Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Daily operational impacts on battery degradation in heavy-duty electric drayage trucks

Battery aging is a critical factor influencing the performance, longevity, and cost of ownership of battery electric trucks (BETs). This paper presents a comprehensive evaluation of battery aging for two Li-ion battery chemistries, Nickel-Manganese-Cobalt (NMC) and Lithium-Iron-Phosphate (LFP), accounting for both cycling and calendar aging. In contrast to traditional methods that rely on simplified linear degradation models based on manufacturer-provided data, this study employs semi-empirical aging models calibrated to experimentally collected data. The models are integrated into a detailed vehicle simulation environment, enabling a comprehensive assessment of battery degradation under realistic operating conditions. A case study focusing on heavy-duty electric drayage truck operations in the Port of Savannah, GA, is presented to illustrate the impact on battery pack lifespan of: seasonal variations, daily operational activities, charging strategies, and battery storage conditions. The results illuminate the significance of the battery pack’s state of charge during stationary periods, such as overnight storage or weekend parking, on battery degradation and its potential implications for long-term vehicle viability. Additionally, the study explores how different operational and environmental factors affect battery degradation, offering critical insights into best battery charging and storage practices. Our results demonstrate that LFP outperforms NMC in terms of years of useful life; however, by utilizing charging strategies that minimize the amount of time the battery spends resting at high levels of state-of-charge, the lifespan of the battery pack that uses NMC can nonetheless be increased by more than a factor of two.

25 ENERGY STORAGE↗

Impacts of hybridization and forecast errors on the probabilistic capacity credit of batteries

Battery storage is increasingly identified as being among the least-cost mix of technologies in the evolving U.S. electricity mix. This study explores the marginal capacity credit of batteries using a probabilistic, reliability-based, effective firm capacity method, which we apply for multiple battery power ratings, durations, coupling types, deployment locations, and dispatch profiles within a test system that is based on the Texas Interconnection in the year 2024. We find that the capacity credits for all battery durations depend on their ability to predict the timing of reliability events. Even 1-2 h forecast errors - resulting in early or delayed battery discharging relative to the onset of a reliability event - lead pronounced capacity credit reductions, especially for 4-h duration batteries. Coupling batteries with solar mitigates the uncertainty associated with a shorter-duration battery's availability during reliability events, primarily due to the relatively high solar capacity credit in our test system. Coupled (or hybrid) system designs with oversized solar arrays, the ability to charge the coupled battery with grid energy, and larger batteries lead to the greatest capacity credit benefits of hybridization. We do not see evidence that the hybrid capacity credit exceeds the sum of the separate battery and solar capacity credits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Optimal Operation and Impact Assessment of Distributed Wind for Improving Efficiency and Resilience of Rural Electricity Systems

This project aims to empower rural utilities by developing advanced optimization models and algorithms for effectively integrating distributed wind energy alongside battery storage and other distributed energy resources (DERs). The primary objectives are to reduce peak demand, ensure reliable emergency power supply, and regulate voltage and frequency. To address operational challenges, the project introduces innovative mitigation strategies and ultrafast assessment frameworks to evaluate the impacts of distributed wind and DERs on rural grids, offering actionable solutions to potential issues. Economic viability is assessed through cost-benefit analysis using real rural utility data, ensuring the practical application of the project outcomes.

17 WIND ENERGY↗

Application of Mobile Energy Storage for Enhancing Power Grid Resilience: A Review

Natural disasters can lead to large-scale power outages, affecting critical infrastructure and causing social and economic damages. These events are exacerbated by climate change, which increases their frequency and magnitude. Improving power grid resilience can help mitigate the damages caused by these events. Mobile energy storage systems, classified as truck-mounted or towable battery storage systems, have recently been considered to enhance distribution grid resilience by providing localized support to critical loads during an outage. Compared to stationary batteries and other energy storage systems, their mobility provides operational flexibility to support geographically dispersed loads across an outage area. This paper provides a comprehensive and critical review of academic literature on mobile energy storage for power system resilience enhancement. As mobile energy storage is often coupled with mobile emergency generators or electric buses, those technologies are also considered in the review. Allocation of these resources for power grid resilience enhancement requires modeling of both the transportation system constraints and the power grid operational constraints. These aspects are discussed, along with a discussion on the cost–benefit analysis of mobile energy resources. The paper concludes by presenting research gaps, associated challenges, and potential future directions to address these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Financing Solar + Storage for Small Businesses in Underserved Communities

Solar and solar and battery storage deployment is under-utilized by businesses in low-income and disadvantaged communities, in large part due to system costs and limited or complicated financial options. This document summarizes existing financial tools, discusses important financial barriers, and identifies emerging programs and opportunities to address these barriers.

battery↗

Kauhale 'O Kipapa: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Findings show hybrid PV and battery systems, supplemented by small wind turbines, offer cost-effective, resilient solutions. This work supports enhanced energy independence and disaster preparedness for the community.

Quiroz, Jimmy Edward [Sandia National Laboratories↗

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

backup power↗

Coordinated Wind Power Plant and Battery Control for Active Power Services

This article considers joint active power control of wind turbines and battery storage to follow a plant-level power reference signal. The joint control dynamically curtails the energy from a subset of the wind turbines and stores or withdraws energy from the battery to meet the power reference setpoint while accounting for wind plant aerodynamic interactions, such as wake losses. As a use case, we study the performance of the controller in maintaining a constant power output over hourly periods. A wind plant operating in this way would rely much less on other grid resources to meet its contractual agreements, thereby improving grid reliability, especially in grids with high penetration of wind and solar generation. We compare the operation of the wind plant under joint active power control to standard power-maximizing control with battery support. We present an analysis of the performance of the control system architecture. To study the impact of the battery size on performance, we simulate a 50-MW wind plant supported by batteries ranging from 8 to 64?MWh. We then evaluate the over and undergeneration penalties incurred by the plant during the simulation period.

17 WIND ENERGY↗

Hybrid Grid-Renewable Strategies for Green Steel Production under Electricity Market Uncertainty

Volatility in grid spot prices is expected to rise with climate change-driven demand pressures and the intermittency of renewable generation. This volatility poses financial risks for green hydrogen-based steel production. The Direct Reduced Iron− Electric Arc Furnace (H 2 -DRI-EAF) is a promising pathway to decarbonize steel, which accounts for ∼8% of global GHG emissions. This study assesses how increased grid spot price volatility influences the optimal sizing and operation of H2-DRIEAF plants under three operational scenarios: grid-connected, fully behind-the-meter (islanded), and mixed-mode (semi-islanded). Our analysis identifies the semi-islanded configuration as the most cost-effective solution, achieving a Levelized Cost of Steel (LCOS) 10−35% lower than sourcing energy solely from the grid. Modeling also shows hydrogen storage or selective electricity purchases at high prices (>$1000/MWh) generally outperform battery storage, except under extreme volatility. Additionally, the study explores cost reduction strategies to strengthen the economic viability and sustainability of green steel production.

Batteries↗

The Challenges of Modeling Distributed Energy Resources (DERs) as Blackstart Resources and for Volt-VAR Optimality

Modeling, testing and instituting Distributed Energy Resources (DERs) as Blackstart Resoucrces presents several challenges due to the fundamental differences between traditional black start resources (e.g., large generators) versus DERs like solar PV systems with battery storage. This paper addresses some of these key challenges. These include intermittency of coordinating DERs to provide continuous power during a black start event, especially during extended periods of cloud cover or when battery energy storage is depleted. This paper additionally addresses the collapsing voltage and stability control challenges specific to maintaining bulk power system stability during black start synchronization These physical and engineering limitations require careful engineering design, modeling and engineering to ensure that DERs can support critical loads and substations during black start events. A variety of additional challenges also exist. Additionally, there are challenges associated with feeder location and low voltage secondary system impacts on DER functions and settings. We compare typical functions and settings for DERs for power factor control and correction. We also demonstrate how voltag control via Volta-VAR power factor correction can be done

Mukherjee, Srijib↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Expanding NREL's Advanced Research on Integrated Energy Systems (ARIES) Capabilities

NREL's Integrated Energy Pathways vision represents a transformed, future integrated energy system that is more affordable, clean, secure, and resilient than today. Key to this vision is the unique Advanced Research on Integrated Energy Systems (ARIES) research platform. With a focus on advancing modern grid infrastructure, making investments in energy efficiency building technology research, and innovating battery storage and much more, the unique ARIES research platform can be used to accelerate the integration of new technologies into a modern grid.

advanced research↗

Synergies Between Building-Sited Batteries and Thermal Energy Storage

As renewable penetration increases, there is a greater need for energy storage systems located at buildings. This storage can include batteries, which directly shift the metered load, or thermal energy storage, which shifts thermal-driven electric loads like air conditioning. This presentation covers modeling results of the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. It also shows how battery storage can expand the usefulness of thermal energy storage for electric load shaving, and how thermal storage can lower the cost of the overall storage system and extend battery lifetime by reducing cycling.

batteries↗

A Review of Sandia Energy Storage Research Capabilities and Opportunities (2020 to 2030)

Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Disorder Dynamics in Battery Nanoparticles During Phase Transitions Revealed by Operando Single-Particle Diffraction

Structural and ion-ordering phase transitions limit the viability of sodium-ion intercalation materials in grid scale battery storage by reducing their lifetime. However, the combination of phenomena in nanoparticulate electrodes creates complex behavior that is difficult to investigate, especially on the single-nanoparticle scale under operating conditions. In this work, operando single-particle X-ray diffraction (oSP-XRD) is used to observe single-particle rotation, interlayer spacing, and layer misorientation in a functional sodium-ion battery. oSP-XRD is applied to Na 2/3 [Ni 1/3 Mn 2/3 ]O 2 , an archetypal P2-type sodium-ion-positive electrode material with the notorious P2-O2 phase transition induced by sodium (de)intercalation. Here, it is found that during sodium extraction, the misorientation of crystalline layers inside individual particles increases before the layers suddenly align just prior to the P2-O2 transition. The increase in the long-range order coincides with an additional voltage plateau signifying a phase transition prior to the P2-O2 transition. To explain the layer alignment, a model for the phase evolution is proposed that includes a transition from localized to correlated Jahn-Teller distortions. The model is anticipated to guide further characterization and engineering of sodium-ion intercalation materials with P2-O2 type transitions. oSP-XRD, therefore, opens a powerful avenue for revealing complex phase behavior in heterogeneous nanoparticulate systems.

25 ENERGY STORAGE↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

Fact sheet describes how the Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid to ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

battery storage↗

Long duration battery sizing, siting, and operation under wildfire risk using progressive hedging

Battery sizing and siting problems are computationally challenging due to the need to make long-term planning decisions that are cognizant of short-term operational decisions. This paper considers sizing, siting, and operating batteries in a power grid to maximize their benefits, including price arbitrage and load shed mitigation, during both normal operations and periods with high wildfire ignition risk. Here we formulate a multi-scenario optimization problem for long duration battery storage while considering the possibility of load shedding during Public Safety Power Shutoff (PSPS) events that de-energize lines to mitigate severe wildfire ignition risk. To enable a computationally scalable solution of this problem with many scenarios of wildfire risk and power injection variability, we develop a customized temporal decomposition method based on a progressive hedging framework. Extending traditional progressive hedging techniques, we consider coupling in both placement variables across all scenarios and state-of-charge variables at temporal boundaries. This enforces consistency across scenarios while enabling parallel computations despite both spatial and temporal coupling. The proposed decomposition facilitates efficient and scalable modeling of a full year of hourly operational decisions to inform the sizing and siting of batteries. With this decomposition, we model a year of hourly operational decisions to inform optimal battery placement for a 240-bus WECC model in under 70 min of wall-clock time.

25 ENERGY STORAGE↗