Search NASA⌕ Search

SEARCH · Search NASA

Results for “data integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Integrating Data From In Vitro New Approach Methodologies for Developmental Neurotoxicity

Abstract In vivo developmental neurotoxicity (DNT) testing is resource intensive and lacks information on cellular processes affected by chemicals. To address this, DNT new approach methodologies (NAMs) are being evaluated, including: the microelectrode array neuronal network formation assay; and high-content imaging to evaluate proliferation, apoptosis, neurite outgrowth, and synaptogenesis. This work addresses 3 hypotheses: (1) a broad screening battery provides a sensitive marker of DNT bioactivity; (2) selective bioactivity (occurring at noncytotoxic concentrations) may indicate functional processes disrupted; and, (3) a subset of endpoints may optimally classify chemicals with in vivo evidence for DNT. The dataset was comprised of 92 chemicals screened in all 57 assay endpoints sourced from publicly available data, including a set of DNT NAM evaluation chemicals with putative positives (53) and negatives (13). The DNT NAM battery provides a sensitive marker of DNT bioactivity, particularly in cytotoxicity and network connectivity parameters. Hierarchical clustering suggested potency (including cytotoxicity) was important for classifying positive chemicals with high sensitivity (93%) but failed to distinguish patterns of disrupted functional processes. In contrast, clustering of selective values revealed informative patterns of differential activity but demonstrated lower sensitivity (74%). The false negatives were associated with several limitations, such as the maximal concentration tested or gaps in the biology captured by the current battery. This work demonstrates that this multi-dimensional assay suite provides a sensitive biomarker for DNT bioactivity, with selective activity providing possible insight into specific functional processes affected by chemical exposure and a basis for further research.

Carstens, Kelly E.↗

CAPTAN: A hardware architecture for integrated data acquisition, control, and analysis for detector development

The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory has developed a data acquisition system flexible and powerful enough to meet the needs of a variety of high energy physics applications. The system described in this paper is called CAPTAN (Compact And Programmable daTa Acquisition Node) and its architecture and capabilities are presented in detail here. The three most important characteristics of this system are flexibility, versatility and scalability. These three main features are supported by key architectural features; a vertical bus that permits the user to stack multiple boards, a gigabit Ethernet link that permits high speed communications to the system and the core group of boards that provide specific capabilities for the system. In this paper, we describe the system architecture, give an overview of its capabilities and point out possible applications.

99 GENERAL AND MISCELLANEOUS↗

Integrated Data Collection Analysis (IDCA) Program — Quarterly Review Meeting

On November 9 and 10, 2011 the IDCA had the annual quarterly meeting. The meeting started the afternoon of the first day with a tour of the NSWC IHD explosives safety testing and analysis facilities. The meeting on the second day addressed the formal sponsor review and further technical issues for the IDCA. Examination of the IHD equipment during the tour, lead to a long discussion on liquid test methods. The discussion resulted in revision of liquid test methods in the impact test and selection of a new liquid test standard. In addition, modifications to friction, spark and thermal test methods were discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — IDCA Quarterly Program Review, September 14 and 15, 2010

The IDCA conducted a program review at Los Alamos National Laboratory, September 14 and 15, 2010. The review was divided into three parts: 1) an update on the current status of the program, 2) an information exchange and discussion on technical details for current issues and future planning, and 3) a tour of the SSST testing facilities at LANL. The meeting started with an update from DHS by Laura Parker and a restating of some of the objectives of the Proficiency Test of which the IDCA is currently engaged. This update was followed by a discussion of some high level programmatic issues particularly about ways of communicating the overall goals of the IDCA to non-technical representatives. The final topic focused on the difficulty of releasing information, including the DHS approval process, ITAR, and open publication. Next JGR presented a technical summary of accomplishments, schedule, milestones, and future directions. These key points made were: 1) about 1/3 of the materials have been tested, 2) some participants are behind others causing a lag in report writing, 3) method reports have been assigned to various participants to speed up the process of reporting, 4) the SSST Compendium needs reformatting and restructuring, and 5) the Compendium needs a web site to house with access control. After the technical update, some of the Proficiency Test results were shown comparing data from the various laboratories. These results included comparisons of the RDX standard, KC/sugar mixtures (-100 mesh and as received), KC/dodecane, KP/Al, and KP/C. Impact, friction, ESD, and DSC results were the focus. All the participants were involved in these discussions. This report includes summary notes, presentations, and explanatory information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - Mixing Procedures and Materials Compatibility

Three mixing procedures have been standardized for the IDCA proficiency test—solid-solid, solid-liquid, and liquid-liquid. Due to the variety of precursors used in formulating the materials for the test, these three mixing methods have been designed to address all combinations of materials. Hand mixing is recommended for quantities less than 10 grams and Jar Mill mixing is recommended for quantities over 10 grams. Consideration must also be given to the type of container used for the mixing due to the wide range of chemical reactivity of the precursors and mixtures. Eight web site sources from container and chemical manufacturers have been consulted. Compatible materials have been compiled as a resource for selecting containers made of materials stable to the mixtures. In addition, container materials used in practice by the participating laboratories are discussed. Consulting chemical compatibility tables is highly recommended for each operation by each individual engaged in testing the materials in this proficiency test.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program: FY2011 Project Descriptions

This document provides brief descriptions of research topics for consideration by the IDCA for potential funding in funding in FY 2011. The topics include the utilization of the results from the Proficiency Test developed during FY 2010 to start populating the small-scale safety and thermal testing (SSST) Testing Compendium and revising results from methods modifications. Other research topics were also developed for FY 2011 from issues that arose in the Proficiency Test.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrating Data Sources for Improved Safeguards and Accountancy of Electrochemical Fuel Reprocessing Systems. Final Report

Electrochemical reprocessing (also commonly known as “pyroprocessing”) of used nuclear fuel is an alternative to aqueous reprocessing that confers a number of advantages, including the ability to process more recently-discharged fuel, smaller resultant waste volumes, and the lack of isolation of plutonium in the product stream. While electrochemical reprocessing systems have seen a significant research and development effort, nuclear safeguards and security of these systems remains under-developed, particularly given the significant differences in operating environment and process flowsheet compared with established aqueous methods. Objective 4 of DOE’s nuclear energy research and development activities in Nuclear Energy Research and Development Roadmap is: “Understand and minimize the risks of nuclear proliferation and terrorism.” Material Control & Accountancy (MC&A) programs at nuclear processing plants deter and detect theft and diversion of nuclear material by both outside and inside adversaries. Empirical modeling and data analytics of online measurements and state indicators can improve the timeliness of detection and reduce the uncertainty in accountancy measures. To support the development and demonstration of such methods, data are needed that capture expected measurement values collected throughout electrochemical reprocessing facilities. A review of the available literature of current research in measurements for electrochemical reprocessing systems identified twenty-two candidate measurement methodologies, which characterize fuel/salt composition, concentrations of various isotopes and elements, and operational parameters throughout the reprocessing facility. Four primary measurement methodologies have been simulated based on either physical simulations or empirical correlations: gamma emissions, neutron emissions, hybrid k-edge densitometry (HKED), and cyclic voltammetry. Initial investigation into the use of these measures for process monitoring and detection suggests the approach is viable and worthy of further investigation. This report summarizes efforts to generate signatures of key measurements during operation of electrochemical reprocessing facilities and initial investigation of data analytics to support process monitoring, diversion detection, and accountancy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of LVDS Transmission Data Integrity

Differential Signaling, or LVDS, is a physical layer interface that allows forhigh-speed transmission over short distances, and is an efficient alternative to single-ended signaling. Differential signals are robust to common-mode noise, as the equal and opposite signals both incur identical disturbances. LVDS circuits also utilize a constant current, which allows for lower power consumption. LVDS links will be implemented in future neutrino experiments, so developing and testing a proper design is necessary for incoming projects. This presentation will detail the results of the testing of an LVDS implementation that was designed by the ASIC department at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗