The Effects of Different Lattice Codes on Results of Sensitivity and Uncertainty Analysis
According to the UAM ('Uncertainty Analysis in Modeling') benchmark, uncertainties in the LWR system calculations at all stages should be determined and quantified. As the neutronics calculations are prerequisite for the predictions of the reactor system, and the uncertainties introduced by the neutronics calculations would be propagated to the subsequent calculations, hence uncertainty analysis has been firstly focused on the neutronics phase to quantify the uncertainties of the reactor-physics predictions in UAM. For the lattice physics, the objective of uncertainty analysis is focused on uncertainty quantifications of the few-group constants; for the core physics, uncertainties of the core steady-state stand-alone neutronics calculations are focused on. Based on the previous researches, the nuclear-data uncertainty has been treated as one of the most significant source of uncertainty and received the most focus. In the previous works, the domestic code UNICORN has the capability of performing sensitivity analysis and uncertainty analysis using the direct numerical perturbation (DNP) method and statistical sampling (SS) method. In this paper, the capability of the UNICORN code has been improved. The domestic lattice code NECP-CACTI has been added in UNICORN to perform the lattice calculations, with DRAGON5.0 and NECP-CACTI available for lattice calculations. For DRAGON5.0 and NECP-CACTI, all the methods and technologies are shared in UNICORN. Therefore, the effects of different lattice codes on the results of sensitivity and uncertainty analysis have been researched and determined in this paper. (authors)