Search NASA⌕ Search

SEARCH · Search NASA

Results for “data communication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Immersive Scientific Visualization of Molten-Salt Reactor Waste Characteristics Using Virtual Reality

Immersive visualization is changing how we explore, communicate, and understand complex scientific systems. In nuclear energy, an area in which data are often multidimensional, time-dependent, and difficult to interpret, virtual reality (VR) represents a powerful and intuitive informational medium. This work introduces a VR-based platform that visualizes the post-shutdown behavior and waste management lifecycle of molten-salt reactors (MSRs), a next-generation reactor type with unique operational and safety characteristics. The platform, built in Unity, is streamed on the Meta Quest 3 headset. It transforms high-fidelity simulation data into an interactive, immersive experience. Users can explore time-dependent reactor characteristics such as nuclide decay, which is a key factor for evaluating reactor waste strategies. The datasets were generated using the MOOSE (Multiphysics Object-Oriented Simulation Environment) framework and then processed through ParaView scripting for smooth integration into Unity. From a visualization standpoint, the platform emphasizes spatial storytelling, temporal exploration, and user-centered interaction. Users can navigate 3D reactor geometries, slice through volumetric data, and manipulate time to observe how physical phenomena evolve. Real-scale rendering and embodied interaction make the experience feel tangible. The interface is designed to be accessible, even to those without nuclear or simulation expertise. This lowers the barrier for stakeholders, policymakers, and the general public, while still supporting expert analysis and collaborative decision-making. This work shows how immersive visualization can function as both a scientific tool and a communication interface. By integrating simulation, processing, and visualization into a cohesive workflow, we offer a scalable framework for immersive scientific storytelling. The modular design supports future extensions to other reactor types and lifecycle stages, from shutdown to long-term storage, making the platform adaptable for both research and outreach.

99 - GENERAL AND MISCELLANEOUS↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Characterizing Interaction Uncertainty in Human-Machine Teams

With the increasing use and adoption of artificial intelligence (AI), the reliability of modern data systems will be driven by a tighter teaming between human experts and intelligent machine teammates. As in the case of human-human teams, the success of human-machine teams will also rely on clear communication about mutual goals and actions. In this paper, we combine related literature from cognitive psychology, human-machine teaming, uncertainty in data analysis, and multi-agent systems to propose a new form of uncertainty: interaction uncertainty for characterizing bidirectional communication in human-machine teams. We map the causes and effects of interaction uncertainty and outline potential ways to mitigate uncertainty for mutual trust in a high-consequence real-world scenario.

uncertainty, data analytics, interaction, trust, h↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predictive Model for Starlink Maritime Performance Using Multi-Horizon RandomForest

Low Earth orbit (LEO) satellite systems have become a crucial enabler of broadband access for maritime industries, where traditional networks are unavailable. However, the high mobility of LEO constellations and constantly changing weather conditions result in unpredictable link fluctuations, limiting the ability of maritime platforms to plan bandwidth usage proactively. To the best of our knowledge, no prior work has developed a short-term predictive model for maritime LEO connectivity using real experimental field measurements. This paper proposes a data-driven forecasting model that predicts future downlink throughput using multi-horizon RandomForest regression. The model is trained using real experimental coastal measurement data incorporating recent throughput history, network-layer indicators, and environmental variables. The proposed approach reduces mean absolute error by approximately 31% compared to a persistence baseline for 15-minute horizons. It maintains a measurable improvement at 30 minutes, despite increased stochasticity. These findings confirm that proactive bandwidth awareness is feasible on maritime platforms and can effectively support operational decisions such as adaptive streaming, routing, and resource scheduling. The performance gap between forecasting horizons also highlights the need for expanded offshore datasets to improve prediction robustness under harsher maritime environments.

97 MATHEMATICS AND COMPUTING↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Persistent DynAMICS

Persistent DynAMICS is a lightweight software platform that enables distributed sensing systems to operate as a unified, responsive network. It integrates with existing sensors, data systems, and processing tools as an overlay, without requiring hardware replacement or increasing user burden. As data is collected, the system identifies situations that require additional attention and directs selected sensors to gather more information. For example, if a sensor detects an unusual condition along a pipeline, the system can task nearby sensors or different sensing modalities to confirm the event and focus data collection where it is needed. To support this, the platform forms temporary groups of sensors that work together to address specific objectives. Once complete, these groups are dissolved and resources are reassigned as needed. Communication is handled through an integrated messaging framework with client and server components, enabling reliable operation and data continuity even in low-bandwidth or intermittent connectivity environments.

97 MATHEMATICS AND COMPUTING↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A multigigabit link layer protocol for single picosecond latency determinism using AMD ultrascale+ GTH and GTY transreceivers

recision timing distribution systems require determin istic and repeatable high speed serial data link latency. The EIC Timing Data Link will employ a specialized link layer protocol for deterministic multigigabit communication us ing AMD Ultrascale+ GTH and GTY transceivers. Link la tency must also be measurable to accurately compensate in real time for latency variations of the physical medium. The point-to-point link is full duplex and fully synchronous with a latency control algorithm to align the internal clocks of each system with picosecond resolution. Deterministic clock domain crossing between systems is ensured using static timing analysis of the elastic buffer control signals.

43 PARTICLE ACCELERATORS↗

Predictive Modeling and Operational Monitoring of Starlink Leo Satellite Network Performance in Maritime Environments

This thesis investigates short-term performance prediction for maritime LEO operational planning and application performance cannot anticipate available bandwidth or communication delay, which complicates variation alter signal conditions over short time scales. As a result, maritime users often fluctuations in link quality. In addition, Frequent satellite handoffs and Doppler-induced rapid satellite movement and changing atmospheric conditions cause substantial unavailable. Despite their availability, reliable operation at sea remains difficult because broadband connectivity in maritime regions where terrestrial infrastructure in

97 MATHEMATICS AND COMPUTING↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

GPU-enabled extreme-scale turbulence simulations: Fourier pseudo-spectral algorithms at the exascale using OpenMP offloading

Fourier pseudo-spectral methods for nonlinear partial differential equations are of wide interest in many areas of advanced computational science, including direct numerical simulation of three-dimensional (3-D) turbulence governed by the Navier-Stokes equations in fluid dynamics. This paper presents a new capability for simulating turbulence at a new record resolution up to 35 trillion grid points, on the world's first exascale computer, Frontier, comprising AMD MI250x GPUs with HPE's Slingshot interconnect and operated by the US Department of Energy's Oak Ridge Leadership Computing Facility (OLCF). Key programming strategies designed to take maximum advantage of the machine architecture involve performing almost all computations on the GPU which has the same memory capacity as the CPU, performing all-to-all communication among sets of parallel processes directly on the GPU, and targeting GPUs efficiently using OpenMP offloading for intensive number-crunching including 1-D Fast Fourier Transforms (FFT) performed using AMD ROCm library calls. With 99% of computing power on Frontier being on the GPU, leaving the CPU idle leads to a net performance gain via avoiding the overhead of data movement between host and device except when needed for some I/O purposes. Memory footprint including the size of communication buffers for MPI_ALLTOALL is managed carefully to maximize the largest problem size possible for a given node count. Detailed performance data including separate contributions from different categories of operations to the elapsed wall time per step are reported for five grid resolutions, from 2048 3 on a single node to 32768 3 on 4096 or 8192 nodes out of 9408 on the system. Both 1D and 2D domain decompositions which divide a 3D periodic domain into slabs and pencils respectively are implemented. The present code suite (labeled by the acronym GESTS, GPUs for Extreme Scale Turbulence Simulations) achieves a figure of merit (in grid points per second) exceeding goals set in the Center for Accelerated Application Readiness (CAAR) program for Frontier. The performance attained is highly favorable in both weak scaling and strong scaling, with notable departures only for 2048 3 where communication is entirely intra-node, and for 32768 3 , where a challenge due to small message sizes does arise. Communication performance is addressed further using a lightweight test code that performs all-to-all communication in a manner matching the full turbulence simulation code. Performance at large problem sizes is affected by both small message size due to high node counts as well as dragonfly network topology features on the machine, but is consistent with official expectations of sustained performance on Frontier. Overall, although not perfect, the scalability achieved at the extreme problem size of 32768 3 (and up to 8192 nodes — which corresponds to hardware rated at just under 1 exaflop/sec of theoretical peak computational performance) is arguably better than the scalability observed using prior state-of-the-art algorithms on Frontier's predecessor machine (Summit) at OLCF. New science results for the study of intermittency in turbulence enabled by this code and its extensions are to be reported separately in the near future.

3D fast Fourier transform↗

Nuclear Criticality Safety Margin and Handbook Data: Concepts and Applications [Slides]

At the end of this briefing, personnel should be able to: • Define concepts associated with criticality safety margin • Provide and understand practical applications that illustrate safety margin concepts • Describe how safety margin is addressed in criticality safety evaluations • Improve documentation and communication of safety margin • Connect these concepts to related statements in the ANS-8 Standards • Find numerous applications for handbook data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Yield Estimates of three Historical Atmospheric Nuclear Explosions at Lop Nor, from Reduced Order Models of Regionally Recorded Rayleigh Waveforms and One Seismic Station: A Brief Communication

We use a reduced order model (ROM) for Rayleigh waveforms sourced by large atmospheric explosions along with data collected from a single seismic station (TLG) to estimate the yields of three atmospheric nuclear tests with order-megaton (MT) yields. These historical tests were conducted by China between 1973 and 1980 (CHIC 15, CHIC 16, and CHIC 26). We use our ROM to estimate yields of 2.34 MT (CHIC 15), 0.51 MT (CHIC 16), and 1.15 (CHIC 26) in the 20.5 s period band that are consistent with publicly accepted values of 3 MT (CHIC 15), 0.50 MT (CHIC 16), and 0.730 MT (CHIC 26).

58 GEOSCIENCES↗

A Grassroots Network and Community Roadmap for Interconnected Autonomous Science Laboratories for Accelerated Discovery

Scientific discovery is being revolutionized by AI and autonomous systems, yet current autonomous laboratories remain isolated islands unable to collaborate across institutions. We present the Autonomous Interconnected Science Lab Ecosystem (AISLE), a grassroots network transforming fragmented capabilities into a unified system that shorten the path from ideation to innovation to impact and accelerates discovery from decades to months. AISLE addresses five critical dimensions: (1) cross-institutional equipment orchestration, (2) intelligent data management with FAIR compliance, (3) AI-agent driven orchestration grounded in scientific principles, (4) interoperable agent communication interfaces, and (5) AI/ML-integrated scientific education. By connecting autonomous agents across institutional boundaries, autonomous science can unlock research spaces inaccessible to traditional approaches while democratizing cutting-edge technologies. This paradigm shift toward collaborative autonomous science promises breakthroughs in sustainable energy, materials development, and public health.

Ferreira da Silva, Rafael [Oak Ridge National Labo↗