Search NASA⌕ Search

SEARCH · Search NASA

Results for “power processing unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Simplified power processing for ion-thruster subsystems

A review of the thruster/power-processor-interface requirements for (mercury and inert gas) ion-thrusters, an evaluation of various approaches to simplifying the power-processor circuitry, and the test results of the recently developed 8-cm mercury-ion-thruster simplified power-processor unit (SPPU) are presented. The SPPU demonstrates the feasibility of stable thruster operation using highly simplified power-processing techniques and achieves an approximately tenfold reduction in the electronic parts count when compared to the existing power-processor unit (PPU) used in the Hughes/NASA Lewis Research Center 8-cm-diameter (mercury) Ion Auxiliary Propulsion Subsystem (IAPS).

Wessel, F. J.↗

Control Strategies and Validation in the Hybrid Optimization and Performance Platform (HOPP)

The Hybrid Optimization and Performance Platform (HOPP) is a tool that simulates hybrid power plants in various configurations, and also calculates the financial feasibility of these plants. This report outlines an overview of HOPP and the energy storage dispatch strategies available. It then presents three case studies which demonstrate different applications of HOPP. The first case looks at the profitability of hybrid power plants in different locations in the USA. The second case examines the availability of hybrid power plants to provide energy reliability services. The third case presents a plant that produces both hydrogen and electricity, and demonstrates a dispatch strategy that chooses the most profitable energy vector based on price signals. The next section shows the validation of HOPP on operational data, using data from both unit-scale and utility-scale power plants. This validation process demonstrated that HOPP can simulate the power output of both wind and solar PV plants at both scales with comparable fidelity to an existing commercial software tool. Finally, HOPP is applied in a field test which applies an optimal dispatch strategy to a physical battery in a unit-scale hybrid plant at NREL. HOPP's optimal dispatch strategy, applied in a real-world setting, improved this hybrid plant's ability to meet a load signal while minimizing operational costs.

14 SOLAR ENERGY↗

Using Multi-Core Systems for Rover Autonomy

Task Objectives are: (1) Develop and demonstrate key capabilities for rover long-range science operations using multi-core computing, (a) Adapt three rover technologies to execute on SOA multi-core processor (b) Illustrate performance improvements achieved (c) Demonstrate adapted capabilities with rover hardware, (2) Targeting three high-level autonomy technologies (a) Two for onboard data analysis (b) One for onboard command sequencing/planning, (3) Technologies identified as enabling for future missions, (4)Benefits will be measured along several metrics: (a) Execution time / Power requirements (b) Number of data products processed per unit time (c) Solution quality

multi-core↗

Storage peak gas-turbine power unit

A storage gas-turbine power plant using a two-cylinder compressor with intermediate cooling is studied. On the basis of measured characteristics of a .25 Mw compressor computer calculations of the parameters of the loading process of a constant capacity storage unit (05.3 million cu m) were carried out. The required compressor power as a function of time with and without final cooling was computed. Parameters of maximum loading and discharging of the storage unit were calculated, and it was found that for the complete loading of a fully unloaded storage unit, a capacity of 1 to 1.5 million cubic meters is required, depending on the final cooling.

Tsinkotski, B.↗

Scaleup and Site-Specific Engineering Design for Global Thermostat Direct Air Capture Technology

The overall goal of the project is completion of an initial design of a commercial-scale, Carbon Capture, Utilization, and Storage Direct Air Capture (CCUS-DAC) plant design at three different sites that captures a net of at least 100,000 tonnes per year (TPY) carbon dioxide (CO 2 ) from the atmosphere and considers compression and conditioning of the captured CO 2 for purpose of pipeline transportation to different geological formation sites for deep well injection and underground storage. In addition to the leading system consisting of a scaled-up Global Thermostat DAC unit, overall plant design includes a combined Heat and Power (CHP) unit integrated with a conventional liquid amine-based carbon capture system (90% capture) and compression facilities. These are considered balance of plant (BOP) systems and are required to provide low carbon-intensity steam and power to the DAC process. A second approach involving provision of DAC units modified to directly capture emissions from the CHP unit was initially assessed as an alternative and it was determined to be less mature than considered approach and not included in the scaled-up plant design efforts. Three geographically diverse continental United States locations were selected to better understand the effect of local/regional ambient conditions on scaled-up DAC system performance and project costs: Bucks, Alabama (hot wet climate), Odessa, Texas (dry hot climate), and Goose Creek, Illinois (mid continental climate). The team focused on initial engineering design activities, including the development of project design criteria, initiation of site-specific studies and investigations, completion of DAC system process and equipment design, and definition of balance of plant (BOP) engineering. The purpose of the activities were to develop Technoeconomic Analysis (TEA), Life-Cycle Analysis (LCA), and Environmental, Health, and Safety (EH&S) analysis, and Business Case Analysis (BCA) to validate that the project engineering and scale-up plans of the DAC systems, at each of the three distinct case studies considered, are technically, economically, and environmentally feasible for commercial-scale operation.

20 FOSSIL-FUELED POWER PLANTS↗

Green Propulsion Auxiliary Power Unit Demonstration at MSFC

In 2012, the National Aeronautics & Space Administration (NASA) Space Technology Mission Directorate (STMD) began the process of building an integrated technology roadmap, including both technology pull and technology push strategies. Technology Area 1 (TA-01) for Launch Propulsion Systems is one of fourteen TA's that provide recommendations for the overall technology investment strategy and prioritization of NASA's space technology activities. Identified within TA-01 was the need for a green propulsion auxiliary power unit (APU) for hydraulic power by 2015. Engineers led by the author at the Marshall Space Flight Center (MSFC) have been evaluating green propellant alternatives and have begun the development of an APU testbed to demonstrate the feasibility of use. NASA has residual APU assets remaining from the retired Space Shuttle Program. Likewise, the F-16 Falcon fighter jet also uses an Emergency Power Unit (EPU) that has similar characteristics to the NASA hardware. Both EPU's and APU components have been acquired for testing at MSFC. In concert with this effort, ATK has been developing green propellant technology based on the Swedish Space Corp ECAPS LMP-103S propellant. Propellant blending and test facilities have been established at ATK's Elkton MD facility with the intent to provide suitable propellant blends for application to green APU systems as well as thrusters. This paper will summarize the status of the testing efforts with ATK for use of the green propellant LMP-103S based on ammonium dinitramide and use of the Air Force Research Laboratory (AFRL) propellant AF-M315E based on hydroxyl ammonium nitrate with these test assets.

Robinson, Joel W.↗

Green Propulsion Auxiliary Power Unit Demonstration at MSFC

In 2012, the National Aeronautics & Space Administration (NASA) Space Technology Mission Directorate (STMD) began the process of building an integrated technology roadmap, including both technology pull and technology push strategies. Technology Area 1 (TA-01)1 for Launch Propulsion Systems is one of fourteen TAs that provide recommendations for the overall technology investment strategy and prioritization of NASA's space technology activities. Identified within TA-01 was the need for a green propulsion auxiliary power unit (APU) for hydraulic power by 2015. Engineers led by the author at the Marshall Space Flight Center (MSFC) have been evaluating green propellant alternatives and have begun the development of an APU test bed to demonstrate the feasibility of use. NASA has residual APU assets remaining from the retired Space Shuttle Program. Likewise, the F-16 Falcon fighter jet also uses an Emergency Power Unit (EPU) that has similar characteristics to the NASA hardware. Both EPU and APU components have been acquired for testing at MSFC. This paper will summarize the status of the testing efforts of green propellant from the Air Force Research Laboratory (AFRL) propellant AFM315E based on hydroxyl ammonium nitrate (HAN) with these test assets.

Robinson, Joel W.↗

Improving the Nuclear Launch Approval Process; Progress and Plans

Launches involving radioisotope power systems (RPS) or radioisotope heater units (RHU’s) must comply with a number of different statutory, regulatory, and administrative requirements. While some of these are well defined, others have been carried out on the basis of past practice rather than a set of formal standards. In addition, some of the requirements reference outdated standards and are in need of updates. The overall process is also time consuming and expensive. This paper describes efforts by NASA, the Department of Energy (DOE) and others to make improvements to the process while maintaining safety and environmental protection.

McCallum, Peter↗

AMD Radeon e9173 Low Power PCIE GPU Single Event Effects Test Report

The AMD Radeon Embedded e9170 Graphics Processing Unit (GPU), notably the e9173 Peripheral Component Interconnect Express (PCIE) variant, is of interest to Artemis generation programs with requirements for graphics rendering, compute, artificial intelligence (Ai) with a constraints-requiring piece-part procurement and power consumption of less than 50W. In addition to collecting heavy ion data on this device, a secondary purpose of this test campaign was to validate video capture hardware and software workflows used with GPU, microprocessor and system-on-chip device testing. Five (5) test patterns from the NEPP Processor Enclave (NPE) test suite were used with the e9173. The test patterns covered the operating system’s (OS) idle contribution towards the cross section, matrix math using tensorflow-rocm, two artificial intelligence models developed at NASA GSFC, and an industry standard GPU benchmarking application called Mesa GLXGears.

NASA Technical Memorandum (TM) test report for pos↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The design and analysis of single flank transmission error tester for loaded gears

To strengthen the understanding of gear transmission error and to verify mathematical models which predict them, a test stand that will measure the transmission error of gear pairs under design loads has been investigated. While most transmission error testers have been used to test gear pairs under unloaded conditions, the goal of this report was to design and perform dynamic analysis of a unique tester with the capability of measuring the transmission error of gears under load. This test stand will have the capability to continuously load a gear pair at torques up to 16,000 in-lb at shaft speeds from 0 to 5 rpm. Error measurement will be accomplished with high resolution optical encoders and the accompanying signal processing unit from an existing unloaded transmission error tester. Input power to the test gear box will be supplied by a dc torque motor while the load will be applied with a similar torque motor. A dual input, dual output control system will regulate the speed and torque of the system. This control system's accuracy and dynamic response were analyzed and it was determined that proportional plus derivative speed control is needed in order to provide the precisely constant torque necessary for error-free measurement.

Bassett, Duane E.↗

Risk and Performance Assessment of Generic Mission Architectures: Showcasing the Artemis Mission

A has initiated a strong push to return face. In this work, we astronaut assess performance and risk for proposed mission architectures using a new Mission Architecture Risk Assessment (MARA) tool. The MARA tool can produce statistics about the availability of components and overall performance of the mission considering potential failures of any of its components. In a Monte Carlo approach, the tool repeats the mission simulation multiple times while a random generator lets modules fail according to their failure rates. The results provide statistically meaningful insights into the overall performance of the chosen architecture. A given mission architecture can be freely replicated in the tool, with the mission timeline and basic characteristics of employed mission modules (habitats, rovers, power generation units, etc.) specified in a configuration file. Crucially, failure rates for each module need to be known or estimated. The tool performs an event-driven simulation of the mission and accounts for random failure events. Failed modules can be repaired, which takes crew time but restores operations. In addition to tracking individual modules, MARA can assess the availability of predefined functions throughout the mission. For instance, the function of resource collection would require a rover to collect the resources, a power generation unit to charge the rover, and a resource processing module. Together, the modules that are required for a given function are called a functional group. Similarly, we can assess how much crew time is available to achieve a mission benefit (e.g. research, building a base, etc) as opposed to spending crew time on repairs. Here we employ the method on the proposed NASA Artemis mission. Artemis aims to return United States astronauts to the lunar surface by 2024. Results provide insights into mission failure probabilities, up- and downtime for individual modules and crew-time resources spent on the repair of failed modules. The tool also allows us to tweak the mission architecture in order to find setups that produce more favorable mission performance. As such, the tool can be an aid in improving the mission architect abling cost-benefit analysis for mission improvement.

Rumpf, Clemens M.↗

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV Charging Infrastructure Energization: An Overview of Approaches for Simplifying Processes and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure and electricity. Growth in electricity demand from EV charging, coupled with growth in other sectors like data centers and electrification of other sectors, is impacting electricity infrastructure and load service request processes after two decades of relatively flat electricity demand. While most electric vehicle charging occurs at home, enroute and depot charging for medium and heavy-duty vehicles, both using high-powered EV charging, are critical to meet electric vehicle operational needs. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have expressed distress that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions.

33 ADVANCED PROPULSION SYSTEMS↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Agrivoltaics Irradiance Database

This is a foundational data set for research and deployment of agrivoltaics, which is the co-location of agriculture and solar power plants on the same land. This irradiance and shading dataset can be utilized to determine the suitability of agrivoltaics configurations for a given region and crop-type. The data is hourly, 4x4 km resolution across the contiguous United States and Hawaii. It is calculated from the National Solar Radiation Database sites, using the System Advisor Model (SAM) to simulate the shading patterns for 10 common agrivoltaics configurations. Sunlight availability data is reported for 10 locations on the ground between adjacent rows of solar panels, as well as averaged across areas of interest such as the average irradiance in the edge-to-edge open area or across 3-6 planting beds. Other available metrics include the input meteorological data from the NSRDB (e.g. global horizontal irradiance, wind speed, etc.) and estimates for comparing energy and agricultural characteristic across the 10 configurations, including power output per acre or per kW installed capacity and farmable land area per acre.

14 SOLAR ENERGY↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗