Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Advanced Failure Determination Measurement Techniques Used in Thermal Fatigue Life Testing of Electronic Packaging

Thermal fatigue life testing of various electronic packaging technologies is being performed by the Reliability Technology Group at the Jet Propulsion Laboratory. These testing efforts are in progress to improve uderstanding of the reliability issues associated with low volume packaging technologies for space applications and to develop qualification and acceptance approaches for these technologies. The work described here outlines the electrical failure detection techniques used during testing by documenting the circuits and components used to make these measurements, the sensitivity of the measurements, and the applicability of each specific measurement.

fatigue surface mount measurement testing thermal ↗

Evolution of titanium particle combustion in potassium perchlorate and air

Understanding titanium particle combustion processes is critical not only for characterizing existing pyrotechnic systems but also for creating new igniter designs. In order to characterize titanium particle combustion processes, morphologies, and temperatures, simultaneous spatially-resolved electric field holography and imaging pyrometry techniques were used to capture post-ignition data at up to 7 kHz. Due to the phase and thermal distortions present in the combustion cloud, traditional digital in-line holography techniques fail to capture accurate data. Here in this work, electric field holography techniques are used in order to cancel distortions and capture the three-dimensional spatial locations and diameters of the particles. In order to estimate the projected surface temperatures of the titanium particles, an imaging pyrometry method that ratios emission at 750 and 850 nm is utilized. Using these diagnostics, joint statistics are collected for particle size, morphology, velocity, and temperature. Results show that, early in the combustion process, the titanium particles are primarily oxidized by potassium perchlorate inside the igniter cup, resulting in projected surface temperatures near 3000 K. Later in the process, the particles interact with ambient air, resulting in lower surface temperatures around 2400 K and the formation of flame zones. These results are consistent with adiabatic flame temperature predictions as well as particle morphology observations of a titanium core with a TiO 2 surface. Late stage particle expansion, star fragmentation, and molten droplet breakup events are also observed using the time-resolved morphology and temperature diagnostics. These results illustrate the different stages of titanium particle combustion in pyrotechnic environments, which can be used to inform improvements in next-generation igniters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection Thresholds and Sensitivities of Geophysical Techniques for CO2 Plume Monitoring

This report assesses capabilities and limitations of different geophysical techniques for monitoring geologic sequestration of CO 2 . Seismic, gravity, electrical, and electromagnetic (EM) techniques are considered. Monitoring approaches for site characterization prior to CO 2 injection are different from those used while injecting CO 2 , or those suitable for post-injection monitoring. The focus of this study is on the aspects relevant to long-term monitoring of large areas in the post-injection phase, and specifically on early detection of secondary CO 2 plumes.

54 ENVIRONMENTAL SCIENCES↗

Development of a thin film solid state gaseous HCl sensor

The selection of materials to develop a thin film HCl sensor is discussed. Data were primarily concerned with chemical and physical properties of the film and with electrical properties which exhibit and enhance electrical response when HCl is absorbed on the film surface. Techniques investigated for enhancing electrical response include changing conditions for growing films, adding impurities to the film, changing ambient light intensity, and altering the ambient temperature of the sensing element.

Source record↗

Insights into negative differential resistance in MoS 2 Esaki diodes: A first-principles perspective

MoS 2 is a two-dimensional material with a band gap depending on the number of layers and tunable by an external electric field. The experimentally observed intralayer band-to-band tunneling and interlayer band-to-band tunneling in this material present an opportunity for new electronic applications in tunnel field-effect transistors. However, such a widely accepted concept has yet to be been supported by theoretical investigations based on first principles. In this paper, using density functional theory, in conjunction with nonequilibrium Green's function techniques and our electric field gating method, enabled by a large-scale computational approach, we study the relation between band alignment and transmission in planar and side-stack MoS 2 p–i–n junction configurations. Here, we demonstrate the presence of negative differential resistance for both in-plane and interlayer current, a staple characteristic of tunnel diode junctions, and analyze the physical origin of such an effect. Electrostatic potentials, the van der Waals barrier, and a complex band analysis are also examined for a thorough understanding of Esaki diodes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study on Electrostatic Separation of Quinoline Insolubles from Coal Tar Pitch

The feasibility of electrical separation in the removal of quinoline insoluble (QI) particles from coal tar pitch (CTP) was experimentally investigated. QI particle involvement prohibits the effective fabrication of high-quality value-added products, such as carbon fibers, from CTP. A substantial and sustainable CTP market exists around the world; therefore, a strong incentive exists to develop a viable technical approach to effectively and economically remove QI particles from CTP. The electrical separation method shows promise to achieve this technical goal (Cao et al., 2012). Even with the given setup (wire- cylinder adapted), critical issues remain to be addressed for this method to be applicable to the CTP: (1) identifying the wash oil used in the original QI separation, (2) understanding the mechanism of QI separation, (3) characterizing the deposit, and (4) identifying the QI. This study integrated a set of experimental and analysis techniques into the electrical separation tests to address the aforementioned issues. Key findings are as follows: 1. Electric current responses: • The electric current level of the CTP–wash oil solution reported by Cao et al. (2012) can be attained by using a mixture of 25% quinoline and 75% toluene for the CTPs examined in this study under the same electrical load condition. • The electric current tends to decrease during the test period because of the decreasing number of charged particles. • The reversed field corresponded to the configuration of electrostatic precipitation for positive corona discharge. The high electric field can result in dielectric breakdown and lead to an abrupt current surge. 2 Deposit response and solvent candidates: • Deposit of particles in CTP mixture can be effectively implemented in a wire-cylinder configuration as proposed and examined in this study. • Deposit depends on the solvents. Among the solvents tested, two- and three-part solvents that included quinoline and ethanol (i.e., 25% quinoline and 75% toluene; 50% quinoline and 50% toluene; and 33% wash oil, 33% BTX, and 34% ethanol) produced the highest deposit weight. • The deposit process examined in this study is derived from the charged particles. An appreciable relation exists between deposit weight and electric charge. 3. QI removal efficiency (RE): • The RE of the electrostatic separation can reach as high as 76.2% for Carbores, and 61.6% for Koppers. • The RE can be further enhanced if the field level increases from 0.16 kV/mm that was used in the current study to 0.23 kV/mm, according to the relation established between the RE and the electric field. 4. Testing of the modeling system: • The motion of particles is originally driven by the charge-based electric force in the cases tested. The solid particle separation mechanism is similar to that of QI deposition in CTP. • The mechanical movement of solid particles can be strongly affected by the gravitational and viscous forces in the electric field. 5. EDS analysis and chemical compositions: • The main chemical composition of deposit QI matches that of as-prepared CTP QI. The deposit QI is derived from the same group of the CTP QI. • In addition to carbon, the QI contains oxygen, sodium, aluminum, silicon, iron, and sulfur. The work for the near future is also discussed.

01 COAL, LIGNITE, AND PEAT↗

Copper Electrode on Flexible Substrate by Intense Pulsed Light Sintering of Microsized Copper Particles

Metal electrodes deposited in a grid pattern onto flexible polymer substrates have been shown to be a viable alternative to replace indium tin oxide (ITO) as the transparent anode for organic photovoltaics. copper may be a better alternative in terms of cost and stability for large area low-cost solar modules, specifically on roll-to-roll platforms. These customized electrode patterns can be fabricated from copper nanoparticles through various printing techniques applicable to solution phase processing. The Intense Pulsed Light (IPL) technique has been used to sinter copper nanoparticles (~100nm) to fabricate conductive copper electrodes on flexible polymer substrates. However, compared to nanosized (~100 nm) copper particles, microsized (~2 um) copper is much cheaper. In this work, microsized (~2 um) copper is used to produce high conductive copper inks. The conductivity of the print can be adjusted through the use of surfactant. IPL sintering was optimized to obtain high conductivity copper films. In conclusion, several microscopic and electrical spectroscopic characterization techniques such as scanning electron microscopy (SEM), x-ray diffraction (XRD), 4-point probe resistivity measurements were employed to characterize the copper electrodes.

14 SOLAR ENERGY↗

Joint inversion of electromagnetic measurements for the determination of water saturation profiles in concrete structures

Highlights: • DC-electrical and dielectric data are combined to estimate concrete saturation degree. • A joint inversion approach of the electromagnetic measurements is proposed. • The sensitivity of the measurements to the saturation model parameters is analysed. • The new joint approach was developed and is applied to synthetic and real data. • The benefits of the joint approach over the inversion of one data type are highlighted. Water saturation profiles in concrete are essential to assess its durability and can be determined using non-destructive techniques, especially the electric and the capacitive methods. In this paper, we propose a new inversion scheme where both resistivity and permittivity measurements are inverted jointly to retrieve the saturation profile. The finite element method is used to model the measurements in 3D, the concrete having a saturation profile with depth, represented by a continuous model taking the form of a Weibull curve with four parameters. A non-linear least-squares optimization based on the Levenberg-Marquardt scheme is developed for the inversion of measurements. Results show that information gathered from both measurements enriches the reconstructed profile, leading to a more reliable estimation of saturation profiles. We believe that the joint inversion method herein developed could lead to the study of more complex phenomena, such as the coupled water-chloride ingress.

36 MATERIALS SCIENCE↗

Electric fields in the solar atmosphere - A review

A review is presented of remote sensing techniques which measure the electric field component transverse to the line of sight and achieve a sensitivity range of 5-10 V/cm. Three models are shown to predict quasistatic, macroscopic values of E(parallel), the electric field component parallel to the magnetic vector, beyond the sensitivity range considered. These processes are: the discharge model of flares; the models of return currents related to flare particle beams; and the models of neutral sheets related to two-ribbon flares and postflare loops. Time dependent electric fields related to MHD and plasma waves, and to plasma disturbance, may allow the detection of both E components (parallel and perpendicular). The uncertainty relating to the emission measures, time scales, volumes, and plasma conditions of these flares and electrified plasma volumes is emphasized. It is pointed out, however, that important information can be obtained by observing electric fields at existing sensitivity levels. By measuring these E-fields, the understanding of flares and related dynamic events can be improved.

Foukal, P.↗

Benchtop-Scale High Temperature Molten Salt Electrochemical Reactors: Experimental Setup and Considerations

Molten salt electrochemical reduction (MSER) is the dominant production method for aluminum and titanium, and emerging technologies for producing other commodity metals with these highly electrified techniques have demonstrated promising results. However, the scale up of MSER of materials such as iron and silicon are limited by the challenging issues of materials compatibility and impurity control. This work describes an experimental MSER setup using both chloride and carbonate salts. This setup is designed for operations outside of a glovebox, which is practical from an industrial perspective, but creates unique challenges. This work serves as a practical guide to discuss some key operational difficulties such as temperature control, air and humidity, material compatibility, developing strong electrical measurements and techniques, and safety.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical self-calibration of nonideal bolometers

An analytical method for determining the absorbed energy calibration of an IR bolometer from purely electrical measurements is presented. The technique is targeted at detectors with purely electrical nonlinearities. It is shown that the responsivity can be derived from the I-V plot if the limiting high-frequency impedance is measured. The electrical nonlinearity is then the difference between the impedance and the dc resistance. The model is used for designing a circuit for measuring the relative impedance parameters. The results are applicable to studies of IR sources and the detection of energy pulses with bolometers.

Mather, J. C.↗

Low-speed flowfield characterization by infrared measurements of surface temperatures

An experimental program was aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions. Implementing a new technique, a long electrically heated wire was placed across a laminar jet. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified. Furthermore, using Nusselt number correlations, the velocity distribution could be deduced. The same approach was used to survey wakes behind cylinders in a wind-tunnel. This method is suited to investigate flows with position dependent velocities, e.g., boundary layers, confined flows, jets, wakes, and shear layers. It was found that the IR imaging camera cannot accurately track high gradient temperature fields. A correlation procedure was devised to account for this limitation. Other wind-tunnel experiments included tracking the development of the laminar boundary layer over a warmed flat plate by measuring the chordwise temperature distribution. This technique was applied also to the flow downstream from a rearward facing step. Finally, the IR imaging system was used to study boundary layer behavior over an airfoil at angles of attack from zero up to separation. The results were confirmed with tufts observable both visually and with the IR imaging camera.

Gartenberg, E.↗

Electric fields in the ionosphere and magnetosphere.

Review of current techniques for measuring ionospheric and magnetospheric electric fields and existing measurements. Considerable progress in understanding electric fields has been made in the auroral regions where fields originating basically from convection patterns in the magnetosphere and modified by ionospheric interaction have been detected by both the barium ion cloud and double floating probe techniques and have been compared against predictions. The anticorrelation of electric fields and auroral arcs, the establishment of the auroral electrojet currents as Hall currents, the irregular nature of the electric fields, and the reversal of the electric fields between the eastward and westward electrojet regions have been some of the important observations. Recent barium ion cloud observations in the polar cap have indicated that the long assumed electrojet return current across the polar cap does not exist.

Maynard, N. C.↗

Determining the electrical conductivity of metals using the 2 MA Thor pulsed power driver

We present the development of a pulsed power experimental technique to infer the electrical conductivity of metals from ambient to high energy density conditions. The method is implemented on Thor, a moderate scale (1–2 MA) pulsed power driver. The electrical conductivity of copper at elevated temperature (>4000 K) and pressure (>10 GPa) is determined, and a new tabular material model is developed, guided by density functional theory, which preserves agreement with existing experimental data. Minor modifications (<10%) are found to be necessary to the previous Lee–More–Desjarlais model isotherms in the vicinity of the melt transition in order to account for observed discrepancies with the new experimental data. An analytical model for magnetic direct drive flyer acceleration and Joule heating induced vaporization based on the Tsiolkovsky “rocket equation” is presented to assess sensitivity of the method to minor changes in electrical conductivity.

47 OTHER INSTRUMENTATION↗

Study of graphene p-n junctions formed by the electrostatic modification of the SiO2 substrate

Abstract We study the transport properties of mm-scale CVD graphene p-n junctions, which are formed in a single gated graphene field effect transistor configuration. Here, an electrical-stressing-voltage technique served to modify the electrostatic potential in the SiO 2 /Si substrate and create the p-n junction. We examine the transport characteristics about the Dirac points that are localized in the perturbed and unperturbed regions in the graphene channel and note the quantitative differences in the Hall effect between the perturbed and unperturbed regions. The results also show that the longitudinal resistance is highly sensitive to the external magnetic field when the Hall bar device operates as a p-n junction.

Science & Technology - Other Topics↗

Two-level systems in nucleated and non-nucleated epitaxial alpha-tantalum films

Building usefully coherent superconducting quantum processors depends on reducing losses in their constituent materials. Tantalum, like niobium, has proven utility as the primary superconducting layer within highly coherent qubits. However, unlike Nb, high temperatures are typically used to stabilize the desirable body-centered-cubic phase, α-Ta, during thin film deposition. It has long been known that a thin Nb layer permits the room-temperature nucleation of α-Ta, but here we observe the epitaxial process and present few-photon microwave loss measurements in Nb-nucleated Ta films. We compare resonators patterned from Ta films grown at high temperature (500 °C) and films nucleated at room temperature, in order to understand the impact of the crystalline order on quantum coherence. In both cases, films grew with Al 2 O 3 (001) ∥ Ta (110), indicating that the epitaxial orientation is independent of temperature and is preserved across the Nb/Ta interface. We use conventional low-power spectroscopy to measure two level system (TLS) loss as well as an electric-field bias technique to measure the effective dipole moments of TLS in the surfaces of resonators. In our measurements, Nb-nucleated Ta resonators had greater loss tangent (1.5 ± 0.1 × 10 -5 ) than non-nucleated (5 ± 1× 10 -6 ) in approximate proportion to defect densities as characterized by x-ray diffraction (0.27° vs 0.18° [110] reflection width) and electron microscopy (30 vs 70 nm domain size). Furthermore, the dependence of the loss tangent on domain size indicates that the development of more ordered Ta films is likely to lead to improvements in qubit coherence times. Moreover, low-temperature α-Ta epitaxy may enable the growth of microstate-free heterostructures, which would not withstand high temperature processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of a CFD Commercial Package to the Modeling of Acoustic Wave Propagation in Bubbly-Liquid Column

This document reports on the considerations and development of an initial computational model based on the first principles for predicting acoustic propagation in a wellbore based on a logging-while-drilling (LWD) tool. This tool could be used to create a large database of simulated signals mimicking gas-influx-while-drilling events (so-called “kicks”). While other logging techniques, such as electrical resistivity and bulk density, are available in LWD tools, the acoustic logging method was identified in a complementary experimental endeavor as the most appropriate for early kick detection due to its high sensitivity to the presence of gas in liquids.

03 NATURAL GAS↗