Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

BM3DORNL

BM3DORNL is a high-performance, open-source library for removing streak and ring artifacts from computed-tomography (CT) data, developed for neutron imaging at Oak Ridge National Laboratory's Spallation Neutron Source (VENUS beamline) and applicable to X-ray CT as well. Ring artifacts — concentric rings in reconstructed slices caused by detector pixel-to-pixel response non-uniformities — appear as vertical streaks in the sinogram and degrade both image quality and quantitative analysis. BM3DORNL operates in the sinogram domain using an adaptation of the BM3D (block-matching and 3D collaborative filtering) algorithm (Dabov et al., 2007). It provides a dedicated streak-removal mode, a true multi-scale BM3D variant (after Mäkinen et al., 2021) that suppresses wide streaks single-scale methods miss, and an alternative Fourier–SVD method (~2.6× faster) combining FFT-based energy detection with rank-1 SVD. The computationally intensive core is implemented in Rust with parallel (Rayon) block matching, integral-image pre-screening, and optimized transforms, and is exposed through a simple Python API (with an optional GUI) so it integrates directly into existing tomography reconstruction pipelines. It processes both 2D sinograms and 3D sinogram stacks, is pip-installable for Linux and macOS, and is documented at https://bm3dornl.readthedocs.io.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

AXEAP (ARGONNE X-RAY EMISSION PACKAGE)

Argonne X-ray Emission Package (AXEAP), a singular purpose software package for processing X-ray emission (XES) images collected with a 2-dimensional position sensitive pixel array detector, has been developed. AXEAP can rapidly convert XES image files into a spectral form by applying parallel computation and unsupervised machine learning to compute vast amount of image data. Special focus has been placed on designing user-friendly-interface for processing multiple edges, non-resonant and resonant x-ray emission image analysis, in order to make data processing quick and easy. AXEAP is free software and is written in MATLAB, armed with powerful libraries and toolboxes. The software runs on all common operating systems such as Linux, Window, and Mac.

SUN, CHENGJUN↗

On-Detector Machine Learning for Beam-Induced Background Rejection at a 10 TeV Muon Collider

A 10 TeV Muon Collider is a compelling candidate for a future energy-frontier facility, offering unprecedented opportunities to explore the fundamental laws of particle physics. Muon decays in the collider ring produce intense beam-induced background (BIB) that can overwhelm detector occupancy and exceed readout bandwidth constraints. We investigate the potential of on-detector Machine Learning for BIB rejection in the vertex detector, exploiting pixel cluster shapes to distinguish background from collision products. We study three classes of lightweight neural-network architectures, and evaluate their implementation feasibility using high-level synthesis. Selected architectures achieve 88 to 90% data reduction at 99% signal efficiency, while requiring hardware resources compatible with potential ASIC implementation. These results demonstrate the potential of performing substantial BIB rejection directly in the pixel readout, providing a strategy for meeting the tracker readout requirements at a future Muon Collider.

Abadjiev, Daniel [Chicago U.]↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗

In-pixel AI for lossy data compression at source for X-ray detectors

Integrating neural networks for data compression directly in the Read-Out Integrated Circuits (ROICs), i.e. the pixelated front-end, would result in a significant reduction in off-chip data transfer, overcoming the I/O bottleneck. Our ROIC test chip (AI-In-Pixel-65) is designed in a 65 nm Low Power CMOS process for the readout of pixelated X-ray detectors. Each pixel consists of an analog front-end for signal processing and a 10b analog-to-digital converter operating at 100KSPS. Here, we compare two non-reconfigurable techniques, Principal Component Analysis (PCA) and an AutoEncoder (AE) as lossy data compression engines implemented within the pixelated area. The PCA algorithm achieves 50$×$ compression, adds one clock cycle latency, and results in a 21% increase in the pixel area. The AE achieves 70$×$ compression, adds 30 clock cycle latency, and results in a similar area increase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass2021 CMB-HD White Paper

CMB-HD is a proposed millimeter-wave survey over half the sky that would be ultra-deep (0.5 uK-arcmin) and have unprecedented resolution (15 arcseconds at 150 GHz). Such a survey would answer many outstanding questions about the fundamental physics of the Universe. Major advances would be 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k~10 h Mpc^(-1)), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and velocity, another probe of cosmic structure. In addition, CMB-HD would allow us to cross critical thresholds: 3.) ruling out or detecting any new, light (< 0.1 eV) particles that were in thermal equilibrium with known particles in the early Universe, 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe, and 5.) ruling out or detecting inflationary magnetic fields. CMB-HD would also provide world-leading constraints on 6.) axion-like particles, 7.) cosmic birefringence, 8.) the sum of the neutrino masses, and 9.) the dark energy equation of state. The CMB-HD survey would be delivered in 7.5 years of observing 20,000 square degrees of sky, using two new 30-meter-class off-axis crossed Dragone telescopes to be located at Cerro Toco in the Atacama Desert. Each telescope would field 800,000 detectors (200,000 pixels), for a total of 1.6 million detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Calibrating LArPix for TinyTPC

LArTPCs provide sensitivity to GeV signals, such as accelerator neutrinos and part of the supernova neutrino spectrum. TinyTPC is a LArTPC test stand for R&D of LAr doping to expand the reach of LArTPCs down to the 1-10 MeV range, which would substantially enhance the flagship analyses of experiments like DUNE, while enabling low energy analyses. We aim to dope LAr with Xe and pho- tosensitive dopants to expand the LArTPC range by converting hard-to-detect scintillation light to efficiently detected ionization charge. A critical element of the data analysis in TinyTPC is calibrating the readout. This poster will cover the calibration of TinyTPC, a pixelated liquid argon detector, where we find the distance a muon travels through each pixel. We then calculate the energy loss of muons traveling through the detector from cosmic data. We can reconstruct the path of the particles through the TPC using a density-based clustering algorithm designed to sort straight cosmic muon tracks from low energy radioactive decay curled paths and electronic noise

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗