Search NASA⌕ Search

SEARCH · Search NASA

Results for “table detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synchronization trigger control system for flow visualization

The use of cinematography or holographic interferometry for dynamic flow visualization in an internal combustion engine requires a control device that globally synchronizes camera and light source timing at a predefined shaft encoder angle. The device is capable of 0.35 deg resolution for rotational speeds of up to 73 240 rpm. This was achieved by implementing the shaft encoder signal addressed look-up table (LUT) and appropriate latches. The developed digital signal processing technique achieves 25 nsec of high speed triggering angle detection by using direct parallel bit comparison of the shaft encoder digital code with a simulated angle reference code, instead of using angle value comparison which involves more complicated computation steps. In order to establish synchronization to an AC reference signal whose magnitude is variant with the rotating speed, a dynamic peak followup synchronization technique has been devised. This method scrutinizes the reference signal and provides the right timing within 40 nsec. Two application examples are described.

Chun, K. S.↗

Spatio-Temporal Deep Graph Network for Event Detection, Localization, and Classification in Cyber-Physical Electric Distribution System

This work proposes a deep graph learning framework to identify, locate, and classify power, cyber, and cyber power events at the distribution system level. The proposed algorithm jointly exploits spatial, temporal, and node-level cyber and physical data features. The developed graph neural network, together with a deep autoencoder, utilizes physical measurements from distribution level phasor measurement units and cyber data from communication network logs. The spatial structure of the synchrophasor measurements and network is incorporated through a weighted adjacency matrix. The temporal structure is incorporated by defining a spatial operation in the gated recurrent unit. This spatio-temporal learning element resides inside a power event detection, localization, and classification module that provides the degree of confidence for an event label. To accurately pinpoint the location of an event to the nearest bus equipped with a measurement unit, a combination of squared error and proximity score is utilized. Also included is a cyber event detection module that employs heteroskedasticity to analyze the significance of various cyber features during different types of attacks. Finally, a dual-bit cyber-power decision table determines the nature of the event. The proposed method is validated on two distribution systems modeled in OPAL-RT/Hypersim with limited phasor measurement units for different possible physical and cyber events. Further analyses include comparison with other state-of-the-art methods and validation in the presence of measurement noise. As a result, our method outperforms existing approaches and achieves an average detection accuracy of 97.97%, F1-score of 96.88%, precision of 96.53%, and recall of 98.57%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

XCMS Online: A Web-Based Platform to Process Untargeted Metabolomic Data

Recently, interest in untargeted metabolomics has become prevalent in the general scientific community among an increasing number of investigators. The majority of these investigators, however, do not have the bioinformatic expertise that has been required to process metabolomic data by using command-line driven software programs. Here we introduce a novel platform to process untargeted metabolomic data that uses an intuitive graphical interface and does not require installation or technical expertise. This platform, called XCMS Online, is a web-based version of the widely used XCMS software that allows users to easily upload and process liquid chromatography/mass spectrometry data with only a few mouse clicks. XCMS Online provides a solution for the complete untargeted metabolomic workflow including feature detection, retention time correction, alignment, annotation, statistical analysis, and data visualization. Results can be browsed online in an interactive, customizable table showing statistics, chromatograms, and putative METLIN identities for each metabolite. Additionally, all results and images can be downloaded as zip files for offline analysis and publication. XCMS Online is available at https://xcmsonline.scripps.edu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arecibo emission-absorption observations of Galactic OH

Observations of OH emission/absorption toward 19 low-Galactic-latitude background-continuum sources are reported. Data obtained at 1.665 and 1.667 GHz using the 12-m radio telescope at Arecibo Observatory during February-March 1984, are presented in extensive tables and graphs and characterized in detail, with reference to theoretical models. A total of 11 OH absorption features were detected toward nine of the sources, with an average of one feature of optical depth 0.02 or greater per 5 kpc of path length and an average column density of 1.6 x 10 to the 12th/sq cm (corrected to b = 90 deg).

Colgan, Sean W. J.↗

MULTI-OMICS ANALYSIS OF THE IMPACT OF CHRONIC LOW-DOSE RADIATION AND HINDLIMB SUSPENSION ON MURINE BRAIN AND RETINA

The space environment includes hazards like radiation and microgravity which can adversely affect biological systems. We assessed multi-omics multi-tissue NASA GeneLab datasets where 6-month-old female mice were gamma irradiated (IR) and/or hindlimb unloaded (HLU) for 21 days. Whole transcriptome shotgun sequencing (RNA-Seq) and reduced representation bisulfite sequencing (RRBS) of brain and retina samples collected at 4 months post-exposure was performed to better characterize the retinal and neurological responses to spaceflight. We compared epigenomic and transcriptomic profiles within each exposure group for both tissue types to identify correlation (Pearson’s correlation test; p-value < 0.05) between gene expression and DNA methylation levels that may be related to transcriptional regulation. We then obtained genes with methylation-expression correlation that also showed differences in mean expression or dispersion between exposed and control groups (adjusted p-value < 0.25; relaxed to denote ‘hypothesis’) in the brain (37 genes in HLU, 4 in IR, and 156 in HLU+IR) or retina (92 genes in HLU, 1 in IR, and 55 in HLU+IR). Enriched Gene Ontology (GO) terms for these genes are listed in Table 1 for HLU and HLU+IR for both tissue types. No enriched terms and only a few genes were detected with IR-only exposure in the brain (Chmp1a, Limd1, Rab40b, Ubc) and retina (retinoblastoma binding protein Rbbp7). Cellular components related to synapse were enriched in both tissue types. Previous analysis of differentially expressed genes in the retina after 1 month of HLU+IR showed enrichment in the somatodendritic compartment of the neuron, which was also observed in the brain 4 months post-exposure. Interestingly, genes related to ubiquitination showed correlation between methylation and expression and were differentially expressed or dispersed in different exposure groups indicating that this pathway may play an important role in multi-stressor response (Figure 1). The current multi-omics and multi-tissue analysis interrogates the epigenomic and transcriptomic impacts of radiation and hindlimb unloading, in isolation and in combination, on the retina and the brain. The results provide insight into the adaptive response to individual spaceflight hazard analogs and their interplay, as well as hypotheses to be further tested for understanding spaceflight-induced neurological and vision effects.

Prachi Kothiyal↗

REDUCTION AND SEQUESTRATION OF PERTECHNETATE TO TECHNETIUM DIOXIDE AND PROTECTION FROM RE-OXIDATION

This effort is part of the technetium management initiative and provides data for the handling and disposition of technetium. To that end, the objective of this effort was to challenge tin(II)apatite (Sn(II)apatite) against double-shell tank 241-AN-I0S simulant spiked with pertechnetate (TcO{sub 4}{sup -}). The Sn(II)apatite used in this effort was synthesized on site using a recipe developed at and provided by Sandia National Laboratories; the synthesis provides a high quality product while requiring minimal laboratory effort. The Sn(II)apatite reduces pertechnetate from the mobile +7 oxidation state to the non-mobile +4 oxidation state. It also sequesters the technetium and does not allow for re-oxidization to the mobile +7 state under acidic or oxygenated conditions within the tested period of time (6 weeks). Previous work indicated that the Sn(II)apatite can achieve an ANSI leachability index in Cast Stone of 12.8. The technetium distribution coefficient for Sn(II)apatite exhibits a direct correlation with the pH of the contaminated media. Table 1 shows Sn(II)apatite distribution coefficients as a function of pH. The asterisked numbers indicate that the lower detection limit of the analytical instrument was used to calculate the distribution coefficient as the concentration of technetium left in solution was less than the detection limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Target Detection Using Fractal Geometry

The concepts and theory of fractal geometry were applied to the problem of segmenting a 256 x 256 pixel image so that manmade objects could be extracted from natural backgrounds. The two most important measurements necessary to extract these manmade objects were fractal dimension and lacunarity. Provision was made to pass the manmade portion to a lookup table for subsequent identification. A computer program was written to construct cloud backgrounds of fractal dimensions which were allowed to vary between 2.2 and 2.8. Images of three model space targets were combined with these backgrounds to provide a data set for testing the validity of the approach. Once the data set was constructed, computer programs were written to extract estimates of the fractal dimension and lacunarity on 4 x 4 pixel subsets of the image. It was shown that for clouds of fractal dimension 2.7 or less, appropriate thresholding on fractal dimension and lacunarity yielded a 64 x 64 edge-detected image with all or most of the cloud background removed. These images were enhanced by an erosion and dilation to provide the final image passed to the lookup table. While the ultimate goal was to pass the final image to a neural network for identification, this work shows the applicability of fractal geometry to the problems of image segmentation, edge detection and separating a target of interest from a natural background.

Fuller, J. Joseph↗

Degradation-related defect level in weathered silicon heterojunction modules characterized by deep level transient spectroscopy

Commercial silicon heterojunction photovoltaic modules, known as amorphous-silicon-based heterojunction with intrinsic thin-film layer (HIT) modules, show average degradation after 10 years in the field. HIT modules weathered outdoors in Colorado and Florida display mostly uniform decreases in intensity when mapped with photoluminescence (PL) imaging compared to a control module. Flash-table-based current-voltage curves show that degradation is dominated by voltage loss. Samples are cored from each of the modules, and deep level transient spectroscopy (DLTS) detects three electron-trap defect states in all modules with activation energies of electron emission from the defects of 0.07, 0.16, and 0.50 eV. DLTS measurements on the weathered modules show an additional deep-level, electron-trap defect state with an activation energy of 0.51 eV and a trap density of approximately 10 12 cm –3 . The capture rate is measured using varying short filling pulse times, and the resulting capture cross section is estimated to be 1.1x10 –16 cm 2 . The development of the weathering-related defect level correlates to decreases in carrier lifetime, PL intensity, and module voltage. Various depths of the space charge region are probed with increments in applied reverse bias and filling-pulse bias. Furthermore, this DLTS depth profiling shows a trend of trap density increasing with less applied reverse bias, suggesting that the weathering-related defect increases carrier recombination toward the interface between the bulk silicon wafer and the junction-forming amorphous-silicon passivation layers.

14 SOLAR ENERGY↗

AN EXTENDED AND MORE SENSITIVE SEARCH FOR PERIODICITIES IN ROSSI X-RAY TIMING EXPLORER/ALL-SKY MONITOR X-RAY LIGHT CURVES

We present the results of a systematic search in {approx}14 years of Rossi X-ray Timing Explorer All-Sky Monitor (ASM) data for evidence of periodicities. Two variations of the commonly used Fourier analysis search method have been employed to significantly improve upon the sensitivity achieved by Wen et al. in 2006, who also searched for periodicities in ASM data. In addition, the present search is comprehensive in terms of sources studied and frequency range covered, and has yielded the detection of the signatures of the orbital periods of eight low-mass X-ray binary systems and of ten high-mass X-ray binaries not listed in the tables of Wen et al. Orbital periods, epochs, signal amplitudes, modulation fractions, and folded light curves are given for each of these systems. Seven of the orbital periods are the most precise reported to date. In the course of this work, the 18.545 day orbital period of IGR J18483-0311 was co-discovered, and the first detections in X-rays were made of the {approx}3.9 day orbital period of LMC X-1 and the {approx}3.79 hr orbital period of 4U 1636-536. The results inform future searches for orbital and other periodicities in X-ray binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Laser-Induced Breakdown Spectroscopy Sensor Technology for Rapid Source Characterization of Rare Earth Elements

A prototype Laser Induced Breakdown Spectroscopy (LIBS) sensor is tested for the determination of rare earth elements (Eu and Yb) in liquid and solid samples. The sensor head, built using a monolithic passively Q-switched (PQSW) Nd:YAG laser, produced a 1064 nm laser beam with 3.3 ns pulses and an energy of 4.2 mJ. The measurements show good calibration linearity for both Eu and Yb with R 2 values above 0.99 for all analyzed spectral lines in liquid and solid samples. Limits of Detection (LODs) obtained were as low as 1 ppm, which are comparable to or better than those reported previously by using table top actively Q-switched systems. This study aims to develop a high sensitivity, field deployable sensor for characterizing existing and new sources of rare earth elements

47 OTHER INSTRUMENTATION↗

Patterns of Error in Confidential Maintenance Incident Reports

Confidential reports of maintenance incidents are a valuable source of information on maintenance errors and the contexts within which they occur. NASA's Aviation Safety Reporting System (ASRS) has been receiving an increasing number of maintenance incident reports since a specialized maintenance reporting form was introduced in 1996. In a series of studies, the database of ASRS maintenance incidents was examined using correspondence analysis, a statistical technique that converts complex data tables into a visual form. The analyses revealed patterns within the ASRS data set that would have otherwise been difficult to detect. The results have implications for a range of purposes including human factors training, the design of procedures, and the identification of improvements in aircraft design.

Hobbs, Alan↗

A 3D MR-acquisition scheme for nonrigid bulk motion correction in simultaneous PET-MR

Purpose: Positron emission tomography (PET) is a highly sensitive medical imaging technique commonly used to detect and assess tumor lesions. Magnetic resonance imaging (MRI) provides high resolution anatomical images with different contrasts and a range of additional information important for cancer diagnosis. Recently, simultaneous PET-MR systems have been released with the promise to provide complementary information from both modalities in a single examination. Due to long scan times, subject nonrigid bulk motion, i.e., changes of the patient's position on the scanner table leading to nonrigid changes of the patient's anatomy, during data acquisition can negatively impair image quality and tracer uptake quantification. A 3D MR-acquisition scheme is proposed to detect and correct for nonrigid bulk motion in simultaneously acquired PET-MR data. Methods: A respiratory navigated three dimensional (3D) MR-acquisition with Radial Phase Encoding (RPE) is used to obtain T1- and T2-weighted data with an isotropic resolution of 1.5 mm. Healthy volunteers are asked to move the abdomen two to three times during data acquisition resulting in overall 19 movements at arbitrary time points. The acquisition scheme is used to retrospectively reconstruct dynamic 3D MR images with different temporal resolutions. Nonrigid bulk motion is detected and corrected in this image data. A simultaneous PET acquisition is simulated and the effect of motion correction is assessed on image quality and standardized uptake values (SUV) for lesions with different diameters. Results: Six respiratory gated 3D data sets with T1- and T2-weighted contrast have been obtained in healthy volunteers. All bulk motion shifts have successfully been detected and motion fields describing the transformation between the different motion states could be obtained with an accuracy of 1.71 ± 0.29 mm. The PET simulation showed errors of up to 67% in measured SUV due to bulk motion which could be reduced to less than 10% with the proposed motion compensation approach. Conclusions: A MR acquisition scheme which yields both high resolution 3D anatomical data and highly accurate nonrigid motion information without an increase in scan time is presented. The proposed method leads to a strong improvement in both MR and PET image quality and ensures an accurate assessment of tracer uptake.

60 APPLIED LIFE SCIENCES↗

Improvement in detection of small wildfires

Detecting and imaging small wildfires with an Airborne Scanner is done against generally high background levels. The Airborne Scanner System used is a two-channel thermal IR scanner, with one channel selected for imaging the terrain and the other channel sensitive to hotter targets. If a relationship can be determined between the two channels that quantifies the background signal for hotter targets, then an algorithm can be determined that removes the background signal in that channel leaving only the fire signal. The relationship can be determined anywhere between various points in the signal processing of the radiometric data from the radiometric input to the quantized output of the system. As long as only linear operations are performed on the signal, the relationship will only depend on the system gain and offsets within the range of interest. The algorithm can be implemented either by using a look-up table or performing the calculation in the system computer. The current presentation will describe the algorithm, its derivation, and its implementation in the Firefly Wildfire Detection System by means of an off-the-shelf commercial scanner. Improvement over the previous algorithm used and the margin gained for improving the imaging of the terrain will be demonstrated.

Sleigh, William J.↗

Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

Kelbaugh, B. N.↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37-19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37- 19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extremely red objects in the fields of high redshift radio galaxies

We are engaged in a program of infrared imaging photometry of high redshift radio galaxies. The observations are being done using NICMOS2 and NICMOS3 arrays on the DuPont 100-inch telescope at Las Campanas Observatory. In addition, Persson and Matthews are measuring the spectral energy distributions of normal cluster galaxies in the redshift range 0 to 1. These measurements are being done with a 58 x 62 InSb array on the Palomar 5-m telescope. During the course of these observations we have imaged roughly 20 square arcminutes of sky to limiting magnitudes greater than 20 in the J, H, and K passbands (3 sigma in 3 square arcseconds). We have detected several relatively bright, extremely red, extended objects during the course of this work. Because the radio galaxy program requires Thuan-Gunn gri photometry, we are able to construct rough photometric energy distributions for many of the objects. A sample of the galaxy magnitudes within 4 arcseconds diameter is given. All the detections are real; either the objects show up at several wavelengths, or in subsets of the data. The reddest object in the table, 9ab'B' was found in a field of galaxies in a rich cluster at z = 0.4; 9ab'A' lies 8 arcseconds from it.

Persson, S. E.↗