Search NASA⌕ Search

SEARCH · Search NASA

Results for “point of loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensing Electrical Networks Securely & Economically (SENSE)

The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

aggregates↗

Recent Hydrodynamic Modeling Enhancements in OpenFAST: Preprint

To improve the hydrodynamic modeling capabilities of the offshore wind design and modeling tool OpenFAST, a restructuring of the HydroDyn hydrodynamics module was undertaken with several new features implemented. The generation of the wave field is now separated from HydroDyn into a new module called SeaState. Unlike previous versions of HydroDyn, which precomputed the wave kinematics at the undisplaced positions of the hydrodynamic nodes, the new SeaState module computes the complete time history of the wave field at the vertices of a user-defined wave grid. During the simulation, the wave kinematics at any point within the grid can be efficiently interpolated, allowing the strip-theory wave loads to be evaluated based on the wave kinematics at the displaced structure position. A phase correction was also implemented for the potential-flow wave-exciting loads to account for large structure displacements. Several wave-stretching methods were implemented for the strip-theory solution along with a wave-load redistribution method that ensures smooth variation of the nodal loads as the nodes of a discrete hydrodynamic mesh enter and exit the water. The load smoothing is included to avoid the excitation of unphysical high-frequency structural vibration during hydroelastic simulations. The MacCamy-Fuchs diffraction correction for the strip-theory solution and the capability to insert a constrained NewWave into extreme stochastic sea states with directional spreading were also added. The present article documents the formulations of the new improvements to HydroDyn with example applications and numerical results.

constrained wave↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring Saturn's Electron Beam Energy Spectrum using Webb's Wedges

It is very difficult to measure the voltage of the load on the Saturn accelerator. Time-resolved measurements such as vacuum voltmeters and V-dot monitors are impractical at best and completely change the pulsed power behavior at the load at worst. We would like to know the load voltage of the machine so that we could correctly model the radiation transport and tune our x-ray unfold methodology and circuit simulations of the accelerator. Step wedges have been used for decades as a tool to measure the end - point energies of high energy particle beams. Typically, the technique is used for multi-megavolt accelerators, but we have adapted it to Saturn's modest <2 MV end-point energy and modified the standard bremsstrahlung x-ray source to extract the electron beam without changing the physics of the load region. We found clear evidence of high energy electrons >2 MV. We also attempted to unfold an electron energy spectrum using a machine learning algorithm and while these results come with large uncertainties, they qualitatively agree with PIC simulation results.

43 PARTICLE ACCELERATORS↗

National Spherical Torus eXperiment - Upgrade NSTX-U: Structural Analysis of Passive Plates Support Brackets

The objective of this analysis is to estimate and assess the stresses in the passive plates caused by a limiting plasma disruption. The objective of this calculation is also to address observed damage to mounting hardware after completion of NSTX operation. These observations initiated diagnostic efforts during the Upgrade project to monitor the severity of the disruptions that were causing the damage, and planned instrumentation to trend the behavior of the mounting hardware. The Recovery Project mission for the passive plate hardware is to appropriately reinforce the passive plates with stainless steel ribs mounted on the back of the plate to reduce their flexure and stress and reinforcements of the “biscuit” components of the bracketry to transfer loads without damage to bolts, biscuits, and bracket plates and welds. Mid-plane disruptions and quenches were manageable with NSTX vintage hardware. The Vertical Displacement Event (VDE) disruptions position the plasma closer to the passive plates and are more severe than the centered plasma. Earlier work pointed to the P1-P5 VDE as limiting. This has been confirmed by A. Brooks work in support of the load generation effort in reference. During vertical displacement large counter currents are generated in the plate as the plasma approaches it. - as would be expected from passive plates. When the plasma disrupts the currents in the plates are reversed, which also reverses the loading on the plates. This report documents the methodology and results of transient structural analysis on the plasma, passive plates support brackets. The loads induced by eddy and halo currents have been considered, and were generated using a separate electromagnetic analysis (NSTXU_1_11_2_1_CALC_051). The structural model also incorporates the effects from preload. Calculation was performed with the assumption that existing biscuits are not participating in the load bearing except the biscuits connected to jumper bolts, which are fully engaged. Results show that with the planned reinforcements, Passive plates and mounting structures satisfy static and fatigue criteria in all areas except welds, where separate analysis was performed. Both symmetric and asymmetric (with locating block) designs were analyzed, and although stresses were higher without locating block they still satisfy NSTX design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Detection of Future Cyber-Enabled DSM Data Attacks

Demand-Side Management (DSM) is an essential tool to ensure power system reliability and stability. In future smart grids, certain portions of a customer’s load usage could be under the automatic control of a cyber-enabled DSM program, which selectively schedules loads as a function of electricity prices to improve power balance and grid stability. In this scenario, the security of DSM cyberinfrastructure will be critical as advanced metering infrastructure and communication systems are susceptible to cyber-attacks. Such attacks, in the form of false data injections, can manipulate customer load profiles and cause metering chaos and energy losses in the grid. The feedback mechanism between load management on the consumer side and dynamic price schemes employed by independent system operators can further exacerbate attacks. To study how this feedback mechanism may worsen attacks in future cyber-enabled DSM programs, we propose a novel mathematical framework for (i) modeling the nonlinear relationship between load management and real-time pricing, (ii) simulating residential load data and prices, (iii) creating cyber-attacks, and (iv) detecting said attacks. In this framework, we first develop time-series forecasts to model load demand and use them as inputs to an elasticity model for the price-demand relationship in the DSM loop. This work then investigates the behavior of such a feedback loop under intentional cyber-attacks. We simulate and examine load-price data under different DSM-participation levels with three types of random additive attacks: ramp, sudden, and point attacks. We conduct two investigations for the detection of DSM attacks. The first studies a supervised learning approach, with various classification models, and the second studies the performance of parametric and nonparametric change point detectors. Results conclude that higher amounts of DSM participation can exacerbate ramp and sudden attacks leading to better detection of such attacks, especially with supervised learning classifiers. We also find that nonparametric detection outperforms parametric for smaller user pools, and random point attacks are the hardest to detect with any method.

97 MATHEMATICS AND COMPUTING↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

High compressive energy absorption and shape recovery behavior of additively manufactured textile-inspired cylindrical braided metamaterials

Mechanical metamaterials (MMs) are engineered structures with unique mechanical properties that arise from their unique spatial arrangement or lattice-like structure. The most commonly designed MMs such as honeycomb and re-entrant auxetics are prone to failure at the sharp corners and weak joints due to the increased stress concentration under deformation. To mitigate this challenge, braided MM structures involving intertwining threads of nylon—forming curved unit cells—have been studied. These textile-inspired cylindrical braided metamaterials (CBMMs) with contrasting unit cells, namely diamond and regular CBMMs, were fabricated by 3D printing. The layer-by-layer deposited structure built by fused filament fabrication delivered an assembly of overlapped threads that are fused at the contact point. To understand deformation behavior of these MMs, finite element models were developed for various load scenarios including quasi-static compression, cyclic and creep loads at room temperature. Stress distribution, deformation mechanisms, and failure modes were analyzed and validated by experiments to analyze the geometries and associated performance. The diamond CBMMs showed stress softening at 30 % compressive strain, withstanding a load of ∼440 N, whereas the regular CBMMs at 50 % strain experienced ∼250 N. The diamond CBMMs delivered higher creep resistance under sustained load and better energy absorption under cyclic loading than the regular CBMMs. The latter, however, exhibited 94 % shape recovery in contrast to 88 % recovery in former prototype during their first cyclic load. In conclusion, this study helps design mechanical lightweight devices that endure significant sustained load and exhibit enhanced energy absorption and shape recovery characteristics in cyclic loading.

Creep↗

Estimating source-sink distributions and fluxes of reactive nitrogen and sulfur within a mixed forest canopy

The vertical source-sink distribution of air pollutants within and above forested canopies is necessary for describing the biological, physical, and chemical processes influencing the soil-vegetation-atmosphere exchange. Here, this study implemented inverse modeling methods to estimate the source-sink and flux profiles of reactive nitrogen (N) and sulfur (S) compounds from measurements of the mean concentration profiles of ammonia (NH 3 ), nitric acid (HNO 3 ), sulfur dioxide (SO 2 ), and particulate ammonium (NH 4 + ), nitrate (NO 3 − ), and sulfate (SO 4 2− ) at a forest site in the southern Appalachian Mountains. Three inverse approaches utilizing different approximations to scalar transport within the canopy were developed and evaluated against sensible heat flux measurements. The Eulerian model (EUL), which incorporates vertical velocity skewness, performed well in reproducing the turbulent heat fluxes and was subsequently used to calculate the chemical source-sink and flux profiles. Above-canopy fluxes of NH 3 were downward, indicating that the forest was a net sink of NH 3 . The soil/litter layer was both a source and a sink for NH 3 but the exchange rate at the forest floor was small. Fluxes of HNO 3 , SO 2 , NO 3 − , NH 4 + , and SO 4 2- were uni-directional (deposition only) between the air and the canopy/ground and increased monotonically from the forest floor to the canopy top. Crown foliage dominated the uptake of reactive N and S during the growing season, accounting for 80–90% of the total canopy-scale flux. Fluxes and canopy-ground partitioning estimated using the resistance-based Surface Tiled Aerosol and Gas Exchange (STAGE) model were generally comparable to EUL. The comparison highlights the need for improved parameterizations of litter exchange and NH 3 compensation points in resistance models for forest ecosystems. The findings here benefit the application of critical loads in forest ecosystems and guide further development of resistance-based exchange models.

54 ENVIRONMENTAL SCIENCES↗

Thermoplastic Polymer from Lignin: Creating an Extended Polyamide Network through Reactive Kraft Lignin Derivatives

Thermoplastic polymers have many desirable properties for consumer applications and are complemented by efficient thermal processing techniques, reducing the cost of manufacturing. Lignin exists as an immense biobased carbon source but has largely been researched for its use in thermoset materials due to its own cross-linked, polyfunctional nature. In this study, a new reaction design is employed to create a thermoplastic polyamide network incorporating lignin that is tested to be 99% biobased carbon by radiocarbon analysis. Chemical analysis reveals the nature of lignin incorporation based on chain extension and cross-linking models. The thermal and rheological properties of the new polymers are thoroughly investigated to demonstrate the higher melt-strength capability of the lignin-based polymers facilitating their use in modern processing equipment. This analysis results in finding an optimal lignin loading ratio in the polymer composition reflected by improved tensile strength and stiffness. The results point to a promising polymer design for applying industrial kraft lignin in high-value thermoplastic polymer applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origins of the change in mechanical strength of silicon/gold nanocomposites during irradiation

Abstract Silicon-based layered nanocomposites, comprised of covalent-metal interfaces, have demonstrated elevated resistance to radiation. The amorphization of the crystalline silicon sublayer during irradiation and/or heating can provide an additional mechanism for accommodating irradiation-induced defects. In this study, we investigated the mechanical strength of irradiated Si-based nanocomposites using atomistic modeling. We first examined dose effects on the defect evolution mechanisms near silicon-gold crystalline and amorphous interfaces. Our simulations reveal the growth of an emergent amorphous interfacial layer with increasing dose, a dominant factor mitigating radiation damage. We then examined the effect of radiation on the mechanical strength of silicon-gold multilayers by constructing yield surfaces. These results demonstrate a rapid onset strength loss with dose. Nearly identical behavior is observed in bulk gold, a phenomenon that can be rooted to the formation of radiation-induced stacking fault tetrahedra which dominate the dislocation emission mechanism during mechanical loading. Taken together, these results advance our understanding of the interaction between radiation-induced point defects and metal-covalent interfaces.

36 MATERIALS SCIENCE↗

All solid thick oxide cathodes based on low temperature sintering for high energy solid batteries

Solid-state batteries (SSBs) could significantly improve the safety and energy density over conventional liquid cells. One key enabling technology is the use of solid electrolytes. NASICON-type Li 1.3 Al 0.3 Ti 1.7 (PO 4 ) 3 (LATP) is a very attractive solid-state electrolyte for the cathode side due to its high oxidation potential and high ionic conductivity. The usage, however, is limited by its large interfacial resistance against most of the cathode materials as well as the thermodynamic instability during high temperature sintering needed to achieve high mass density. Here we construct thin, percolative, and mixed conductive interphases through in situ low-melting-point liquid sintering. These mixed conductive interphases drastically improve the kinetics, leading to high-loading solid LATP/LiCoO 2 cathodes achieving capacity loading of up to ~6 mA h cm –2 . The technique is also applicable to Ni-rich cathode materials, achieving up to ~10 mAh cm –2 , which can lead to more than 400 W h kg –1 cells in SSBs. Furthermore, our composite cathodes show a ten-times and three-times area capacity improvement over the state-of-the-art cathodes using oxide and sulfide SSEs, respectively.

25 ENERGY STORAGE↗

Data-Efficient Dimensionality Reduction and Surrogate Modeling of High-Dimensional Stress Fields

Tensor datatypes representing field variables like stress, displacement, velocity, etc., have increasingly become a common occurrence in data-driven modeling and analysis of simulations. Numerous methods [such as convolutional neural networks (CNNs)] exist to address the meta-modeling of field data from simulations. As the complexity of the simulation increases, so does the cost of acquisition, leading to limited data scenarios. Modeling of tensor datatypes under limited data scenarios remains a hindrance for engineering applications. Here, in this article, we introduce a direct image-to-image modeling framework of convolutional autoencoders enhanced by information bottleneck loss function to tackle the tensor data types with limited data. The information bottleneck method penalizes the nuisance information in the latent space while maximizing relevant information making it robust for limited data scenarios. The entire neural network framework is further combined with robust hyperparameter optimization. We perform numerical studies to compare the predictive performance of the proposed method with a dimensionality reduction-based surrogate modeling framework on a representative linear elastic ellipsoidal void problem with uniaxial loading. The data structure focuses on the low-data regime (fewer than 100 data points) and includes the parameterized geometry of the ellipsoidal void as the input and the predicted stress field as the output. The results of the numerical studies show that the information bottleneck approach yields improved overall accuracy and more precise prediction of the extremes of the stress field. Additionally, an in-depth analysis is carried out to elucidate the information compression behavior of the proposed framework.

artificial intelligence↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Toward holistic understanding of the ITER-like resonant magnetic perturbation (RMP) ELM control on KSTAR

Here, KSTAR has clarified a set of unresolved 3D physics issues utilizing the ITER-like in-vessel, three-row, resonant magnetic perturbation (RMP) configurations. Since RMP-driven, edge-localized-modes (ELMs)-crash control elevates the divertor heat flux peak through its impact on edge plasma parameters and transport, a series of intentionally misaligned RMP configurations (IMCs) have been explored to investigate the relationship between RMP ELM control and divertor heat fluxes, while searching for an ideal IMC that could be favorable in both aspects. First of all, the contrasting influence of kink vs anti-kink phasing on the ELM-crash suppression has been articulated, demonstrating the synergistic benefit of 'kink' phasing on ELM-crash-suppression. On the other hand, the three-row IMC in the anti-kink phasing becomes more insensitive to the ELM-crashes at the sub-marginal level of RMP, consistent with theory. Meanwhile, the divertor 'wetted' area of ELM-crash-suppression gets narrower than that of ELM-crash-mitigation, suggesting that ELM-crash-mitigation remains advantageous over ELM-crash-suppression in terms of time-averaged divertor thermal loading. In comparison, based on a set of two-row IMCs, no evidence of divertor heat flux broadening was found during ELM-crash-suppression, supporting a hypothesis that the dispersal of the divertor heat flux in three-row IMCs cannot be driven by helically structured two-row RMPs alone. Among ITER-like three-rows, lower two-row RMPs have been found to be much more effective in suppressing the ELM-crashes than upper two-row RMPs. Although it is quite preliminary, the up/down asymmetric dependence of RMP coupling may be generically attributed to lower-single-null plasmas. Such a holistic understanding of RMP-driven, ELM-crash-control in KSTAR is expected not only to elucidate various subtle points in the vicinity of ELM-crash-suppression, but also to clarify the relevant divertor thermal loading issues for ITER and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗