Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Experimental review of the performances of protective coatings for interconnects in solid oxide fuel cells

Ferritic stainless-steel interconnects are used in solid oxide fuel cells; however, coatings are required to improve their performance. Although several types of coatings have been proposed, they have been scarcely investigated under similar conditions. This study compares the characteristics of uncoated Crofer 22 APU and eight different coatings on Crofer 22 APU for up to 3,000 hours at 800°C. The coatings were deposited at various research laboratories around the world, and the experiments were performed at Chalmers University of Technology, Sweden. Cross-sections of the samples were analysed using scanning electron microscopy and energy-dispersive x-ray spectroscopy. The (Co,Mn)-based coated steels showed more than 50-fold lower chromium evaporation and at least 3 times thinner Cr 2 O 3 scale thickness compared to uncoated steel. The coated steel samples showed lower area-specific resistance (ASR) values than the uncoated steel after 3,000 hours of exposure, irrespective of the coating thickness, composition and deposition method.

25 ENERGY STORAGE↗

Quantifying Pore Morphology in Spray-Formed Tantalum Using X-ray Micro-computed Tomography

In order to establish quantitative process–structure–property relationships in thermal spray coatings, a robust framework for defining (micro)structural characteristics is needed. Here, we present a quantitative characterization of the three-dimensional morphology of porosity in spray-formed tantalum samples based on high-resolution X-ray micro-computed tomography. Using synchrotron facilities, we acquired dozens of high-resolution scans, enabling a statistically meaningful comparison across multiple samples, different regions within samples, and spray processes. We quantify the spatial distribution, size, and topology of porous inclusions, with a significant focus on variability across samples and different spray processes (plasma and cold sprayed), as well as sensitivity to image segmentation and resolution. Based on a typical segmentation, we report porosities ranging from 0.9 to 1.7 pct for all samples tested, with significant sensitivity due to image segmentation resulting in estimates as low as 0.6 pct and as high as 4.8 pct. For the complex pore space morphology observed in these materials, we argue that a conventional analysis based on identifying individual pores is not well suited, and propose an alternative approach based on morphological metrics with a rich history in porous media literature, such as spatial correlations, local pore thickness, and scale-dependent sub-sampling. Spatial correlations indicate anisotropic splat structures, but only mildly anisotropic pores. Various measures of pore size show a wide distribution of sizes, ranging from sub-micron to 10-micron length scales. Scale-dependent variations in porosity suggest that representative volumes of several hundred microns are required for convergence of morphological metrics, with larger volumes for cold-spray materials. This work provides a robust quantitative basis for describing three-dimensional pore structure in thermal spray coatings.

36 MATERIALS SCIENCE↗

Hydrothermal corrosion of 2nd generation FeCrAl alloys for accident tolerant fuel cladding

As part of an effort to develop advanced fuel cladding for use in light water reactors, several FeCrAl alloys have been developed at Oak Ridge National Laboratory. A second generation of these alloys bearing additional alloying elements over the previously tested model alloys were tested in boiling water reactor (BWR) conditions to determine their resistance to hydrothermal corrosion. Coupons with alloy compositions Fe–10Cr–6Al–2Mo, Fe–13Cr–5Al–2Mo, Fe–13Cr–6Al–2Mo, Fe–13Cr–7Al–2Mo, and Fe–13Cr–5Al–2Mo–1Nb were tested in normal water chemistry (NWC) and hydrogen water chemistry (HWC) for 9 months in continuously refreshing autoclaves. Commercial FeCrAl alloy APMT and Zircaloy-2 were also tested for comparison. Among samples exposed to HWC, Fe–13Cr–7Al–2Mo performed worst with an average mass loss of 1.3 mg/cm2 over 9 months. This mass loss represents an estimated thickness loss of approximately 60 μm over 6 years. Samples exposed to NWC had very small mass losses of less than 0.15 mg/cm2 or mass gains up to 0.05 mg/cm2. Based on the results of this testing, the 2nd generation FeCrAl alloys tested exhibit low wall thickness loss and are suitable in terms of corrosion resistance for use as LWR cladding in BWR-HWC and BWR-NWC under normal operating conditions.

Raiman, Stephen↗

Carbon Fiber Reinforced Plastic with Substantially Improved Through-plane Thermal Conductivity

Thermal conductivity of carbon fiber support structures that also serve as cooling substrates is of increasing importance for high energy physics detectors. One of the shortcomings of current carbon fiber laminates is that they exhibit excellent thermal conductivity of order several hundred W/(m*K) along the fiber direction, whereas the through plane thermal conductivity perpendicular to the fibers is orders of magnitude lower, and at about 1 W/(m*K) more in the range of thermal insulators. This proposal aims to significantly improve the through plane thermal conductivity, by at least a factor five, changing CFRP from being a thermal insulator to a thermal conductor in the through plane direction. Between June 2021 and December 2022, a total of 36 carbon fiber laminate test samples and two carbon loaded epoxy test samples were manufactured and analyzed for thermal performance. Unfortunately, the promising results obtained with a similar sample manufactured in 2017 were not reproduced. We believe this to be mainly due the excessive age of the carbon fiber prepreg material used for this SBIR - the same material batch, produced in 2015, was used in 2017 and in 2021/2022, i.e. the material was seven years old when the final samples were produced - , and to a lesser degree to the difference in pressure attainable with the 2017 and 2021/2022 laminate curing setups. While disappointing, the results are not completely discouraging, since for the samples with the highest compression the through-plane thermal conductivities plotted as a function of per-ply thickness extrapolate well to the data point from the 2017 sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Film Thickness and Composition Effects in Symmetric Ternary Block Copolymer/Homopolymer Blend Films: Domain Spacing and Orientation

We report thickness and homopolymer molar mass dependencies in thin film blends of a compositionally symmetric 75 kg/mol lamellar polystyrene-block-poly(methyl methacrylate) diblock copolymer (PS-b-PMMA) with near-equal volume fractions of PS and PMMA homopolymers on “neutral” surfaces that promote a vertical domain orientation. PS and PMMA homopolymers with equal molar masses of 1, 3, and 22 kg/mol are blended in a 1:1 mass ratio. To efficiently explore this parameter space, we prepared combinatorial samples with gradient homopolymer concentrations using electrospray deposition (ESD) and gradient film thicknesses using flow coating; these samples were subsequently characterized by grazing-incidence small-angle X-ray scattering and scanning electron microscopy, respectively. Our results demonstrate that the added homopolymers increase or reduce domain spacings with respect to the neat (unblended) block copolymer depending on their molar masses, in line with previous reports; a simple heuristic to estimate the domain scaling in ternary blends based on the homopolymer molar mass agrees well with data for the thinnest blend films studied here. More surprisingly, we observe that the measured domain spacing in blends also depends on film thickness, with thicker films exhibiting larger domain spacings than thinner films at the same homopolymer concentration. Furthermore, thickness gradients at fixed homopolymer concentrations reveal a change in lamellae orientation from vertical to horizontal as film thickness is increased beyond the nominal lamellar domain spacing. Coarse-grained molecular dynamics simulations indicate that this change in orientation is induced by homopolymer segregation to film surfaces. Finally, tying these effects together, we hypothesize that the observed dependence of domain spacing on film thickness is a consequence of changes in the vertical homopolymer composition profile in thicker films during lamellae reorientation and the conformational asymmetry between PMMA and PS segments.

36 MATERIALS SCIENCE↗

Using synthetic infrared spectra derived from n/k optical constants for standoff detection of chemical deposits

We report results from a recent field experiment to test the validity of using physics-based synthetic infrared spectra to serve as endmembers in a spectral database targeted at chemical deposits. Specifically, the optical constants n and k, (the real and imaginary part of the refractive index) were used to first model infrared reflectance spectra for different thicknesses of chemical layers (e.g. acetaminophen, methylphosphonic acid – MPA, etc.) on various conducting and insulating substrates such as aluminum, wood, and glass. In the experimental portion of the research, thin films of the solid and liquid analytes were deposited onto such substrates to form micron-thick layers of the analytes at different thicknesses: Standoff data from an imaging instrument were then recorded and analyzed to not only identify the different analytes, but also quantify the layer/deposit thickness. To gauge success, the detection results using the synthetic data were compared to the results from hemispherical reflectance (HRF) spectra that were collected for the same sample planchets measured in the field via standoff methods. Preliminary results indicate good agreement between the synthetic reference data as compared to the lab-measured HRF data in terms of their ability to quantitatively reduce longwave infrared data. Specifically, modeled IR spectra for acetaminophen on an aluminum planchet at various thicknesses (1, 2, 5, 10, 15, and 20 µm) were synthesized and compared with standoff field reflectance data as well as HRF laboratory reflectance spectra for two samples: a 5.2 µm- and 12.8 µm-thick layer of acetaminophen on aluminum. Using a first-order approximation, analysis of the field data estimates the thicknesses of the samples to be 2 and 10 µm for the two samples, respectively, while the HRF laboratory data yields thickness estimates of between 5-10 µm and 10 µm, respectively. Both yield reasonable estimates, with the uncertainty most likely due to factors yet to be accounted for in the synthetic spectra such as light scattering.

complex index of refraction, optical constants, hy↗

The rapid-tome, a 3D-printed microtome, and an updated hand-sectioning method for high-quality plant sectioning

Abstract Background Microscopic analysis of plant anatomy is a common procedure in biology to study structure and function that requires high-quality sections for accurate measurements. Hand sectioning of specimens is typically limited to moderately soft tissue while harder samples prohibit sectioning by hand and/or result in inconsistent thicknesses. Results Here we present both a clearly described hand-sectioning method and a novel microtome design that together provide the means to section a variety of plant sample types. The described hand-sectioning method for herbaceous stems works well for softer subjects but is less suitable for samples with secondary growth (e.g., wood production). Instead, the “Rapid-Tome” is a novel tool for sectioning both soft and tougher high-aspect-ratio samples, such as stems and roots, with excellent sample control. The Rapid-Tome can be 3D-printed in approximately 18 h on a mid-quality printer common at university maker spaces. After printing and trimming, Rapid-Tome assembly takes a few minutes with five metal parts common at hardware stores. Users sectioned a variety of plant samples including the hollow internodes of switchgrass ( Panicum virgatum ), fibrous switchgrass roots containing aerenchyma, and woody branches of eastern red cedar ( Juniperus virginiana ) and American sycamore ( Platanus occidentalis ). A comparative analyses with Rapid-Tome-produced sections readily revealed a significant difference in seasonal growth of sycamore xylem vessel area in spring (49%) vs. summer (23%). Additionally, high school students with no prior experience produced sections with the Rapid-Tome adequate for comparative analyses of various plant samples in less than an hour. Conclusions The described hand-sectioning method is suitable for softer tissues, including hollow-stemmed grasses and similar samples. In addition, the Rapid-Tome provides capacity to safely produce high-quality sections of tougher plant materials at a fraction of the cost of traditional microtomes combined with excellent sample control. The Rapid-Tome features rapid sectioning, sample advancement, blade changes, and sample changes; it is highly portable and can be used easily with minimal training making production of thin sections accessible for classroom and outreach use, in addition to research.

3D-printing↗

High-temperature thermal conductivity measurements of macro-porous graphite

Graphite is a unique material for high temperature applications and will likely become increasingly important as we attempt to electrify industrial applications. Here, we investigate the thermal properties of low-quality, macro-porous graphite to determine the tradeoff between quality and thermal performance. We use laser flash analysis (LFA) to measure the thermal diffusivity of graphite at high temperatures. Due to the large pores in the graphite samples preventing uniform laser flash heating, we first apply a thick coating to achieve the required flat, parallel surfaces for LFA measurements. We then develop a methodology to extract properties of the sample from the diffusivity measurements, based on finite element modeling of a variety of sample/coating interface profiles. Validating the methodology against a reference sample demonstrates a mean absolute percentage error of 8.5%, with potential improvement with better sample characterization. We show low-quality graphite has a thermal conductivity of ~10 W/m/K up to 1000 °C, which is an order of magnitude lower than high-quality graphite, but contributions from photon conductivity may result in higher conductivities at higher temperatures. Overall, we demonstrate an approach for measuring thermal properties of macro-porous materials at high temperatures, and apply the approach to measuring thermal conductivity of porous graphite, which will aid in the design of hightemperature systems for cost-competitive decarbonization.

Verma, Shomik↗

Magnetic structure of Fe 16 N 2 determined by polarized neutron diffraction on thin-film samples

Strain-free Fe 16 N 2 thin films were obtained on MgO (001) single-crystal substrates with Cr seed layers. Additionally, x-ray diffraction and transmission electron microscopy confirmed that the film is textured in all three spatial directions with crystallographic orientation determined by epitaxial constraints from the substrate. Average grain size was estimated to be in the range of tens of nanometers. Ten pieces of 40-nm-thick Fe 16 N 2 thin-film samples were stacked together for half-polarized neutron diffraction study at room temperature. A total of six reflections were usable, from which the magnetic structure of Fe 16 N 2 was determined and compared to existing models. Contrary to most electronic structure calculations, the present results suggest that the magnetic moment of Fe atoms at the 8h site is large and larger than that of the 4d site. Our results support the giant magnetization of Fe 16 N 2 .

36 MATERIALS SCIENCE↗

Study of the perpendicular magnetic anisotropy, spin–orbit torque, and Dzyaloshinskii–Moriya interaction in the heavy metal/CoFeB bilayers with Ir 22 Mn 78 insertion

The perpendicular magnetic anisotropy (PMA), current-induced spin–orbit torques (SOTs), and Dzyaloshinskii–Moriya interaction (DMI) in the as-grown W or Ta/Ir 22 Mn 78 (IrMn)/CoFeB/MgO stacks with varying IrMn layer thicknesses were investigated. The in-plane magnetized W/CoFeB/MgO sample becomes perpendicularly magnetized after inserting the IrMn layer without the requirement of the annealing process. The effective magnetization fields 4π Meff show a nonmonotonic dependence on the IrMn layer thickness, which reaches the maximum in magnitude at a thickness of tIrMn = 0.75 nm. The SOT effective fields corresponding to damping-like and field-like torques decrease with the insertion layer thickness. Moreover, the variation of the IrMn layer thickness leads to the change of the DMI in magnitude and sign change from positive (favoring right-handed chirality) to negative (favoring left-handed chirality). The realization of changing the PMA, SOTs, and DMI by inserting the IrMn layer provides more flexibility in the design of spintronic devices.

Physics↗

Improved Understanding of Zircaloy Hydrogen Pickup Mechanisms in BWRs. NSUF Report (Final Report)

Using an instrumented autoclave operating at 288°C and 1100 psi, electrical impedance spectroscopy (EIS) measurements were taken from three neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). The three high priority fuel channel samples were tested at 288°C using a simulated PWR water with the AC frequency range extending down through 10 -4 Hz, with corresponding DC measurements to validate the resistance measurements. EIS measurements were also taken at room temperature using a simulated PWR water from four neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). and four water rod samples (Zircaloy-2). EIS measurements were also performed on unirradiated Zircaloy-2 tubes that were previously oxidized in autoclaves at various temperatures for different time durations to obtain oxide layers of different thicknesses. These experiments proved to be more challenging than anticipated because of the small size of the samples, which required development of fixtures to allow valid testing of the materials, some of which are radioactive, under pressure and temperature. Equivalent circuits were used to model the data. Some samples resulted in Nyquist plots where the arcs were too close to each other resulting in the inability to separate the different oxide morphological thicknesses. Microstructural characterization in the form of optical microscopy, scanning electron microscopy and (scanning) transmission electron microscopy was performed to document the microstructural features of the oxidized Zr-2 and Zr-4 samples (oxide and metal/oxide interface) and to interpret the EIS results. At the start of this work, it was assumed that despite the laminar cracks and porosity visible in both optical and SEM, the oxide scale is dense near the metal, effectively preventing the water from contacting the metal directly. While it is generally accepted that the large laminar cracks pores allow the water to percolate into the oxide film, it is unknown just how deep it can go, and how interconnected is the porosity, which will dictate how much the porosity is connected electrically to the water within the oxide scale. The EIS results demonstrated that there is in fact a distribution of oxide thicknesses over the various samples, and within each material condition, that are communicating to the liquid. This is derived from the fact that Nyquist plots have an arc radius whose center point is often below the Z’ axis, implying that instead of a single oxide thickness, these oxides have a distribution of thicknesses. This distribution of thicknesses produces arcs that are not clearly separable in most of the samples.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Metal-organic chemical vapor deposition of MgGeN2 films on GaN and sapphire

MgGeN2 films were synthesized using metal-organic chemical vapor deposition on GaN/c-sapphire templates and c-plane sapphire substrates. Energy-dispersive x-ray spectroscopy was used to estimate the cation composition ratios. To mitigate magnesium evaporation, the films were grown at pyrometer temperature 745 °C with a wafer rotation speed of 1000 rpm. Growth rates were determined by fitting energy-dispersive x-ray spectroscopy spectra to film thicknesses using NIST DTSA-II software. The thickness estimates determined by this method were consistent with scanning transmission electron microscopy measurements done for selected samples. Scanning electron microscopy images revealed faceted surfaces indicative of a tendency toward three-dimensional growth. X-ray diffraction spectra confirmed that the films were highly crystalline and exhibited preferential orientation in alignment with the substrate. Atomic force microscopy measurements show that film thicknesses are consistent across samples grown on both GaN templates and sapphire substrates, with typical roughnesses around 10 nm. Transmittance spectra of films grown on double-side-polished sapphire substrates yielded band gaps of 4.28 ± 0.06 eV for samples exhibiting close-to-ideal stoichiometry. Comparison of the measured spectra with ab initio calculations are in good agreement both near the bandgap and at higher energies where excitation is into higher-lying bands. These findings provide insight into the growth and characterization of MgGeN2, contributing to the development of this material for potential applications in optoelectronics and power electronics.

Hu, Chenxi (ORCID:0000000236299660)↗

Secondary-electron imaging of bulk crystalline specimens in an aberration corrected $\text{STEM}$

Atomic-scale electron microscopy traditionally probes thin specimens, with thickness below 100 nm, and its feasibility for bulk samples has not been documented. Here in this study, we explore the practicality of scanning transmission electron microscope (STEM) imaging with secondary electrons (SE), using a silicon-wedge specimen having a maximum thickness of 18 μm. We find that the atomic structure is present in the entire thickness range of the SE images although the background intensity increases moderately with thickness. The consistent intensity of secondary electron (SE) images at atomic positions and the modest increase in intensity in between (background) observed in silicon suggest a limited contribution from SEs generated by backscattered electrons, a conclusion supported by our multislice calculations. We conclude that achieving atomic resolution in SE imaging for bulk specimens is indeed attainable using aberration-corrected STEM and that an aberration-corrected scanning electron microscope (SEM) may have the capacity for atomic-level resolution, holding great promise for future strides in materials research.

25 ENERGY STORAGE↗

Influence of electronic transport on electrochemical performance of (Cu,Mn) 3 O 4 solid oxide fuel cell cathodes

Alkaline Earth free spinel oxides provide a potential benefit over Sr-doped perovskite-based materials commonly used as electrodes in high-temperature electrochemical energy conversion devices, e.g., solid oxide fuel cells (SOFCs). Sr-segregation is a known issue leading to performance degradation. In this study, Cu x Mn 3-x O 4 (x = 1, 1.2, and 1.5) porous electrodes were examined as SOFC cathodes using electrochemical impedance spectroscopy to investigate the oxygen reduction reaction (ORR) kinetics in relation to the material's intrinsic conductivity, the extrinsic electrode structure, and the cell test design. Similar to the electronic conducting (La,Sr)MnO 3 SOFC cathodes, the ORR kinetics of Cu x Mn 3-x O 4 spinel electrodes was governed by the oxygen adsorption and diffusion at the particle surface as well as the charge transfer at the triple phase boundaries. The overall electrode polarization resistance was highly dependent on contact density with the metallic current collector, active material particle connectivity, electrode thickness, and the intrinsic electronic materials conductivity. Here, we describe the importance of effective electronic charge transport parallel to the electrode surface in maximizing the electrochemically active electrode volume and enhancing electrode performance. We discuss an approach to optimize cell and electrode design with respect to active materials properties. This aspect is critical to ensure reliable evaluation of new materials, since laboratory-scale button-cells typically exhibit a high degree of electrode microstructure (e.g. porosity, thickness) and electrical contact density variation from sample to sample.

(Cu,Mn)3O4↗

Demonstration of non-destructive and isotope-sensitive material analysis using a short-pulsed laser-driven epi-thermal neutron source

Neutrons are a valuable tool for non-destructive material investigation as their interaction cross sections with matter are isotope sensitive and can be used complementary to x-rays. So far, most neutron applications have been limited to large-scale facilities such as nuclear research reactors, spallation sources, and accelerator-driven neutron sources. Here we show the design and optimization of a laser-driven neutron source in the epi-thermal and thermal energy range, which is used for non-invasive material analysis. Neutron resonance spectroscopy, neutron radiography, and neutron resonance imaging with moderated neutrons are demonstrated for investigating samples in terms of isotope composition and thickness. The experimental results encourage applications in non-destructive and isotope-sensitive material analysis and pave the way for compact laser-driven neutron sources with high application potential.

36 MATERIALS SCIENCE↗

X-ray linear dichroic tomography of crystallographic and topological defects

Abstract The functionality of materials is determined by their composition 1–4 and microstructure, that is, the distribution and orientation of crystalline grains, grain boundaries and the defects within them 5,6 . Until now, characterization techniques that map the distribution of grains, their orientation and the presence of defects have been limited to surface investigations, to spatial resolutions of a few hundred nanometres or to systems of thickness around 100 nm, thus requiring destructive sample preparation for measurements and preventing the study of system-representative volumes or the investigation of materials under operational conditions 7–15 . Here we present X-ray linear dichroic orientation tomography (XL-DOT), a quantitative, non-invasive technique that allows for an intragranular and intergranular characterization of extended polycrystalline and non-crystalline 16 materials in three dimensions. We present the detailed characterization of a polycrystalline sample of vanadium pentoxide (V 2 O 5 ), a key catalyst in the production of sulfuric acid 17 . We determine the nanoscale composition, microstructure and crystal orientation throughout the polycrystalline sample with 73 nm spatial resolution. We identify and characterize grains, as well as twist, tilt and twin grain boundaries. We further observe the creation and annihilation of topological defects promoted by the presence of volume crystallographic defects. The non-destructive and spectroscopic nature of our method opens the door to operando combined chemical and microstructural investigations 11,18 of functional materials, including energy, mechanical and quantum materials.

Science & Technology - Other Topics↗

Thermomechanical response of thickly tamped targets and diamond anvil cells under pulsed hard x-ray irradiation

In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here, we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th-generation synchrotron facilities. Intense hard x-ray beams can deliver significant energy in targets having thick x-ray transparent layers (tampers) around samples of interest for the study of novel states of matter and materials’ dynamics. Heated-state lifetimes in such targets can approach the microsecond level, regardless of radiation pulse duration, enabling the exploration of conditions of local thermal and thermodynamic equilibrium at extreme temperature in solid density matter. The thermal and mechanical responses of such thick layered targets following x-ray heating, including hydrodynamic relaxation and heat flow on picosecond to millisecond timescales, are modeled using radiation hydrocode simulation, finite element analysis, and thermodynamic calculations. Assessing the potential for target survival over one or more exposures and resistance to damage arising from heating and resulting mechanical stresses, this study doubles as an investigation into the performance of diamond anvil high pressure cells under high x-ray fluences. Long used in conjunction with synchrotron x-ray radiation and high power optical lasers, the strong confinement afforded by such cells suggests novel applications at emerging high intensity x-ray facilities and new routes to studying thermodynamic equilibrium states of warm, very dense matter.