Search NASA⌕ Search

SEARCH · Search NASA

Results for “external beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Region Extent Assessment with X-rays (AREA-X)

The development of semiconductor sensors for new particle tracking detectors places increasing limits on sensor characteristics such as uniformity, size and shape of inefficient areas and size of active compared to inactive sensor areas. Accurately assessing these relatively subtle effects requires either measurements in particle beams or the modification of samples to be used in dedicated laser test setups. Active Region Extent Assessment with X-rays (AREA-X) has been developed as an alternative method for the fast, efficient and precise study of the active area of a semiconductor sensor. It uses a monochromatic, micro-focused X-ray beam with a 10–20 keV energy range as provided by several synchrotron beam lines and uses the photo current induced in the sensor to measure the depth of the responsive sensor volume. It can be used to study local inhomogeneities or inefficiencies, the overall extent of the active sensor volume and its shape and its localised application, which makes the need to gather statistics over a large area unnecessary, allowing for fast readout, which enables studies of the sensor behaviour at a range of external parameters, e.g. temperature or applied bias voltage. This paper presents the measurement concept and technical setup of the measurement, results from initial measurements as well as capabilities and limitations of the method.

47 OTHER INSTRUMENTATION↗

Parameters of fast and high-yield InAs/GaAs quantum dot semiconductor scintillator

InAs quantum dots (QDs) embedded into a waveguiding GaAs semiconductor matrix may produce scintillation detectors with exceptional speed and yield, making them valuable for nuclear security, medical imaging, and high energy physics applications. In this work, we developed thick (~25 μm) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. Here, the bulk GaAs acts as a stopping material for incident particles and as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (< 1 cm –1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with an external photodiode (PD) and an integrated PD which provided an improved optical coupling. The mean charge collected by the integrated PD corresponded to 3 × 10 4 photoelectrons per 1 MeV of deposited energy, or ~13% of the theoretically achievable light yield. Combined with the previously measured QD scintillation time of 0.3-0.6 ns, this makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported.

36 MATERIALS SCIENCE↗

Standoff detection of chemical plumes from high explosive open detonations using a swept-wavelength external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser (ECQCL) is used to perform standoff detection of combustion gases in a plume generated from an outdoor high-explosive (HE) open detonation. The swept-ECQCL system was located at a standoff distance of 830 m from a 41kg charge of LX-14(polymer-bonded high explosive) and was used to measure the infrared transmission/absorption through the post-detonation plume as it propagated through the beam path. The swept-ECQCL was operated continuously to record broadband absorption spectra at 200hz rate over a spectral range from 2050 to 2230 cm -1 (4.48 - 4.88 μm). Fitting of measured spectra was used to determine time-resolved column densities of CO, CO 2 , H 2 O, and N 2 O. Analysis of visible video imagery was used to provide timing correlations and to estimate plume dimensions, from which gas mixing ratios were estimated. Measured emission factors and modified combustion efficiency show good agreement with previously reported values.

47 OTHER INSTRUMENTATION↗

Operation of normal-conducting rf cavities in multi-Tesla magnetic fields for muon ionization cooling: A feasibility demonstration

Ionization cooling is the preferred method for producing bright muon beams. This cooling technique requires the operation of normal conducting, radio-frequency (rf) accelerating cavities within the multi-tesla fields of dc solenoid magnets. Under these conditions, cavities exhibit increased susceptibility to rf breakdown, which can damage cooling channel components and imposes limits on channel length and transmission efficiency. We report, for the first time, stable high-vacuum, normal-conducting cavity operation at gradients of 50 MV / m in an external magnetic field of three tesla, through the use of beryllium cavity elements. This eliminates a significant technical risk that has previously been inherent in ionization cooling channel designs.

43 PARTICLE ACCELERATORS↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

A new class of single-phase multiferroics: Bismuth-based layered supercell oxide thin films—Current progress and future perspectives

Multiferroic materials, where ferroelectric and magnetic orders coexist, have ignited substantial research interest due to the achievable manipulation of magnetic orders using external electric fields, a feature that has garnered serious interest for memory storage applications. Nonetheless, naturally occurring single-phase multiferroic materials are scarce, thus constraining options for practical use. Over the last decade, bismuth-based layered supercell (LSC) oxides have emerged as novel candidates for multiferroics, catalyzing extensive investigations in this domain. Additionally, these LSC systems are known for their anisotropic structures and optical properties, making them promising for application in optics such as polarizers, beam splitters, and modulators. This thorough review explores the development and current advancements in multiferroic bismuth-based LSC materials. It covers the diverse nature of LSCs, detailing their microstructure, properties, and the mechanics of self-assembly formation. It also highlights the remarkable multifunctional characteristics of LSC-based nanocomposites, with a particular focus on their applications in electronics and optics. Moreover, this review examines the significant potential of LSCs in practical applications, particularly through their integration onto silicon and flexible substrates via heteroepitaxy and film transfer techniques. Finally, it offers insights into potential future research avenues and the broader implications of these versatile LSC materials.

Materials Science↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

Magnetic field effects on laser energy deposition and filamentation in magneto-inertial fusion relevant plasmas

We report on experimental measurements of how an externally imposed magnetic field affects plasma heating by kJ-class, nanosecond laser pulses. The experiments reported here took place in gas cells analogous to magnetized liner inertial fusion targets. We observed significant changes in laser propagation and energy deposition scale lengths when a 12T external magnetic field was imposed in the gas cell. We find evidence that the axial magnetic field reduces radial electron thermal transport, narrows the width of the heated plasma, and increases the axial plasma length. Reduced thermal conductivity increases radial thermal gradients. This enhances radial hydrodynamic expansion and subsequent thermal self-focusing. Our experiments and supporting 3D simulations in helium demonstrate that magnetization leads to higher thermal gradients, higher peak temperatures, more rapid blast wave development, and beam focusing with an applied field of 12T.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)↗

Resistive contributions to the stability of DIII-D ITER baseline demonstration discharges

Here, measurements of the plasma response to applied n = 1 perturbations from DIII-D ITER baseline scenario (IBS) demonstration discharges exhibit increasing amplitude prior to disruption inducing mode locking events. Simulations reveal that changes in ideal and resistive stability impact the response in the DIII-D IBS regime, well below the pressure limit of the external kink mode. The dependencies of the response measurements on the plasma normalized internal inductance ℓ i and beta β N are qualitatively consistent with ideal MHD, although in most cases the amplitude of the measurements exceeds predictions, indicating that the experimental discharges are less stable than expected. Resistive MHD simulations of the response show improved compatibility with the measurements, and the closest agreement is obtained by including the experimental plasma rotation in the simulations. Although the input neutral beam torque is near zero, the simulations show that the corresponding level of rotation can lead to nearly complete screening of the pitch-resonant field component at the q = 2 surface. However, the simulation results exhibit a significant weakening of this screening effect at the lowest rotation levels in the data set, concurrent with predictions of elevated response amplitudes that are consistent with measurements. These comparisons with DIII-D data provide a qualitative validation of a linear, resistive MHD response model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of spin and magnetism in two dimensional materials with atomic-scale spatial resolution (Final Technical Report)

Spintronics is an approach to energy-efficient electronics beyond silicon CMOS that utilizes the electron’s spin degree of freedom for memory and logic. The record spin diffusion length in graphene has generated considerable interest in two dimensional (2D) materials (i.e. graphene and beyond) as a platform for spintronics. Magnetism in 2D van der Waals materials may offer additional opportunities for tunability via strain, external fields, and layer-dependent quantum effects. The inherently atomic-scale nature of exchange interactions and the inherently all-surface nature of 2D sheets motivate an integrated approach combining atomic-scale magnetic characterization, epitaxial growth, and nanodevice fabrication. The mission of the research is to develop and utilize atomic-scale imaging of spin and magnetism via spin-polarized scanning tunneling microscopy (STM) in conjunction with atom-by-atom materials growth via molecular beam epitaxy (MBE) and nanoscale device fabrication to explore new frontiers of spintronics and quantum science in 2D materials. The PIs are particularly motivated by understanding how the magnetic and spin-dependent properties at the atomic scale lead to interesting and potentially useful phenomena in spintronic devices at the macroscopic scale.

36 MATERIALS SCIENCE↗

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the ultrafast gain and refractive index dynamics of a VECSEL

Typically, strong gain saturation and gain dynamics play a crucial role in semiconductor laser mode-locking. While there have been several investigations of the ultrafast gain dynamics in vertical-external-cavity surface-emitting lasers (VECSELs), little is known about the associated refractive index changes. Yet, such refractive index changes do not only have a profound impact on the pulse formation process leading to self-phase modulation, which needs to be compensated by dispersion, but they are also of particular relevance for assessing the feasibility of Kerr-lens mode-locking of VECSELs. Here, we measure both refractive index as well as gain dynamics of a VECSEL chip using the ultrafast beam deflection method. We find that, in contrast to the gain dynamics, the refractive index dynamics is dominated by an instantaneous (100 fs) and a very slow component (100 ps). The time-resolved measurement of nonlinear refraction allows us to predict a pulse-length dependent, effective nonlinear refractive index n 2,eff , which is shown to be negative and on the order of 10 -16 m 2 =W for short pulse lengths (100 fs). It becomes positive for large excitation fluences and large pulse lengths (few ps). These results agree with some previous reports of self-mode-locked VECSELs for which the cavity design and pulse properties determine sign and strength of the nonlinear refractive index when assuming Kerr-lens mode-locking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

GPR Robotic Assisted Non-Destructive Evaluation of Concrete Structures - 20196

Reinforced concrete structures are always under exposure of internal or external deteriorations due to many factors such as environmental, nuclear radiation or even construction deficiencies. The use of nondestructive test is one of the reliable methods to inspect structural members. In this case, GPR has a good capability to detect inside deteriorations of concrete structures. However, in many cases it is hard to inspect structural members by hand due to safety issues or inaccessibility. Thus, an alternative way to reduce such risks is to employ robot to carry nondestructive equipment. In this research, twelve reinforced concrete RC beams (8 x 16 x 96, width, height and length) are cast in the lab. Three RC beams have no defect and nine others various defects such as corrosion, de-bonded bars, void, delamination and honeycombing. The one-point load is applied at the center of the RC beam. The loading level is carried out at three levels: 50%, 75% and 100% of maximum load and total load-displacement diagram are performed. The load is held at each level and the robotic GPR is used to scan the side of RC beams. Then, RADAN software is employed to find out any defects at different loading conditions and visualize the crack propagation. The RADAN results show that the pattern of crack propagation for corrosion and debonding are same. Also, the load-displacement results present that inside defect cause reduction of load-capacity of RC beam. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tidal Energy Resource Characterization, Velocity and Turbulence Measurements, Processed Data, Cook Inlet, AK, 2021

This submission contains processed datasets from a long-term deployment of 3 moorings and a transect survey of the proposed tidal energy site off the East Forelands in Cook Inlet, AK. The long-term mooring datasets were created from 8 instruments mounted on a Terrasond High Energy Oceanographic Mooring (THEOM) bottom lander and two Mid-Water Mooring (MWM) Stablemoor buoys from 1 July 2021 to 31 August 2021 (60 days). The west-most mooring (MWM1) was deployed at 60.720225 N, 151.436196 W in ~50 m of water. The middle mooring (THEOM) was deployed at 60.720703 N, 151.429500 W in ~52 m of water. The east-most buoy (MWM2) was deployed at 60.720081 N, 151.420896 W in ~50 m of water. Each Stablemoor carried three instruments: 1. A Nortek Vector acoustic Doppler velocimeter (ADV) mounted at the Stablemoor's nose. Data were recorded at 8 Hz on a 5 minute duty cycle every 20 minutes. Data was motion-corrected using the internal IMU and external ADCP bottom-track data and then bin-averaged into 4 minute bins and converted to the Principal (streamwise, cross-stream, vertical) coordinate system. (Note: 30 seconds were trimmed from the beginning and end of each 5 minute duty cycle to account for the filter end-effects from turning on and turning off the IMU.) 2. A down-looking Nortek Signature 1000 kHz acoustic Doppler current profiler (ADCP) mounted in the first Stablemoor instrument well. Data were recorded in 2 Hz with 5-beam burst and bottom-track enabled. Processed data has been averaged into 10 minute bins and converted into the Principal coordinate system. 3. An up-looking Nortek Signature 1000 kHz acoustic Doppler current profiler (ADCP) mounted in the second Stablemoor instrument well. Data were recorded at 4 Hz with 5 beam burst enabled. Processed data has been averaged into 10 minute bins and converted into the Principal coordinate system. Note: the down-facing ADCP on MWM1 failed on July 10th, 2021, only recording 9 days of data. Because ADV motion-correction required bottom track, the ADV from MWM1 also only has 9 days processed. Additionally, only 25 days of data were processed from the MWM2 ADV because it appeared to have been impacted by debris on 7/25. Two instruments were mounted on the THEOM (see MHKDR link further below for THEOM raw data): 4. A Nortek Vector acoustic Doppler velocimeter (ADV). Data were recorded at 8 Hz on a 5 minute duty cycle every 20 minutes. Data was bin-averaged into 5 minute bins, and converted to the Principal coordinate system. 5. A Nortek Signature 500 kHz acoustic Doppler current profiler (ADCP). Data were recorded in 4 Hz in the beam coordinate system from all 5 beams. Processed data has been averaged into 10 minutes bins and converted to the Principal coordinate system.

16 TIDAL AND WAVE POWER↗