Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow initialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Hydrodynamic and magnetohydrodynamic simulations of wire turbulence

In this paper, we report on simulations of laboratory experiments in which magnetized supersonic flows are driven through a wire mesh. The goal of the study was to investigate the ability of such a configuration to generate supersonic, MHD turbulence. We first report on the morphological structures that develop in both magnetized and non-magnetized cases. We then analyze the flow using a variety of statistical measures, including power spectra and probability distribution functions of the density. Using these results we estimate the sonic mach number in the flows downstream of the wire mesh. Finally, we find the initially hypersonic (M s = 20) planar shock through the wire mesh does lead to downstream turbulent conditions. However, in both magnetized and non-magnetized cases, the resultant turbulence was marginally supersonic to transonic (M s ~1), and highly anisotropic in structure.

(Magnetohydrodynamics) MHD↗

Polarized 3He gas circulating technologies for neutron analyzers

We outline our project to develop a circulating polarized helium-3 system for developing of large, quasi-continuously operating neutron analyzers. The project consisted of four areas: 1) Development of robust external cavity narrowed diode laser output with spectral line width < 0.17 nm and power of 2000 W. 2) Development of large glass polarizing cells using cell surface treatments to obtain long relaxation lifetimes. 3) Refinements of the circulation system with an emphasis on gas purification and materials testing. 4) Design/fabrication of a new polarizer system. 5) Preliminary testing of the new polarizer. 1. Developed Robust High-Power Narrowed Laser The optical configuration of the laser was discussed in the proposal and will be reviewed in the body of this report. The external cavity is configured to mutually lock the wavelength of five 10-bar laser stacks. All the logistical milestones were been met and critical subsystems- laser stack manifold and power divider, external laser cavity, and output telescope- were assembled and tested at low power. Each individual bar is narrowed to ~0.05 nm; when combined the laser has a cumulative spectral width of 0.17 nm across the entire beam due to variations of the bars central wavelength by +/- 0.1 nm, which is similar to that of Volume Bragg Grating narrowed laser bars. This configuration eliminates the free-running “pedestal” that occurs in other external cavity diode lasers. The full-scale laser was completed in 2016 and was used in both the older and newer helium polarizers. This laser was operated at 75% power for periods of up to 8 hours. Once installed, the spectrum became slightly broader (~.25 nm) at full power; this is likely due to very slight misalignments that occurred during handling. 2. Developed the processes to create uniform sintered sol-gel coatings. Our work on cell development comprised: 1) Production of large GE180 cells and explore different means of cell preparation, and 2) Development of apply sol-gel coatings to the interior of both borosilicate and aluminosilicate cells. We applied six sol-gel coatings. By modifying the mixture and developing procedures to drain and dry the cell, we produced visually uniform coatings on the interior of the cells. We now have perfected that process as described below in our report. We were able to accelerate the testing of cells using an ex situ method that avoids installing each cell into a polarizer. In the project’s last year, we conducted 38 external tests of 8 different cells. We also installed two sol-gel coated cells in our polarizers. We created cell with long ex situ relaxation lifetimes, one of which exceeded 40 hours. However, when installed in the polarizer the measured lifetime is 8 hours or less. 3. Demonstrated cycling of polarized gas and ex situ cell testing We are now cycling polarized gas from the polarizer to glass vessels and back. This has allowed us, for the first time, to make ex situ T1 measurements of polarizing cells without installing them into the polarizer itself. This has greatly improved our productivity in producing cells and evaluating our cell preparation processes. We continued development of the gas handling system in parallel with fabricating new polarizer. The integrated system was tested by the end of 2016. We now regularly cycle gas into and out of the polarizer. 4. Completed new polarizer infrastructure and control systems. We completed the new polarizer infrastructure in November 2016. The polarizer subsystems are 1) the frame, 2) the oil flow system, 3) the gas handling system, 4) the pressure vessel, with embedded solenoid, 5) cell mounting hardware with heat spreaders, and 6) electrical power and instrumentation. 5. Carried out initial tests of polarizer. We completed initial testing of the polarizer in April and May of 2017. These tests were carried out for periods up to 6 hours with laser power between 750 and 1300 Watts. The laser performed well and the polarization with asymptotic to 45 percent, which was below expectations. This low value resulted from a stationary thermal inversion in the cell that caused most of the laser power to be absorbed near the laser inlet window and deprived the lower portions of the cell of pumping laser light. Possible solutions to this problem include enhanced cooling of the cell near the laser entry and slight detuning of the laser. 6. Ongoing work. Our polarizer development efforts are ongoing to pursue our interest in neutron analyzers, nuclear targets, and providing helium for medical imaging. Current tests in the pipeline include: 1. Testing cooling enhancements to improve laser penetration of spectrally narrow lasers; 2. Testing of a cell with isolation valves that minimizes diffusive contact with gas handling hardware during polarization; 3. Testing of smaller hybrid cells with reduced alkali loading; 4. Producing polarized helium-3 for MRI imaging at the University of Missouri.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analyzing Custom Proof Masses and Quantum Limits of a Manufacturable Cavity Optical Levitation Solution

This report details results of a one-year LDRD to understand the dynamics, figures of merit, and fabrication possibilities for levitating a micro-scale, disk-shaped dielectric in an optical field. Important metrics are the stability, positional uncertainty, and required optical power to maintain levitation. Much of the results are contained in a publication written by our academic alliance collaborators. Initial structures were grown at Sandia labs and a test fabrication flow was executed. Owing to our strength in VCSEL lasers, we were particularly interested in calculations and fabrication flows that could be compatible with a VCSEL light source.

42 ENGINEERING↗

Atmospheric cloud physics laboratory project study

Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.

Schultz, W. E.↗

Impacts in Ice: Commissions of Solar System Crater Populations

The classical phases of cratering are compression, excavation, and modification. Recent theory, however, supports and alternative sequence of physical events: (1) coupling - energy and momentum are transferred, and the cratering flow field is set up; (2) power-law-growth the flow field expands, with transient cavity dimensions expressible as a simple power law function of time; and (3) late phase - some combination of gravity, strength, and viscosity limits cavity growth, initially causing a deviation from power-law behavior and eventually determining the size and shape of the final (transient) crater. The dominant mechanism that limits cavity growth defines a cratering regime and a single variable, the coupling parameter, determines the scaling laws in the various regimes. The coupling parameter is intermediate in dimensionality between energy and momentum and its exact form is determined. For simple materials with rate and scale independent strength, the transition crater diameter between the strength and gravity regimes is, within reasonable bounds, independent of velocity. Even the smallest craters observed by Voyager appear to be gravity dominated.

Mckinnon, W. B.↗

Internal Flows in Free Drops (IFFD)

Within the framework of an Earth-based research task investigating the internal flows within freely levitated drops, a low-gravity technology development experiment has been designed and carried out within the NASA Glovebox facility during the STS-83 and STS-94 Shuttle flights (MSL-1 mission). The goal was narrowly defined as the assessment of the capabilities of a resonant single-axis ultrasonic levitator to stably position free drops in the Shuttle environment with a precision required for the detailed measurement of internal flows. The results of this entirely crew-operated investigation indicate that the approach is fundamentally sound, but also that the ultimate stability of the positioning is highly dependent on the residual acceleration characteristic of the Spacecraft, and to a certain extent, on the initial drop deployment of the drop. The principal results are: the measured dependence of the residual drop rotation and equilibrium drop shape on the ultrasonic power level, the experimental evaluation of the typical drop translational stability in a realistic low-gravity environment, and the semi-quantitative evaluation of background internal flows within quasi-isothermal drops. Based on these results, we conclude that the successful design of a full-scale Microgravity experiment is possible, and would allow accurate the measurement of thermocapillary flows within transparent drops. The need has been demonstrated, however, for the capability for accurately deploying the drop, for a quiescent environment, and for precise mechanical adjustments of the levitator.

Trinh, E. H.↗

Can standard cosmological models explain the observed Abell cluster bulk flow?

Lauer and Postman (LP) observed that all Abell clusters with redshifts less than 15,000 km/s appear to be participating in a bulk flow of 689 km/s with respect to the cosmic microwave background. We find this result difficult to reconcile with all popular models for large-scale structure formation that assume Gaussian initial conditions. This conclusion is based on Monte Carlo realizations of the LP data, drawn from large particle-mesh N-body simulations for six different models of the initial power spectrum (standard, tilted, and Omega(sub 0) = 0.3 cold dark matter, and two variants of the primordial baryon isocurvature model). We have taken special care to treat properly the longest-wavelength components of the power spectra. The simulations are sampled, 'observed,' and analyzed as identically as possible to the LP cluster sample. Large-scale bulk flows as measured from clusters in the simulations are in excellent agreement with those measured from the grid: the clusters do not exhibit any strong velocity bias on large scales. Bulk flows with amplitude as large as that reported by LP are not uncommon in the Monte Carlo data stes; the distribution of measured bulk flows before error bias subtraction is rougly Maxwellian, with a peak around 400 km/s. However the chi squared of the observed bulk flow, taking into account the anisotropy of the error ellipsoid, is much more difficult to match in the simulations. The models examined are ruled out at confidence levels between 94% and 98%.

Strauss, Michael A.↗

USM3D Simulations of Saturn V Plume Induced Flow Separation

The NASA Constellation Program included the Ares V heavy lift cargo vehicle. During the design stage, engineers questioned if the Plume Induced Flow Separation (PIFS) that occurred along Saturn V rocket during moon missions at some flight conditions, would also plague the newly proposed rocket. Computational fluid dynamics (CFD) was offered as a tool for initiating the investigation of PIFS along the Ares V rocket. However, CFD best practice guidelines were not available for such an investigation. In an effort to establish a CFD process and define guidelines for Ares V powered simulations, the Saturn V vehicle was used because PIFS flight data existed. The ideal gas, computational flow solver USM3D was evaluated for its viability in computing PIFS along the Saturn V vehicle with F-1 engines firing. Solutions were computed at supersonic freestream conditions, zero degree angle of attack, zero degree sideslip, and at flight Reynolds numbers. The effects of solution sensitivity to grid refinement, turbulence models, and the engine boundary conditions on the predicted PIFS distance along the Saturn V were discussed and compared to flight data from the Apollo 11 mission AS-506.

Deere, Karen↗

Uniform redundancy allocation maximizes the robustness of flow networks against cascading failures

We study the robustness of flow networks against cascading failures under a partial load redistribution model. In particular, we consider a flow network of N lines with initial loads L 1 ,...,L N and free spaces (i.e., redundant space) S 1 ,...,S N that are independent and identically distributed with joint distribution P LS (x,y) = P[L ≤ x, S ≤ y]. The capacity C i is the maximum load allowed on line i and is given by C i = L i + S i . Furthermore, when a line fails due to overloading, it is removed from the system and (1 – ε) fraction of the load it was carrying is redistributed equally among all remaining lines in the system. The rest (i.e., ε fraction) of the load is assumed to be lost or absorbed, e.g., due to advanced circuitry disconnecting overloaded power lines or an interconnected network or material absorbing a fraction of the flow from overloaded lines. We analyze the robustness of this flow network against random attacks that remove a p fraction of the lines. Our contributions include (i) deriving the final fraction of alive lines n ∞ (p,ε) for all p,εϵ(0,1) and confirming the results via extensive simulations; (ii) showing that partial redistribution might lead to (depending on the parameter 0 < ε ≤ 1) the order of transition at the critical attack size p* changing from first to second-order; and (iii) proving analytically that flow networks achieve maximum robustness [quantified by the area ∫$^{1}_{0}$ n ∞ (p,ε)dp] when all lines have the same free space regardless of their initial load. The optimality of equal free-space allocation is also confirmed on real-world data from the UK National Power Grid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dissecting the role of initial collision geometry for jet quenching observables in relativistic heavy ion collisions

The observation of large azimuthal anisotropy or v{sub 2} for hadrons above p{sub T} > 5 GeV/c in Au+Au collisions at {radical}s{sub nn} = 200 GeV has been a longstanding challenge for jet quenching models based on perturbative QCD (pQCD). Using a simple jet absorption model, we seek to clarify the situation by exploring in detail how the calculated v{sub 2} varies with choices of the collision geometry as well as choices of the path length dependence and thermalization time {tau}{sub 0} in the energy loss formula. Besides the change of eccentricity due to distortion from gluon saturation or event-by-event fluctuation, we find that the v{sub 2} is also sensitive to the centrality dependence of multiplicity and the relative size between the matter profile and the jet profile. We find that the v{sub 2} calculated for the naive quadratic path length dependence of energy loss, even including eccentricity fluctuation and the gluon saturation, is not enough to describe the experimental data at high p{sub T} ({approx} 6 GeV/c) in Au+Au collisions. However, it can match the full centrality dependence of v{sub 2} data if higher power path length dependence of energy loss is allowed. We also find that the calculated v{sub 2} is sensitive to the assumption of the early time dynamics but generally increases with {tau}{sub 0}, opposite to what one expects for elliptic flow. This study attests to the importance of confining the initial geometry, possibly by combining jet quenching v{sub 2} with elliptic flow and other jet quenching observables, for proper interpretation of the experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of dewar and transfer line cooldown in Superfluid Helium On-Orbit Transfer Flight Experiment (SHOOT)

The Superfluid Helium On-Orbit Transfer Flight Experiment (SHOOT) is designed to demonstrate the techniques and components required for orbital superfluid (He II) replenishment of observatories and satellites. One of the tasks planned in the experiment is to cool a warm cryogen tank and a warm transfer line to liquid helium temperature. A math model, based on single-phase vapor flow heat transfer, has been developed to predict the cooldown time, component temperature histories, and helium consumption rate, for various initial conditions of the components and for the thermomechanical pump heater powers of 2 W and 0.5 W. This paper discusses the model and the analytical results, which can be used for planning the experiment operations and determining the pump heater power required for the cooldown operation.

Ng, Y. S.↗

A Quantitative Evaluation of Dissolved Oxygen Instrumentation

The implications of the presence of dissolved oxygen in water are discussed in terms of its deleterious or beneficial effects, depending on the functional consequences to those affected, e.g., the industrialist, the oceanographer, and the ecologist. The paper is devoted primarily to an examination of the performance of five commercially available dissolved oxygen meters. The design of each is briefly reviewed and ease or difficulty of use in the field described. Specifically, the evaluation program treated a number of parameters and user considerations including an initial check and trial calibration for each instrument and a discussion of the measurement methodology employed. Detailed test results are given relating to the effects of primary power variation, water-flow sensitivity, response time, relative accuracy of dissolved-oxygen readout, temperature accuracy (for those instruments which included this feature), error and repeatability, stability, pressure and other environmental effects, and test results obtained in the field. Overall instrument performance is summarized comparatively by chart.

Pijanowski, Barbara S.↗

Systems Innovation: Modernization & Efficiencies for ESH&Q Reviews

Environmental compliance reviews at INL have traditionally been managed through fragmented systems, relying on multiple spreadsheets and manual processes. This inefficiency led to time-consuming status updates and redundant tasks, such as manually sending reminder emails and transferring data from Excel to the Environmental Review Process (ERP). Initial attempts to streamline these processes using Power Automate and Excel revealed significant limitations, necessitating a more comprehensive solution. To address these immediate inefficiencies, automated workflows were developed using Power Automate. These workflows were designed to send scheduled status update reminders and capture responses through standardized forms, with submitted data flowing directly into centralized Excel trackers. This automation reduced the administrative burden, improved data accuracy, and enabled faster, more consistent reporting. Specifically, email automation achieved a 65% efficiency gain, while data integration saw a 48% improvement, resulting in 91% of project statuses being updated within two months. Despite the improvements brought by Power Automate, the fragmented nature of the review processes persisted. To further enhance efficiency and accuracy, the Integrated Review Tool (IRT) was developed. The IRT aims to centralize review initiation and connect team systems, creating an interconnected data infrastructure that preserves team autonomy while enhancing overall efficiency. This tool automates email reminders, centralizes reviews, and streamlines data integration, significantly improving the accuracy and efficiency of environmental compliance reviews. The design and development of the IRT involved advanced systems methodology, process mapping, project management, and collaboration with subject matter experts. The minimum viable product design is 100% complete, and system development is currently underway, with expected outcomes including a centralized entry point for all ESH&Q reviews, automated routing, real-time tracking and analytics, AI integration, and a user-friendly interface. This project demonstrates the potential of leveraging automation and integrated systems to enhance efficiency, accuracy, and decision-making in environmental reporting and compliance processes at INL.

99 - GENERAL AND MISCELLANEOUS↗

Improved Heat Transfer and Volume Scaling through Novel Heater Design

In 2014, the University of California, Berkeley, Nuclear Engineering Thermal Hydraulics Laboratory completed construction of the Compact Integral Effects Test (CIET) facility, a scaled thermal hydraulics scaled integral effects test facility designed to model the Mark-1 pebble-bed fluoride-salt-cooled high-temperature reactor (Mk1 PB-FHR or simply Mk1). CIET uses an organic simulant fluid, Dowtherm A, to match the Prandtl, Reynolds, Froude, and Grashof numbers of important fluoride salt candidates for molten salt reactors, such as flibe. The FHR reactor core is simulated using a resistively heated tube, which heats the oil flowing through the annulus between the heated tube and a non-heated inner tube. However, the volume fraction of the coolant in the CIET heater was dramatically lower than the volume fraction of the primary coolant in the Mk1 PB-FHR design (3% in CIET vs. 17% in Mk1) because the CIET heater was initially scaled to match an earlier FHR design. Also, the maximum core heater power in CIET is limited by the melting point of Teflon components in CIET, approximately 330 deg. C. For conservatism, the CIET heater power is limited to keep the maximum surface temperature of the heater below 250 deg. C. At the nominal mass flow rate of 0.18 kg/s, this power was about 5 kW. A higher heat transfer coefficient from the heater wall to the oil was needed to increase the effective power delivered to the oil. In order to alleviate these two limitations, a new heater insert was designed and constructed for CIET. This new heater insert uses a twisted tape to augment heat transfer. The twisted tape is supported inside a perforated inner tube that has the same diameter as the original inner tube of the heater, in order to make it compatible with CIET's original heater design. The heat transfer and pressure drop properties of the new heater insert designs were tested in CIET and compared to the previous design in terms of pressure drop and convective heat transfer coefficient. The new heater inserts are intended to increase the range of power levels and mass flow rates that can be tested in CIET in order to augment understanding of FHR thermal hydraulic phenomena. Also, obtaining different data points for CIET response dynamics under different heater coolant residence times will be valuable in evaluating the Mk1 design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗

Additive Manufacturing for Powering the Blue Economy Applications: A Tidal Turbine Blade Case Study: Preprint

As the marine renewable energy industry continues to expand, innovation in the manufacturing space must grow accordingly to reduce costs and ensure the economic feasibility of new technologies. Additive manufacturing, more commonly known as 3D printing, provides an alternative for rapid prototyping of marine hydrokinetic technologies, particularly supporting Powering the Blue Economy initiatives of the U.S. Department of Energy Water Power Technologies Office. This study explores the application of additive manufacturing in the development of marine hydrokinetic structures, focusing on material and printing method selection, design, and analysis of a 3D-printed spar for an axial-flow tidal turbine blade. Corrosion-resistant metals were deemed ideal due to the loads and harsh marine environment the blade would experience. Laser metal deposition methods were determined to be the most effective and scalable for the considered scale. The designed spar adapts its geometry to the blade - a feature uniquely suited to additive manufacturing - and is intended to serve as the blade's primary structural component. A finite element model was used to study stresses and deformations under loading conditions. The spar was manufactured using 316L stainless steel through direct energy deposition, and defects were assessed and recorded. Future efforts will include mechanical testing of the spar. This research establishes a benchmark process for using additive manufacturing in developing marine hydrokinetic structures, paving the way for future optimization and techno-economic analysis.

additive manufacturing↗

Modeling creep behavior in ceramic matrix composites

Here, in this work, a three-dimensional viscoplasticity formulation with progressive damage is developed and used to investigate the complex time-dependent constituent load transfer and progressive damage behavior in ceramic matrix composites (CMCs) subjected to creep. The viscoplasticity formulation is based on Hill's orthotropic plastic potential, an associative flow rule, and the Norton-Bailey creep power law with Arrhenius temperature dependence. A fracture mechanics-informed isotropic matrix damage model is used to account for CMC brittle matrix damage initiation and propagation, in which two scalar damage variables capture the effects of matrix porosity as well as matrix property degradation due to matrix crack initiation and propagation. The Curtin progressive fiber damage model is utilized to simulate progressive fiber failure. The creep-damage formulation is subsequently implemented as a constitutive model in the generalized method of cells (GMC) micromechanics formulation to simulate time-dependent deformation and material damage under creep loading conditions. The developed framework is used to simulate creep of single fiber SiC/SiC microcomposites. Simulation results are in excellent agreement with experimental and numerical data available in the literature.

36 MATERIALS SCIENCE↗