Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Accelerator and Beam Physics Research Goals and Opportunities

This report is a summary of two preparatory workshops, documenting the community vision for the national accelerator and beam physics research program. It identifies the Grand Challenges of accelerator and beam physics (ABP) field and documents research opportunities to address these Grand Challenges. This report will be used to develop a strategic research roadmap for the field of accelerator science.

43 PARTICLE ACCELERATORS↗

Optimization of Drive-Bunch Current Profile for Enhanced Transformer Ratio in Beam-Driven Acceleration Techniques

In recent years, wakefield acceleration has gained attention due to its high acceleration gradients and cost effectiveness. In beam-driven wakefield acceleration, a critical parameter to optimize is the transformer ratio. It has been shown that current shaping of electron beams allows for enhanced (> 2) transformer ratios. In this paper we present the optimization of the pulse shape of the drive bunch for dielectric-wakefield acceleration.

43 PARTICLE ACCELERATORS↗

Generation of quasi-monochromatic beams of accelerated electrons during interaction of weak-contrast intense femtosecond laser radiation with a metal-foil edge

The formation of monoenergetic beams of accelerated electrons by focusing femtosecond laser radiation with an intensity of 2 Multiplication-Sign 10{sup 17} W cm{sup -2} onto an edge of aluminium foil has been experimentally demonstrated. The electrons had energy distributions peaking in the range from 0.2 to 0.8 MeV and an energy spread less than 20 %. The acceleration mechanism related to the generation of a plasma wave as a result of self-modulation instability of the laser pulse in the subcritical plasma formed the prepulse of the laser system (arriving 10 ns before the main pulse) is considered. Onedimensional PIC simulation of the interaction between the laser radiation and plasma with a concentration of 5 Multiplication-Sign 10{sup 19} cm{sup -3} showed that effective excitation of a plasma wave, as well as the trapping and acceleration of the electron beam with an energy on the order of 1 MeV, may occur in the presence of inhomogeneities in the density at the plasma boundary and in the temporal shape of the beam. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decay curve study in a standard electron capture decay

We have searched for a time-modulated decay in a standard electron capture experiment for {sup 140}Pr, in order to confirm a report from GSI, where an oscillatory decay has been observed for hydrogen-like {sup 140}Pr and {sup 142}Pm ions in the cooler storage ring. {sup 140}Pr has been produced with the {sup 140}Ce(p, n) reaction by a pulsed proton beam accelerated from the Van de Graaff accelerator at Osaka University. Resultant time dependence of the K{sub a}lpha and K{sub b}eta X-ray intensities from the daughter shows no oscillatory behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental demonstration of accelerating a beam with a large transverse emittance ratio in the relativistic heavy ion collider for the electron-ion collider

The electron-ion collider (EIC), to be constructed at Brookhaven National Laboratory, will collide polarized high-energy electron beams with hadron beams, achieving luminosities of up to 1.0 × 10 34 cm −2 s −1 in the center-of-mass energy range of 20–140 GeV. To reach such high luminosity, the EIC will employ small, flat beams at the interaction point. According to the design of the EIC hadron storage ring (HSR), hadron beams with a large transverse emittance ratio of 11:1 will be generated at the injection energy using an electron cooling technique and then accelerated to high energies for collisions. Accelerating hadron beams with such a large emittance ratio had never been demonstrated elsewhere—until our recent beam experiment at the relativistic heavy ion collider (RHIC). In this experiment, we successfully generated a large transverse emittance ratio of 13:1 with a gold-ion beam at 31 GeV/nucleon using stochastic cooling. We then accelerated this beam, with a transverse emittance ratio of 11:1, from 31 to 100 GeV/nucleon. Thanks to RHIC’s high-performance orbit, tune, and decoupling feedback systems, the large emittance ratio was well maintained throughout the 5-min-long acceleration process. This experiment fully validated the EIC/HSR design assumptions—namely, that large-emittance-ratio hadron beams can be generated at injection energy and then accelerated to high energies for collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Energy Laser-Accelerated Electron Beams for Long-Range Interrogation

We are studying the use of 0.1–1.0 GeV laser-accelerated electron beams as active interrogation probes for long-standoff radiography or nuclear activation of concealed special nuclear material. Use of beams in this energy range is largely unexplored, but such beams could provide notable advantages over lower-energy beams and x-rays. High-energy laser-accelerated electrons exhibit large penetration range through air and solids, and low beam divergence for both direct beams and secondary Bremsstrahlung x-rays. We present laboratory measurements of radiography and activation, using the high-power Diodes laser system at the University of Nebraska, as well as MCNP and GEANT Monte Carlo simulation results used to aid experiment design and interpretation.

43 PARTICLE ACCELERATORS↗

Jefferson Lab: Present and Future

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab (JLab) comprise a unique facility for nuclear physics research whose upgrade is presently underway, with completion expected in 2017. The upgraded facility will accelerate electron beams to 11 GeV for experiments in the existing Halls A, B and C. In addition, a 12 GeV beam can be provided to a new experimental hall, Hall D, to generate a 9 GeV tagged photon beam. This upgrade will enable a new experimental program with substantial discovery potential to address important topics in hadronic, nuclear, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility (EIC).

Rossi, Patrizia↗

Stark spectroscopy of a probe lithium beam excited with two dye lasers as a technique to study a high-power ion-beam diode

A non-disturbing measurement of electric field distributions is a subject of special interest in plasma physics and high-voltage devices. In this paper we describe a diagnostic technique for remote sensing of electric fields via injection of a probe beam of lithium atoms and cascade excitation of resonance fluorescence with two broadband dye lasers. The fluorescence spectrum was recorded using a monochromator equipped with an optical multi-channel analyser. The magnitude of the local electric field was retrieved from the Stark-shifted components of the 3d-2plithium spectral line. The technique was applied to measurements of the electric field in the applied-B-field high-voltage diode of the 1 TW KALIF ion-beam accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-frequency recirculating planar magnetrons

The multi-frequency recirculating planar magnetron (MFRPM) is the first magnetron capable of simultaneous generation of significantly different output frequencies (1 and 2 GHz) in a single operating pulse. Design and simulation of a prototype MFRPM were followed by hardware fabrication and experimental verification using the Michigan Electron Long Beam Accelerator with a Ceramic insulator at −300 kV, 1–5 kA, and 0.14–0.23 T axial magnetic field. Preliminary results demonstrated simultaneous generation of microwave pulses near 1 GHz and 2 GHz at powers up to 44 MW and 21 MW, respectively, with peak total efficiencies up to 9%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics reach at JLab with the 12 GeV upgrade

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for nuclear physics research whose upgrade has been just completed. The upgraded facility accelerates electron beams to 11 GeV for experiments in the existing Halls A, B and C. In addition, a 12 GeV beam is provided to a new experimental Hall D to generate a 9 GeV tagged photon beam. This upgrade will quantitatively address the nature of confinement and an era of nuclear femtography through precision measurements of the spectrum and structure of hadrons comprised of light quarks and gluons. This facility also provides new opportunities relevant to neutrino oscillation physics, ``dark photon'' searches, and precision tests of the standard model.

Rossi, Patrizia↗

Evidence for Oscillating Two-Stream Instability and Spatial Collapse of Langmuir Waves in a Solar Type II Radio Burst

We present the high time resolution in situ observations of Langmuir waves, likely excited by an electron beam accelerated by a coronal-mass ejection-driven super-critical quasi-perpendicular interplanetary shock into its upstream solar wind, which happens to be the source region of a solar type II radio burst. We show that (1) these waves occur as coherent localized magnetic-field-aligned, one-dimensional wave packets with durations of a few milliseconds and with peak intensities well in excess of the threshold for strong turbulence processes, (2) they provide what is believed to be the first evidence for: (a) the oscillating two-stream instability (OTSI) L(sub 1) + L(sub 2) S/⟶ U + D, where L(sub 1) and L(sub 2), U and D, and S are the pump Langmuir waves, up- and down-shifted side bands, and ion sound waves, respectively, (b) a three-wave interaction U + D ⟶ T(sub 2f(sub pe)), where T(sub 2f(sub pe)) is the second harmonic electromagnetic wave, (3) they satisfy the threshold condition for formation of collapsing solitons, and (4) they are accompanied by their ponderomotive force induced density cavities with δn(sub p)/n(sub e) > δn(sub b)/n(sub e), where δn(sub p)/n(sub e) is the level of ponderomotive force induced density fluctuations and δn(sub b)/n(sub e) is that of the ambient fluctuations. These findings strongly suggest that the observed wave packets provide evidence for the collapsing solitons formed as a result of OTSI. The implication is that the strong turbulence processes probably play very important roles in excitation of type II radio emissions as well as in stabilization of shock-accelerated electron beams.

Sun radio radiation↗

Intense ion beams as a tool for opacity measurements in warm dense matter

Opacity measurements in warm dense matter (WDM) provide a valuable benchmark for the diverging theoretical models in this regime. Heating of thin foils with intense heavy-ion beams allows one to create isolated samples of warm dense matter suitable for experimental determination of frequency-dependent opacities. A prerequisite for the measurements is the isothermal expansion of the heated foil. Hydrodynamic simulations predict that this condition is fulfilled. The analysis shows that existing ion-beam accelerators are capable to contribute to this field of research.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-energy Laser-accelerated Electron Beams for Long-range Interrogation

We are studying the use of 0.1-1.0 GeV laser-accelerated electron beams as active interrogation probes for long-standoff radiography or nuclear activation of concealed special nuclear material. Use of beams in this energy range is largely unexplored, but such beams could provide notable advantages over lower-energy beams and x-rays. High-energy laser-accelerated electrons exhibit large penetration range through air and solids, and low beam divergence for both direct beams and secondary Bremsstrahlung x-rays. We present laboratory measurements of radiography and activation, using the high-power Diodes laser system at the University of Nebraska, as well as MCNP and GEANT Monte Carlo simulation results used to aid experiment design and interpretation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detector calibration of the Indian cosmic ray experiment (IONS) in Space-Shuttle Spacelab-13

In the Indian cosmic ray experiment (IONS) in Spacelab-3 the intention is to study nuclei up to iron in low energy cosmic rays, using CR-39 (DOP) detectors. CR-39 (DOP) was exposed to He4, C12, O16, Ne20, Si28, Ar40, Cr52 and Fe56 accelerated beams from various accelerator facilities available around the world. Different beam energies and exposure angles were used. From these exposures, the charge resolution and energy resolution for the detector in the region of interest were studied. The effect of pre-annealing and depth on the response of our detector was studied. For isotopic resolution, exposed the detector samples were exposed to Ne2O and Ne22 accelerated beams. Samples of CR-39 (DOP) exposed to different accelerated heavy ions were kept in the detector module to take into account the effect of ambient conditions on detector response during the flight.

Yadav, J. S.↗

Comparison of Target Registration Errors for Multiple Image-Guided Techniques in Accelerated Partial Breast Irradiation

Purpose: External beam accelerated partial breast irradiation requires accurate localization of the target volume for each treatment fraction. Using the concept of target registration error (TRE), the performance of several methods of target localization was compared. Methods and Materials: Twelve patients who underwent external beam accelerated partial breast irradiation were included in this study. TRE was quantified for four methods of image guidance: standard laser-based setup, kilovoltage imaging of the chest wall, kilovoltage imaging of surgically implanted clips, and three-dimensional surface imaging of the breast. The use of a reference surface created from a free-breathing computed tomography scan and a reference surface directly captured with three-dimensional video imaging were compared. The effects of respiratory motion were also considered, and gating was used for 8 of 12 patients. Results: The median value of the TRE for the laser, chest wall, and clip alignment was 7.1 mm (n = 94), 5.4 mm (n = 81), and 2.4 mm (n = 93), respectively. The median TRE for gated surface imaging based on the first fraction reference surface was 3.2 mm (n = 49), and the TRE for gated surface imaging using the computed tomography-based reference surface was 4.9 mm (n = 56). The TRE for nongated surface imaging using the first fraction reference surface was 6.2 mm (n = 25). Conclusions: The TRE of surface imaging using a reference surface directly captured with three-dimensional video and the TRE for clip-based setup were within 1 mm. Gated capture is important for surface imaging to reduce the effects of respiratory motion in accelerated partial breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of high-energy radiation generation from laser-wakefield accelerated electron beams

Using high-energy (∼0.5 GeV) electron beams generated by laser wakefield acceleration (LWFA), bremsstrahlung radiation was created by interacting these beams with various solid targets. Secondary processes generate high-energy electrons, positrons, and neutrons, which can be measured shot-to-shot using magnetic spectrometers, short half-life activation, and Compton scattering. Presented here are proof-of-principle results from a high-resolution, high-energy gamma-ray spectrometer capable of single-shot operation, and high repetition rate activation diagnostics. We describe the techniques used in these measurements and their potential applications in diagnosing LWFA electron beams and measuring high-energy radiation from laser-plasma interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam power scale-up in micro-electromechanical systems based multi-beam ion accelerators

We report on the development of multi-beam RF linear ion accelerators that are formed from stacks of low cost wafers and describe the status of beam power scale-up using an array of 120 beams. The total argon ion current extracted from the 120-beamlet extraction column was 0.5 mA. The measured energy gain in each RF gap reached as high as 7.25 keV. We present a path of using this technology to achieve ion currents >1 mA and ion energies >100 keV for applications in materials processing.

47 OTHER INSTRUMENTATION↗