Search NASASearch

SEARCH · Search NASA

Results for “Mechanics of Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,292 records · Page 113

Synthetic battery cycling techniques

Synthetic battery cycling makes use of the fast growing capability of computer graphics to illustrate some of the basic characteristics of operation of individual electrodes within an operating electrochemical cell. It can also simulate the operation of an entire string of cells that are used as the energy storage subsystem of a power system. The group of techniques that as a class have been referred to as Synthetic Battery Cycling is developed in part to try to bridge the gap of understanding that exists between single cell characteristics and battery system behavior.

Leibecki, H. F.

Battery system and method for sensing and balancing the charge state of battery cells

A battery system utilizes a plurality of transformers interconnected with the battery cells. The transformers each have at least one transformer core operable for magnetization in at least a first magnetic state with a magnetic flux in a first direction and a second magnetic state with a magnetic flux in a second direction. The transformer cores retain the first magnetic state and the second magnetic state without current flow through said plurality of transformers. Circuitry is utilized for switching a selected transformer core between the first and second magnetic states to sense voltage and/or balance particular cells or particular banks of cells.

Davies, Francis J.

Assembly bias and local Primordial non-Gaussianity from DESI DR1 quasars

The analysis of the large-scale clustering of quasars (QSO) observed by the Dark Energy Spectroscopic Instrument (DESI) represents a promising avenue for constraining local Primordial non-Gaussianity (PNG), parameterized by f NL . The signal to be constrained is the scale-dependent bias induced in the 2-point clustering of the considered tracer sample. The resulting constraints on f NL , however, are fully degenerate with the local PNG bias parameter b ϕ , dependent on the assembly bias parameter p. Using IllustrisTNG hydrodynamical simulations, we select a QSO sample reflecting the selection criteria and properties of DESI QSOs, and provide a robust prior for p, and thus for b ϕ , building on the findings of Fondi et al. 2024. We find a distribution with mean p̅ ≃ 1.4 with weak redshift dependence, stable to selection noise and consistent with the expected recent merger history typical of quasar-hosting halos. By comparing with the CAMELS simulations we demonstrate that this prior is robust to astrophysical assumptions and cosmic variance. Finally, applying this prior to the DESI DR1 dataset, we derive updated constraints on local PNG, obtaining f NL = -3.3±9.2.

cosmological parameters from LSS

Final Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

Assessment of Molybdate Based Corrosion Inhibitor for use at the Savannah River Tank Farm Cooling Water System

The Savannah River Site (SRS) has relied on 51 underground storage tanks, many dating back to the 1950s, to store radioactive liquid waste generated from nuclear processing and radionuclide production. These tanks use carbon steel cooling coils, cooled by soft, acidic water, to dissipate the decayed heat produced by radioactive waste. For decades, following historical industry practices, chromate has been added to the cooling water (~450 ppm at pH 9-11) to effectively inhibit corrosion, ensuring cooling coil longevity. Inspections of failed coils reveal that chromate-treated surfaces are generally well-preserved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi

An Overview of the NASA Aerospace Flight Battery Systems Program

The NASA Aerospace Flight Battery Systems Program is an agency-wide effort aimed at ensuring the quality, safety, reliability and performance of flight battery systems for NASA applications. The program provides for the validation of primary and secondary cell and battery level technology advances to ensure their availability and readiness for use in NASA missions. It serves to bridge the gap between the development of technology advances and the realization and incorporation of these advances into mission applications. The program is led by the Glenn Research Center and involves funded task activities at each of the NASA mission centers and JPL. The overall products are safe, reliable, high quality batteries for mission applications. The products are defined along three product lines: 1. Battery Systems Technology - Elements of this task area cover the systems aspects of battery operation and generally apply across chemistries. This includes the development of guidelines documents, the establishment and maintenance of a central battery database that serves a central repository for battery characterization and verification test data from tests performed under the support of this program, the NASA Battery Workshop, and general test facility support. 2. Secondary Battery Technology - l h s task area focuses on the validation of battery technology for nickel-cadmium, nickel-hydrogen, nickel-metal-hydride and lithium-ion secondary battery systems. Standardized test regimes are used to validate the quality of a cell lot or cell design for flight applications. In this area, efforts are now concentrated on the validation and verification of lithium-ion battery technology for aerospace applications. 3. Primary Battery Technology - The safety and reliability aspects for primary lithium battery systems that are used in manned operations on the Shuttle and International Space Station are addressed in the primary battery technology task area. An overview of the task areas supported under this program will be presented.

Manzo, Michelle A.

An Investigation Regarding the Effects of Volume Dynamics on Gas Turbine Engine Performance and Operability

This work explores the impact of adding volume dynamics to an electrified turbofan engine model. The zero-dimensional single-input single-output volume elements capture the physics of fluid compressibility of flow in the engine core gas path turbomachinery during transient operation with greater fidelity. Some background regarding the motivation for this effort is provided. A model of the volume element is developed from first principles. The baseline engine model is described and an explanation is given of the modifications made to incorporate the volume elements into the new model. Details of the simulated inputs, designed to elicit exaggerated dynamic responses and to facilitate comparison between the baseline and modified engine models, are explicated. The results of these simulations are presented and discussed, demonstrating that the transient performance and operability of the modified engine model, measured by parameters such as shaft speeds, thrust, and high-pressure compressor (HPC) stall margin, are impacted by the additional dynamics. Commentary is provided regarding potential explanations for the differences in behavior exhibited by the two models. Finally, suggestions are offered for future work that might improve the volume models developed in this effort and leverage the improved fidelity enabled by the modeling of turbomachinery volume dynamics.

Volume dynamics

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Expansion of Check-Cases for 6DOF Simulation

This is the Appendix containing a description of the solution for Case 1 in the assessment, “Expansion of Check-Cases for 6DOF Simulation”. For cases of spherical gravity, it is possible to provide a two-body solution without recourse to numerical integration and thus it is accurate to machine precision. Python code for a Keplerian Propagator (propagate.py) which produced a reference trajectory for Case 1 is provided in this appendix. There is also code for generating test cases which was used as an independent verification of the propagator. This is a high-level description of the algorithm employed. The documentation of each function includes implementation details, including equations for each task.

Modeling

Boundary Layer Analysis of Shock Tube Flows

Shock tubes offer a controlled environment to reproduce kinetic and radiative phenomena characteristic of atmospheric entry flows under ground-test conditions. The boundary layer developing behind the incident shock wave determines the available test time, influences particle residence times important for similarity scaling, and can affect radiative energy transport. In this study, we couple a quasi-1D space marcher with the compressible boundary-layer equations to numerically compute the post-shock flow in a shock frame of reference for various test gas mixtures representative of different planetary atmospheres. The solvers are individually verified against CFD simulations and analytical correlations available in the literature. Coupled solutions are computed for a finite-rate chemistry in the boundary layer and a non-catalytic isothermal wall. Results yield refined estimates of the maximum separation distance, as well as insights into concentration profiles of relevant species within the boundary layer.

Andrea Fagnani

Core-Centering of Compound Drops in Capillary Oscillations: Observations on USML-1 Experiments in Space

Using the existing inviscid theories, an attempt is made to explain the centering of the oscillating liquid shell. Experiments on liquid shells and liquid-core compound drops were conducted using acoustic levitation, in a low-gravity environment during a Space Shuttle flight. It was observed that their inner and outer interfaces became concentric when excited into capillary oscillations. Using the existing inviscid theories, and attempt is made to explain the centering of the oscillating liquid shell. It is concluded that viscosity needs to be considered in order to provide a realistic description of the centering process.

T G Wang

Universal Relationship between Limiting Current and Electrochemical Transport Properties in Malonate-Based Polymer Electrolytes

There is considerable interest in developing high-performance electrolytes for rechargeable lithium batteries. For practical applications, the electrolyte must support large dc currents. However, the parameters most often reported in the literature, conductivity, κ, and current fraction, ρ + , reflect ion transport in the limit of infinitesimal currents. In this limit, the efficacy of an electrolyte is given by the product κρ + . The limiting current density, i lim , is the maximum current density that can be applied across an electrolyte; the cell voltage diverges if the applied current density exceeds ilim. This parameter reflects ion transport in the limit of large dc currents and is therefore of practical interest. It would therefore be convenient if i lim could be predicted from measurements of κρ + . In order to explore this possibility, we studied six malonate-based polymers and PEO at a fixed salt concentration (r = 0.08) and temperature (90°C) using symmetric cells with planar electrodes. Unfortunately, there is no correlation between ilim and κρ + . When the applied current density, i, is less than ilim, the cell voltage approaches a stable plateau, ϕ plateau . Here, we found a linear dependence between i and thickness-normalized plateau potential, ϕ plateau L –1 , irrespective of the magnitude of the applied current. In all seven polymer electrolytes, we found a linear correlation between ilim and the slopes of these lines, σ. In other words, measurements of σ can be used to predict the limiting current.

Jana, Rounak [Lawrence Berkeley National Laborator

MRV Challenge 3: velocity and passive scalar comparison in a 3D turbulent flow

The third iteration of a magnetic resonance velocimetry (MRV) challenge comparison activity consisting of 3D flow measurements for a turbulent flow in a water channel moving past centrally positioned cubic obstacles is reported. In this challenge iteration, MRV measurements are coupled with either temperature or concentration measurements to extend the diagnostic utility. Five research teams from around the world conducted the measurements on a single shared apparatus. The water channel included partial elements along the channel sidewalls that varied in height and precluded easy optical accessibility. In addition to a turbulent mainstream flow, a secondary flow entered the channel between the second and third cubic elements from a square injector hole at the channel bottom wall. The injector jet interacts with the mainstream flow and mixes turbulently as it advects downstream. For the selected flow regime and water solutions used as working fluids, the mixing of the higher temperature or concentration through the secondary flow with the mainstream flow satisfies the same dynamics so that both temperature and concentration fields behave as passive scalars and can be directly compared. The measurements are explained in detail by each participating team, and the results are interpolated onto a common grid and compared using line profiles, contour plots, and isosurfaces.

Benson, Mike [ORNL] (ORCID:000000023210116X)

Mitigating Sodium Ordering for Enhanced Solid Solution Behavior in Layered NaNiO 2 Cathodes

The O-type layered nickel oxides suffer from undesired cooperative Jahn–Teller distortion stemming from Ni 3+ ions and undergo multiple biphasic structural transformations during the insertion/extraction of large Na + ions, posing a significant challenge to stabilize the structural integrity. We present here a systematic investigation of the impact of substituting 5 % divalent (Mg 2+ ) or trivalent (Al 3+ or Co 3+ ) ions for Ni 3+ to alleviate Na + ion ordering and perturb the Jahn–Teller effect to enhance structural stability. Here, we gauge a fundamental understanding of the Mg−O and Na−O or Mg−O−Na bonding interactions, noting that the ionicity of the Mg−O bond deshields the electronic cloud of oxygen from Na + ions. Furthermore, calculations of the Van Vleck distortion modes reveal a relaxation of NiO 6 octahedra from Jahn–Teller distortion and a reduced electron density at the interlayer with Mg 2+ substitution. Long-range (operando X-ray diffraction) and short-range (magic angle spinning nuclear magnetic resonance) structural analyses provide insights into reduced ordering, allowing a stable continuous solid solution. Overall, Mg-substitution results in a high-capacity retention of ~96 % even after 100 cycles, showcasing the potential of this strategy for overcoming the structural instabilities and enhancing the performance of sodium-ion batteries.

25 ENERGY STORAGE