Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Design and Fabrication of a Thyristor Using Ion Implantation of Anode and Cathode

A thyristor is a solid-state semiconductor switch made up of four alternating p and n type layers. When the switch is turned on by a small pulse, current can flow as long as the device stays on. When the voltage drops below the turn on level or the current reverses, the switch will turn off. Thyristors only allow current to flow in one direction. One of the benefits of a thyristor device is in its capacity to conduct large voltages with a small device and a small turn-on pulse requirement. Another distinguishing feature of thyristors compared to other semiconductor devices is that it can only be in the on or off state, there’s no in-between state for the device to exist within. These properties make thyristors very useful as switch devices, especially in applications where current flow is only needed in one direction and could potentially be damaging in the opposite direction. Currently, thyristors are most commonly used to control very high power loads and they are available commercially in many designs to control different amounts of current.

42 ENGINEERING↗

Flexible Magnetic Polymer Composite Substrate with Ba 1.5 Sr 1.5 Z Hexaferrite Particles of VHF/Low UHF Patch Antennas for UAVs and Medical Implant Devices

Our goal is to fabricate flexible magnetic polymer composites as antenna substrates for very high frequency (VHF)/low ultra high frequency (UHF) antennas for unmanned aerial vehicles (UAVs) and medical devices. Magnetodielectric materials, which have permeability (μ) similar to permittivity (ε), have attracted great attention, because they facilitate miniaturization of microwave devices while keeping or enhancing electromagnetic characteristics. Mechanically millled Ba 1.5 Sr 1.5 Co 2 Fe 24 O 41 (Ba 1.5 Sr 1.5 Z) hexaferrite particles were used to increase permeability in the interesting frequency band. The microwave properties of Ba 1.5 Sr 1.5 Z composites were predicted and measured. Hansen’s zero-order analysis of antenna bandwidth and electromagnetic field simulation showed that the hexaferrite-based flexible composite could enhance a bandwidth and achieve the miniaturization of antennas as well. The magnetic antenna substrates can be a good solution to integrate antennas into the UAVs whose dimensions are comparable to or larger than communication wavelength.

36 MATERIALS SCIENCE↗

Preventing stent failure using adaptive shear responsive endovascular implant

A stent apparatus, system, and method that senses wall shear stress by measuring fluid flow at localized areas within the stent, that processes measured information through an integrated circuit, and selectively sends power to mechanically controllable stent surfaces which results in localized geometric changes. In various embodiments the stent apparatus, system, and method sends data to outside the body in real time.

Mukerjee, Erik V.↗

Modulating the Pseudoelastic Response of Nitinol Using Ion Implantation

This work explores whether ion beam modification can be used to modulate the austenite to martensite phase transformation in Nickel-Titanium (NiTi), thereby achieving novel or localized transformation properties in near-surface regions. We report this could provide alternatives to laser shot peening or other surface treatment methods and possibly expand applications in biomedical, aerospace, and other fields. Irradiation induces defects and internal stress that can serve as nucleation and/or pinning sites for the phase transformation. Thus, it can augment more convention- al approaches, including alloying, severe mechanical work, grain size reduction, and precipitation of coherent precipitates. A range of outcomes is possible in principle, including a shift of the critical stress or temperature for onset of the transformation, linearization, reduction of hysteresis, stabilization, and extent of transformation strain.

36 MATERIALS SCIENCE↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗