Search NASASearch

SEARCH · Search NASA

Results for “recirculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

On Orbit ISS Oxygen Generation System Operation Status

The International Space Station (ISS) United States Orbital Segment (USOS) Oxygen Generation System (OGS) has accumulated almost a year of operation at varied oxygen production rates within the US Laboratory Module (LAB) since it was first activated in July 2007. It was operated intermittently through 2009 and 2010, due to filter clogging and acid accumulation in the recirculation loop. Since the installation of a deionizing bed in the recirculation loop in May of 2011 the OGA has been operated continuously. Filters in the recirculation loop have clogged and have been replaced. Hydrogen sensors have drifted apart, and a power failure may have condensed water on a hydrogen sensor. A pump delta pressure sensor failed, and a replacement new spare pump failed to start. Finally, the voltage across the cell stack increased out of tolerance due to cation contamination, and the cell stack was replaced. This paper will discuss the operating experience and characteristics of the OGS, as well as operational issues and their resolution.

Diderich, Greg S.

Fundamental Study of a Single Point Lean Direct Injector. Part I: Effect of Air Swirler Angle and Injector Tip Location on Spray Characteristics

Lean direct injection (LDI) is a combustion concept to reduce oxides of nitrogen (NOx) for next generation aircraft gas turbine engines. These newer engines have cycles that increase fuel efficiency through increased operating pressures, which increase combustor inlet temperatures. NOx formation rates increase with higher temperatures; the LDI strategy avoids high temperature by staying fuel lean and away from stoichiometric burning. Thus, LDI relies on rapid and uniform fuel/air mixing. To understand this mixing process, a series of fundamental experiments are underway in the Combustion and Dynamics Facility at NASA Glenn Research Center. This first set of experiments examines cold flow (non-combusting) mixing using air and water. Using laser diagnostics, the effects of air swirler angle and injector tip location on the spray distribution, recirculation zone, and droplet size distribution are examined. Of the three swirler angles examined, 60 deg is determined to have the most even spray distribution. The injector tip location primarily shifts the flow without changing the structure, unless the flow includes a recirculation zone. When a recirculation zone is present, minimum axial velocity decreases as the injector tip moves downstream towards the venturi exit; also the droplets become more uniform in size and angular distribution.

Tedder, Sarah A.

Investigations of Multiple Swirl-Venturi Fuel Injector Concepts: Recent Experimental Optical Measurement Results for 1-Point, 7-Point, and 9-Point Configurations

This paper presents results obtained during testing in optically-accessible, JP8-fueled, flame tube combustors using swirl-venturi lean direct injection (LDI) research hardware. The baseline LDI geometry has 9 fuel/air mixers arranged in a 3 x 3 array within a square chamber. 2-D results from this 9-element array are compared to results obtained in a cylindrical combustor using a 7-element array and a single element. In each case, the baseline element size remains the same. The effect of air swirler angle, and element arrangement on the presence of a central recirculation zone are presented. Only the highest swirl number air swirler produced a central recirculation zone for the single element swirl-venturi LDI and the 9-element LDI, but that same swirler did not produce a central recirculation zone for the 7-element LDI, possibly because of strong interactions due to element spacing within the array.

gas turbine combustion

Characterizing the Vertical Processes of Ozone in Colorado's Front Range Using the GSFC Ozone Dial

Although characterizing the interactions of ozone throughout the entire troposphere are important for health and climate processes, there is a lack of routine measurements of vertical profiles within the United States. In order to monitor this lower ozone more effectively, the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center TROPospheric OZone DIfferential Absorption Lidar (GSFC TROPOZDIAL) has been developed and validated within the Tropospheric Ozone Lidar Network (TOLNet). Two scientifically interesting ozone episodes are presented that were observed during the 2014 Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER AQ) campaign at Ft. Collins,Colorado.The first case study, occurring between 22-23 July 2014, indicates enhanced concentrations of ozone at Ft. Collins during nighttime hours, which was due to the complex recirculation of ozone within the foothills of the Rocky Mountain region. Although quantifying the ozone increase a loft during recirculation episodes has been historically difficult, results indicate that an increase of 20 -30 ppbv of ozone at the Ft. Collins site has been attributed to this recirculation. The second case, occurring between Aug 4-8th 2014, characterizes a dynamical exchange of ozone between the stratosphere and the troposphere. This case, along with seasonal model parameters from previous years, is used to estimate the stratospheric contribution to the Rocky Mountain region. Results suggest that a large amount of stratospheric air is residing in the troposphere in the summertime near Ft. Collins, CO. The results also indicate that warmer tropopauses are correlated with an increase in stratospheric air below the tropopause in the Rocky Mountain Region.

Sullivan, John T.

Laminar to Turbulence Transition in Boundary Layers due to Tripping Devices

Direct numerical simulations (DNS)and linear stability analysis were performed to identify the mechanisms by which two-and three-dimensional trips promote early transition in subsonic boundary layers over a flat plate. Investigations were conducted for two boundary layer transition trip configurations: one is a two-dimensional rectangular-shaped rod and the other is a three-dimensional zigzag tape. Reynolds numbers based on the trip heights are 683 and 300 for the two-and three-dimensional trips, respectively. Simulations with the two-dimensional trip showed that the flow separates at the top of the trip and forms a long recirculation zone downstream. However, the flow remains steady in the simulation without any external disturbances. Linear stability analysis showed that the inflectional profile in the recirculation zone is strongly unstable to frequencies in the range of 100-300 Hz. Simulations with the external disturbances forced at the frequency of 200 Hz showed that disturbances grow strongly inside the recirculation zone as observed in the Klebanoff1 experiment.

Transition

Laminar to Turbulence Transition in Boundary Layers due to Tripping Devices

Direct numerical simulations (DNS)and linear stability analyses were performed to identify the mechanisms by whichtwo-and three-dimensional trips promote early transition in subsonic boundary layers over a flat plate. Investigations were conducted for threeboundary-layer transition trip configurations:a two-dimensional smooth hump,a two-dimensional rectangular-shapedrod and a three-dimensional zig-zagtape. The smooth hump was used by Park et al.1in the linear and nonlinear parabolized stability (PSE) computations. Reynolds numbersbased on the tripheights are 710, 683,and 300 for the two-and three-dimensional trips, respectively. Simulations withthe smooth hump showed that the flow becomes stable upstream and strongly unstable downstream of the hump. Simulations with the two-dimensional rectangular trip showed that the flow separates at the top of the trip and forms a long recirculation zonedownstream. However, the flow remains steady in the simulation without any external disturbances. Linear stability analysis showed that the inflectional profile in the recirculation zone is strongly unstable to frequencies in the range of 100-300 Hz. Simulations with the external disturbances forced at the frequency of 200 Hz showed that disturbances grow strongly inside the recirculation zone as observed in the Klebanoff2 experiment. Three-dimensional simulations with secondary disturbances of fundamental, subharmonic, and oblique types produced turbulent flows shortlydownstream. The three-dimensional zig-zag trip with a small roughness Reynolds number lead to early breakdown to a turbulent flow.

Stability

Machine learning modeling and model predictive control of a closed-circuit reverse osmosis system

Closed-circuit reverse osmosis (CCRO) offers a flexible and energy-efficient alternative to conventional reverse osmosis by operating in a semi-batch mode that recycles brine, enabling higher recovery rates and reduced specific energy consumption (SEC). However, developing accurate, system-level dynamic models for CCRO remains challenging due to its nonlinear, multi-phase operation and sensitivity to variable feed water conditions. Traditional modeling approaches, such as NARMAX (nonlinear autoregressive moving average with exogenous inputs), often struggle to generalize across varying inlet feed concentrations, necessitating frequent parameter re-estimation and limiting their utility for real-time control applications. To address these limitations, we developed a long short-term memory (LSTM) neural network model trained on an extensive experimental data set from a CCRO pilot plant. The model accepts three inputs, feed flow rate, recirculation flow rate, and initial feed conductivity, and predicts three key outputs: reject conductivity, feed pump power draw, and recirculation pump power draw. We validated the LSTM model against experimental data, demonstrating its ability to distinguish between different feed conductivities and adapt to variable flow rates. Subsequently, we incorporated the LSTM model within a nonlinear model predictive control (MPC) scheme and conducted closed-loop simulations to optimize the integrated SEC (iSEC). In conclusion, the results project up to a 6% reduction in iSEC by using MPC to optimize performance over the entire experiment duration, without requiring any random excitation for data collection or parameter re-estimation.

Desalination

Large eddy simulation of lean blow-off in swirl-stabilized flame with the subgrid dissipation concept

The lean blow-off mechanism of the premixed swirl flame is numerically investigated by large eddy simulation (LES) with the subgrid dissipation concept (SDC) combustion model. Three simulated cases cover stable, near blow-off, and transient conditions. Compared with the experiment, the LES-SDC approach captures the flow and combustion features for stable and near blow-off conditions. More importantly, the predictions of the blowoff procedure and duration agree satisfactorily with the experiment, indicating that the LES-SDC approach is a promising tool for predicting strong, unsteady turbulent combustion processes. Further, the numerical results are used to investigate the blow-off mechanism. Two stages in the blow-off procedure are specified. The first is the necking and extinction of the downstream flame surface, and the second is the shrinking of the upstream flame surface. The blow-off mechanism is well explained by the theory of stretched flame extinction. At the end of the recirculation zone, the large negative radial velocity pushes the flame to the central line. The combustion process here can be abstracted as the stretched counter-flame of the reactant-reactant configuration. The excessive flame stretch dominates the flame extinction and triggers the blow-off event. The upstream flame resists the intense stretch with the help of hot product recirculation, and the combustion here can be idealized as the counter-flame of the reactant-product configuration. The alignment of the temperature gradient and flow velocity, together with the excessive stretch, clearly indicates the tendency of flame local extinction. A Damköhler number-based blow-off criterion is raised from the mean flow strain rate and laminar flame bulk extinction strain rate.

42 ENGINEERING

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Construction of 3D MHD pressure drop correlation and flow characterization in the contraction region of a fusion blanket manifold

Inlet and outlet manifolds are typical components of liquid metal (LM) blanket designs of a fusion power reactor to be used to distribute the LM flow into breeding channels and collect it at the exit of the blanket. High pressure loss in the magnetohydrodynamic (MHD) flows featuring abrupt geometrical changes is one of the main feasibility issues of such designs. Recently, optimization studies were conducted to construct 3D MHD pressure drop correlations for a LM flow in an electrically insulating manifold with gradual expansion. Here, the 3D computational approach developed in that study is applied to the outlet manifold featuring gradual contraction. A systematic analysis was performed with a total number of 135 flow cases computed with COMSOL Multiphysics for Hartmann numbers 1000 < Ha < 10,000, Reynolds numbers 100 < Re < 12,000, and contraction angles 45° < θ < 75° for a fixed contraction ratio of 4. The effects of Ha, Re and θ on the flow recirculation, development length and the total pressure drop were carefully examined. A linear regression analysis was used to determine the power rule of pressure drop coefficient k related to Ha and Re, demonstrating a good match with the Ludford layer theory. Eventually, a correlation for the 3D MHD pressure drop coefficient was constructed as a function of Ha, Re and θ. Further, the results were compared against the inlet manifold. It was found that the flow in the inlet manifold exhibits larger recirculation zones. In the investigated range of Ha, Re and θ, the pressure drop coefficient k of the LM MHD flow in the gradual contraction is only slightly lower (< 8 %) than that in the gradual expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

FFA@CEBAF beam transport error and tolerance simulation studies

The Continuous Electron Beam Accelerator Facility (CEBAF) is a 12 GeV recirculating electron accelerator at the Thomas Jefferson National Accelerator Facility (JLAB). Major upgrades to the accelerator are being investigated which include a new 650 MeV injection beamline and state-of-the-art fixed-field alternating (FFA) gradient recirculation arcs. The upgrade will extend the energy of the electron beam to over 20 GeV. In this paper, we provide an error and tolerance simulation study of the amended beam optics transport of the existing accelerator tuned for 22 GeV operation. The study is conducted with the particle tracking codes elegant and Bmad in two parts. In the first part, we treat each section of the accelerator (electromagnetic arcs and linacs) modularly with ideal conditions at the beginning. The second part is a pseudo start-to-end (S2E) simulation with accumulated errors propagating from one beamline to the next.

Accelerator Physics

Current status of conceptual horizontal splitter design for FFA@CEBAF energy Upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations of the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. In order to control the beam parameters through these FFA arcs, horizontal splitters must be used. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics

Status of 22 GeV CEBAF Upgrade Using FFA Arcs

Jefferson Lab is exploring an upgrade to extend CEBAF’s energy to ~22 GeV within the existing tunnel by incorporating Fixed-Field Alternating-Gradient (FFA) arcs. In this scheme, the two lowest-energy electromagnetic arcs are removed, the remaining arcs are reassigned to lower energies, and a new pair of high-energy FFA arcs enables six additional recirculations using the existing SRF linacs. The non-scaling FFA lattice employs Halbach-derived permanent magnets with provisions for dipole, quadrupole, and higher-order components, offering large momentum acceptance and reduced operating cost. Implementing this concept requires updated linac optics, modifications to the remaining arcs, and a redesigned electromagnetic switchyard. Ongoing beam-dynamics studies address synchrotron-radiation–induced energy loss and emittance growth, along with strategies for their mitigation.

Ogur, S. [Thomas Jefferson National Accelerator Fa

Status of conceptual horizontal splitter design for FFA@CEBAF energy upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. Horizontal splitters are needed to control the beam parameters through these FFA arcs. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics

Status of permanent magnet radiation resiliency studies at CEBAF

An ongoing investigation for the future of Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) lies in upgrading its maximum nominal energy using Fixed-Field Alternating-gradient (FFA) technology for its recirculating arcs, using permanent magnets for the FFA arcs. A common concern among the community is the degradation of these permanent magnets during operation due to the radiation environment in which they will be present. This work, funded by a Laboratory Directed R&D grant, aims to measure the permanent magnet degradation in the CEBAF tunnel enclosure, and extrapolate to the energies expected from the upgrade. We present the latest results of this study, as well as plans moving forward.

Accelerator Physics

‘Universal Injector’ at LERF - Layout and Optics Architecture

Here, we present a next level design of a compact injector within the LERF vault, which would serve both the 22 GeV CEBAF and the positron program, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three C-75 cryo-modules, five isochronous return arcs and three straight sections, facilitating electron beam acceleration up to 650 MeV. The Universal Injector offers flexibility of extraction 1-pass and 2-pass energy electrons, as needed for positron production, with a final 3-pass extraction required by the 650 MeV injector for 22 GeV CEBAF. This note provides an overview of the baseline optics design of the Universal Injector complex, including the 8 MeV injector merger and the recirculator racetrack, including individual extraction lines for all three passes. A comprehensive suite of beam dynamics studies to validate the design is under way; starting with the orbit correction scheme, followed by start-to-end tracking with lattice misalignments and magnet errors.

Bogacz, Alex [Thomas Jefferson National Accelerato

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion

Advanced deep sea diving equipment

Design requirements are generated for a deep sea heavy duty diving system to equip salvage divers with equipment and tools that permit work of the same quality and in times approaching that done on the surface. The system consists of a helmet, a recirculator for removing carbon dioxide, and the diver's dress. The diver controls the inlet flow by the recirculatory control valve and is able to change closed cycle operation to open cycle if malfunction occurs. Proper function of the scrubber in the recirculator minimizes temperature and humidity effects as it filters the returning air.

Danesi, W. A.