Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

On the application of the expected log-likelihood gain to decision making in molecular replacement

Molecular-replacement phasing of macromolecular crystal structures is often fast, but if a molecular-replacement solution is not immediately obtained the crystallographer must judge whether to pursue molecular replacement or to attempt experimental phasing as the quickest path to structure solution. The introduction of the expected log-likelihood gain has given the crystallographer a powerful new tool to aid in making this decision. The eLLG is the log-likelihood gain on intensity expected from a correctly placed model. It is calculated as a sum over the reflections of a function dependent on the fraction of the scattering for which the model accounts, the estimated model coordinate error and the measurement errors in the data. It is shown how the eLLG may be used to answer the question 'can I solve my structure by molecular replacement?'. However, this is only the most obvious of the applications of the eLLG. It is also discussed how the eLLG may be used to determine the search order and minimal data requirements for obtaining a molecular-replacement solution using a given model, and for decision making in fragment-based molecular replacement, single-atom molecular replacement and likelihood-guided model pruning.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Distributive Consensus Algorithms for AnomalyDetection on the Power-Grid

As an increasing number of devices in the power-grid rely on high-precision clocks to measure electrical properties and time stamp data, GPS receivers have become a vulnerability on the power-grid. GPS spoofing attacks, in which a fake signal is transmitted, can cause sensor measurement errors that can misinform protective equipment and grid operators for both the transmission and distribution grid. The technology being developed to secure precision clocks in the transmission grid are not appropriate for the distribution grid. Thus, there is a need to developed anomaly detection algorithms that are suitable for the hardware available on the distribution grid. Traditionally, a distributed detection framework is comprised of spatially distributed nodes which acquire observations about a quantity of interest and sends the data to the fusion center, where a global decision is made. Instead the distribution grid has low-power devices, such as smart inverters and microPMUs, that could be used to perform highly parallelized calculations. Having on node calculations is beneficial since it is more network and computation efficient, as the more calculations can be performed where the data is being captured instead of communicating across a slow network to a centralized fusion center. Instead, we could employ an alternate peer-to-peer type of information exchange on the distribution grid that can still reach a global decision. A decentralized approach to anomaly detection makes efficient use of the computational and network bandwidth that exists, and it also lacks the single point of failure of a centralized approach. Thus, a decentralized local information exchange and/or inference is preferred. Lastly, the unreliability of the distribution grid network connections and potential noise or error in the measurements must be considered. In order to produce an effective detection tool, a Byzantine-fault tolerant and asynchronous algorithm must be developed. Thus, the first phase of our project is to develop a distributed, decentralized, asynchronous, Byzantine-fault tolerant, collaborative autonomy-based anomaly detection algorithm to collectively analyze clusters of data for signs of a malicious attack.

97 MATHEMATICS AND COMPUTING↗

On the Accurate Calibration of the SeaWinds Radar Antenna: A Cylindrical Near-Field Measurement Approach

This paper demonstrates the utility of a cylindrical near-field measurement approach for the SeaWinds radar antenna calibration. Both generalized measurement error models and measured tests on a standard gain horn and NASA Scatterometer instrument antenna have been performed to achieve and verify the desired calibration accuracy. A comparison between far-field measured data and those obtained from cylindrical near-field measurements was found in excellent agreement.

spaceborne↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried instrumentation installed on the heatshield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments included pressure transducers, thermocouples, heat flux gauges, and a radiometer to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, were co-located on the backshell. The sensors were exposed to roughly the same aerodynamic heating, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that backshell location. The approach makes use of the Kalman-Schmidt filter/smoother methodology, where systematic measurement error parameters are modeled as multiplicative states that are estimated by the filter along with the aerothermal states. The results indicate peak convective and radiative heating values of 0.86 and 5.16 W/cm2, respectively, compared to the filter predictive model values of 0.67 and 4.83 W/cm2.

Christopher D Karlgaard↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried instrumentation installed on the heatshield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments included pressure transducers, thermocouples, heat flux gauges, and a radiometer to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, were co-located on the backshell. The sensors were exposed to roughly the same aerodynamic heating, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that backshell location. The approach makes use of the Kalman-Schmidt filter/smoother methodology, where systematic measurement error parameters are modeled as multiplicative states that are estimated by the filter along with the aerothermal states. The results indicate peak convective and radiative heating values of 0.86 and 5.16 W/cm$^2$, respectively, compared to the filter predictive model values of 0.67 and 4.83 W/cm$^2$.

Christopher D Karlgaard↗

A Study of the Effect of Errors in Measurement of Velocity and Flight-Path Angle on the Guidance of a Space Vehicle Approaching the Earth

An analysis was made of the guidance of a space vehicle approaching the earth at supercircular velocity through an entrance corridor containing a desired perigee altitude. Random errors were assumed in the measurement of velocity and flight-path angle and in obtaining the desired thrust impulse. The method described in NASA Technical Note D-191 of scheduling corrections at different values of the angle between perigee and the vehicle's position vector and a slight modification of this method were investigated as a means of correcting perigee altitude when the vehicle's predicted position was at programmed correction points not within a specified deadband about the desired perigee altitude. The study showed that modifying the angular method of NASA Technical Note D-191 by adding another correction near the initial point did not improve the efficiency and accuracy of the angular method. It was found that in some cases the use of a correction procedure which included a deadband could be more costly in total corrective velocity than a procedure which neglected the deadband. This was especially true if a large degree of confidence was required in the total corrective velocity. It was apparent from the results that a correction with a deadband limit in the guidance scheme was more sensitive to the initial conditions, the corrective procedure, the deadband, and the degree of confidence required than a correction without a deadband limit.

White, Jack A.↗

The MSS control point location error filter for LANDSAT-D

The filter produces the maximum likelihood estimates for average values of the spacecraft position and attitude errors during a single scene. The quality of the filter performance is characterized by the maximal cross and along track residual errors for which probability distributions can be calculated analytically for a given pattern of control points. The filter with an automatic selection of the best set of estimates provides geodetic correction at 90% of pixels with residual errors less than 40 m for four or more control points and the mean squared measurement errors of the order of 20-25 m. The same accuracy can be preserved for eight or more control points and measurement errors of 30-35 m.

Levine, I.↗

Advanced Payload Transfer Measurement System (APT-MS) Mechanical Features

During the last two feet or so of transfer, for a large or heavy payload to its restraining fixture, the consequences of unplanned contact (or impact) between payload and support structure can range from merely annoying to something approaching disaster. Current transfer methods employ technicians with meter sticks stationed at the various hold-down locations to estimate the distances to contact. This information is communicated orally to the crane operator. It is understandable that this work proceeds carefully and therefore slowly. The objectives of this study are (1) to explore mechanical sources of measurement error; and (2) to develop an improved prototype design that is compact, inexpensive, and addresses the measurement error issues. APT is a relatively inexpensive electro-mechanical device that reduces both time and manpower required to make shuttle payload transfers. APT measurement system would provide a GUI for the 'move-conductor' (crane operator) so he could see the displacements of all hold-down interfaces as they move together and thus have a more accurate, comprehensive and 'real-time' picture of the engagement activity. An error model attempts to include all estimatable sources of mechanical error and design features were introduced to reduce or eliminate major sources of error.

Brewer, William V.↗

Non-disruptive error field measurement in DIII-D low safety factor plasmas and projection to ITER

Previous experiments in DIII-D (Paz-Soldan et al 2022 Nucl. Fusion 62 126007) introduced a method to identify intrinsic error fields (EFs) in tokamaks with minimal disruption risk by promptly healing driven magnetic islands during the conventional 'compass scan'. This paper presents recent experimental and numerical advancements in extending this approach to low q 95 plasmas, and projects its applicability to ITER. Non-disruptive EF measurement is achieved at q 95 = 4.5 and 3.9 without any initial EF correction (EFC) by reducing the time between the occurrence of the locked mode (LM) and control action to 10 ms and increasing the density 50%–100%. However, 50% correction of the intrinsic EF is required to achieve island healing at q 95 = 3.2 with 10 ms delay for the control action. Nonlinear two-fluid modeling with the TM1 code reproduces the DIII-D experimental observations, indicating that promptly turning off the 3D coil current reduces both magnetic island width and electromagnetic force, while raising the density increases plasma viscosity, facilitating magnetic island healing. The simulations show that for scenarios with q 95 = 3.2, lowering the control action time to 5 ms will lead to island healing without EFC. TM1 simulations are extended to future ITER scenarios with 5 MA and 7.5 MA plasma currents, predicting the dependence of required density rise on action time and EF amplitude. These simulations indicate that, benefiting from the much longer resistive time, island healing can be successfully achieved in ITER when taking control action 100–500 ms after a LM occurrence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Bit error rate measurement for evaluation of a fiber optic link

Digital fiber-optic data-link terminal modules are being developed in a number of laboratories, and often the modules take the form of black boxes without convenient access to internal signals. This paper discusses types of measurements which can be made using only the digital terminals of the link. Bit-error-rate (BER) vs signal-power data can, of course, provide a means for proving overall link performance, but it can also be used to determine certain internal parameters of the receiver. The theoretical dependence of the BER-vs-light-signal-power curve shape on receiver input-noise equivalent power and comparator slicing level is discussed. BER-vs-light-signal-power measurements obtained with an experimental link are presented and interpreted with the aid of the theoretical curves. The effects of other problems, such as hum or oscillation, on the BER data are mentioned. Sensitivity of the system BER to bit rate is also discussed, with application to determining system operating limits. Since BER measurements are simple to make and can easily be automated, they may prove to be a useful means for either laboratory evaluation or production-line acceptance testing of sealed terminal modules.

Bergman, L. A.↗

SRF Cavity Testing Using a FPGA Self Excited Loop

This document provides a detailed description of procedures for very-high precision calibration and testing of superconducting RF cavities using digital Low-Level RF (LLRF) electronics based on Field Programmable Gate Arrays (FPGA). The use of a Self-Excited Loop with an innovative procedure for fast turn-on allows the measurement of the forward, reflected and transmitted power from a single port of the directional coupler in front of the cavity, thus eliminating certain measurement errors. Various procedures for measuring the quality factor as a function of cavity fields are described, including a single RF pulse technique. Errors are estimated for the measurements.

43 PARTICLE ACCELERATORS↗

Open Source Fault-tolerant Grid Frequency Measurement for Solar Inverters

The Discrete Fourier transform (DFT) based measurement algorithms are one of the most common measurement algorithms for grid parameter estimation such as rms, phase angle, frequency. Over the past few years, many DFT based algorithms have been developed to enhance its measurement accuracy under steady-state and/or dynamic grid conditions. For example, an adaptive band-pass filter utilizing exponential modulation filter has been proposed to reduce measurement errors at the presence of large frequency deviations. Measurement accuracy of different algorithms including FIR filter, extended Kalman filtering (EKF), and enhanced DFT method have been compared in detail under different grid conditions. Two artificial signals that have 90-degree phase difference were constructed by the Clarke transformation to address the frequency spectrum leakage of DFT. A multi-module approach was developed to enhance both steady-state and dynamic measurement accuracies, in which each module was developed to eliminate some specific errors. Besides DFT-based measurement algorithms, some signal model-based algorithms have been developed to further improve the accuracy under dynamic conditions. However, a key drawback of the state-of-the-art algorithms is that they cannot perform measurements accurately during system transient faults. In the Blue Cut Fire event, there was a phase angle jump of about 26 degrees in the voltage waveform during the transient fault. The phase angle jump fault will cause waveform discontinuity, and these algorithms will fail to provide reliable measurements during this period because they typically assume the waveform to be measured is continuous, no matter what method (DFT, PLL, EKF, FIR, or Taylor WLS) is used for estimation. In fact, the measurement errors during the system transient faults like phase-jump is not required in the IEEE Standard. As a result, although a measurement instrument can pass the strict IEEE Standard, it could still be the source of the problem in the future if we have similar system transient faults, which could happen again. Therefore, developing the fault-tolerant measurement technology is the key to solve the problem.

14 SOLAR ENERGY↗

Absolute flux density calibrations: Receiver saturation effects

The effect of receiver saturation was examined for a total power radiometer which uses an ambient load for calibration. Extension to other calibration schemes is indicated. The analysis shows that a monotonic receiver saturation characteristic could cause either positive or negative measurement errors, with polarity depending upon operating conditions. A realistic model of the receiver was made by using a linear-cubic voltage transfer characteristic. The evaluation of measurement error for this model provided a means for correcting radio source measurements.

Freiley, A. J.↗

Error Propagation in Microwave Soil Moisture and Vegetation Optical Depth Retrievals

Satellite soil moisture and vegetation optical depth (VOD; related to the total vegetation water mass per unit area) are increasingly being used to study water relations in the soil-plant continuum across the globe. However, soil moisture and VOD are typically jointly estimated, where errors in the optimization approach can cause compensation between both variables and confound such studies. It is thus critical to quantify how satellite microwave measurement errors propagate into soil moisture and VOD. Such a study is especially important for VOD given limited investigations of whether VOD reflects in-situ plant physiology. Furthermore, despite new approaches that constrain (or regularize) VOD dynamics to reduce soil moisture errors, there is limited study of whether regularization reduces VOD errors without obscuring true vegetation temporal dynamics. Here, we find that, across the globe, VOD is less robust to measurement error (more difficult for optimization methods to find the true solution) than soil moisture in their joint estimation. However, a moderate degree of regularization (via time-constrained VOD) reduces errors in VOD to a greater degree than soil moisture and reduces spurious soil moisture-VOD coupling. Furthermore, despite constraining VOD time dynamics, regularized VOD variations on sub-weekly scales are both closer to simulated true VOD time series and have global VOD post-rainfall responses with reduced error signatures compared to VOD retrievals without regularization. Ultimately, we recommend moderately regularized VOD for use in large scale studies of soil-plant water relations because it suppresses noise and spurious soil moisture-VOD coupling without removing the physical signal.

Vegetation optical depth↗

Information Theoretic Evaluation of Satellite Soil Moisture Retrievals

Microwave radiometry has a long legacy of providing estimates of remotely sensed near surfacesoil moisture measurements over continental and global scales. A consistent assessment of theerrors and uncertainties associated with these retrievals is important for their effective utilization in modeling, data assimilation and end-use application environments. This article presents an evaluationof soil moisture retrieval products from AMSR-E, ASCAT, SMOS, AMSR2 and SMAPinstruments using information theory-based metrics. These metrics rely on time series analysis ofsoil moisture retrievals for estimating the measurement error, level of randomness (entropy) andregularity (complexity) of the data. The results of the study indicate that the measurement errors inthe remote sensing retrievals are significantly larger than that of the ground soil moisture measurements.The SMAP retrievals, on the other hand, were found to have reduced errors (comparable to Preprint submitted to Remote Sensing of Environment October 1, 2017those of in-situ datasets), particularly over areas with moderate vegetation. The SMAP retrievals also demonstrate high information content relative to other retrieval products, with higher levelsof complexity and reduced entropy. Finally, a joint evaluation of the entropy and complexity ofremotely sensed soil moisture products indicates that the information content of the AMSR-E, ASCAT,SMOS and AMSR2 retrievals is low, whereas SMAP retrievals show better performance. The use of information theoretic assessments is effective in quantifying the required levels of improvements needed in the remote sensing soil moisture retrievals to enhance their utility and information content.

Information theory↗

SU-E-T-482: In Vivo Dosimetry of An Anthropomorphic Phantom by Using the RADPOS System for Proton Beam Therapy

Purpose: Delivered doses in an anthropomorphic phantom were evaluated by using the RADPOS system for proton beam therapy. Methods: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing simultaneous online measurements of dose and spatial position. Through the RADPOS system, dose evaluation points can be determined. In vivo proton dosimetry was evaluated by using the RADPOS system and anthropomorphic head and neck phantom. MOSFET doses measured at 3D positions obtained with the RADPOS were compared to the treatment plan values that were calculated by a simplified Monte Carlo (SMC) method. Although the MOSFET response depends strongly on the linear energy transfer (LET) of proton beam, the MOSFET responses to proton beams were corrected with the SMC. Here, the SMC calculated only dose deposition determined by the experimental depth–dose distribution and lateral displacement of protons due to both multiple scattering effect in materials and incident angle. As a Result, the SMC could quickly calculate accurate doses in even heterogeneities. Results: In vivo dosimetry by using the RADPOS, as well as the MOSFET doses agreed in comparison with calculations by the SMC in the range of −3.0% to 8.3%. Most measurement errors occurred because of the uncertainties of dose calculations due to the position error of 1 mm. Conclusion: We evaluated the delivered doses in the anthropomorphic phantom by using the RADPOS system for proton beam therapy. The MOSFET doses agreed in comparison with calculations by the SMC within the measurement error. Therefore, we could successfully control the uncertainties of the measurement positions by using the RADPOS system within 1 mm in in vivo proton dosimetry. We aim for the clinical application of in vivo proton dosimetry with this RADPOS system.

60 APPLIED LIFE SCIENCES↗

Optimum quantisers for a Gaussian input probability density and for the magnitude-error distortion measure

The parameters of non-uniform and uniform quantizers up to ten bits of quantization, optimum for a Gaussian input probability and for the magnitude-error distortion criterion are computed. Optimum quantizers must be understood as quantizers with minimum distortion. The numerical method used for the optimization converges relatively rapidly. The comparison between optimum non-uniform quantizers and optimum uniform quantizers is made.

Demaret, J. C.↗