Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An optical-input Maximum Likelihood Estimation feedback system demonstrated on tokamak horizontal equilibrium control

A readily parallelized Maximum Likelihood Estimation (MLE) algorithm with linear computational complexity is demonstrated in real time using only measurements from an extreme ultraviolet (EUV) diagnostic to control the horizontal position of a tokamak plasma. A set of trial emissivity profiles are parameterized by the control quantity of interest (R m ), and the MLE is identified from the profile which minimizes the signal reconstruction residual. The algorithm depends on an empirically determined likelihood function with exponential form. EUV emission (λ ≈ 15eV-1keV) is captured in a poloidal plane by four 16-channel AXUV diodes mounted at different poloidal angles with radial and angular resolution sufficient to discern plasma equilibrium evolution in HBT-EP. Calculations of the plasma major radius by the system are consistent within diagnostic uncertainty for the majority of the discharge with those of: a weighted average of vertical soft X-ray or EUV chords, magnetic sensors, and an equilibrium reconstruction. The feedback system corrects for a horizontal displacement of the major radius equal to 20% of the plasma minor radius by adjusting the vertical field produced from 40 in-vessel control coils in real time. The MLE calculation is performed on a GPU in a 15 μs cycle, with similar performance in this application to a simple weighted average of vertical chords. Finally, results demonstrate horizontal position control using magnetic actuators and an optical observer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional topological magnetic monopoles and their interactions in a ferromagnetic meta-lattice

Topological magnetic monopoles (TMMs), also known as hedgehogs or Bloch points, are three-dimensional (3D) nonlocal spin textures that are robust to thermal and quantum fluctuations due to the topology protection. Although TMMs have been observed in skyrmion lattices, spinor Bose–Einstein condensates, chiral magnets, vortex rings and vortex cores, it has been difficult to directly measure the 3D magnetization vector field of TMMs and probe their interactions at the nanoscale. Here, we report the creation of 138 stable TMMs at the specific sites of a ferromagnetic meta-lattice at room temperature. We further develop soft x-ray vector ptycho-tomography to determine the magnetization vector and emergent magnetic field of the TMMs with a 3D spatial resolution of 10 nm. This spatial resolution is comparable to the magnetic exchange length of transition metals, enabling us to probe monopole-monopole interactions. We find that the TMM and anti-TMM pairs are separated by 18.3±1.6 nm, while the TMM and TMM, anti-TMM and anti-TMM pairs are stabilized at comparatively longer distances of 36.1±2.4 nm and 43.1±2.0 nm, respectively. We also observe virtual TMMs created by magnetic voids in the meta-lattice. This work demonstrates that ferromagnetic meta lattices could be used as a platform to create and investigate the interactions and dynamics of TMMs. Furthermore, we expect that soft x-ray vector ptycho-tomography can be broadly applied to quantitatively image 3D vector fields in magnetic and anisotropic materials at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗

Hard Ferromagnetism Down to the Thinnest Limit of Iron-Intercalated Tantalum Disulfide

Two-dimensional (2D) magnetic crystals hold promise for miniaturized and ultralow power electronic devices that exploit spin manipulation. In these materials, large, controllable magnetocrystalline anisotropy (MCA) is a prerequisite for the stabilization and manipulation of long-range magnetic order. In known 2D magnetic crystals, relatively weak MCA typically results in soft ferromagnetism. Furthermore, we demonstrate that ferromagnetic order persists down to the thinnest limit of Fe x TaS 2 (Fe-intercalated bilayer 2H-TaS 2 ) with giant coercivities up to 3 T. We prepare Fe-intercalated TaS 2 by chemical intercalation of van der Waals-layered 2H-TaS 2 crystals and perform variable-temperature transport, transmission electron microscopy, and confocal Raman spectroscopy measurements to shed new light on the coupled effects of dimensionality, degree of intercalation, and intercalant order/disorder on the hard ferromagnetic behavior of Fe x TaS 2 . More generally, we show that chemical intercalation gives access to a rich synthetic parameter space for low-dimensional magnets, in which magnetic properties can be tailored by the choice of the host material and intercalant identity/amount, in addition to the manifold distinctive degrees of freedom available in atomically thin, van der Waals crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental demonstration of enhanced self-amplified spontaneous emission by photocathode temporal shaping and self-compression in a magnetic wiggler

In this paper we demonstrate experimentally the generation of attosecond soft X-ray free-electron laser (XFEL) pulses based on a novel approach to enhanced self-amplfied spontaneous emission. Instead of utilizing an external laser, we shape the electron beam at the cathode by laser pulse stacking. We enhance the high-current spike in the beam profile through a self-compression process which uses short-range coherent synchrotron radiation in a wiggler and a downstream magnetic chicane. The undulator taper is then matched with the energy chirp along the beam for attosecond XFEL generation. Start-to-end simulations are performed to demonstrate the proposed method. The measured spectra suggest that a ~250 as pulse duration is achieved at ~940 eV in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Creation and observation of Hopfions in magnetic multilayer systems

Among topological solitons, magnetic skyrmions are two-dimensional particle-like objects with a continuous winding of the magnetization, and magnetic Hopfions are three-dimensional objects that can be formed from a closed loop of twisted skyrmion strings. Theoretical models suggest that magnetic Hopfions can be stabilized in frustrated or chiral magnetic systems, and target skymions can be transformed into Hopfions by adapting their perpendicular magnetic anisotropy, but their experimental verification has been elusive so far. Here, we present an experimental study of magnetic Hopfions that are created in Ir/Co/Pt multilayers shaped into nanoscale disks, known to host target skyrmions. To characterize three-dimensional spin textures that distinguish Hopfions from target skyrmions magnetic images are recorded with surface-sensitive X-ray photoemission electron microscopy and bulk-sensitive soft X-ray transmission microscopy using element-specific X-ray magnetic circular dichroism effects as magnetic contrast. These results could stimulate further investigations of Hopfions and their potential application in three-dimensional spintronics devices.

36 MATERIALS SCIENCE↗

Effect of the space weather conditions on the Earth magnetosphere soft X-ray emissivity

The aim of the study is to model and characterize the soft X-ray emissivity on the Earth magnetosphere for different space weather conditions (SWC), providing information to interpret the soft X-ray measurements of the Solar wind Magnetosphere Ionosphere Link Explorer space mission. The MHD code pluto in spherical coordinates is used to perform parametric studies with respect to the solar wind (SW) dynamic pressure (considering density and velocity effects independently) as well as the IMF intensity and orientation, predicting the soft X-ray emissivity for different SWC. The integrated soft X-ray emissivity inside the magnetosheath is calculated as a proxy of the soft X-ray emission dependencies with the SWC independently of the satellite orbit and camera line of sight. The analysis indicates fluctuations of the interplanetary magnetic field (IMF) orientation and magnitude may significantly affect the measured soft X-ray emission although changes in the SW dynamic pressure should be the main source of variability. The southward IMF orientation leads to the configuration with the largest soft X-ray emissivity and northward to the lowest. Strongly distorted magnetospheres explored in configurations showing SW and IMF parameters comparable to the impact of interplanetary coronal mass ejections may show a decrease of the soft X-ray emissivity as the IMF magnitude increases, explained by the strong magnetosphere compression and constriction of the magnetosheath region where the soft X-ray emissivity maximum is located. The simulations also indicate large excursions of the soft X-ray emissivity maximum inside the magnetosheath as the IMF magnitude and SW dynamic pressure fluctuate particularly for radial and ecliptic IMF orientations.

Earth↗

A magnetic sensor using a 2D van der Waals ferromagnetic material

Two-dimensional (2D) van der Waals ferromagnetic materials are emerging as promising candidates for applications in ultra-compact spintronic nanodevices, nanosensors, and information storage. Our recent discovery of the strong room temperature ferromagnetism in single layers of VSe2 grown on graphite or MoS2 substrate has opened new opportunities to explore these ultrathin magnets for such applications. In this paper, we present a new type of magnetic sensor that utilizes the single layer VSe2 film as a highly sensitive magnetic core. The sensor relies in changes in resonance frequency of the LC circuit composed of a soft ferromagnetic microwire coil that contains the ferromagnetic VSe2 film subject to applied DC magnetic fields. We define sensitivity as the slope of the characteristic curve of our sensor, df0/dH, where f0 is the resonance frequency and H is the external magnetic field. The sensitivity of the sensor reaches a large value of 16×106Hz/Oe, making it a potential candidate for a wide range of magnetic sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of photoinduced normal state through charge density wave in superconducting YBa 2 Cu 3 O 6.67

The normal state of high-T c cuprates has been considered one of the essential topics in high-temperature superconductivity research. However, compared to the high magnetic field study of it, understanding a photoinduced normal state remains elusive. Here, we explore a photoinduced normal state of YBa 2 Cu 3 O 6.67 through a charge density wave (CDW) with time-resolved resonant soft x-ray scattering, as well as a high magnetic field x-ray scattering. In the nonequilibrium state where people predict a quenched superconducting state based on the previous optical spectroscopies, we experimentally observed a similar analogy to the competition between superconductivity and CDW shown in the equilibrium state. We further observe that the broken pairing states in the superconducting CuO 2 plane via the optical pump lead to nucleation of three-dimensional CDW precursor correlation. Ultimately, these findings provide a critical clue that the characteristics of the photoinduced normal state show a solid resemblance to those under magnetic fields in equilibrium conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital Light Process 3D Printing of Magnetically Aligned Liquid Crystalline Elastomer Free–forms

Liquid crystalline elastomers (LCEs) are anisotropic soft materials capable of large dimensional changes when subjected to a stimulus. The magnitude and directionality of the stimuli-induced thermomechanical response is associated with the alignment of the LCE. Recent reports detail the preparation of LCEs by additive manufacturing (AM) techniques, predominately using direct ink write printing. Another AM technique, digital light process (DLP) 3D printing, has generated significant interest as it affords LCE free-forms with high fidelity and resolution. However, one challenge of printing LCEs using vat polymerization methods such as DLP is enforcing alignment. Here, we document the preparation of aligned, main-chain LCEs via DLP 3D printing using a 100 mT magnetic field. Systematic examination isolates the contribution of magnetic field strength, alignment time, and build layer thickness on the degree of orientation in 3D printed LCEs. Informed by this fundamental understanding, DLP is used to print complex LCE free-forms with through-thickness variation in both spatial orientations. Further, the hierarchical variation in spatial orientation within LCE free-forms is used to produce objects that exhibit mechanical instabilities upon heating. DLP printing of aligned LCEs opens new opportunities to fabricate stimuli-responsive materials in form factors optimized for functional use in soft robotics and energy absorption.

36 MATERIALS SCIENCE↗

Impact of the chiral asymmetry and a magnetic field on the passage of an energetic test parton in a QCD medium

We study the dependence of soft contribution to the energy loss of a test parton moving with a high velocity on the chiral imbalance and magnetic field in the QCD medium. A semiclassical approach is adopted to estimate the parton energy loss that takes into account the back-reaction on the parton due to the polarization effects of the QCD medium while traversing through the medium. We find that the motion of the parton is sensitive to the chiral asymmetry in the medium. Further, we investigate the effect of magnetic field-induced anisotropy on the energy transfer between the moving parton and the medium. Our results show that the energy loss of the parton is strongly influenced by the strength of the magnetic field as well as the relative orientation of the motion of the parton and the direction of the magnetic field in the medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future of condensed matter physics for the next 10 years

This perspective outlines a selection of research directions that members of the JPCM editorial board anticipate may shape the frontier of condensed matter physics over the next decade. Rather than a comprehensive review or formal roadmap, this perspective reflects a set of informed views drawn from diverse areas of expertise. Our intention is to spark curiosity, provoke discussion, and encourage readers to imagine—and pursue—the exciting possibilities that lie ahead.

chemical physics↗

Colloquium: Ice rule and emergent frustration in particle ice and beyond

Geometric frustration and the ice rule are two concepts that are intimately connected and widespread across condensed matter. The first refers to the inability of a system to satisfy competing interactions in the presence of spatial constraints. The second, in its more general sense, represents a prescription for the minimization of the topological charges in a constrained system. Both can lead to manifolds of high susceptibility and nontrivial, constrained disorder where exotic behaviors can appear and even be designed deliberately. This Colloquium describes the emergence of geometric frustration and the ice rule in soft condensed matter. It excludes the extensive developments of mathematical physics within the field of geometric frustration, but rather focuses on systems of confined microscopic or mesoscopic particles that emerge as a novel paradigm exhibiting spin degrees of freedom. In such systems, geometric frustration can be engineered artificially by controlling the spatial topology and geometry of the lattice, the position of the individual particle units, or their relative filling fraction. These capabilities enable the creation of novel and exotic phases of matter and also potentially lead toward technological applications related to memory and logic devices that are based on the motion of topological defects. The rapid progress in theory and experiments is reviewed and the intimate physical connections with other frustrated systems at different length scales are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing sample degradation from synchrotron based X-ray measurements of ultra-thin exfoliated flakes

It is undeniable that novel 2D devices and heterostructures will have a lasting impact on the advancement of future technologies. However, the inherent instability of many exfoliated van der Waals (vdW) materials is a well-known hurdle yet to be overcome. Thus, the sustained interest in exfoliated vdW materials underscores the importance of understanding the mechanisms of sample degradation to establish proactive protective measures. Here, the impact of prolonged synchrotron-based X-ray beam exposure on exfoliated flakes of two contemporary vdW materials, NiPS 3 and α-RuCl 3 , is explored using resonant inelastic X-ray scattering (RIXS) and total fluorescence yield X-ray absorption spectroscopy (XAS). In NiPS 3 , the resulting RIXS and XAS spectra show a suppression, then vanishing, of NiS 6 multiplet excitations coupled with an upward shift of the peak energy of the XAS as a function of X-ray dose. In α-RuCl 3 , the signs of beam damage from the RIXS spectra are less evident. However, the post-experiment characterization of both materials using Raman spectroscopy exhibits signals of an amorphous and disordered system compared to pristine flakes; in addition, energy-dispersive X-ray spectroscopy of NiPS 3 shows evidence of ligand vacancies. As synchrotron radiation is fast becoming a required probe to study 2D vdW materials, these findings lay the groundwork for the development of future protective measures for synchrotron-based prolonged X-ray beam exposure, as well as for X-ray free electron laser.

2D magnetism↗

Pair Cascades in Magnetar Magnetospheres

Resonant inverse Compton scattering (RICS) of soft thermal photons by relativistic particles on closed magnetic field loops has been proposed to explain the hard emission observed up to and beyond 200 keV from magnetars. If particles injected at the base of the loops have Lorentz factors ≳10 2 , the RICS spectra will be attenuated by both one-photon pair production and photon splitting in the ultrastrong magnetar fields, producing additional spectral components from pair synchrotron radiation and split photons that produce further generations of pairs and split photons. We investigate such cascades initiated by the primary injected electrons through a Monte Carlo simulation, and study the cascade spectra and pair distributions. For most observer angles, the pair synchrotron and split-photon spectra dominate the RICS primary spectra and produce complex polarization signals. In particular, the synchrotron spectra are highly polarized with degree 40%–80%, are softer than the RICS spectra, and may account for the high polarization of some magnetar spectra observed by the Imaging X-ray Polarimetry Explorer above 3 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal↗

Single‐Domain Multiferroic Array‐Addressable Terfenol‐D (SMArT) Micromagnets for Programmable Single‐Cell Capture and Release

Abstract Programming magnetic fields with microscale control can enable automation at the scale of single cells ≈10 µm. Most magnetic materials provide a consistent magnetic field over time but the direction or field strength at the microscale is not easily modulated. However, magnetostrictive materials, when coupled with ferroelectric material (i.e., strain‐mediated multiferroics), can undergo magnetization reorientation due to voltage‐induced strain, promising refined control of magnetization at the micrometer‐scale. This work demonstrates the largest single‐domain microstructures (20 µm) of Terfenol‐D (Tb 0.3 Dy 0.7 Fe 1.92 ), a material that has the highest magnetostrictive strain of any known soft magnetoelastic material. These Terfenol‐D microstructures enable controlled localization of magnetic beads with sub‐micrometer precision. Magnetically labeled cells are captured by the field gradients generated from the single‐domain microstructures without an external magnetic field. The magnetic state on these microstructures is switched through voltage‐induced strain, as a result of the strain‐mediated converse magnetoelectric effect, to release individual cells using a multiferroic approach. These electronically addressable micromagnets pave the way for parallelized multiferroics‐based single‐cell sorting under digital control for biotechnology applications.

Khojah, Reem↗