Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concentration of measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Rogers Quarry Special Studies Report 2024

Rogers Quarry (RQ) has a history of elevated selenium (Se) concentrations in water and fish caused by inputs from the Y-12 National Security Complex Filled Coal Ash Pond (FCAP). Selenium is acutely toxic at high concentrations, and chronic toxicity occurs at low aqueous concentrations because Se bioaccumulates in fish tissues. The US Environmental Protection Agency (EPA) recently developed water quality criteria for Se that include fish tissue as well as aqueous Se concentrations. The water column concentration criterion is 1.5 µg L -1 for lentic ecosystems and 3.1 µg L -1 for lotic ecosystems. The fish tissue criteria include both an egg/ovary concentration (15.1 µg/g dry weight) and a concentration for whole-body (8.5 µg/g dry weight) or fish muscle (11.3 µg/g dry weight). The egg/ovary criterion supersedes the fillet and aqueous concentrations if measured because Se toxicity manifests via reproductive effects in birds and fish. It is maternally transferred through eggs, leading to teratogenicity (i.e., deformities, developmental effects) in young fish. Historical bioaccumulation data suggest that Se is likely the primary contaminant of concern in RQ, but more recent sampling shows that aqueous As concentrations have been elevated in upper McCoy Branch (MB) leading to RQ. More recently, Se concentrations in fish collected from upper MB were found to be above the tissue criterion for Se for whole-body fish. In FY 2019, actions were taken to deepen the constructed wetland just downstream of the FCAP to increase its ability to remove coal ash particulates from the water column before water enters MB. Sampling was conducted throughout MB in FY 2020-2024 to evaluate the effectiveness of the actions taken in the FCAP wetland and to measure Se concentrations in biota throughout the watershed. The methods and results from a water and fish field collection campaign in April 2024 are presented in this report.

54 ENVIRONMENTAL SCIENCES↗

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sulfuric Acid New Particle Formation Field Campaign Report

This campaign aimed to measure gaseous sulfuric acid concentrations at the surface level using a newly developed sulfuric acid dimethylamine-reactive condensation particle counter (SAD-RCPC). Sulfuric acid is a key nucleation precursor and is the likely driving compound for new particle formation at the Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory. The SAD-RCPC will be deployed in the future at ARM SGP (AFC010010: "Vertically Resolved Nucleation Precursors at SGP") scheduled for 2024. The campaign was in conjunction with Eleanor Browne's campaign (AFC010075: Boundary-layer gradients in new particle formation) and took place from 05/7/23 to 5/21/23. The measured sulfuric acid concentrations by the SAD-RCPC will be compared to concentrations measured by Browne's chemical ionization mass spectrometer (CIMS). The SAD-RCPC consisted of a glass flow reactor coupled to a 1-nm diethylene glycol condensation particle counter (DEG CPC). Sampled air was mixed with a high concentration of dimethylamine vapor (~1 ppbv). Sulfuric acid within the sampled gas nucleated with dimethylamine to form detectable 1-nm particles. The measured particle concentration was converted to sulfuric acid concentration using nucleation reaction kinetics. The pulse height distribution of particles detected by the DEG CPC was observed using a multi-channel analyzer. Large pre-existing particles were separated from the freshly formed particles in the SAD-RCPC from the pulse height distribution (PHD). During the short campaign, seven new particle formation events were observed. The SAD-RCPC detected an increase in sulfuric acid concentration, but this also coincided with an increase in pre-existing <3 nm particle concentrations. In addition, Browne's CIMS detect sulfuric acid concentrations in the range of 10 5 -10 6 cm -3 .

54 ENVIRONMENTAL SCIENCES↗

200-IA-1 Operable Unit Human Health Risk and Kd Screen

The purpose of this environmental calculation file (ECF) is to provide the following: Document the data processing and data reduction steps taken to prepare the 200-IA-1 Operable Unit (OU) data set that will be used to calculate the sample-specific screening level human health risk evaluation; Document the data processing and data reduction steps taken to prepare the 200-IA-1 OU data set that will be used to identify analytes that could potentially impact groundwater in the future beneath the 200-IA-1 OU representative waste sites; Document the assumptions, equations, and methodologies used to calculate the screening levels for human health cancer risks and noncancer hazards for each representative waste site assigned to the 200-IA-1 OU. Individual measured soil concentrations from 0 to 4.6 m (15 ft) below ground surface (bgs) (shallow vadose zone) are used to calculate the total excess lifetime cancer risk (ELCR) and hazard index (HI) for the outdoor worker scenario to determine if there is a basis for remedial action. Individual measured soil concentrations from the ground surface to the groundwater table are used for the distribution coefficient (Kd) screen to identify analytes that could potentially impact groundwater in the future beneath the 200-IA-1 OU representative waste sites. This ECF supports DOE/RL-2020-51, 200-IA-1 OU Focused Feasibility Study, under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). A risk characterization based upon the evaluation of the health risk estimates developed in this ECF will be presented in the focused feasibility study report.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Cloud Condensation Nuclei Particle Counter (CCN) Instrument Handbook

The Cloud Condensation Nuclei Counter—CCN (Figure 1) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility instrument for measuring the concentration of aerosol particles that can act as cloud condensation nuclei [1, 2]. The CCN draws the sample aerosol through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in this process, are counted (and sized) by an Optical Particle Counter (OPC). Thus, activated ambient aerosol particle number concentration as a function of supersaturation is measured. Models CCN-100 and CCN-200 differ only in the number of humidifier columns and related subsystems: CCN-100 has one column and CCN-200 has two columns along with dual flow systems and electronics.

54 ENVIRONMENTAL SCIENCES↗

Total metal, carbon, anion, iron speciation, and sulfide concentrations; Slate River, East River, and Trail Creek surface water and floodplains, Crested Butte, CO; May 2023–August 2023

This data package comprises analytical results and metadata from stream and groundwater samples collected from the Slate River, East River, Trail Creek, and their respective floodplains. This dataset contains five files: (1) a samples file (2023_SFA_Field_samples.csv) that contains site information; (2) a chemical analysis data file (2023_FieldWaterSampleData_IC__ICPOES__ICPMS__TOC__Fe__S_chem_data.csv) that contains sample analysis values; (3) a file-level metadata file (flmd.csv) that lists each file contained in the dataset with associated metadata; (4) a data dictionary file (dd.csv) that contains column/row headers used throughout the files along with definitions, units, and data types; and (5) a methods file (methods.csv) that contains ID, type, description, instrument, and lab information for each method.The samples’ anion concentrations were measured using ion chromatography (IC), total metal concentrations using inductively coupled plasma emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS), non-purgeable organic carbon using total organic carbon (TOC) analysis, dissolved sulfide concentration using methylene blue spectrophotometry, and iron speciation using the ferrozine assay. To support bulk chemical analyses and colloid characterization, samples were collected from multiple depths ranging from the surface to 3.5 meters below ground.Update on 2024-10-18: Updates were made to the 2023_FieldWaterSampleData_IC__ICPOES__ICPMS__TOC__Fe__S_chem_data.csv and dd.csv files to correct units (ppb instead of ppm).

54 ENVIRONMENTAL SCIENCES↗

Subseasonal Variability of Elevated Dust Concentrations Over South Florida

Dust mass concentrations have been measured daily at Miami, Florida, in the summer months, and biweekly throughout the remaining months, since 1974. The 43-year record of dust mass concentrations indicate large daily, seasonal, and interannual variations, with most of the dust arriving within 5–8 episodes each summer. On average, dust arrives to Miami, Florida, 10 days after emission from North Africa, with measured concentrations depending on characteristics of the lower free-tropospheric winds due to the vast travel distance. Daily dust mass concentrations from July and August, the months that contribute the most to the annual mean, are used to characterize the synoptic conditions most favorable for dust transport. Two key regions are linked with the highest daily dust mass concentrations above Miami: (i) easterly winds, averaged over 850–500 mb, over the Tropical West Atlantic [15–25°N, 45–80°W], and (ii) southerly winds, similarly averaged, over the Florida Peninsula [20–30°N,75–80°W]. Winds within these two regions are enhanced when the North Atlantic subtropical high is displaced south and zonally elongated, relocating the western edge over Florida. A dust-transport-efficiency index, based on the maximum potential for dust to arrive above Miami with limited loss to deposition or mixing, identifies high-dust loading cases on the subseasonal scale. Monthly dust-transport-efficiency values agree well with the monthly dust trends over the 43-year time span. While seasonal dust loadings have been decreasing over Florida in the past decade, the transport efficiency has been increasing, possibly due to trends in the North Atlantic subtropical high.

54 ENVIRONMENTAL SCIENCES↗

Sulfuric acid in the Amazon basin: measurements and evaluation of existing sulfuric acid proxies

Abstract. Sulfuric acid is a key contributor to new particle formation, though measurements of its gaseous concentrations are difficult to make. Several parameterizations to estimate sulfuric acid exist, all of which were constructed using measurements from the Northern Hemisphere. In this work, we report the first measurements of sulfuric acid from the Amazon basin. These measurements are consistent with concentrations measured in Hyytiälä, Finland, though, unlike Hyytiälä, there is no clear correlation of sulfuric acid with global radiation. There was a minimal difference in sulfuric acid observed between the wet and dry seasons in the Amazon basin. We also test the efficacy of existing proxies to estimate sulfuric acid in this region. Our results suggest that nighttime sulfuric acid production is due to both a stabilized Criegee intermediate pathway and oxidation of SO2 by OH, the latter of which is not currently accounted for in existing proxies. These results also illustrate the drawbacks of the common substitution of radiation for OH concentrations. None of the tested proxies effectively estimate sulfuric acid measurements at night. For estimates at all times of day, a recently published proxy based on data from the boreal forest should be used. If only daytime estimates are needed, several recent proxies that do not include the Criegee pathway are sufficient. More investigation of nighttime sulfuric acid production pathways is necessary to close the gap between measurements and estimates with existing proxies.

54 ENVIRONMENTAL SCIENCES↗

Application of Cyclic Voltammetry with W Electrodes for Measurement of High CaO Concentration in Molten CaCl 2

Molten CaCl 2 is a useful electrolyte for certain pyroprocessing techniques, and the solubility of oxide ions in this salt is a critical characteristic of many of these techniques. CaO is a byproduct of direct oxide reduction (DOR), so the concentration of oxide ions can be used to determine the extent of these reactions. Using cyclic voltammetry (CV) with tungsten electrodes, the CaO concentration in the salt up to approximately 5 wt% was correlated to both oxidation peak height and power density values. This correlation was demonstrated in both equilibrium and transient conditions. CV is a promising method for the in situ real-time monitoring of CaO concentrations in DOR processes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Measuring Nd(III) Solution Concentration in the Presence of Interfering Er(III) and Cu(II) Ions: A Partial Least Squares Analysis of Ultraviolet–Visible Spectra

Optical spectroscopy is a powerful characterization tool with applications ranging from fundamental studies to real-time process monitoring. However, it can be difficult to apply to complex samples that contain interfering analytes which are common in processing streams. Multivariate (chemometric) analysis has been examined for providing selectivity and accuracy to the analysis of optical spectra and expanding its potential applications. Here we will discuss chemometric modeling with an in-depth comparison to more simplistic analysis approaches and outline how chemometric modeling works while exploring the limits on modeling accuracy. Understanding the limitations of the chemometric model can provide better analytical assessment regarding the accuracy and precision of the analytical result. This will be explored in the context of UV–Vis absorbance of neodymium (Nd 3+ ) in the presence of interferents, erbium (Er 3+ ) and copper (Cu 2+ ) under conditions simulating the liquid–liquid extraction approach used to recycle plutonium (Pu) and uranium (U) in used nuclear fuel worldwide. Finally, the selected chemometric model, partial least squares regression, accurately quantifies Nd 3+ with a low percentage error in the presence of interfering analytes and even under conditions that the training set does not describe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Tank Vapors in Worker Breathing Zones - Source, Dispersion, and Receptor Data - 20373

A wide range of organic and inorganic chemicals from historical Hanford Site processes are now stored in 177 underground storage tanks at the Hanford tank farms. Workers at the Hanford tank farms have expressed concerns about chemical vapor exposures for many years. During the spring of 2014, worker reports of chemical odors and/or symptoms prompted the development of the Savannah River National Laboratory Hanford Tank Vapor Assessment Team (TVAT) and their resulting independent assessment and recommendations concerning tank farm worker reports of vapors. The Tank Vapor Assessment report included a hypothesis that 'vapors coming out of tanks in high concentration (bolus) plumes sporadically intersected with the breathing zones of workers, resulting in brief but intense exposures to some workers.' The focus of this effort is to present current knowledge to describe the mechanisms by which workers may experience short duration vapor concentrations above background in the tank farms environment. The TVAT hypothesis that workers have experienced concentrations approaching 80% of the tank headspace up to 3 meters (10 feet) from tank sources is not supported by sampling data or modeling results. Modeling indicates that concentrations are quickly reduced from the source, and that the upper end of predicted concentrations at worker breathing zones are a factor of 10 or more lower than source concentrations. Area measurements corroborate the fact that worker breathing zone concentrations are 10 to 100 times lower than source concentrations, and events with elevated concentrations are rare. These reduced vapor concentration levels may result in detectable odors or irritation, depending on a worker's specific odor threshold and sensitivity to the chemical species. Short-duration vapor events may be mitigated by evaluating daily atmospheric conditions in conjunction with planned tank farm activities. Monitoring changing conditions related to tank vapors concentrations at the source and within worker breathing zone is also an important step to protect workers from short duration elevated concentration events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of four ground-based retrievals of cloud droplet number concentration in marine stratocumulus with aircraft in situ measurements

Abstract. Cloud droplet number concentration (Nd) is crucial for understanding aerosol–cloud interactions (ACI) and associated radiative effects. We present evaluations of four ground-based Nd retrievals based on comprehensive datasets from the Atmospheric Radiation Measurement (ARM) Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. The Nd retrieval methods use ARM ENA observatory ground-based remote sensing observations from a micropulse lidar, Raman lidar, cloud radar, and the ARM NDROP (Droplet Number Concentration) value-added product (VAP), all of which also retrieve cloud effective radius (re). The retrievals are compared against aircraft measurements from the fast cloud droplet probe (FCDP) and the cloud and aerosol spectrometer (CAS) obtained from low-level marine boundary layer clouds on 12 flight days during summer and winter seasons. Additionally, the in situ measurements are used to validate the assumptions and characterizations used in the retrieval algorithms. Statistical comparisons of the probability distribution function (PDF) of the Nd and cloud re retrievals with aircraft measurements demonstrate that these retrievals align well with in situ measurements for overcast clouds, but they may substantially differ for broken clouds or clouds with low liquid water path (LWP). The retrievals are applied to 4 years of ground-based remote sensing measurements of overcast marine boundary layer clouds at the ARM ENA observatory to find that Nd (re) values exhibit seasonal variations, with higher (lower) values during the summer season and lower (higher) values during the winter season. The ensemble of various retrievals using different measurements and retrieval algorithms such as those in this paper can help to quantify Nd retrieval uncertainties and identify reliable Nd retrieval scenarios. Of the retrieval methods, we recommend using the micropulse lidar-based method. This method has good agreement with in situ measurements, less sensitivity to issues arising from precipitation and low cloud LWP and/or optical depth, and broad applicability by functioning for both daytime and nighttime conditions.

54 ENVIRONMENTAL SCIENCES↗

Low-Temperature Characterization of a Nonaqueous Liquid Electrolyte for Lithium Batteries

Rechargeable batteries exhibit poor performance at low temperatures due to sluggish ion transport through the electrolytic phase. Ion transport is governed by three transport parameters—conductivity, diffusion coefficient, and the cation transference number with respect to the solvent velocity—and the thermodynamic factor. Understanding how these parameters change with temperature is necessary for designing improved electrolytes. In this work, we combine electrochemical techniques with electrophoretic NMR to determine the temperature dependence of these parameters for a liquid electrolyte, LiTFSI salt dissolved in tetraglyme between −20 and 45 °C. At colder temperatures, all species in the electrolyte tend to move more slowly due to increasing viscosity, which translates to a monotonic decrease in conductivity and diffusion coefficient with decreasing temperature. Surprisingly, we find that the field-induced velocity of solvent molecules at a particular salt concentration is a nonmonotonic function of temperature. The cation transference number with respect to the solvent velocity thus exhibits a complex dependence on temperature and salt concentration. The measured thermodynamic and transport properties are used to predict concentration gradients that will form in a lithium-lithium symmetric cell under a constant applied potential as a function of temperature using concentrated solution theory. The calculated steady current at −20 °C is lower than that at 45 °C by roughly two orders of magnitude.

25 ENERGY STORAGE↗

Experimental Report: Multi-Instrument Comparison of AAF Condensation Particle Counters

Condensation particle counters (CPCs), also known as condensation nucleus counters (CNCs) are sophisticated instruments designed to measure the concentration of aerosol particles in the atmosphere. These devices are pivotal in environmental monitoring, industrial applications, and scientific research, particularly in atmospheric studies. CPCs are vital for understanding the role of aerosols in climate systems. Aerosols influence cloud formation, radiative forcing, and atmospheric chemistry. By providing accurate measurements of particle concentrations and distributions, CPCs contribute to models that predict atmospheric impact and weather patterns (Mei et al. 2021). CPCs operate by enlarging submicron particles, including those as small as a few nanometers, to sizes detectable by optical methods. This report delves into the mechanisms, importance, and contributions of CPCs to atmospheric research at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), highlighting their role in advancing air quality assessment, pollution control, and atmospheric studies.

54 ENVIRONMENTAL SCIENCES↗