebuild the entire network and information technology (IT) systems from the ground up, which puts the date of fully recovery around 13 November. Researchers and analysts identified 20 unique techniques utilized during the attack with a total of 404 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Seventeen of the identified techniques used during the New Cooperative cyber attack were precursors to the triggering event. Analysis identified 360 observables associated with these precursor techniques, 284 of which were assessed to have an increased likelihood of being perceived in the 15 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

PMU and Communication Infrastructure Restoration for Post-Attack Observability Recovery of Power Grids

This paper is concerned about recovering the observability of cyber-physical power grids after massive cyber attacks, which helps to achieve the cyber-physical resilience of the grids. For recovering the observability of the grid, the measurability of the Phasor Measurement Units (PMUs) and the connectivity of the communication network are needed to be restored. The PMU and communication infrastructure restoration problem is jointly formulated as a Mixed Integer Linear Programming (MILP) problem to minimize the observability loss of the grid over time after a cyber attack while considering the constraint of limited resources. The efficacy of the proposed optimal restoration strategy is verified by comparing with heuristic methods on the IEEE 57-bus system.

cyber security↗

Cybersecurity Awareness in the Power Grid

We report on a series of interviews and observations conducted with control room dispatchers in a bulk electrical system. These dispatchers must react quickly to incidents as they happen in order to ensure the reliability and safe operation of the power grid. They do not have the time to evaluate incidents for signs of cyber-attack as part of their initial response. Cyber-attack detection involves multiple personnel from a variety of roles at both local and regional levels. Smart grid technology will improve detection and defense capabilities of the future grid, however, the current infrastructure remains a mixture of old and new equipment which will continue to operate for some time. Thus, research still needs to focus on strategies for the detection of malicious activity on current infrastructure as well as protection and remediation.

Scholtz, Jean↗

Cybersecurity of Wide Area Monitoring, Protection and Control Systems for HVDC Applications

The flexibility provided by High Voltage Direct Current (HVDC) systems can be further extended by Wide Area Monitoring, Protection, and Control (WAMAPC) systems. WAMPAC systems enable many HVDC applications and, on the other hand, inevitably introduce cybersecurity concerns that need to be addressed. In this work, a security domain layer and decision framework is reported to detect and mitigate the impact of false data injection (FDI) attacks targeting HVDC stations. Specifically, a rule-based cyber-attack detection method is introduced and implemented on Raspberry Pi and tested on the real-time HVDC simulation facility on the real-time digital simulator (RTDS) platform at ABB U.S. Corporate Research Center.

cybersecurity↗

Precursor Analysis Report: Remote Access Attack on Oldsmar Water Treatment Facility 2021

The Remote Access Attack on Oldsmar Water Treatment Facility 2021 Precursor Analysis Report leverages publicly available information about the Oldsmar cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 5 February 2021, an adversary gained unauthorized remote access to Bruce T. Haddock Water Treatment Plant in Oldsmar, Florida, which provides treated water to 15,000 customers. The adversary accessed the facility’s Supervisory Control and Data Acquisition (SCADA) workstation and human machine interface (HMI) to change the chemical concentration of sodium hydroxide, commonly referred to as lye and used to regulate acidity levels, from 100 parts per million (PPM) to 11,100 PPM. The chemical was raised to lethal levels that if ingested could lead to serious soft tissue damage, burns, or even death. The facility, however, had redundancies and alarms in place to alert personnel of dangerous chemical levels, and facility officials stated it would have taken 24 to 36 hours for the chemical changes to affect the water supply. Researchers and analysts identified six unique techniques utilized during the attack with a total of 23 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Four of the identified techniques used during the Oldsmar cyber attack were precursors to the triggering event. Analysis identified 21 observables associated with these precursor techniques, 20 of which were assessed to have an increased likelihood of being perceived in the minutes preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: Ryuk Ransomware Attack on Universal Health Services 2020

The Ryuk Ransomware Attack on Universal Health Services (UHS) 2020 Precursor Analysis Report leverages publicly available information about the 2020 UHS cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. UHS manages over 400 hospitals and is one of the largest healthcare providers in the United States with 3.5 million patients each year. On 27 September 2020, UHS suffered a widespread ransomware attack that resulted in a denial of service to critical internet-dependent healthcare systems including workstations, phones, and data centers. Employees resorted to filing patient details with pen and paper, while other facilities had to redirect ambulances and urgent patients to other facilities for adequate care. Adversaries carried out the attack with Ryuk, a ransomware that encrypts data and generates a RyukReadMe.txt ransom note with the ransom fee to decrypt the data, varying from 15 Bitcoin (BTC) to 50 BTC, equivalent to roughly $\$$353,892 to $\$$964,617. UHS did not pay the ransom and was able to recover data through backups, but still reported an impact of $\$$67 million dollars in recovery costs. On 29 October, one month after the attack, UHS made an official statement that their systems had been restored and they were resuming normal operations. Researchers and analysts identified 18 unique techniques (used in a sequence of 19 steps) utilized during the attack with a total of 185 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fourteen of the identified techniques used during the UHS cyber attack were precursors to the triggering event. Analysis identified 106 observables associated with these precursor techniques, 82 of which were assessed to have an increased likelihood of being perceived in the 30 days to two hours preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implementation of an ICS Ransomware Testbed: Scenarios, Variants, and Evaluation Methods

Ransomware attacks on Industrial Control Systems (ICS) have emerged as a formidable threat to the United States’ critical infrastructure, eliciting grave concerns regarding national security. In March 2023, the FBI Internet Crime Complaint Center (IC3) unveiled its 2022 Internet Crime Report, highlighting a concerning 870 complaints related to ransomware impacting U.S. critical infrastructure. Of the country's 16 critical infrastructure sectors, 14 encountered at least one ransomware attack. Notably, while the Healthcare and Public Health sector suffered the most, reporting 210 attacks, sectors pivotal to ICS networks and governmental organizations were also targeted: the Defense Industrial Base reported 1 attack, Water and Wastewater Systems 3, Chemical 19, Energy 15, Government Facilities 115, and Critical Manufacturing 157. For instance, a ransomware attack on a major chemical company could jeopardize not only its production but also pose environmental risks should systems controlling hazardous materials be compromised. In 2022, three ransomware variants predominantly targeted U.S. critical infrastructure: HIVE, with 87 attacks; ALPHV/BlackCat, with 114; and LOCKBIT, with 149. Several cyber-attacks, such as the MOVEit data breach in May 2023 and the Colonial Pipeline ransomware attack in May 2021, have been so impactful that they commanded national attention. The DarkSide hacking group's assault on the Colonial Pipeline, initiated on May 6th, 2021, stands as one of the most substantial and publicly acknowledged cyber-attacks against U.S. critical infrastructure. The group exploited an exposed Virtual Private Network (VPN) password, paving the way for initial intrusion and subsequent data theft. A mere day later, DarkSide unleashed a ransomware attack that compromised vital accounting and billing systems, prompting an immediate shutdown of the pipeline to mitigate further ransomware proliferation across its network. This crisis spurred a robust response from the U.S. president and regulators, culminating in a national emergency declaration related to the pipeline shutdown on May 9th, 2021. This incident mirrors the 2017 NotPetya ransomware attack that significantly impacted the shipping giant Maersk, highlighting an urgent need for fortified cybersecurity across various industries. Future incidents, akin to the Colonial Pipeline attack, could potentially be mitigated—or entirely averted—should government agencies and private entities scrutinize system vulnerabilities, exploring various ransomware types and entry points. Proactive measures, such as conducting experiments on VPN accounts or auditing passwords to pinpoint duplicate usage across diverse systems and software, might illuminate feasible entry points and vulnerability zones within an organization's systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗