Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype

We investigated the active pixel sensors based on the High-Voltage CMOS technology as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. Our paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. These results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Single Event Upset in ATLAS IBL

Effects of Single Event Upsets (SEU) and Single Event Transients (SET) are studied in the FE-I4B chip of the innermost layer of the ATLAS pixel system. SEU/SET affect the FE-I4B Global Registers as well as the settings for the individual pixels, causing, among other things, occupancy losses, drops in the low voltage currents, noisy pixels, and silent pixels. Quantitative data analysis and simulations indicate that SET dominate over SEU on the load line of the memory. Operational issues and mitigation techniques are presented.

47 OTHER INSTRUMENTATION↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Active Region Extent Assessment with X-rays (AREA-X)

The development of semiconductor sensors for new particle tracking detectors places increasing limits on sensor characteristics such as uniformity, size and shape of inefficient areas and size of active compared to inactive sensor areas. Accurately assessing these relatively subtle effects requires either measurements in particle beams or the modification of samples to be used in dedicated laser test setups. Active Region Extent Assessment with X-rays (AREA-X) has been developed as an alternative method for the fast, efficient and precise study of the active area of a semiconductor sensor. It uses a monochromatic, micro-focused X-ray beam with a 10–20 keV energy range as provided by several synchrotron beam lines and uses the photo current induced in the sensor to measure the depth of the responsive sensor volume. It can be used to study local inhomogeneities or inefficiencies, the overall extent of the active sensor volume and its shape and its localised application, which makes the need to gather statistics over a large area unnecessary, allowing for fast readout, which enables studies of the sensor behaviour at a range of external parameters, e.g. temperature or applied bias voltage. This paper presents the measurement concept and technical setup of the measurement, results from initial measurements as well as capabilities and limitations of the method.

47 OTHER INSTRUMENTATION↗

Performance of the ATLAS forward proton Time-of-Flight detector in Run 2

We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-statistics data samples collected at low and moderate pile-up in 2017, the first year when the detectors were installed on both sides of the interaction region. While low efficiencies are observed, of the order of a few percent, the resolutions of the two ToF detectors measured individually are 21 ps and 28 ps, yielding an expected resolution of the longitudinal position of the interaction, z vtx , in the central ATLAS detector of 5.3 ± 0.6 mm. This is in agreement with the observed width of the distribution of the difference between z vtx , measured independently by the central ATLAS tracker and by the ToF detector, of 6.0 ± 2.0 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

Front-end electronics for detector readout↗

Making Quality HPGe Gamma Ray Spectrum Measurements for Uranium: The Role of FRAM for Analysis, Quality Control and Enrichment Measurements, and Opportunities for Improved Quantification Documentation

Enrichment measurements are used in uranium safeguards verification and accountancy as both an attribute signature and in the interpretation of other nondestructive assay information, such as active interrogation for mass. Accurate and reliable assessments require quality information. The practices used to collect the raw data are therefore the crucial first step in managing the overall quality and uncertainty of the enrichment determination. This report discusses several topics associated with gamma-ray spectrum measurements of uranium using HPGe detectors. First a discussion of good data acquisition practices including physical setup, detector types and configurations, detector shielding and filtering, spectrum stabilization, and data acquisition protocols. Next is a discussion of analysis options to obtain isotopic composition and/or enrichment centered on the FRAM gamma ray isotopic analysis software. The report discusses the results of the development of a FRAM parameter file to perform classical Enrichment Meter Principle (EMP) analysis. Possible analysis and data acquisition issues (random summing, x-ray fluorescence peaks, peak interferences, shielding) that can affect FRAM analyses are also discussed. There is also a brief discussion of FRAM measurements in the field. Under the topic of uncertainty propagation and quantification in FRAM, uncertainty propagation verification methods and gaps in available uncertainty quantification data for uranium is covered. Suggestions are made for areas where ORNL can contribute to closing the identified uncertainty quantification gaps, and also to contributing nuclear data quality spectra to the research community.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nano-optical observation of cascade switching in a parallel superconducting nanowire single photon detector

The device physics of parallel-wire superconducting nanowire single photon detectors is based on a cascade process. Using nano-optical techniques and a parallel wire device with spatially separate pixels, we explicitly demonstrate the single- and multi-photon triggering regimes. We develop a model for describing efficiency of a detector operating in the arm-trigger regime. We investigate the timing response of the detector when illuminating a single pixel and two pixels. We see a change in the active area of the detector between the two regimes and find the two-pixel trigger regime to have a faster timing response than the one-pixel regime.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Secondary Emission Detector Modules for High Energy Physics Experiments

The objectives of this Phase I SBIR project and the corresponding work plan consisted of detector geometry simulations and functional studies of pre-prototypes for both venetian-blind type and MEMS type. Modifications and improvements to the vacuum test station and data acquisition were also made throughout the project. In the final stages of this Phase I, we were able to do initial testing of devices built and we provide in this report the results of these measurements and all corresponding conclusions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A free-standing wire scattering technique to monitor calibration variations of the DIII-D density profile reflectometer

Real-time phase calibration of the ITER profile reflectometer is essential due to the long plasma duration and expected waveguide path length changes during a discharge. Progress has been recently made in addressing this issue by employing a phase calibration technique on DIII-D that monitors calibration variations that occur during each plasma discharge. By installing a thin free-standing metallic wire (1 mm diameter) near the end of the overmoded waveguide transmission system (oriented perpendicular to the waveguide axis), the round-trip phase shift from the wire is detected simultaneously with the plasma phase shifts. Variations in the reflectometer round trip path length (-26 m) are then calculated after each DIII-D plasma discharge, allowing the calibration phase to be accurately monitored and updated. The round-trip reflectometer path length is observed to vary by -3 mm (root mean square value) during a typical DIII-D discharge. Using the variations in calibration phase, the density profile measurement accuracy can be improved. Since the wire retro-reflected power is -0.01 of the plasma signal, minimal effect is observed on the reflected signal from the plasma. Importantly, through a suitable choice in wire diameter, the calibration signal can be made approximately independent of the V-band reflectometer launch polarization. Furthermore, this is particularly important on DIII-D since orthogonal X- and O-mode polarized beams are coupled into the same transmission waveguide and launch antenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hall B superconducting magnets for the CLAS12 detector at JLAB

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the 12 GeV upgrade is presented.

43 PARTICLE ACCELERATORS↗

Status of Hall B superconducting magnets for the CLAS12 detector at JLab

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the CLAS12 detector is presented.

43 PARTICLE ACCELERATORS↗

High Energy Electromagnetic Particle Transportation on the GPU

We present massively parallel high energy electromagnetic particle transportation through a finely segmented detector on a Graphics Processing Unit (GPU). Simulating events of energetic particle decay in a general-purpose high energy physics (HEP) detector requires intensive computing resources, due to the complexity of the geometry as well as physics processes applied to particles copiously produced by primary collisions and secondary interactions. The recent advent of hardware architectures of many-core or accelerated processors provides the variety of concurrent programming models applicable not only for the high performance parallel computing, but also for the conventional computing intensive application such as the HEP detector simulation. The components of our prototype are a transportation process under a non-uniform magnetic field, geometry navigation with a set of solid shapes and materials, electromagnetic physics processes for electrons and photons, and an interface to a framework that dispatches bundles of tracks in a highly vectorized manner optimizing for spatial locality and throughput. Core algorithms and methods are excerpted from the Geant4 toolkit, and are modified and optimized for the GPU application. Program kernels written in C/C++ are designed to be compatible with CUDA and OpenCL and with the aim to be generic enough for easy porting to future programming models and hardware architectures. To improve throughput by overlapping data transfers with kernel execution, multiple CUDA streams are used. Issues with floating point accuracy, random numbers generation, data structure, kernel divergences and register spills are also considered. Performance evaluation for the relative speedup compared to the corresponding sequential execution on CPU is presented as well.

Canal, P.↗

The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies

The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗