Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗

Determination of Thermoelectric Module Efficiency A Survey

The development of thermoelectrics (TE) for energy conversion is in the transition phase from laboratory research to device development. There is an increasing demand to accurately determine the module efficiency, especially for the power generation mode. For many thermoelectrics, the figure of merit, ZT, of the material sometimes cannot be fully realized at the device level. Reliable efficiency testing of thermoelectric modules is important to assess the device ZT and provide the end-users with realistic values on how much power can be generated under specific conditions. We conducted a general survey of efficiency testing devices and their performance. The results indicated the lack of industry standards and test procedures. This study included a commercial test system and several laboratory systems. Most systems are based on the heat flow meter method and some are based on the Harman method. They are usually reproducible in evaluating thermoelectric modules. However, cross-checking among different systems often showed large errors that are likely caused by unaccounted heat loss and thermal resistance. Efficiency testing is an important area for the thermoelectric community to focus on. A follow-up international standardization effort is planned.

efficiency↗

A collaborative detection approach for internal steam leakage of tyre vulcanization workshop with artificial immune algorithm

In manufacturing industry, internal leakage of steam trap usually results in great steam waste. In particular, internal steam leakage in tyre vulcanization workshop has significant influences on its production safety and energy efficiency. In practice, internal steam leakage problem often is ignored and it tends to be difficult to detect this leakage due to lack of comprehensive flow meter or method. This paper presents a collaborative detection method for this problem in tyre vulcanization workshop with artificial immune algorithm. In the method, internal leakage of steam trap is defined as nonself antigens, and steam pressure differentials between steam pipe and steam rooms (or bladders) are extracted as epitopes of antigens. Furthermore, periodic energy efficiency and steam pressure of vulcanizer as the danger signals are simultaneously detected. Energy efficiency is represented by damaged cells which will be identified firstly for locating the leaking steam straps through antibodies. Furthermore, the self-adaptive danger thresholds for energy efficiency are evaluated through a steam consumption model and the Levenberg–Marquardt back propagation algorithm. An immune-based clustering algorithm aiNet is then adopted to generate antibodies (detectors) for detection on the steam pressure of vulcanizer. Finally, a case study is implemented to validate this method, which shows that collaborative detection method allows locating the specific leaking steam trap and is a feasible tool to reduce steam waste and ensure the safety of steam supply.

42 ENGINEERING↗

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI↗

Hydrogen losses in fueling station operation

This paper describes an engineering approach for hydrogen accounting from production to dispensing at Cal State Los Angeles Hydrogen Research and Fueling Facility, equipped with an electrolyzer for on-site production. Particularly, the accounting process has been carried out by taking an in-depth look at current practices and databases, and its analysis has been based on data from quarterly reports of hydrogen production and dispensing related parameters and from its data acquisition system. It is described how the station addressed this analysis investigating several station areas. Following there is an assessment of the possible critical points, flanked by considerations, calculations, mathematical modeling and analysis of the database. The analysis led to a marked improvement on the station operation know-how. For most of the analyzed months the current average percentage of losses was found to be between 2 and 10%, whereas before it was between 30 and 35%. This current range of percentage (2–10)% includes all experiments done, defueling the buffer tanks, rebooting the dispenser, venting the lines, the uncertainty of the mass flow meter inside the dispenser (±5%) and the inherent uncertainty of Faraday’s law for hydrogen production estimate. Among all areas analyzed, maintenance activities revealed themselves as the most critical ones, leading to data mismatching in hydrogen accounting. The paper aims also to provide a guideline with recommended practices based on our experience, deduced for station operators and builders, including several steps for leakage monitoring, prevention, and troubleshooting.

08 HYDROGEN↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Steady-state low thermal resistance characterization apparatus: The bulk thermal tester

The reliability of microelectronic devices is largely dependent on electronic packaging, which includes heat removal. The appropriate packaging design therefore necessitates precise knowledge of the relevant material properties, including thermal resistance and thermal conductivity. Thin materials and high conductivity layers make their thermal characterization challenging. A steady state measurement technique is presented and evaluated with the purpose to characterize samples with a thermal resistance below 100 mm{sup 2} K/W. It is based on the heat flow meter bar approach made up by two copper blocks and relies exclusively on temperature measurements from thermocouples. The importance of thermocouple calibration is emphasized in order to obtain accurate temperature readings. An in depth error analysis, based on Gaussian error propagation, is carried out. An error sensitivity analysis highlights the importance of the precise knowledge of the thermal interface materials required for the measurements. Reference measurements on Mo samples reveal a measurement uncertainty in the range of 5% and most accurate measurements are obtained at high heat fluxes. Measurement techniques for homogeneous bulk samples, layered materials, and protruding cavity samples are discussed. Ultimately, a comprehensive overview of a steady state thermal characterization technique is provided, evaluating the accuracy of sample measurements with thermal resistances well below state of the art setups. Accurate characterization of materials used in heat removal applications, such as electronic packaging, will enable more efficient designs and ultimately contribute to energy savings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating Powder Spreading Dynamics in Additive Manufacturing Processes by In-situ High-speed X-ray Imaging

The quality of the powder bed is known to be one of the main factors that influence the quality of the part being manufactured by powderbed- based additive manufacturing processes. For example, in the laser powder bed fusion process, it has been demonstrated that improving the powder bed density and homogeneity improves the final quality of the part. Understanding powder spreading dynamics in the powder-bed-based additive manufacturing processes is critical for designing spreading structures and spreading parameters, identifying defect formation mechanisms in the powder bed, and guiding the design of optimized feedstock powders. Extensive efforts have been devoted to understand the fundamental mechanism of the powder flow and spreading process. Various powder flow testers were used to study the flow behavior of powders used in additive manufacturing. However, the powder flow conditions in flow meters are different from those in real additive manufacturing conditions. Models have also been developed to simulate and study the spreading process. The discrete element method (DEM) is currently the main tool for computationally simulating the spreading process. However, these models are based on many physical assumptions. Visible light cameras have been used recently to conduct in-situ study of powder spreading in additive manufacturing. Due to the limited resolution and penetration depth of visible light, it is extremely difficulty to study the particle-scale powder spreading dynamics. Here, to overcome the challenges of studying powder spreading dynamics under real additive manufacturing conditions, we developed an experimental approach to study the particle-scale powder spreading process with high spatial and temporal resolution using the high-speed high-energy X-ray imaging facility at beamline 32-ID-B of the APS. Figure 1 shows an overview of the research setup. It is composed of a vacuum chamber (building environment), an automatic powder spreading system, a laser system, an X-ray source (X-ray outlet), and an X-ray detection/imaging system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modifying Network Guided Vehicle for Repeatable EcoCAR ACC Energy Testing

The newest iteration of the Department of Energy (DOE) Advanced Vehicle Technology Competitions is the EcoCAR Mobility Challenge. In this paper, ANL and HORIBA MIRA collaborate to propose and pilot a test method that enables controlled, repeatable track-based energy consumption testing of semi-autonomous features. The testing was performed at MIRA’s proving ground facility in Nuneaton, UK, using their Network Guided Vehicle (NGV) connectivity and automation test platform. The NGV served as a repeatable lead vehicle following prescribed drive traces around two different track circuits while the host vehicle under test, a Honda Civic with full speed range Adaptive Cruise Control, followed behind. Over the course of a two day test, multiple iterations of certification and custom EPA drive traces were performed on track, demonstrating the viability of a two vehicle energy test. Results were analyzed to assess NGV lead vehicle performance in following the prescribed cycle using SAE J2951 standard calculations in an effort to quantify how repeatably and accurately the lead vehicle followed the trace. Host vehicle energy consumption was assessed using both vehicle CAN bus monitoring and an on-board fuel flow meter.

ACC↗

Development of an electronic seepage chamber for extended use in a river.

Seepage chambers have been used to characterize the flux of water across the water-sediment interface in a variety of settings. In this work, an electronic seepage chamber was developed specifically for long-term use is a large river where hydraulic gradient reversals occur frequently with river stage variations. A bi-directional electronic flow meter coupled with a custom built seepage chamber was used to measure temporal changes in the magnitude and direction of water flux across the water-sediment interface. The seepage chamber is capable of measuring average specific discharge as low as 1 x 10-6 cm/s over a 15-minute period. The specific discharge measured from the seepage chamber compared favorably with measurements of vertical hydraulic gradient and vertical hydraulic conductivity measured adjacent to the seepage chamber, demonstrating the effectiveness of the electronic seepage chamber to quantify water flux in two directions over a multi-month period.

47 OTHER INSTRUMENTATION↗

Design, Development, and Operation of an Integrated Fluidized Carbon Capture Unit Using Polyethylenimine Sorbents

In this paper, we present the design, development, and operation of a reactor system for CO 2 capture. Modifications were implemented to address differences in sorbent from 180 μm Geldart group B to 115 μm Geldart group A material; operational issues were discovered during experimental trials. The major obstacle in system operation was the ability to maintain a constant circulation of a solid sorbent stemming from this change in sorbent material. The system consisted of four fluid beds, through which a polyamine impregnated sorbent was circulated and adsorption, preheat, regeneration, and cooling processes occurred. Pressure transducers, thermocouples, gas flow meters, and gas composition instrumentation were used to characterize thermal, hydrodynamic, and gas adsorption performance in this integrated unit. A series of shakedown tests were performed and the configuration altered to meet the needs of the sorbent performance and achieve desired target capture efficiencies. Methods were identified, tested, and applied to continuously monitor critical operating parameters including solids circulation rate, adsorbed and desorbed CO 2 , solids inventories, and pressures. The working capacity and CO 2 capture efficiency were used to assess sorbent performance while CO 2 closure was used to define data quality and approach to steady-state. Testing demonstrated >90% capture efficiencies and identified the regenerator to be the process step limiting throughput. Sorbent performance was found to be related to the reactant stoichiometry. Finally, a stochastic model with an exponential dependence on the relative CO 2 /amine concentration was used to describe 90% of the variance in the data.

01 COAL, LIGNITE, AND PEAT↗

Final Project Report: Self-Correcting Controls for VAV System Faults Filter/Fan/Coil and VAV Box Sections

This report addresses original research by the Pacific Northwest National Laboratory for the California Institute for Energy and Environment on self-correcting controls for variable-air-volume (VAV) heating, ventilating and air-conditioning systems and focuses specifically on air handling and VAV box components of the air side of the system. A complete set of faults for these components was compiled and a fault mode analysis performed to understand the detectable symptoms of the faults and the chain of causation. A set of 26 algorithms was developed to facilitate the automatic correction of these faults in typical commercial VAV systems. These algorithms include training tests that are used during commissioning to develop models of normal system operation, passive diagnostics used to detect the symptoms of faults, proactive diagnostics used to diagnose the cause of a fault, and finally fault correction algorithms. Ten of the twenty six algorithms were implemented in a prototype software package that interfaces with a test bed facility at PNNL's Richland, WA, laboratory. Measurement bias faults were instigated in the supply-air temperature sensor and the supply-air flow meter to test the algorithms developed. The algorithms as implemented in the laboratory software correctly detected, diagnosed and corrected these faults. Finally, an economic and impact assessment was performed for the State of California for deployment of self-correcting controls. Assuming 15% HVAC energy savings and a modeled deployment profile, 3.1-5.8 TBu of energy savings are possible by year 15.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells

High Temperature insulated wire and optical fiber cable is a key enabling technology for the Geothermal Technologies Program (GTP). Without insulated electrical wires and optical fiber, downhole temperature and pressure sensors, flow meters and gauges cannot communicate with the surface. Unfortunately, there are currently no insulated electrical wire or fiber cable constructions capable of surviving for extended periods of deployment in a geothermal well (240-325°C) or supercritical (374°C) reservoir. This has severely hindered engineered reservoir creation, management and utilization, as hot zones and cool water intrusions cannot be understood over time. The lack of a insulated electrical wire and fiber cable solution is a fundamental limitation to the viability of this energy source. The High Temperature Downhole Tools target specification is development of tools and sensors for logging and monitoring wellbore conditions at depths of up to 10,000 meters and temperatures up to 374oC. It well recognized in the industry that no current electronic or fiber cable can be successfully deployed in a well and function successfully for more a few days at temperatures over 240oC. The goal of this project was to raise this performance level significantly. Prysmian Group’s objective in this project was to develop a complete, multi-purpose cable solution for long-term deployment in geothermal wells/reservoirs that can be used with the widest variety of sensors. In particular, the overall project objective was to produce a manufacturable cable design that can perform without serious degradation: • At temperatures up to 374°C; • At pressures up to 220 bar; • In a hydrogen-rich environment; and • For the life of the well (> 5 years). This cable incorporates: • Specialty optical fibers, with specific glass chemistry and high temperature and pressure protective coatings for data communication and distributed temperature and pressure sensing, and • High-temperature insulated wire conductors Prysmian Group has developed a geothermal fiber optic cable (GFOC) solution which incorporates novel glass chemistry for optical fibers to operate at the required bandwidths in high temperature/high pressure hydrogen rich environments with fiber protection, high temperature insulated conductors and protective cladding for cable components. The cable solution has been tested in a geothermal installation for 10 months. The electrical insulation and optical fibers have been validated through laboratory testing to ensure successful operation for greater than 5 years at 300°C, with the possibility of higher temperatures depending on the particular well environment. With the 300°C optical fiber and electrical insulation developments completed and validated in laboratory tests the greatest challenge to a complete 300°C cable solution was protecting the optical fibers in the cable. Optical fibers are typically incased in a protective tube where the tube is filled with a gel. The gel serves as mechanical protection, prevent moisture ingress, and can include hydrogen scavenging materials. A suitable gel for use at 300°C could not be identified and an industrialized alternative was not fully attained. Despite the problems encountered and the lower long-term operating temperature of the cable solution, the project showed success in developing a complete cable solution for a large portion of the geothermal wells in operation today. Further work to obtain the higher long-term temperature goal of the project can be achieved based on the knowledge gained in the current project. This project is significant for many reasons including the new materials science, manufacturing technology, energy independence, and jobs created and will create.

15 GEOTHERMAL ENERGY↗

Reconciling Basin-Scale Top-Down and Bottom-Up Methane Emission Measurements for Onshore Oil and Gas Development: Cooperative Research and Development Final Report, CRADA Number CRD-14-572

The overall objective of the Research Partnership to Secure Energy for America (RPSEA)-funded research project is to develop independent estimates of methane emissions using top-down and bottom-up measurement approaches and then to compare the estimates, including consideration of uncertainty. Such approaches will be applied at two scales: basin and facility. At facility scale, multiple methods will be used to measure methane emissions of the whole facility (controlled dual tracer and single tracer releases, aircraft-based mass balance and Gaussian back-trajectory), which are considered top-down approaches. The bottom-up approach will sum emissions from identified point sources measured using appropriate source-level measurement techniques (e.g., high-flow meters). At basin scale, the top-down estimate will come from boundary layer airborne measurements upwind and downwind of the basin, using a regional mass balance model plus approaches to separate atmospheric methane emissions attributed to the oil and gas sector. The bottom-up estimate will result from statistical modeling (also known as scaling up) of measurements made at selected facilities, with gaps filled through measurements and other estimates based on other studies. The relative comparison of the bottom-up and top-down estimates made at both scales will help improve understanding of the accuracy of the tested measurement and modeling approaches. The subject of this CRADA is NREL's contribution to the overall project. This project resulted from winning a competitive solicitation no. RPSEA RFP2012UN001, proposal no. 12122-95, which is the basis for the overall project. This Joint Work Statement (JWS) details the contributions of NREL and Colorado School of Mines (CSM) in performance of the CRADA effort.

54 ENVIRONMENTAL SCIENCES↗

Conceptual Design of an Improved Sodium Plugging Loop

Based upon lessons learned in operating the initial sodium portion of the Sodium Plugging Phenomena Loop that itself became plugged and could not be unplugged, a set of improved design features have been identified for a new sodium loop that is less prone to inadvertent plugging. The new design features include a new sodium vessel that combines the functionalities of an expansion tank and a cold trap, increasing the loop tubing diameter/size, improving the thermal designs of the pump and flow meter, improved heater zoning, and an improved temperature distribution strategy along the loop. A new plugging loop conceptual design implementing these features has been developed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tradeoffs in Prameter Values for Optional Performance

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively, In general, continuous operation of most commercial ultrasonic transducers above 50°C is challenging because of transducer material incompatibility with high temperature. High-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150⁰C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Solar Turbines Incorporated

The National Energy Technology Laboratory is developing the Raman Gas Analyzer (RGA) to be a fast, non-destructive instrument for on-line measurement of gas composition. The RGA prototype has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, but Raman interaction is weak with gas phase substances. The RGA uses a reflectively lined capillary as the optical cell in a patented configuration, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (including CO, CO2, N2, O2, H2O). The RGA provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process, such as improving fuel flexibility and efficiency for power generation systems. NETL has constructed a field prototype of the RGA to test the instrument performance in various applications in fossil energy. Through this CRADA, the RGA prototype operation was tested using hydrocarbon mixtures and hydrogen on a combustor test rig for potential use in gas turbine engine testing. The testing was performed at the Solar Turbines Incorporated Harbor Drive facility in downtown San Diego, CA on December 3-7, 2018. The RGA was installed outside a combustor test bay, with a ¼" sample line connected from a point shortly upstream of the test combustor. The combustion test building online gas chromatograph reported analysis of a sample every 6 minutes. During testing, seven test conditions of pure gas or gas mixtures were supplied to a pressurized combustion test rig. A sample of the fuel gas was continuously analyzed using the RGA with a 1 second measurement and reporting time. For each test condition, once the steady condition was reached, the composition of the gas from the RGA measurements is reported, along with the expected composition from the flow meters, and the composition reported by the online gas chromatograph (GC). During this testing, the real-time measurement capability of the RGA was readily apparent. The composition changes occurring in real-time could be followed and observed to correspond to combustion behavior changes on the video monitor at the operator station. The largest concentration species were tracked well through the tests; however, from comparison of the RGA one-second data with the GC steady-state points, it appears the RGA had some difficulty with quantifying hydrocarbon mixtures, especially when some of the hydrocarbons were at low concentration. The difficulty was particularly noted for ethane and butane in these tests. The NETL team intends to address this in 2019. Moderate concentrations of nitrogen, carbon dioxide, and hydrogen (>10%) were readily observed in the spectral data and quantified closely to the GC measurements. While calibration data for propylene was collected in preparation for this testing, it was not observed during the testing, even when the test conditions had high concentrations of propane.

Source record↗