Search NASA⌕ Search

SEARCH · Search NASA

Results for “programmatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Transuranic (Tru) waste volume reduction operations at a plutonium facility

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA 55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Size-reduction operations on glovebox equipment are a common activity when a process has been discontinued and the room is being modified to support a new customer. The Actin ide Processing Group at TA-55 uses one-meter-long glass columns to process plutonium. Disposal of used columns is a challenge, since they must be size-reduced to get them out of the glovebox. The task is a high-risk operation because the glass shards that are generated can puncture the bag-out bags, leather protectors, glovebox gloves, and the worker's skin when completing the task. One of the Lessons Learned from these operations is that Laboratory management should critically evaluate each hazard and provide more effective measures to prevent personnel injury. A bag made of puncture-resistant material was one of these enhanced controls. We have investigated the effectiveness of these bags and have found that they safely and effectively permit glass objects to be reduced to small pieces with a plastic or rubber mallet; the waste can then be easily poured into a container for removal from the glove box as non-compactable transuranic (TRU) waste. This size-reduction operation reduces solid TRU waste generation by almost 2% times. Replacing one-time-use bag-out bags with multiple-use glass crushing bags also contributes to reducing generated waste. In addition, significant costs from contamination, cleanup, and preparation of incident documentation are avoided. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the technical issues, associated with implementing this process improvement are addressed, the results discussed, effectiveness of Lessons Learned evaluated, and waste savings presented.

57↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

WE-G-BRA-04: Common Errors and Deficiencies in Radiation Oncology Practice

Purpose: Dosimetric errors in radiotherapy dose delivery lead to suboptimal treatments and outcomes. This work reviews the frequency and severity of dosimetric and programmatic errors identified by on-site audits performed by the IROC Houston QA center. Methods: IROC Houston on-site audits evaluate absolute beam calibration, relative dosimetry data compared to the treatment planning system data, and processes such as machine QA. Audits conducted from 2000-present were abstracted for recommendations, including type of recommendation and magnitude of error when applicable. Dosimetric recommendations corresponded to absolute dose errors >3% and relative dosimetry errors >2%. On-site audits of 1020 accelerators at 409 institutions were reviewed. Results: A total of 1280 recommendations were made (average 3.1/institution). The most common recommendation was for inadequate QA procedures per TG-40 and/or TG-142 (82% of institutions) with the most commonly noted deficiency being x-ray and electron off-axis constancy versus gantry angle. Dosimetrically, the most common errors in relative dosimetry were in small-field output factors (59% of institutions), wedge factors (33% of institutions), off-axis factors (21% of institutions), and photon PDD (18% of institutions). Errors in calibration were also problematic: 20% of institutions had an error in electron beam calibration, 8% had an error in photon beam calibration, and 7% had an error in brachytherapy source calibration. Almost all types of data reviewed included errors up to 7% although 20 institutions had errors in excess of 10%, and 5 had errors in excess of 20%. The frequency of electron calibration errors decreased significantly with time, but all other errors show non-significant changes. Conclusion: There are many common and often serious errors made during the establishment and maintenance of a radiotherapy program that can be identified through independent peer review. Physicists should be cautious, particularly in areas highlighted herein that show a tendency for errors.

60 APPLIED LIFE SCIENCES↗

SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing international practice standards. The approach is capable of highlighting outstanding requirements and providing recommendations to enhance both new and established programs. Timothy Solberg is co-owner of Global Radiosurgery services, LLC.

60 APPLIED LIFE SCIENCES↗

SU-F-T-262: Commissioning Varian Portal Dosimetry for EPID-Based Patient Specific QA in a Non-Aria Environment

Purpose: Development of an in-house program facilitates a workflow that allows Electronic Portal Imaging Device (EPID) patient specific quality assurance (QA) measurements to be acquired and analyzed in the Portal Dosimetry Application (Varian Medical Systems, Palo Alto, CA) using a non-Aria Record and Verify (R&V) system (MOSAIQ, Elekta, Crawley, UK) to deliver beams in standard clinical treatment mode. Methods: Initial calibration of an in-house software tool includes characterization of EPID dosimetry parameters by importing DICOM images of varying delivered MUs to determine linear mapping factors in order to convert image pixel values to Varian-defined Calibrated Units (CU). Using this information, the Portal Dose Image Prediction (PDIP) algorithm was commissioned by converting images of various field sizes to output factors using the Eclipse Scripting Application Programming Interface (ESAPI) and converting a delivered configuration fluence to absolute dose units. To verify the algorithm configuration, an integrated image was acquired, exported directly from the R&V client, automatically converted to a compatible, calibrated dosimetric image, and compared to a PDIP calculated image using Varian’s Portal Dosimetry Application. Results: For two C-Series and one TrueBeam Varian linear accelerators, gamma comparisons (global 3% / 3mm) of PDIP algorithm predicted dosimetric images and images converted via the inhouse system demonstrated agreement for ≥99% of all pixels, exceeding vendor-recommended commissioning guidelines. Conclusion: Combinations of a programmatic image conversion tool and ESAPI allow for an efficient and accurate method of patient IMRT QA incorporating a 3rd party R&V system.

60 APPLIED LIFE SCIENCES↗

SONET: a semantic ontological network graph for managing points of interest data heterogeneity

Scalability, standardization, and management are important issues when working with very large Volunteered Geographic Information (VGI). VGI is a rich and valuable source of Points of Interest (POI) information, but its inherent heterogeneity in content, structure, and scale across sources present major challenges for interlinking data sources for analysis. To be useful at scale, the raw information needs to be transformed into a standardized schema that can be easily and reliably used by data analysts. In this work, we tackle the problem of unifying POI categories (e.g. restaurants, temple, and hotel) across multiple data sources to aid in improving land use maps and population distribution estimation as well as support data analysts wishing to fuse multiple data sources with the OpenStreetMap (OSM) mapping platform or working with projects that are already configured in the OSM schema and wish to add additional sources of information. Graph theory and its implementation through the SONET graph database, provides a programmatic way to organize, store, and retrieve standardized POI categories at multiple levels of abstraction. Additionally, it addresses category heterogeneity across data sources by standardizing and managing categories in a way that makes cross-domain analysis possible.

Palumbo, Rachel↗

Secure API-Driven Research Automation to Accelerate Scientific Discovery

The Secure Scientific Service Mesh (S3M) provides API-driven infrastructure to accelerate scientific discovery through automated research workflows. By integrating near real-time streaming capabilities, intelligent workflow orchestration, and fine-grained authorization within a service mesh architecture, S3M enables secure and flexible programmatic access to high performance computing (HPC) resources. This framework allows intelligent agents and experimental facilities to dynamically provision resources and execute complex workflows, accelerating experimental lifecycles, and enabling AI-augmented autonomous science. S3M establishes a modern foundation for scientific computing infrastructure that significantly reduces traditional barriers between researchers, computational resources, and experimental facilities.

Skluzacek, Tyler [ORNL] (ORCID:0000000322424931)↗

Waste reduction process improvements in the analysis of plutonium by x-ray fluorescence: results from multiple data sets

To minimize waste, improve process safety, and minimize costs, modifications were implemented to a method for quantifying gallium in plutonium metal using wavelength dispersive X-ray fluorescence. These changes included reducing sample sizes, reducing ion exchange process volumes, using cheaper reagent grade acids, eliminating the use of HF acid, and using more robust containment film for sample analysis. Relative precision and accuracy achieved from analyzing multiple aliquots from a single parent sample were {approx}0.2% and {approx}0.1% respectively. The same precision was obtained from analyzing a total of four parent materials, and the average relative accuracy from all the samples was 0.4%, which is within programmatic uncertainty requirements.

36 MATERIALS SCIENCE↗

OpenStudio® Standards [SWR-07-40]

OpenStudio® Standards is a Ruby Gem library that extends the OpenStudio SDK. It has four main use-cases: Provide higher level methods to help BEM users and developers to create OpenStudio models from existing geometry, or programmatically generated geometry Create typical building models in OpenStudio format Create a code baseline model from a proposed model Check a model against a code/standard openstudio-standards previously supported making the DOE/PNNL prototype buildings in OpenStudio format. This has since been deprecated, as the DOE/PNNL prototypes are intended for specific code comparisons under the Energy Policy Act and are not intended to accurately represent typical existing or new buildings. While openstudio-standards still creates typical buildings, these are not the same as the DOE/PNNL prototypes.

Lopez, Phylroy↗

Parallel Lattice Subpaving Map (plsm)

Custom spatial subdivision of N-dimensional lattice region in GPU memory. An extension of the method of a hyper-octree is used to allow for arbitrary subdivision ratios in each dimension. In addition, the decision to refine (or select) a given sub-region is based on a user-provided callback, allowing for arbitrary refinement domains to be expressed either geometrically or programmatically.

Fackler, Philip↗

amerifluxr v1.0.0

An R programmatic interface for querying, handling, and summarizing AmeriFlux (https://ameriflux.lbl.gov/) data and metadata. The target users are those 1) who use data from many AmeriFlux sites, and 2) who handle data from multiple sources, e.g., AmeriFlux, PhenoCam, MODIS. The tentative features include 1) listing the sites with basic site general info, 2) querying how much data & metadata are available, 3) subsetting a target site list for download, 4) parsing data & metadata, 5) cleaning & summarizing data, 6) data visualization and 7) listing target sites' contacts & DOI.

Chu, Housen↗

Deep-Lynx-ML-Adapter

The Deep Lynx Machine Learning (ML) Adapter is a generic adapter that programmatically runs the ML as continuous data is received. Then, Jupyter Notebooks can be customized according to the project for pre-processing the data, building the machine learning models, prediction analysis of incoming data using an existing model, and forecasting anomalies / failures of the physical asset.

Wilsdon, KatherineN↗

Limbo

SAND2021-15055 O Limbo provides a programmatic interface for accessing computer vision training data. It is organized in the Limbo format. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Shead, Timothy↗

Situational Awareness of Network System Roles (SANSR)

In a large enterprise it is difficult for cyber security analysts to know what services and roles every machine on the network is performing (e.g. file server, domain name server, email server). Understanding the roles of the systems in the network provides analysts with a situational awareness that will allow them to detect consequential changes in the network, initiate an incident response plan, and optimize their security posture. Using the network flow data, already collected by most enterprises, we developed a tool that enables analysts to automatically detect/classify services and roles of every machine that’s operating on a network (e.g. file server, domain name server, email server) for better situational awareness of potential threats to the network. his tool queries Elasticsearch for network flow data, creates a temporal behavior model of each system, uses unsupervised machine learning to cluster the models with a set of labeled temporal behavior models, and the resulting information can be printed to the console or programmatically accessed. The results include the likelihood that a machine has a labeled role and lists other machines that are most similar in behavior.

Huffer, KellyM.↗

sfapi_client v1.0

This software is a client designed to interact with the Superfacility API developed at NERSC. It allows users to easily access the api in python and programmatically interact with the compute resources available at NERSC. Other implementations are ad-hoc and made by our user base, the goal of the project is to encourage more users to adopt the API by making it easier to start building complex HPC workflows.

Tyler, Nicholas↗

ProFAST (Production Financial Analysis Scenario Tool) [SWR-23-88]

The Production Financial Analysis Scenario Tool (ProFAST) provides a quick and convenient in-depth financial analysis for production facilities. The model uses a generally accepted accounting principles analysis framework and provides annual projections of income statements, cash flow statements, and balance sheets. ProFAST allows users to calculate the levelized cost of the produced commodity by providing an expected financial performance, or on the other hand, calculate the financial performance based on an input price. Model inputs generally capital expenditures, operating expenditures, and financing structure. The programmatic approach of ProFAST allows users to easily perform large sensitivity analyses and integrates easily with other python tools.

Kee, Jamie↗

Multiplayer Engineering

INL engineers developed a special purpose software framework designed to establish real-time connections between multiple running Unity instances. The framework is developed in Unity, a game engine development platform. This framework programmatically attaches functions to engineering models, enabling users to interact with, observe, and make changes to virtual models. These interactions are broadcasted through websocket connections, and received by other engineers in real-time.

Woodruff, Nathan↗

Biological Parts Search Portal (BioParts) v1.0.0

BioParts is a web based search portal for biological parts available in the public domain. It combines the ease and convenience of modern web search engines with the capabilities of bioinformatics search tools such as BLAST. This portal, available at bioparts.org, allows anyone to search for publicly accessible biological part information (e.g., NCBI, iGEM, SynBioHub, Addgene), including parts publicly accessible through ICE Registries. Additionally, the portal offers a REST API that enables third-party applications and tools to access the portal's functionality programmatically. While there are several standalone biological part repositories, there doesn't exist an application that indexes these publicly available parts and enables features such as keyword and BLAST searches along with automatic sequence annotation.

Plahar, Hector↗