Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedence analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring the long-term performance of organic redox flow battery by a distribution of relaxation time analysis

Organic redox flow batteries hold great promise as an energy storage technology, but their intricate chemistry makes them vulnerable to various degradation mechanisms. Monitoring this degradation is essential for identifying the limiting processes within the cells. Electrochemical impedance spectroscopy (EIS) offers a straightforward, in-situ method for measuring the total resistance of an operating cell. However, to pinpoint the limiting processes during long-term cycling, EIS data must be complemented by other techniques. Distribution of relaxation time (DRT) analysis is particularly effective for differentiating resistance components. Here, in this study, we perform a comprehensive analysis of resistance evolution and the separation of anode and cathode contributions during long-term cycling of a full cell employing 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) as the anolyte. Separate analyses of the DHPS anolyte and ferri-/ferrocyanide catholyte were conducted using a symmetric cell setup. The relaxation times derived from symmetric cells facilitate the identification of peaks in the DRT profiles from the full cell. Importantly, the DRT profiles indicate a correlation between the evolution of charge transfer resistance and the chemical degradation of DHPS. The methodologies and results outlined in this study offer significant insights for developing diagnostic tools applicable to other types of redox flow batteries.

Distribution of relaxation time↗

SpectraCodec: A Hilbert curve-based method for encoding metadata in mass spectra for machine learning applications (SpectraCodec) v1

Machine learning approaches to mass spectrometry (MS) data analysis require structured metadata for optimal performance. However, current MS file formats necessitate external metadata sources, creating integration challenges that impede analytical workflows. Here, we present a novel approach for encoding metadata directly within mzML files using one-hot encoding of ASCII characters mapped via Hilbert space-filling curves. This strategy embeds metadata in the first spectrum's m/z-intensity space, ensuring persistence with the primary data, eliminating the need for external metadata files, and maintaining compatibility with existing MS software. We demonstrate that the Hilbert curve mapping efficiently utilizes the two-dimensional spectral space while maintaining robust data recovery. This method offers a practical solution for machine learning applications in mass spectrometry by ensuring metadata and spectral data remain unified through all stages of analysis.

Bowen, Benjamin [Lawrence Berkeley National Labora↗

The MUSIC Critical Benchmark and Nuclear Data

The Measurement of Uranium Subcritical and Critical (MUSIC) experiment was a series of measurements of critical and subcritical configurations of bare highly enriched uranium. The goal was to compare measurement methods, analysis techniques, and simulation methods across regimes of criticality and to provide high-quality validation of 235 U nuclear data. A benchmark evaluation of the two critical configurations of the MUSIC experiments will soon be published in the release of the International Criticality Safety Benchmark Evaluation Project Handbook. The recent execution of the experiment aids in proper quantification of model simplifications and all uncertainties associated with the experiment. Historical benchmark evaluations are heavily relied on for uranium nuclear data validation despite the fact that the same level of documentation and comparable uncertainty analysis may not be present. The MUSIC evaluation is less likely to include “unknown unknowns” that could impede accurately modeling the system. Presented are both highly detailed and very simplified models, which represent the experimental configurations accurately, aiding the users of the benchmark for nuclear data or transport code validation. The sensitivities of k eff to nuclear data and nuclear data–related uncertainties are very similar between this experiment and previous bare uranium sphere experiments. In addition, the nuclear data uncertainties to any nuclides other than 235 U are small. For all these reasons, the recently evaluated MUSIC benchmark critical configurations could prove very useful for 235 U nuclear data validation. Currently, major libraries have good agreement with the experimental results, within 200 pcm for all nuclear data libraries, and within one standard deviation of the experimental result for most. Suggested nuclear data adjustments based on MUSIC and Lady Godiva are also presented, with posterior improvements to both the agreement in k eff and the uncertainty associated with the nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impacts of Solvent Washing on the Electrochemical Remediation of Commercial End-of-Life Cathodes

Changes to surface structure and chemistry occurring throughout the functional lifetime of lithium-ion batteries (LIBs) may impact the effectiveness of end-of-life rejuvenation methods. Solvent washing prior to electrochemical relithiation is shown to both increase relithiation efficacy and beneficially alter the interfacial chemistry of heavily degraded industrial cathode material. Four common solvents (acetone, diethyl carbonate, isopropyl alcohol, propylene carbonate) are employed to investigate the role of varying physicochemical solvent properties on the mechanism of capacity recovery. Electrochemical (dQ/dV, EIS), structural (XRD), and chemical (SPME-GC-MS) analysis techniques are employed to comprehensively analyze solvent-cathode interactions. Highly nucleophilic solvents (acetone, DEC) are found to reduce cathode charge-transfer impedance and enable stable impedance growth throughout subsequent cycling. The use of nucleophilic solvents under mechanically aggressive washing conditions may also enable the reintroduction of bulk lattice oxygen, thereby restoring anionic redox capacity. Further, the four solvents are found to selectively remove a subset of surface species from the aged cathode material, including residual electrolyte, additives, and electrolyte-additive reaction products, which are qualitatively analyzed. Surface species removal by each solvent is correlated with the electrochemical performance of the correspondingly washed cathode, highlighting the importance of an optimized washing protocol to effective remediation in the context of direct LIB recycling. For the material under study, the use of a simple acetone washing protocol prior to electrochemical relithiation enables up to 174% capacity recovery relative to unwashed/relithiated black mass.

ADVANCED PROPULSION SYSTEMS↗

How reliable is distribution of relaxation times (DRT) analysis? A dual regression-classification perspective on DRT estimation, interpretation, and accuracy

The distribution of relaxation times (DRT) has gained increasing attention and adoption in recent years as a versatile method for analyzing electrochemical impedance spectroscopy (EIS) data obtained from complex devices like fuel cells, electrolyzers, and batteries. The DRT deconvolutes the impedance without a priori specification of a generative model, which is especially useful for interpretation and model selection when the governing principles of the system under study are not fully understood. However, DRT estimation is an ill-posed inversion problem that must be addressed with a subjective choice of regularization and tuning, which leaves substantial risk of misleading interpretations of EIS data. In this work, we suggest a new classification view of the DRT inversion to clarify DRT estimation and interpretation. We introduce a dual regression-classification framework that unifies the classification and regression views of the DRT inversion with wide-reaching implications for DRT analysis. The dual framework is employed to demonstrate a new kind of DRT inversion algorithm and develop novel evaluation metrics that capture previously ignored aspects of DRT accuracy. These approaches are applied to both synthetic data and experimental spectra collected from a protonic ceramic fuel cell and a lithium-ion battery to illustrate their broad utility. The dual inversion algorithm shows promising performance for accurate DRT estimation and autonomous model identification, while the dual evaluation approach produces metrics that meaningfully assess the strengths and risks of DRT algorithms. Here this work provides valuable insight for both practical application of the DRT to experimental data and further development of EIS analysis methods.

36 MATERIALS SCIENCE↗

Impedance Modeling for Mixed Conductors with Simultaneous Insertion & Electrocatalytic Reactions: A Case Study of Transition-Metal Hydroxides in Aqueous Electrolyte

Electrochemical impedance spectroscopy (EIS) is commonly used to investigate the kinetics of mixed ionic–electronic conductor (MIEC) electrodes. Across various applications, MIECs exhibit ionic (e.g., insertion) and/or electronic (e.g., electrocatalytic) charge transfer reactions at the electrode/electrolyte interface. Bulk storage and transport of charge carriers also couple with these interfacial reactions. Here, we build a generalized, physics-based impedance model for MIECs with an ion-blocking current collector and explore how bulk and interfacial resistance, chemical capacitance, and DC polarization affect the impedance response. Using transition metal hydroxides as a case study, we provide guidance on extracting reaction kinetics or bulk resistance from the Nyquist plots in interface- or bulk-controlled conditions, respectively. Generalizing our EIS analysis enables a robust analysis of MIEC kinetics for a diverse set of systems.

36 MATERIALS SCIENCE↗

Tuning discharge voltage by Schottky electron barrier in P2-Na 2/3 Mg 0.205 Ni 0.1 Fe 0.05 Mn 0.645 O 2

Recently, Mg doped Na metal oxide layered cathode compounds have attracted strong interest for Na-ion battery applications. We report a new type of asymmetric phase evolution between charge and discharge is found to show much-enhanced discharge voltage in P2-Na 2/3 Mg 0.205 Ni 0.1 Fe 0.05 Mn 0.645 O 2 over the parent cathode compound. P2 solid solution is found to show an abnormal coexistence with O2-P2 two-phase reaction during discharge with simultaneous reduction of O, Ni, and Fe redoxes, distinct from the conventional P2-O2 two-phase reaction in the charge. Our analysis suggests that the P2 and O2 two-phase boundary forms a novel unidirectional Schottky barrier to impede electron and Na diffusions in discharge only, thus making the kinetically preferred P2 solid solution phase abnormally coexist with the two-phase region for high discharge voltage and low polarization. Our work demonstrates tuning dynamic evolution of electronic Schottky barrier as a new dimension for advanced kinetic design of high-performance battery cathode materials.

25 ENERGY STORAGE↗

Characterization of the acoustic cavitation in ionic liquids in a horn-type ultrasound reactor

Most ultrasound-based processes root in empirical approaches. Because nearly all advances have been conducted in aqueous systems, there exists a paucity of information on sonoprocessing in other solvents, particularly ionic liquids (ILs). In this work, we modelled an ultrasonic horn-type sonoreactor and investigated the effects of ultrasound power, sonotrode immersion depth, and solvent’s thermodynamic properties on acoustic cavitation in nine imidazolium-based and three pyrrolidinium-based ILs. The model accounts for bubbles, acoustic impedance mismatch at interfaces, and treats the ILs as incompressible, Newtonian, and saturated with argon. Following a statistical analysis of the simulation results, we determined that viscosity and ultrasound input power are the most significant variables affecting the intensity of the acoustic pressure field (P), the volume of cavitation zones (V), and the magnitude of the maximum acoustic streaming surface velocity (u). V and u increase with the increase of ultrasound input power and the decrease in viscosity, whereas the magnitude of negative P decreases as ultrasound power and viscosity increase. Probe immersion depth positively correlates with V, but its impact on P and u is insignificant. 1-alkyl-3-methylimidazolium-based ILs yielded the largest V and the fastest acoustic jets – 0.77cm 3 and 24.4ms -1 for 1-ethyl-3-methylimidazolium chloride at 60W. 1-methyl-3-(3-sulfopropyl)-imidazolium-based ILs generated the smallest V and lowest u – 0.17cm 3 and 1.7ms -1 for 1-methyl-3-(3-sulfopropyl)-imidazolium p-toluene sulfonate at 20W. Sonochemiluminescence experiments validated the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Demand Response Analysis for Different Residential Personas in a Comfort-Driven Behavioral Context

Low demand response (DR) participation and high program drop-out rates continue to impede DR goals that could save up to $13 billion in annual grid expansion and electricity demand costs. Yet, the literature lacks a thorough understanding of how different residential customer segments enrolled in DR programs respond to utility signals in view of occupant comfort considerations. The objective of this study is to gain a clear understanding of the effects of four different customer personas on residential DR. Given current data limitations, this work developed an array of hypothetical personas with varied priorities, activity levels, and comfort thresholds based on demographic variables that have been found in previous studies to influence energy consumption. A BEopt DR model for a reference residential single-family building located in Colorado was built to isolate the effect of differences in buildings or climate. The results provide useful evidence on how persona-comfort differences lead to significant deviations in DR goals (especially peak demand reduction), ranging from 0.1% to 20%. This work presents a novel framework representing comfort preferences in DR models. The data generated, albeit synthetic, and the results could inform DR program design considerations of how different people respond to different comfort priorities.

BEopt↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Plasticizer-Free Gradient-Crosslinked Polyurethane Electrolyte for Room-Temperature Solid-State Lithium Batteries

Polymer-based solid-state electrolytes are promising for next-generation lithium metal batteries, yet their limited ionic conductivity and mechanical stability at ambient conditions remain key challenges. Herein, we report a novel gradient crosslinked polymer electrolyte (PU/PUA/PU) synthesized via a sequential in situ UV-curing process that integrates a mechanically robust polyurethane acrylate (PUA) core with soft linear polyurethane (PU) interfaces. This all-solid membrane operates without any liquid plasticizer and the interfacial PU layers ensure low interfacial resistance and intimate electrode contact, while the PUA core provides enhanced dimensional stability and dendrite suppression. As a result, the gradient electrolyte delivers an impressive ∼2.6 × 10 −4 S cm −1 ionic conductivity at 25 °C (two orders of magnitude higher than conventional PEO) and remains electrochemically stable >5 V (vs Li + /Li). Structural analysis confirms the formation of a well-defined crosslinked network with suppressed crystallinity and expanded interchain spacing. Electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) further validate these properties. When applied in a Li||NMC811 cell, the PU/PUA/PU electrolyte delivers stable cycling with high capacity at both 60 °C and 25 °C, demonstrating its potential for room-temperature solid-state battery applications without reliance on plasticizers or heating. In conclusion, this gradient design offers a practical path toward ambient-condition operation of solid-state lithium batteries, providing a paradigm for overcoming the traditional trade-off between ionic conductivity and mechanical robustness.

25 ENERGY STORAGE↗

Multipole-based Cable Braid Magnetic Penetration Model for Conducting Wires

In this report, we investigate the effects of conductor losses in a multipole-based cable braid magnetic penetration model. Our multipole model uses a mesh of the actual cable geometry, which enables us to model more complicated structures. After summarizing the first principles model formulation, we consider a one-dimensional array of wires, for which an analytical solution is known in the lossless case. We extend this solution to the lossy case by using a complex-valued radius. We also model this structure analytically using a conformal-mapping solution. We then compare both the self-impedance and the transfer impedance results from our first principles cable braid electromagnetic penetration model to those obtained using the analytical solutions. An analysis for various frequencies (and skin depths) usually encountered in cable modeling is reported. These results are found in good agreement up to a radius to half spacing ratio of about 0.7, demonstrating a robustness needed for many commercial and non-commercial cables.

36 MATERIALS SCIENCE↗

Field-Coupled Water Splitting with Metal-Free Donor–Acceptor Covalent Organic-Framework Junctions

Advancing metal-free electrocatalysts for hydrogen and oxygen evolution reactions (HER/OER) across acidic and alkaline media requires coordinated control of intermediate binding thermodynamics, interfacial charge delivery, and near-electrode transport dynamics. Here, we design amide-linked benzene–triazine covalent organic frameworks (BTA/TzTA-Hz COFs) and integrate them with carbon nanotubes (CNTs) to form COF–CNT junctions that establish a built-in interfacial electric field. Density functional theory (DFT) and electrostatic potential maps indicate complementary active motifs, with benzene-proximal fragments associated with HER and triazine-proximal motifs associated with OER. CNT integration shifts the contact-potential difference by ≈0.20 V, while operando electrochemical impedance spectroscopy suggests partially separable high-frequency junction-charging and lower-frequency Faradaic/transport responses. A 300 mT static magnetic field lowers the HER and OER overpotentials by tens of millivolts. Under anodic bias, the effective interfacial charging capacitance increases, and Mott–Schottky analysis shows an apparent ∼0.15 V flat-band shift with an essentially unchanged slope. Together, these observations are consistent with field-perturbed interfacial charging and altered bias partitioning. Field-dependent impedance and bubble imaging are consistent with magnetohydrodynamic convection that promotes bubble detachment and near-electrode mass transport for both half-reactions, and they reveal an OER-specific high-frequency perturbation under anodic bias. Under field, the heterostructure reaches an OER onset overpotential of ∼261 mV and requires an overpotential of 366 mV at 10 mA cm –2 in alkaline electrolyte. These results illustrate how reticular-framework chemistry, junction engineering, and both built-in and applied fields can program reactivity through interfacial electrostatics and near-electrode transport in organic-framework electrocatalysts.

Garcia-Enriquez, Lissette [Univ. of Texas at El Pa↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemical and Electrochemical Characterization of Hot–Pressed Li 6 PS 5 Cl Solid State Electrolyte: Operating Pressure–Invariant High Ionic Conductivity

Sulfide solid state electrolytes (SSE) are among the most promising materials in the effort to replace liquid electrolytes, largely due to their comparable ionic conductivities. Among the sulfide SSEs, Argyrodites (Li 6 PS 5 X, X=Cl, Br, I) further stand out due to their high theoretical ionic conductivity (~1×10 –2 S cm –1 ) and interfacial stability against reactive metal anodes such as lithium. Generally, solid state electrolyte pellets are pressed from powder feedstock at room temperature, however, pellets fabricated by cold pressing consistently result in low bulk density and high porosity, facilitating interfacial degradation reactions and allowing dendrites to propagate through the pores and grain boundaries. Here, we demonstrate the mechanical and electrochemical implications of hot-pressing standalone LPSCl SSE pellets with near-theoretical ionic conductivity, superior cycling performance, and enhanced mechanical stability. X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and x-ray diffraction spectroscopy (XRD) analysis reveal no chemical changes to the Argyrodite surface after hot pressing up to 250°C. Furthermore, we use electrochemical impedance spectroscopy (EIS) to understand mechanical stability of Argyrodite SSE pellets as a function of externally applied pressure, demonstrating for the first time pressed standalone Argyrodite pellets with near-theoretical conductivities at external pressures below 14 MPa.

25 ENERGY STORAGE↗