Relative effectiveness of HZE iron-56 particles for the induction of cytogenetic damage in vivo

One of the risks of prolonged manned space flight is the exposure of astronauts to radiation from galactic cosmic rays, which contain heavy ions such as (56)Fe. To study the effects of such exposures, experiments were conducted at the Brookhaven National Laboratory by exposing Wistar rats to high-mass, high-Z, high-energy (HZE) particles using the Alternating Gradient Synchrotron (AGS). The biological effectiveness of (56)Fe ions (1000 MeV/nucleon) relative to low-LET gamma rays and high-LET alpha particles for the induction of chromosome damage and micronuclei was determined. The mitotic index and the frequency of chromosome aberrations were evaluated in bone marrow cells, and the frequency of micronuclei was measured in cells isolated from the trachea and the deep lung. A marked delay in the entry of cells into mitosis was induced in the bone marrow cells that decreased as a function of time after the exposure. The frequencies of chromatid aberrations and micronuclei increased as linear functions of dose. The frequency of chromosome aberrations induced by HZE particles was about 3.2 times higher than that observed after exposure to (60)Co gamma rays. The frequency of micronuclei in rat lung fibroblasts, lung epithelial cells, and tracheal epithelial cells increased linearly, with slopes of 7 x 10(-4), 12 x 10(-4), and 11 x 10(-4) micronuclei/binucleated cell cGy(-1), respectively. When genetic damage induced by radiation from (56)Fe ions was compared to that from exposure to (60)Co gamma rays, (56)Fe-ion radiation was between 0.9 and 3.3 times more effective than (60)Co gamma rays. However, the HZE-particle exposures were only 10-20% as effective as radon in producing micronuclei in either deep lung or tracheal epithelial cells. Using microdosimetric techniques, we estimated that 32 cells were hit by delta rays for each cell that was traversed by the primary HZE (56)Fe particle. These calculations and the observed low relative effectiveness of the exposure to HZE particles suggest that at least part of the cytogenetic damage measured was caused by the delta rays. Much of the energy deposited by the primary HZE particles may result in cell killing and may therefore be "wasted" as far as production of detectable micronuclei is concerned. The role of wasted energy in studies of cancer induction may be important in risk estimates for exposure to HZE particles.

Non-NASA Center↗

Rejoining and misrejoining of radiation-induced chromatin breaks. IV. Charged particles

We have recently reported the kinetics of chromosome rejoining and exchange formation in human lymphocytes exposed to gamma rays using the techniques of fluorescence in situ hybridization (FISH) and premature chromosome condensation (PCC). In this paper, we have extended previous measurements to cells exposed to charged particles. Our goal was to determine differences in chromatin break rejoining and misrejoining after exposure to low- and high-linear energy transfer (LET) radiation. Cells were irradiated with hydrogen, neon, carbon or iron ions in the LET range 0.3-140 keV/microm and were incubated at 37 degrees C for various times after exposure. Little difference was observed in the yield of early prematurely condensed chromosome breaks for the different ions. The kinetics of break rejoining was exponential for all ions and had similar time constants, but the residual level of unrejoined breaks after prolonged incubation was higher for high-LET radiation. The kinetics of exchange formation was also similar for the different ions, but the yield of chromosome interchanges measured soon after exposure was higher for high-LET particles, suggesting that a higher fraction of DNA breaks are misrejoined quickly. On the other hand, the rate of formation of complete exchanges was slightly lower for densely ionizing radiation. The ratios between the yields of different types of aberrations observed at 10 h postirradiation in prematurely condensed chromosome preparations were dependent on LET. We found significant differences between the yields of aberrations measured in interphase (after repair) and metaphase for densely ionizing radiation. This difference might be caused by prolonged mitotic delay and/or interphase death. Overall, the results point out significant differences between low- and high-LET radiation for the formation of chromosome aberrations.

NASA Center JSC↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Improvements in Ross type astrometric objectives

It is shown that aspheric deformations of the first and fourth elements of the four element Ross objective can be introduced to permit one to obtain improved color corrections for astrometric purposes. The usual monochromatic aberrations are as well corrected as for the standard Ross lens. In addition, one can eliminate or reduce additional aberrations, such as secondary spectrum, chromatic spherical aberration, chromatic coma and chromatic distortion. The resulting objectives are suitable for use as intermediate and long focus astrometric objectives covering large angle fields.

Baker, J.↗

Investigation of uses of holographic optical elements

The data represent a thorough study of the aberrations and imaging properties of holographic optical elements. Principle studies include (1) the indepth experimental investigation of single holographic optical elements, (2) the verification of the accuracy of the theoretical computer-based description of hologram behavior, (3) the computer-generation of interferograms that are characteristic of a prescribed aberrated imaging condition, (4) the experimental verification of wavelength optimization, (5) the experimental determination of the space bandwidth product of single holographic optical elements as a function of bending and field angle, and (6) the first experimental study of the aberration properties of holographic optical elements constructed in very thick (750 microns) recording media.

Zech, R. G.↗

Wavefront error simulator for evaluating optical testing instrumentation

A wavefront error simulator has been designed and fabricated to evaluate experimentally test instrumentation for the Large Space Telescope (LST) program. The principal operating part of the simulator is an aberration generator that introduces low-order aberrations of several waves magnitude with an incremented adjustment capability of lambda/100. Each aberration type can be introduced independently with any desired spatial orientation.

Golden, L. J.↗

Measuring concave diffraction grating efficiencies at grazing incidence

The efficiency of a concave diffraction grating in a given order is obtained by measuring the intensities of the diffracted and incident beams and taking their ratio. A valid measurement requires that both the incident and diffracted beams be collected by the detector. At grazing incidence, however, the diffracted beam may spread beyond the detector due to aberrations. In addition, the diffracted beams of consecutive orders may overlap so that unambiguous efficiency measurements cannot be made. The effect of aberrations on efficiency measurements has been studied, using ray tracing, for the geometry of the measuring instrument in use at the Naval Research Laboratory. This instrument is attached to a VUV monochromator which furnishes a diverging beam. The main effect of aberrations for this instrument is a spread of the diffracted beam in the direction of dispersion. The width of the diffracted beam is wavelength dependent and is minimal at the horizontal focus, spreading to longer and shorter wavelengths. Reducing the divergence of the incident beam reduces the spread but, for small radius gratings, not always sufficiently so that the entire diffracted beam can be collected by the detector. The distance from the detector to the grating can also be adjusted to aid in collecting all the diffracted beam.

Hunter, W. R.↗

Second moments of optical degradation due to a thin turbulent layer

The effect of thin turbulent layers, including boundary layers and shear layers, on light propagation is examined from a theoretical point of view. In particular, a mathematical model is developed to describe the interaction between the aerodynamic or, more precisely, the density fluctuations and the electromagnetic field. It is assumed that the turbulence induces a normally distributed phase aberration which is a homogeneous random function in the plane of the aperture. Hypotheses concerning the density fluctuations in the layer sufficient to guarantee such a phase aberration are exhibited. The optical degradation is described in terms of the optical transfer function (OTF) and the Strehl ratio (I/I O ) which are random. Expressions for the first and second moments of these two parameters are developed from the definitions. Asymptotic ("large" aperture) approximations to these expressions are derived and discussed. Finally, the exact and approximate results are compared for several "typical" values of the ratios of aperture diameter to scale of density fluctuations and rms phase aberration to wave length respectively.

W J Steinmetz↗

Curved Surface Beam Splitter

Beam splitter with curved entrance and exit surfaces introduces less chromatic aberration and Seidel aberrations in some optical systems than traditional plate or block beam splitters. Spherical-surface beam splitter is used in Schmidt-type mirror objective to split converging image-forming beam so two images are formed. Small aberrations introduced are corrected by compensator plate located at or near aperture stop.

Minott, P. O.↗

X-ray spectrograph design

An aberration theory is applied to spectrograph design. The initial system considered has a toroidal mirror in front of a concave grating spectrograph, giving spatial resolution perpendicular to the dispersion direction. The accuracy of the theory is shown by comparison of spot diagrams obtained from the aberrations with those produced by raytracing. The major aberrations affecting the vignetting at the intermediate slit and the spatial resolution are identified. A new system, using a holographic grating to give a flat focal plane, is then designed and optimized. It has increased spatial resolution over the wavelength range and is particularly suitable for microchannel array detectors.

Chrisp, M. P.↗

Optimal wavefront control for adaptive segmented mirrors

A ground-based astronomical telescope with a segmented primary mirror will suffer image-degrading wavefront aberrations from at least two sources: (1) atmospheric turbulence and (2) segment misalignment or figure errors of the mirror itself. This paper describes the derivation of a mirror control feedback matrix that assumes the presence of both types of aberration and is optimum in the sense that it minimizes the mean-squared residual wavefront error. Assumptions of the statistical nature of the wavefront measurement errors, atmospheric phase aberrations, and segment misalignment errors are made in the process of derivation. Examples of the degree of correlation are presented for three different types of wavefront measurement data and compared to results of simple corrections.

Downie, John D.↗

Image inversion analysis of the HST OTA (Hubble Space Telescope Optical Telescope Assembly), phase A

Technical work during September-December 1990 consisted of: (1) analyzing HST point source images obtained from JPL; (2) retrieving phase information from the images by a direct (noniterative) technique; and (3) characterizing the wavefront aberration due to the errors in the Hubble Space Telescope (HST) mirrors, in a preliminary manner. This work was in support of JPL design of compensating optics for the next generation wide-field planetary camera on HST. This digital technique for phase retrieval from pairs of defocused images, is based on the energy transport equation between these image planes. In addition, an end-to-end wave optics routine, based on the JPL Code 5 prescription of the unaberrated HST and WFPC, was derived for output of the reference phase front when mirror error is absent. Also, the Roddier routine unwrapped the retrieved phase by inserting the required jumps of +/- 2(pi) radians for the sake of smoothness. A least-squares fitting routine, insensitive to phase unwrapping, but nonlinear, was used to obtain estimates of the Zernike polynomial coefficients that describe the aberration. The phase results were close to, but higher than, the expected error in conic constant of the primary mirror suggested by the fossil evidence. The analysis of aberration contributed by the camera itself could be responsible for the small discrepancy, but was not verified by analysis.

Litvak, M. M.↗

Evaluation of optical systems designed using the 'concentric-aplanatic' method

After reviewing third-order aberration theory, three examples are given of the design of lenses by the concentric-aplanatic method. The performance of any optical system designed with this method can be improved by releasing all the constraints one by one. After correcting for third-order aberrations, the error function can be inspected to determine if the system is dominated by third- or higher-order aberrations.

Deslis, Apostolos↗

In-flight performance of the Faint Object Camera of the Hubble Space Telescope

An overview of the Faint Object Camera and its performance to date is presented. In particular, the detector's efficiency, the spatial uniformity of response, distortion characteristics, detector and sky background, detector linearity, spectrography, and operation are discussed. The effect of the severe spherical aberration of the telescope's primary mirror on the camera's point spread function is reviewed, as well as the impact it has on the camera's general performance. The scientific implications of the performance and the spherical aberration are outlined, with emphasis on possible remedies for spherical aberration, hardware remedies, and stellar population studies.

Greenfield, P.↗

Faint Object Spectrograph (FOS) early performance

The on-orbit performance of the HST + FOS instrument is described and illustrated with examples of initial scientific results. The effects of the spherical aberration from the misfiguring of the HST primary mirror upon isolated point sources and in complex fields such as the nuclei of galaxies are analyzed. Possible means for eliminating the effects of spherical aberration are studied. Concepts include using image enhancement software to extract maximum spatial and spectral information from the existing data as well as several options to repair or compensate for the HST's optical performance. In particular, it may be possible to install corrective optics into the HST which will eliminate the spherical aberration for the FOS and some of the other instruments. The more promising ideas and calculations of the expected improvements in performance are briefly described.

Harms, Richard↗

Combining ray-trace and diffraction analysis: A design example

An example is presented of using a combined ray trace and diffraction modeling code to simulate effects of objective-lens tilt in an optical data storage device. In some cases, neither ray-trace analysis nor diffraction analysis can give an adequate description of an optical system. The designer that is faced with the problem of analyzing such a system is forced to use a ray-trace program to determine aberrations in the exit pupil and then introduce aberration coefficients into a diffraction model that simulate the propagation. This approach was found rather awkward, especially if complicated aberrations are present. Our approach is to integrate a diffraction analysis and a ray-trace description of an optical path into one program. Our design is taken from a data storage application, where we must analyze the effects of objective-lens tilt.

Milster, Tom D.↗

Optical system analysis for the ground based EXVM

The MSFC's Experimental Vector Magnetograph (EXVM) is an instrument that observes a 4.4 x 8.8 arcmin field of the sun. The transverse and longitudinal components of the surface magnetic field and the line-of-sight velocities of the photospheric gases can be determined from polarimetric and spectral analysis of the 525.02 nm absorption line of Fe 1. The EXVM has been breadboarded and tested in the laboratory. The optics of the EXVM were tested with a point-diffraction (Smartt) interferometer. The 12 inch Cassegrain telescope was found to have 0.20 waves RMS (at 525.02 nm) of aberration. The post-telescope relay optics were nearly diffraction limited on-axis and had about one wave of primary coma as the predominant aberration at full-field. From theoretical modulation transfer function (MTF) curves of known aberrations, it was concluded that the EXVM should attain a maximum spatial resolution of about 0.5 arcseconds. A resolution test target indicated maximum angular resolutions better than 0.6 arcsec on-axis and 0.7 arcsec at full-field-of-view. A 2D inch heliostat (sun-tracking mirror) was used to direct sunlight into the lab and into the EXVM. Solar images obtained were limited by atmospheric seeing effects. During brief moments of good seeing, angular resolutions of about 1 arcsecond were realized with the EXVM.