Search NASA⌕ Search

SEARCH · Search NASA

Results for “Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Experimental study of sprays with isooctane, hexane, ethanol and their binary mixtures under different flash boiling intensities

Here, this work investigated the behaviors of single-component and multi-component sprays under different flash boiling intensities. Isooctane, hexane, ethanol, isooctane-hexane, and isooctane-ethanol mixtures were used as test fuels. The pressure ratio of the ambient pressure over saturation pressure (R p ) was used as the indicator of the superheated degree. Macroscopic characteristics of the sprays under 10 different R p (1.1 to 0.14) were investigated using Diffused Backlight Imaging (DBI). Droplet size, which revealed the spray microscopic characteristics, was also investigated using Phase Doppler Anemometry (PDA). The results showed that ambient pressure reduction led to higher flash boiling intensity, significant spray morphology changes, and smaller droplet size, regardless of the fuel type and blend ratios. Spray collapse was observed for all sprays once R p dropped below 0.3. Spray collapse dramatically increased the liquid penetration length, expanded the near-field spray angle, and reduced the far-field angle for sprays with all the fuels. Fuel properties, such as the latent heat of vaporization, had significant impacts on droplet size distributions, thus altering the liquid penetration length and spray angles. Under similar R p , sprays with high ethanol content generally had larger droplet sizes compared with other fuel sprays due to the high latent heat of vaporization. The larger droplets caused the high ethanol content sprays to be more resistant to the plume trajectory change, resulting in a smaller far-field spray angle variations with changing R p . At R p of 0.28, sprays with the similar latent heat of vaporization have similar droplet sizes, and droplet sizes at different radial locations were also similar to each other.

42 ENGINEERING↗

CFD unified approach under Eulerian–Lagrangian framework for methanol and gasoline direct injection sprays in evaporative and flash boiling conditions

Innovative synthetic fuels for advanced propulsion systems, such as methanol and ammonia, and synthetic blended fuels (E00, E10, and E30), known for their high volatility, are often injected directly into combustion chambers. It follows that Eulerian–Lagrangian spray models need to accurately capture the spray collapse as a consequence of flash boiling onset and be capable of proficiently handling the preferential evaporation of multi-component fuels in evaporative scenarios. So, we performed the assessment of an Eulerian–Lagrangian CFD code for simulating methanol and E00 gasoline blend sprays in both early and late injection conditions involving flash boiling conditions and preferential evaporation. The adoption of an effervescent breakup model and of a non-equilibrium phase transition model for the discrete phase allows the adoption of a setup that is almost completely free from specific constant tuning, especially for what concerns the breakup model. We validated the simulations using experimental PLV maps of methanol and E00 sprays issued from the ECN Spray M injector. The results highlight a significantly different morphology of the methanol spray compared to the E00 one under late injection conditions. Under stratified combustion, low-volatile fuels are likely to be ignited first, and the flame propagates toward the high-volatile fuels. In conclusion, the spray collapse was also correctly reproduced, inducing the presence of a low-pressure zone and modifying the spray morphology.

E00↗

A new flow pattern map for flow boiling of R410A in horizontal micro-fin tubes considering the effect of the helix angle

This paper presents an improved flow pattern map for flow boiling in horizontal micro-fin tubes considering the effect of helix angle. The proposed map is modified from the one developed for horizontal smooth tubes by Wojtan et al. (2005) and takes the early transition to annular flow due to micro-fin geometry into account. Visualization of R410A flow boiling is carried out through the transparent smooth and micro-fin tubes with 0°, 10° and 18° helix angle and plotted on the proposed map for comparison. The result shows that the flow pattern map for micro-fin tube with 0° helix angle is generally similar to that for the smooth tube. For the tube with 10° and 18° helix angle, the annular flow occurs at lower vapor quality and lower mass flux. The proposed map shows good agreements when compared with the visualization and reflects the downward shift (to lower mass flux and vapor quality conditions) of the SW-WA transition with the increase of the helix angle. In order to further validate the proposed model, the flow pattern transitions calculated from the equations are also compared with the experimental data of the micro-fin tube in literature. The results show that the modified map increase the prediction accuracy of the flow patterns in the micro-fin tube.

42 ENGINEERING↗

Multi-GPU porting of a phase-change cascaded lattice Boltzmann method for three-dimensional pool boiling simulations

The Lattice Boltzmann method (LBM) has proven effective in simulating phase-change phenomena, such as melting, solidification, evaporation, and boiling. In this work, we develop a highly parallelized multi-GPU implementation of LBM for three-dimensional pool boiling simulations. The code is based on the OpenACC programming model, which enables the code to be deployed efficiently on multi-core CPUs, GPUs, and potentially other accelerators, without the need for architecture-specific rewrites. To support large-scale simulations, the domain is decomposed and distributed across multiple compute nodes using MPI. We demonstrate that the code exhibits excellent scaling properties, with ideal strong-scaling running with up to 256 GPUs on the MareNostrum5 cluster.

97 MATHEMATICS AND COMPUTING↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Zero-G Report ''LH2 Boiling Threshold"

Test to determine minimum temperature difference between heated wall and liquid hydrogen at boiling point required to initiate nucleate boiling under steady state conditions and zero-g.

WALL TEMPERATURE↗

Comparison of Computational Results with a Low-g, Nitrogen Slosh and Boiling Experiment

This paper compares a fluid/thermal simulation, in Fluent, with a low-g, nitrogen slosh and boiling experiment. In 2010, the French Space Agency, CNES, performed cryogenic nitrogen experiments in a low-g aircraft campaign. From one parabolic flight, a low-g interval was simulated that focuses on low-g motion of nitrogen liquid and vapor with significant condensation, evaporation, and boiling. The computational results are compared with high-speed video, pressure data, heat transfer, and temperature data from sensors on the axis of the cylindrically shaped tank. These experimental and computational results compare favorably. The initial temperature stratification is in good agreement, and the two-phase fluid motion is qualitatively captured. Temperature data is matched except that the temperature sensors are unable to capture fast temperature transients when the sensors move from wet to dry (liquid to vapor) operation. Pressure evolution is approximately captured, but condensation and evaporation rate modeling and prediction need further theoretical analysis.

Cryogenic Fluid Storage↗

Zero Boil-Off System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration plans due to their high specific impulse for rocket motors of upper stages. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for long duration missions. These losses can be eliminated by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and modulating the cryocooler temperature to control tank pressure. The technology being developed by NASA is the reverse turbo-Brayton cycle cryocooler and its integration to the propellant tank through a distributed cooling tubing network coupled to the tank wall. This configuration was recently tested at NASA Glenn Research Center in a vacuum chamber and cryoshroud that simulated the essential thermal aspects of low Earth orbit, its vacuum and temperature. This test series established that the active cooling system integrated with the propellant tank eliminated boil-off and robustly controlled tank pressure.

Reverse turbo-Brayton cycle↗

Development and Capabilities of ISS Flow Boiling and Condensation Experiment

An experimental facility to perform flow boiling and condensation experiments in long duration microgravity environment is being designed for operation on the International Space Station (ISS). This work describes the design of the subsystems of the FBCE including the Fluid subsystem modules, data acquisition, controls, and diagnostics. Subsystems and components are designed within the constraints of the ISS Fluid Integrated Rack in terms of power availability, cooling capability, mass and volume, and most importantly the safety requirements. In this work we present the results of ground-based performance testing of the FBCE subsystem modules and test module which consist of the two condensation modules and the flow boiling module. During this testing, we evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, heat loss from different modules and components, and performance of the test modules. These results will be used in the refinement of the flight system design and build-up of the FBCE which is manifested for flight in late 2017-early 2018.

microgravity↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Performance Evaluation of the International Space Station Flow Boiling and Condensation Experiment (FBCE) Test Facility

A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.

microgravity↗

Thermal Model of a Zero Boil Off System for the Nuclear Thermal Propulsion System

NASA is currently developing an updated concept for a nuclear thermal propulsion (NTP) system. To enable this concept, efficient thermal insulation and cryocooler heat exchanger systems are required to eliminate boil-off of propellant. This paper presents the results of a thermal model used to assess the feasibility of using active cooling with a tube-on-tank heat exchanger configuration for the inline tank of the NTP system. Results show that: cryocooler working fluid temperature and mass flow rate can be adjusted to achieve zero boil off (ZBO) with broad area cooling, over-sizing the cryocooler lift directly translates into a reduction in tank pressure, and broad area cooling may still maintain ZBO despite the reduced heat transfer between tank wall and propellant that is expected in reduced gravity.

zero boil off↗

Flow Boiling in Microgap Coolers - Suborbital Flight Results

Flow Boiling in Microgap Coolers (FBMC) is a thermal management technique that provides embedded, on-site heat removal for power dense electronic components and systems. The dielectric coolant undergoes liquid-to-vapor phase change as it passes through channels integrated within or between devices. By facilitating direct contact between the coolant and heat-generating devices and relying on phase change, the system provides tight temperature control, hot spot mitigation, very high heat transfer coefficients, and low pumping power. Ground tests demonstrated removal of high heat fluxes (up to 500 kW/m2), very high coefficients of performance (up to 40 W of heat transferred per W of pumping power), and consistent performance across five evaporator orientations under the appropriate conditions. As a follow-on study and to better assess the role of gravity on such two-phase systems, the FBMC payload was developed and flown twice aboard the Blue Origin New Shepard space vehicle in January and May 2019. Each flight exposed the payload to weightlessness (150 seconds below 0.01 g) and shorter periods of high-g during ascent (up to 3 g) and descent (up to 5 g). The flow boiling performance was consistent independent of the acceleration levels, which provides confidence that such systems will provide consistent performance when tested on the ground, orbiting or traveling through weightlessness, and operating on the surface of the Moon, Mars, and other planetary bodies. Details of the flight results, payload development, flight environment, and planned future testing will be presented.

Flow boiling↗

Topical: Boiling, Condensation and Two-Phase Flows in Microgravity

The white paper addresses both fundamental and technological questions in the science of phase-change fluid flows aimed at understanding thermal transport in flow boiling and condensation and the use of these processes in space and terrestrial thermal systems. While flow boiling and condensation are widely employed in Earth-based thermal equipment to reduce the cost, size, and power required to transfer heat, a lack of data and predictive models on the impact of gravity on these phenomena hinders the use of two-phase heat transport in a low-gravity environment. The white paper presents research tasks in long-duration microgravity recommended to expand our knowledge on phase-changing flows. Due to elimination of the masking gravity effects, the proposed research will provide a unique opportunity to bring new insights into the role of capillary and hydrodynamic forces in phase-changing flows. The potential impact of the proposed research ranges from the space power, thermal and cryogenic systems to various terrestrial applications in the petrochemical, pharmaceutical, biochemical, nuclear, and metallurgical industries.

Phase-change fluid flow↗