Synchronous High-frequency Distributed Readout For Edge Processing At The Fermilab Main Injector And Recycler

The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more systematic study of the machine and improved displays of routine operation. However, current projects are demanding more data and at a faster rate from this aging hardware. One such project, Real-time Edge AI for Distributed Systems (READS), requires the high-frequency, low-latency collection of synchronized BLM readings from around the approximately two-mile accelerator complex. Significant work has been done to develop new hardware to monitor the VME backplane and broadcast BLM measurements over Ethernet, while not disrupting the existing operations critical functions of the BLM system. This paper will detail the design, implementation, and testing of this parallel data pathway.

43 PARTICLE ACCELERATORS↗

Multiple Grid-Forming Inverters in Black-Start: The Challenges

Black-start is a major challenge toward the successful operation of an islanded inverter-based system. In this article, the technical challenges for the black-start of multiple grid-forming inverters are reported. Specifically, this article discusses inverter synchronization, voltage and frequency regulation, and power-sharing between the grid-forming inverters. Experiment results from a multi-inverter test-bed have been provided to support the discussion. Furthermore, a grid-forming inverter controller for black-start operation is developed and presented in this article that addresses the discussed technical challenges. The performance of the developed controller in black-start operation is verified through experiment results.

Sadeque, Fahmid↗

Mooring Load Monitoring of a Wave Energy Converter Using a Self-Synchronizing Underwater Acoustic Network

A self-synchronizing underwater acoustic network, designed for remote monitoring of mooring loads in Wave Energy Converters (WEC), has been developed and tested. This network uses Time Division Multiple Access and operates self-contained with the ability for users to remotely transmit commands to the network as needed. Each node is a self-contained unit, consisting of a protocol adaptor board, an underwater acoustic modem and a battery pack. A node can be connected to a load cell, to a topside user or to the WEC. Every node is swapable. The protocol adaptor board, named Protocol Adaptor for Digital LOad Cell (PADLOC) supports a variety of digital load cell message formats (CAN, MODBUS, custom ASCII) and underwater acoustic modem serial formats. PADLOC enables topside users to connect to separate load cells through a user-specific command.

acoustic↗

Type 5 Wind Turbine Technology: How Synchronised, Synchronous Generation Avoids Uncertainties About Inverter Interoperability under IEEE 2800:2022

Degradation of system strength because of inverter-based resources (IBRs) is a major concern facing the zero-carbon transition. A new standard released this year, IEEE Standard 2800, attempts to codify the relationship between IBRs and the Transmission System Operator (TSO). It is apparent from IEEE 2800:2022 that there remain fundamental problems with quantifying whether source impedance (the measure of "system strength" with which the standard is concerned) will present a problem for allowing an IBR to connect. This is "because of complex interdependencies between IBR and power system characteristics". So developers are increasingly required to adopt mitigation options such as adding synchronous condensers or curtailing IBRs. A proven Type 5 (synchronous) wind turbine exists and has been running at 0.5 MW scale in a 46 MW wind farm in New Zealand since 2006 and eight turbines in Scotland since 2013. The US National Renewable Energy Laboratory (NREL) is conducting a study of the impacts on grid reliability, stability, and resilience of Type 5 wind turbines. The project has both simulation and testing tasks and will result in proposing a variable generation solution that will help system operators and utilities address all reliability and most resilience challenges in the evolving grid.

grid stability↗

A signal packet router for the upgrade of the Muon spectrometer at the ATLAS experiment

Here, we present the design, characterization, and production of a signal packet router for the upgrade of the ATLAS forward muon detector. The router serves as a packet switch in one of the primary trigger paths. It handles up to 12 serial inputs at 4.8 Gbps/input from on-detector electronics and outputs four 4.8 Gbps to the trigger processing circuits. In the 12-to-4 packet switching process, the input streams are decoded and synchronized to a common clock domain for data packets forwarding and NULL packets suppression. Challenges in the design include operations of multi-giga hertz serial links with low and constant latency (<100 ns) for packet routing, as well as mitigation of radiation-induced effects in the harsh radiation environment over 10 years of detector operation. The Router design has been fully characterized and demonstrated to meet all specifications. In total 256 Routers were installed in the detector. Its design concept can be used in other similar applications, particularly in a radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION↗

A Simulation Study of Quantum Clock Synchronization Using Teleportation

An important requirement in implementing distributed computing and sensing application is the synchronization of clocks at various locations. The Internet relies on the Network Time Protocol (NTP), which synchronizes clocks with accuracy in the order of milliseconds. More recently an ensemble of atomic clocks is used for navigation based on GPS. These clocks are highly accurate and provide time with very low uncertainty. Even so, many physics experiments such as distributed LIGO-based systems may require more accurate clock synchronization that is achievable using quantum entanglement. This requires the deployment of a network of quantum clocks synchronized by exploiting entangled atomic clock qubits. In this paper, we carry out a simulation study of synchronizing a network of quantum clocks interconnected by a fiber plant that supports the ESnet; the latter is used to support the classical communication needed for teleportation. We consider an existing protocol for synchro-nizing the atomic clock qubits that relies on the GHZ states. To assess the performance of the protocol we developed a discrete-event simulation of the network using IBM Qiskit framework for underlying quantum gate operations and measurements. The simulation results shed light on the resources required in terms of the number entangled qubits and the time needed to achieve the synchronization of different number of nodes in ESnet.

Kiran, Mariam↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation: Preprint

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators' rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

61 RADIATION PROTECTION AND DOSIMETRY↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators’ rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Phase Drifts and Signal Dispersion in Coaxial Cables

Phase reference distribution is a critical challenge in modern linear particle accelerators, such as European Spallation Source (ESS), European X-ray Free Electron Laser (E-XFEL), or Proton Improvement Plan II (PIP-II). Similar issues may also arise in other RF systems that need to synchronize many independent circuits. Achieving low phase drift of the reference signal requires careful selection of cables and their environmental operating conditions. Due to the limited data provided by cable manufacturers, it is necessary to characterize the cable performance. This article investigates the phase drifts in coaxial cables and presents a dedicated measurement methodology. The dispersion characteristics of the cables are also examined. The measurement results of various coaxial cables are presented, along with conclusions and practical guidelines for designers of phase reference distribution lines.

coaxial cables↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Power and Energy Storage Systems Toolbox -- PSTess v.1.0

The Power and Energy Storage Systems Toolbox (PSTess) is a MATLAB-based computing package for dynamic simulation and analysis of utility-scale battery storage systems. This codebase is a fork of the Power Systems Toolbox Version 3.0, developed at Rensselaer Polytechnic Institute (RPI) and Cherry Tree Scientific Software. While PSTess shares a common lineage with PST, it is a substantially different application. As the name implies, the main distinguishing characteristic of PSTess is its ability to model inverter-based energy storage systems (ESS). The model that enables this is called ess.m, and it serves the dual role of representing ESS operational constraints and the generator/converter interface. With PSTess, the generator/converter interface is modeled as a controllable current source with the ability to modulate both active and reactive current. The model ess.m permits four-quadrant modulation, which allows it to represent a wide variety of inverter-based resources beyond energy storage when paired with an appropriate supplemental control model. Examples include utility-scale photovoltaic (PV) power plants, type 4 wind plants, and static synchronous compensators (STATCOM). This capability is especially useful for modeling hybrid plants that combine energy storage with renewable resources. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-8322 O

Elliott, RyanT.↗

City and Borough of Sitka, Alaska: Modeling and Controls Assistance and Renewable Energy Resource Assessment [Slides]

This project develops the dynamic modeling of hydro plants and wind generation in Sitka, Alaska. A dynamic penetration of renewables was evaluated under various conditions. The impact of altering hydro generation control to synchronous condenser control was evaluated. While the existing hydro generations are sufficient to address voltage instability, a detailed study of the active-reactive capability limits of hydro generation operation should be conducted to uptake at various wind penetration levels.

14 SOLAR ENERGY↗

Two-level overlapping additive Schwarz preconditioner for training scientific machine learning applications

In this work we introduce a novel two-level overlapping additive Schwarz preconditioner for accelerating the training of scientific machine learning applications. The design of the proposed preconditioner is motivated by the nonlinear two-level overlapping additive Schwarz preconditioner. The neural network parameters are decomposed into groups (subdomains) with overlapping regions. In addition, the network’s feed-forward structure is indirectly imposed through a novel subdomain-wise synchronization strategy and a coarse-level training step. Through a series of numerical experiments, which consider physicsinformed neural networks and operator learning approaches, we demonstrate that the proposed two-level preconditioner significantly speeds up the convergence of the standard (LBFGS) optimizer while also yielding more accurate machine learning models. Moreover, the devised preconditioner is designed to take advantage of model-parallel computations, which can further reduce the training time.

97 MATHEMATICS AND COMPUTING↗

Specifying angular reference for robust three-phase state estimation

While the phase angle of any of the bus voltages can be chosen as the angular reference in the state estimation formulation of positive sequence networks, the same approach does not readily extend to three-phase network state estimation problem. It is commonly assumed that there is at least one bus where the bus voltages are perfectly balanced with phase angles displaced ±120° and these balanced three phase voltages are used as the three-phase reference in solving the three-phase state estimation problem. This assumption may be quite realistic in transmission networks, and for distribution networks with a strong transmission system connection. However, it might not be realistic to assume existence of a perfectly balanced reference bus in today’s distribution systems with ever increasing penetration of renewable sources or for isolated operation of microgrids. In this paper, a novel state estimation formulation will be presented which facilitates correct solution irrespective of the existence of buses with perfectly balanced voltages. The new formulation is general, and lends itself to bad data processing. It yields accurate results in any three-phase power system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. The performance of the method is validated using the IEEE 123 bus three-phase system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.