Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Active-Pixel Image Sensor With Analog-To-Digital Converters

Proposed single-chip integrated-circuit image sensor contains 128 x 128 array of active pixel sensors at 50-micrometer pitch. Output terminals of all pixels in each given column connected to analog-to-digital (A/D) converter located at bottom of column. Pixels scanned in semiparallel fashion, one row at time; during time allocated to scanning row, outputs of all active pixel sensors in row fed to respective A/D converters. Design of chip based on complementary metal oxide semiconductor (CMOS) technology, and individual circuit elements fabricated according to 2-micrometer CMOS design rules. Active pixel sensors designed to operate at video rate of 30 frames/second, even at low light levels. A/D scheme based on first-order Sigma-Delta modulation.

Fossum, Eric R.↗

Characterizing Material Scalability for Ultralight Lattice Design

Stiff yet ultra-light lattice structures constructed using digital materials have many practical applications as the building block for aircraft and other structures. By furthering our understanding of how material configuration affects the structural properties of an ultralight lattice, we can intelligently design these structures based on their intended function. Here we compare the behavior of ultralight lattice structures when fabricated by different materials. The individual unit cells of the lattice structures are referred to as voxels. The stiffness, elastic modulus, and yield strength of the specimens in compression and tension are determined through mechanical testing. Specimens are tested both as single voxel as well as 4x4x4 voxel constructions on an Instron 5982 Universal Testing System until failure. Each voxel is manufactured in bulk through injection molding, with a unit cell pitch of 76.2 mm. Individual voxels are fastened with machine screws and nuts to create assemblies. Four separate materials are used as voxel compositions in this experiment. These include a homogeneous polymer referred to as Ultem 1000, a glass-fiber reinforced polymer referred to as Ultem 2200, a polymer with chopped carbon fibers as 30% of its fill, and homogenous polypropylene. This work compares mechanical behavior, as well as the convergence behavior of the lattice as the size of the lattice assembly increases for various materials. The goal of this study is to characterize the behavior of homogenous lattices such that heterogenous lattices can be designed with different material voxels to achieve target material properties for ultralight space applications.

Sajjadi, Afsheen↗

Design, development, and fabrication of a electronic analog microminiaturized electronic analog signal to discrete time interval converter

The microminiaturization of an electronic analog signal to discrete time interval converter is presented. Discrete components and integrated circuits comprising the converter were assembled on a thin-film ceramic substrate containing nichrome resistors with gold interconnections. The finished assembly is enclosed in a flat package measuring 3.30 by 4.57 centimeters. The module can be used whenever conversion of analog to digital signals is required, in particular for the purpose of regulation by means of pulse modulation. In conjunction with a precision voltage reference, the module was applied to control the duty cycle of a switching regulator within a temperature range of -55 C to +125 C, and an input voltage range of 10V to 35V. The output-voltage variation was less than + or - 300 parts per million, i.e., less than + or - 3mV for a 10V output.

Schoenfeld, A. D.↗

Performance of preproduction model cesium beam frequency standards for spacecraft applications

A cesium beam frequency standards for spaceflight application on Navigation Development Satellites was designed and fabricated and preliminary testing was completed. The cesium standard evolved from an earlier prototype model launched aboard NTS-2 and the engineering development model to be launched aboard NTS satellites during 1979. A number of design innovations, including a hybrid analog/digital integrator and the replacement of analog filters and phase detectors by clocked digital sampling techniques are discussed. Thermal and thermal-vacuum testing was concluded and test data are presented. Stability data for 10 to 10,000 seconds averaging interval, measured under laboratory conditions, are shown.

Levine, M. W.↗

Parameterizable Library Components for SAW Devices

To facilitate quick fabrication of Surface Acoustic Wave (SAW) sensors we have found it necessary to develop a library of parameterizable components. This library is the first module in our strategy towards a design tool that is integrated into existing Electronic Design Automation (EDA) tools. This library is similar to the standard cell libraries found in digital design packages. The library cells allow the user to input the design parameters which automatically generate a detailed layout of the SAW component. This paper presents the results of our development of parameterizable cells for an InterDigitated Transducer (IDT), reflector, SAW delay line, and both one and two port resonators.

Wilson, William C.↗

Design and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction

The feasibility of designing short curved wall axially symmetrical subsonic diffusers utilizing suction through slots in the diffuser walls to prevent flow separation was investigated. A potential flow analysis was made, and a digital computer program was written for determining the diffuser wall contour for prescribed boundary conditions. The flow field included branch flow so that the suction slot geometry could be a part of the diffuser design. One bell shaped diffuser and three annular diffusers with area ratios of either 2.5:1 or 3:1 were designed, fabricated, and tested. Minimum suction requirements of metastable operation ranged from 6.3 percent to 12 percent when operating with inlet air velocities in the 1000 to 250 ft/sec (30 to 76 m/sec) range. For stable operation suction rates from 10 percent to 22 percent were required. In all cases the diffuser effectiveness was above 95 percent based on the conventional definition, and from 81 percent to 94 percent when the suction loss was accounted for. The exit velocity profiles were virtually flat with no more than + or - 9% variation over 95 percent of the exit area when operated with sufficient suction to prevent flow separation.

Yang, T.↗

Electric prototype power processor for a 30cm ion thruster

An electrical prototype power processor unit was designed, fabricated and tested with a 30 cm mercury ion engine for primary space propulsion. The power processor unit used the thyristor series resonant inverter as the basic power stage for the high power beam and discharge supplies. A transistorized series resonant inverter processed the remaining power for the low power outputs. The power processor included a digital interface unit to process all input commands and internal telemetry signals so that electric propulsion systems could be operated with a central computer system. The electrical prototype unit included design improvement in the power components such as thyristors, transistors, filters and resonant capacitors, and power transformers and inductors in order to reduce component weight, to minimize losses, and to control the component temperature rise. A design analysis for the electrical prototype is also presented on the component weight, losses, part count and reliability estimate. The electrical prototype was tested in a thermal vacuum environment. Integration tests were performed with a 30 cm ion engine and demonstrated operational compatibility. Electromagnetic interference data was also recorded on the design to provide information for spacecraft integration.

Biess, J. J.↗

Structure and Fabrication of a Microscale Flow-Rate/Skin Friction Sensor

A floating element shear sensor and method for fabricating the same are provided. According to an embodiment, a microelectromechanical systems (MEMS)-based capacitive floating element shear stress sensor is provided that can achieve time-resolved turbulence measurement. In one embodiment, a differential capacitive transduction scheme is used for shear stress measurement. The floating element structure for the differential capacitive transduction scheme incorporates inter digitated comb fingers forming differential capacitors, which provide electrical output proportional to the floating element deflection.

Chandrasekharan, Vijay↗

Digital Microfluidics Sample Analyzer

Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.

Pollack, Michael G.↗

Sand Shear Band Thickness Measurements by Digital Imaging Techniques

Digital imaging analysis was used to study localized deformations in granular materials tested under plane strain condition. Two independent techniques were applied and compared. In the first, the digitized optical images of a grid printed on the latex membrane were used to measure the shear band orientation angle and thickness, and were found to be 54.5' and 3.01 mm respectively. The second technique involved introducing an ultra-low viscosity resin into the specimen in preparation for thin- sectioning and microscopic study of the internal fabric. A total of 24 microscopic images obtained from four thin sections were analyzed and void ratio variation was measured. The shear band thickness measurements from images located along the shear band axis (at two locations) were equal to 3.19 mm and 3.29 mm which are very close to the average value obtained from surface analysis. The study was then extended to investigate the effects of sand grain-size and properties, specimen density, and confining pressure on shear band thickness. It was found that the normalized shear band thickness decreases as grain-size and confining pressure increase and as density decreases. Finally, shear band thickness is highly influenced by the specimen dilatancy.

Alshibli, Khalid A.↗

Number Codes Readable by Magnetic-Field-Response Recorders

A method of encoding and reading numbers incorporates some of the features of conventional optical bar coding and radio-frequency identification (RFID) tagging, but overcomes some of the disadvantages of both: (1) Unlike in conventional optical bar coding, numbers can be read without having a line of sight to a tag; and (2) the tag circuitry is simpler than the circuitry used in conventional RFID. The method is based largely on the principles described in Magnetic-Field-Response Measurement-Acquisition System (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006) page 28. To recapitulate: A noncontact system includes a monitoring unit that acquires measurements from sensors at distances of the order of several meters. Each sensor is a passive radio-frequency (RF) resonant circuit in the form of one or more inductor(s) and capacitor(s). The monitoring unit a handheld unit denoted a magnetic field response recorder (MFRR) generates an RF magnetic field that excites oscillations in the resonant circuits resulting in the sensors responding with their own radiated magnetic field. The resonance frequency of each sensor is made to differ significantly from that of the other sensors to facilitate distinction among the responses of different sensors. The MFRR measures selected aspects of the sensor responses: in a typical application, the sensors are designed so that their resonance frequencies vary somewhat with the sensed physical quantities and, accordingly, the MFRR measures the resonance frequencies and variations thereof as indications of those quantities. In the present method, the resonance circuits are not used as sensors. Instead, the circuits are made to resonate at fixed frequencies that correspond to digits to be encoded. The number-encoding scheme is best explained by means of examples in which each resonant circuit consists of a spiral trace inductor electrically connected to a set of parallel-connected capacitors in the form of interdigitated electrode pairs (see figure). The inductor and capacitor(s) in each resonant circuit can be fabricated as a patterned thin metal film by means of established metal-deposition and -patterning techniques. The capacitance and, hence, the resonance frequency, depends on the number of interdigitated electrodes connected to the inductor. In a similar manner, sets of electrodes could be used.

Woodard, Stanley E.↗

Shuttle bit rate synchronizer

A shuttle bit rate synchronizer brassboard unit was designed, fabricated, and tested, which meets or exceeds the contractual specifications. The bit rate synchronizer operates at signal-to-noise ratios (in a bit rate bandwidth) down to -5 dB while exhibiting less than 0.6 dB bit error rate degradation. The mean acquisition time was measured to be less than 2 seconds. The synchronizer is designed around a digital data transition tracking loop whose phase and data detectors are integrate-and-dump filters matched to the Manchester encoded bits specified. It meets the reliability (no adjustments or tweaking) and versatility (multiple bit rates) of the shuttle S-band communication system through an implementation which is all digital after the initial stage of analog AGC and A/D conversion.

Huey, D. C.↗

Combining Multiple Gyroscope Outputs for Increased Accuracy

A proposed method of processing the outputs of multiple gyroscopes to increase the accuracy of rate (that is, angular-velocity) readings has been developed theoretically and demonstrated by computer simulation. Although the method is applicable, in principle, to any gyroscopes, it is intended especially for application to gyroscopes that are parts of microelectromechanical systems (MEMS). The method is based on the concept that the collective performance of multiple, relatively inexpensive, nominally identical devices can be better than that of one of the devices considered by itself. The method would make it possible to synthesize the readings of a single, more accurate gyroscope (a virtual gyroscope) from the outputs of a large number of microscopic gyroscopes fabricated together on a single MEMS chip. The big advantage would be that the combination of the MEMS gyroscope array and the processing circuitry needed to implement the method would be smaller, lighter in weight, and less power-hungry, relative to a conventional gyroscope of equal accuracy. The method (see figure) is one of combining and filtering the digitized outputs of multiple gyroscopes to obtain minimum-variance estimates of rate. In the combining-and-filtering operations, measurement data from the gyroscopes would be weighted and smoothed with respect to each other according to the gain matrix of a minimum- variance filter. According to Kalman-filter theory, the gain matrix of the minimum-variance filter is uniquely specified by the filter covariance, which propagates according to a matrix Riccati equation. The present method incorporates an exact analytical solution of this equation.

Bayard, David S.↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

A Low-Complexity Circuit for On-Sensor Concurrent A/D Conversion and Compression

A low-complexity circuit for on-sensor compression is presented. The proposed circuit achieves complexity savings by combining a single-slope analog-to-digital converter with a Golomb-Rice entropy encoder and by implementing a low-complexity adaptation rule. The adaptation rule monitors the output codewords and minimizes their length by incrementing or decrementing the value of the Golomb-Rice coding parameter k. Its hardware implementation is one order of magnitude lower than existing adaptive algorithms. The compression circuit has been fabricated using a 0.35 micrometers CMOS technology and occupies an area of 0.0918 mm2. Test measurements confirm the validity of the design

Leon-Salas, Walter D.↗

Robust Mapping of Incoherent Fiber-Optic Bundles

A method and apparatus for mapping between the positions of fibers at opposite ends of incoherent fiber-optic bundles have been invented to enable the use of such bundles to transmit images in visible or infrared light. The method is robust in the sense that it provides useful mapping even for a bundle that contains thousands of narrow, irregularly packed fibers, some of which may be defective. In a coherent fiber-optic bundle, the input and output ends of each fiber lie at identical positions in the input and output planes; therefore, the bundle can be used to transmit images without further modification. Unfortunately, the fabrication of coherent fiber-optic bundles is too labor-intensive and expensive for many applications. An incoherent fiber-optic bundle can be fabricated more easily and at lower cost, but it produces a scrambled image because the position of the end of each fiber in the input plane is generally different from the end of the same fiber in the output plane. However, the image transmitted by an incoherent fiber-optic bundle can be unscrambled (or, from a different perspective, decoded) by digital processing of the output image if the mapping between the input and output fiber-end positions is known. Thus, the present invention enables the use of relatively inexpensive fiber-optic bundles to transmit images.

Roberts, Harry E.↗

Quiet Clean Short-Haul Experimental Engine (QCSEE) Under-the-Wing (UTW) Final Design Report

The QCSEE Program provides for the design, fabrication, and testing of two experimental high-bypass geared turbofan engines and propulsion systems for short-haul passenger aircraft. The overall objective of the program is to develop the propulsion technology required for future externally blown flap types of aircraft with engines located both under-the-wing and over-the-wing. This technology includes work in composite structures and digital engine controls.

Source record↗

NASA Tech Briefs, October 2013

Topics include: A Short-Range Distance Sensor with Exceptional Linearity; Miniature Trace Gas Detector Based on Microfabricated Optical Resonators; Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection; Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection; Mission Data System Java Edition Version 7; Adaptive Distributed Environment for Procedure Training (ADEPT); LEGEND, a LEO-to-GEO Environment Debris Model; Electronics/Computers; Millimeter-Wave Localizers for Aircraft-to-Aircraft Approach Navigation; Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces; SpaceCube Version 1.5; High-Pressure Lightweight Thrusters; Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites; Ambient Dried Aerogels; Applications for Gradient Metal Alloys Fabricated Using Additive Manufacturing; Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer; Propellant-Flow-Actuated Rocket Engine Igniter; Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads; Method to Increase Performance of Foil Bearings Through Passive Thermal Management; Unibody Composite Pressurized Structure; JWST Integrated Science Instrument Module Alignment Optimization Tool; Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique; Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures; Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation; Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum; Educational NASA Computational and Scientific Studies (enCOMPASS); Coarse-Grain Bandwidth Estimation Scheme for Large-Scale Network; Detection of Moving Targets Using Soliton Resonance Effect; High-Efficiency Nested Hall Thrusters for Robotic Solar System Exploration; High-Voltage Clock Driver for Photon-Counting CCD Characterization; Development of the Code RITRACKS; and Enabling Microliquid Chromatography by Microbead Packing of Microchannels.

Source record↗